simalube 27764029 Automatic Single-Point Lubricator Instruction Manual

June 5, 2024
simalube

simalube 27764029 Automatic Single-Point Lubricator

Calculation and preparation of lubrication point

simalube 27764029
Automatic Single-Point Lubricator FIG 1

Use „Calculation Pro“ to choose correct dispensing time and lubricator size.
(“Calculation Pro” is available at www.simatec.com, in the App Store, and in the Android Market.) Clean lubrication point

Remove connector nipple and screw in quick connection coupling simalube
27764029 Automatic Single-Point Lubricator FIG 4

Connect hose and prefill with a grease gun
(fill tubes completely)

Install and activate simalube and IMPULSE

Connect hose to mounting bracket

Seal IMPULSE and screw onto lubrication point
ATTENTION : IMPULSE logo must face the front

Cut off plug from lubricator or remove black plug

Activate calculated dispensing time with 3 mm Allen key

Write in activation date

Insert the battery pack

Screw on lubricator, device will be activated, green LED will blink 2x. The first pump cycle will begin within 30 seconds

Check simalube and IMPULSE regularly

Replace and recycle the lubricator

Replace or refill the empty lubricator

a) Remove cover disk
b) Remove gas generator with a socket wrench (SW21 mm)

Dispose of intact gas generator in battery recycling and empty housing in plastic recycling.
(Warning: dispose of leftover grease separately) simalube 27764029 Automatic
Single-Point Lubricator FIG 16

Remove the used battery pack and replace it with a new one

Put IMPULSE with new lubricator into operation

Check and clean the gasket IMPULSE remains on lubrication point

Screw refilled or new lubricator onto the lubrication point

Period of use of the simalube IMPULSE:

simatec ag
Stadthof 2
CH-3380 Wangen a. Aare
Tel.: +41 (0)32 636 50 00
Fax.: +41 (0)32 636 50 19
welcome@simatec.com
www.simatec.com 