Product Information

  • Product name: Kamera Termowizyjna KT-128 KT-256 KT-256F
  • Manufacturer: SONEL S.A.
  • Version: 3.00
  • Date: 31.05.2023

Product Usage Instructions

  1. Safety Symbols: The following symbols are used on the device and/or in this manual:
    • Do not dispose with household waste
    • Caution, laser radiation. Class 2 laser device. Risk of eye injury
  2. Safety: Please follow the safety guidelines below when using the camera:
    • Do not use the camera in rooms with special conditions, such as explosive or fire-prone atmospheres.
    • Do not use the camera if it is partially or completely malfunctioning.
    • Only use the provided power supply. Repairs should only be performed by authorized service centers.
    • Avoid exposing the thermal camera to dust and moisture. Make sure it is adequately protected from splashing when used near water.
    • When the thermal camera is not in use or being prepared for transport, store the device and its accessories in a protective case.
    • Wait at least 15 seconds before turning on the camera again after turning it off.
    • Avoid throwing, hitting, or shaking the camera and its accessories intensively to prevent damage.
    • Only use the provided SD memory card.
    • When transferring the camera from a warm place to a cold place, or vice versa, it is recommended to turn off the camera and leave it in the new location for approximately 60 minutes before turning it on. Rapid temperature changes can affect temperature measurement accuracy and even damage the infrared sensor.

USER MANUAL
THERMAL IMAGER KT-128 KT-256 KT-256F
SONEL S.A. Wokulskiego 11 58-100 widnica
Poland
Version 3.00 31.05.2023 23

Thank you for purchasing our thermal camera. KT camera is a modern, easy and safe measuring device. Please acquaint yourself with the present manual in order to avoid measuring errors and prevent possible problems related to operation of the camera.
All products of Sonel S.A. are manufactured in accordance with Quality Management System which is approved to ISO9001:2008 for the design, manufacturing, and servicing. Due the continuous development of our products, we reserve the right to introduce changes and improvements in the thermal imaging camera and in the software described in this manual without prior notice. Illustrations presented in this manual may slightly differ from the real product.
Copyrights © Sonel S.A. 2023. All rights reserved.

General information

Safety symbols
The following international symbols are used in the device and/or in this manual:
Declaration of Conformity with EU directives (Conformité Européenne)
Do not dispose of with other household waste
Caution, laser radiation. Class 2 laser device. Risk of eye irritation.

Safety

Before you proceed to operate the camera, acquaint yourself thoroughly with the present manual and observe the safety regulations and specifications defined by the producer.
Any application that differs from those specified in this manual may re-
sult in damage to the device and constitute a source of danger for the user.
The camera must not be used in rooms where special conditions are
present e.g. fire and explosion risk.
It is forbidden to use damaged or malfunctioning camera. Do not use any other adapter than the one supplied with the camera. Repairs may be performed only by an authorised service point.

KT-128 / 256 / 256F thermal camera is designed to measure and record the images in the infrared. It is designed to provide the user with maximum performance and safety during the work. However, the following guidelines and recommendations must be observed at all times (in addition to all binding precautions applicable at individual work stands and work areas):

26

KT-128 KT-256 KT-256F ­ USER MANUAL

Keep the camera steady when performing the measurements. Do not use the camera in temperatures exceeding its working and
storage temperature ranges.
Do not direct the camera toward very high intensity radiation
sources such as the sun, lasers or welding arcs etc.
Do not expose the camera to dust and moisture. When operating the
device near water, ensure that it is adequately guarded against splashes.
When the camera is not in use or is to be transported, ensure that the
unit and its accessories are stored in the protective carry case.
Do not re-switch on the camera until 15 seconds later after switching it
off.
Do not throw, knock or shake intensely the camera and its compo-
nents in order to avoid the damage.
Do not attempt to open the camera body, as this action will void the
warranty.
Use only the SD memory card supplied with the camera. During operation, if the camera is to be moved from hot/cold place to
cold/hot place, e.g. from inside/outside to outside/inside of a room, switch off the camera and leave it in the new workplace for ca. 60 minutes. Only after that time, turn it on and start normal operation with an accurate temperature measurement. Sudden and rapid changes in ambient temperature may cause fault temperature measurement and even damage camera’s IR detector.
Calibration of the detector ­ during operation, the camera performs au-
to-calibration from time to time, which takes approx. 2 seconds.
Due to continuous development of the instrument’s software,
the actual appearance of the display may slightly differ from the display presented in this manual.
To maintain required parameters of rechargeable batteries,
unused rechargeable batteries should be charged every 3 months.

KT-128 KT-256 KT-256F ­ USER MANUAL

27

CAUTION!
KT-128 / 256 / 256F thermal camera has no parts that could be
repaired by the user. Never attempt to disassemble or modify the camera. Opening the device will void the warranty.
Use only accessories listed in section 12. Using other acces-
sories does not ensure proper operation of the camera and may cause its damage.
WARNING
LASER RADIATION DO NOT STARE INTO THE BEAM
OF THE LASER DIODE —————————————————————-
Wavelength 645-655 nm Max. output power <1 mW
Class 2 laser product
Do not point your eyes toward the laser beam. Laser radiation poses hazards to unprotected eyes. It is neces-
sary to use protective goggles.

28

KT-128 KT-256 KT-256F ­ USER MANUAL

Functional description

The imager

Visual lens IR lens Laser pointer LED flashlight
Autofocus button Trigger button USB socket Memory card slot

Strap holder Tripod mount LCD display UP button MENU button DOWN button POWER button

KT-128 KT-256 KT-256F ­ USER MANUAL

29

Display

After turning on the camera, the infrared image is displayed in real time on the screen.
The temperature of the ob-
ject is displayed for the whole time (upper left corner).
Depending on the settings
made according to sec. 6, the screen may also display the central point or measurement area showing temperatures: maximum and minimum.
If the laser pointer is activat-
ed, as described in sec. 6, an indicator will be displayed next to the battery symbol.

The following image modes are available:

IR ­ infrared image,

VL – visual image from the camera,

MIF ­ infrared image combined with visual

image,

PIP ­ visual image with superimposed IR image, including the

central point or measurement area.

The mode can be switched using buttons. Confirm the selection by pressing button. Exit MENU by pressing button.

30

KT-128 KT-256 KT-256F ­ USER MANUAL

Quick start

Turning the camera ON/OFF

In order to switch the camera on, press and hold

button for

more than 3 sec. The camera will display the welcome logo and

commence the start-up, including the self-check. After completing the

self-check, the camera is ready to work and enters the mode of real-

time display of infrared image.

To switch OFF the camera press and hold screen goes blank.

button until the

In order to obtain the correct indications, the camera must stabilize them. Stabilization may take ca. 10 minutes after the instrument is turned on.
3.2 Capturing and saving images
In the real-time image mode, point the camera into the direction of
the tested object.
Press and hold the trigger – the laser pointer will be activated
to facilitate finding the target (if the laser is turned on – see. sec. 6).
Release the trigger – the image is frozen. Select [] ( button) to save the thermal image or [x] ( but-
ton) to cancel saving.
Then, the camera returns to real-time image mode.

KT-128 KT-256 KT-256F ­ USER MANUAL

31

Autofocus
For a sharp image, press the trigger .

32

KT-128 KT-256 KT-256F ­ USER MANUAL

Special features

4.1 Floodlight

To turn on/off the floodlight:

enable the appropriate option in Menu Floodlight.

press and hold button .

4.2

Temperature scale level

and range

The temperature scale can be adjusted in three ways: automatic (A), semi- automatic (S) and manual (M).

Press and hold button

to enter the settings. Each successive

press of switches the scale adjustment mode in the order of

A, S, M.

o Semi-automatic mode (S) ­ in this mode, you can set the T
value, i.e. the difference between the maximum and minimum
temperature value on the scale.

To increase the T value, use the buttons and select the “” arrow in the interface, then press .

To decrease the T value, use the buttons and select the “” arrow in the interface, then press .

KT-128 KT-256 KT-256F ­ USER MANUAL

33

o Manual mode (M) ­ in this mode you can set the maximum
(Tmax) and minimum (Tmin) temperature on the scale. To increase Tmax and Tmin at the same time (i.e. move the scale up), use the buttons and select the “” arrow on the interface, then press button . To decrease Tmax and Tmin at the same time (i.e. move the scale down), use the buttons and select the “” arrow on the interface, then press button . To decrease Tmax and increase Tmin at the same time (i.e. narrow the scale), use the buttons and select the “” arrow on the interface, then press button . To increase Tmax and decrease Tmax at the same time (i.e. broaden the scale), use the buttons and select the “” arrow on the interface, then press button .
o Auto Mode (A) ­ in this mode, Tmax and Tmin are set auto-
matically based on the real-time image. They cannot be adjusted manually.
Press button to save and exit the settings.
4.3 Image capture mode
To use this mode, you need to use an external PC video capture application.
Install a video capture program on your computer. Connect the camera to the computer using the USB cable. In the application, select the image capture mode.

34

KT-128 KT-256 KT-256F ­ USER MANUAL

4.4 Files ­ viewing, deleting

Briefly press the button to access the menu interface.

Using

buttons select Gallery and Review. Photo list will

appear.

To display another photo press .

In order to delete a photo, press briefly the

button, use but-

tons to select [] and confirm your selection with button.

4.5 Files ­ transfer to the computer
In order to transfer thermal images to a computer, connect the camera via a USB cable or install the camera memory card in the computer. The detected memory will show desired files.

4.6 Restoring factory settings
In order to restore the settings to the factory defaults, go to Menu Reset and press the button to confirm the reset.

4.7 Formatting the SD card
In order to wipe the SD card, go to Menu Format SD and press the button to confirm the formatting.

KT-128 KT-256 KT-256F ­ USER MANUAL

35

Troubleshooting

Problems Causes

What to do

Boot failure.

Low battery.

Reuse battery after charging.

External power source plug is Pull the plug and reinsert it

not inserted properly.

properly.

IR image is not clear.

Lens is misted up or dirty.

Clean lens.

Niewyrany obraz wizualny

Zbyt ciemne otoczenie.
Obiektyw jest zaparowany lub brudny.

Zapewni owietlenie. Wyczy obiektyw.

Imprecise temperature measurement

Emissivity and/or the distance from the object incorrectly set.

Change the parameters.

A long time without calibration.

Order the calibration of the camera from the manufacturer.

36

KT-128 KT-256 KT-256F ­ USER MANUAL

6 Menu, settings, functions

Press

to enter setting menu. Using buttons highlight items.

Enter them and change their value using . Go back using .

Following items are available:

Gallery ­ go to images list,

TempRange ­ display temperature measurement range,

Emissivity ­ changing the emissivity of the tested object.

Palette – selecting the colour palette.

CenterPoint – turning on/off the central point on the screen.

TempUnit ­ temperature unit: ºC or ºF.

ReflMeasure ­ measurement area.

Alarm ­ temperature alarm: setting upper and lower threshold tem-

perature. Use buttons to set the temperatures.

ReflMeasure ­ ambient temperature. Use buttons to set the

temperature.

Distance ­ the distance from the tested object. Use buttons to
set the distance.

Distance unit.

AutoShut ­ automatic shutdown: disabled or 5, 10, 15 min.

ScreenBright ­ low/medium/high screen brightness.

Laser ­ laser pointer on/off.

Floodlight ­ flashlight on/off.

Date/time.

Language.

Reset ­ use buttons to select command.

Format SD ­ use buttons to select command.

PIPtransparent ­ transparency of superimposed IR image: 0%,
30%, 60%, 90%.

Visual ­ shows visual images in Gallery.

USBMode ­ operating mode when connected to an external device
via a USB cable: file transfer/image capture.

Camera info.

KT-128 KT-256 KT-256F ­ USER MANUAL

37

7 Power supply, battery charging

The camera is powered by an internal rechargeable battery. It may be also powered using the AC adapter.

In order to charge a KT camera, just plug in the AC adapter to the camera USB socket when it is switched off. Charging does not take place during operation of the camera.

If the camera is to be inactive for a long time, it is recommended to recharge the rechargeable battery every 3 months.

Store the half-charged battery pack in a dry, cool and well venti-
lated place and protect them from direct sunlight. The battery pack may be damaged if stored when fully discharged. The ambient temperature for prolonged storage should be maintained within the range of 5°C…25°C.
Charge the batteries in a cool, well-ventilated place at a tempera-
ture of 10°C…28°C. Modern fast chargers detect both too low and too high temperature of rechargeable batteries and react to the situation adequately. When the temperature is too low, charging should be prevented as it may irreparably damage the batteries. The increase in temperature of the battery pack may cause electrolyte leakage and even its ignition or explosion.
Do not exceed the charging current, as it may result in ignition or
“swelling” of the battery pack. “Swollen” battery pack must not be used.
Do not charge or use the batteries in extreme temperatures. Ex-
treme temperatures reduce the lifetime of rechargeable batteries. Always observe the rated operating temperature. Do not dispose the battery pack into fire.
Li-Ion cells are sensitive to mechanical damage. This kind of
damage may cause their permanent damage and thus ­ ignition or explosion.
Any interference in the structure of Li-ion battery pack may cause
its damage. This may result in the ignition or explosion.

38

KT-128 KT-256 KT-256F ­ USER MANUAL

A short-circuit of the battery poles “+” and “-” may permanently
damage the battery pack or even cause its fire or explosion.
Do not immerse Li-Ion battery in liquids and do not store in humid
conditions.
If the electrolyte contained in the Lithium-Ion battery pack, con-
tacts eyes or skin, immediately rinse the affected place with plenty of water and consult a doctor. Protect the battery against unauthorised persons and children.
When you notice any changes in the Lithium-Ion battery pack (e.g.
changes in colour, swelling, excessive temperature), stop using the battery pack. Li-Ion batteries that are mechanically damaged, overcharged or excessively discharged are not suitable for use.
Any misuse of the battery may cause its permanent damage. This
may result in the ignition. The seller and the manufacturer shall not be liable for any damages resulting from improper handling LiIon battery pack.

KT-128 KT-256 KT-256F ­ USER MANUAL

39

8 Cleaning and maintenance
NOTE!
Use the below specified methods of maintenance only. The thermal imager does not comprise any parts service-
able by the user. Do not at-tempt to dismantle or modify the camera on your own. Opening the instrument voids the warranty.
Camera enclosure ­ all surfaces, except for optical elements of
the camera, can be cleaned with a soft and moist cloth with generally available mild detergents. Do not use any solvents or cleaning agents that could scratch the enclosure (powder, paste, etc.). During cleaning, the camera must be turned off.
Due to the applied anti-reflective coating, optical lens are the most
sensitive and at the same time the most expensive part of the camera (the lens is of key importance to radiometric capabilities of the infrared system). Optical surfaces should be cleaned only, when they are visibly fouled. Do not touch exposed surfaces of optical lens with fingers, because fouling left with fingerprints can be harmful to coatings and glass of the lens.
Chemical agents must not be used for cleaning the optics and ac-
cessories of the camera. Use a clean, dry and soft cloth.

40

KT-128 KT-256 KT-256F ­ USER MANUAL

9 Storing
When storing the instrument, observe the following guidelines:
make sure the camera and its accessories are dry, allowed are storage temperatures specified in technical specifica-
tions,
in order to avoid complete discharging of rechargeable batteries
during prolonged storage, charge them once in a while (recommended time: 3 months).
10 Dismantling and disposal
Used-up electrical or electronic equipment must be collected se-
lectively, i.e. must not be mixed with waste of other types.
Used-up electronic equipment must be delivered to an appropriate
collection centre in accordance with regulations related to used-up electrical or electronic equipment.
Before delivering the equipment to the collection centre do not at-
tempt to dismantle any of its parts.
Follow local regulations related to disposing of packaging, used-
up batteries and rechargeable batteries.

KT-128 KT-256 KT-256F ­ USER MANUAL

41

Detector resolution Spectral range Frame rate Thermal sensitivity Focus IFOV Min. focus distance Lens (field of view/focal length)
Display Image modes
Temperature range
Accuracy
Image analysis modes Palettes Emissivity Measurement adjustment File format Built-in features Interface
Power supply
Operating temperature Storage temperature Ingress protection Certification Weight Dimensions

Specifications

KT-128 Camera
120 x 90 / 17 µm VOx

60 mK
7.6 mrad 0.5 m

Fixed

KT-256

KT-256F

256 x 192 / 12 µm VOx

7.5~14 µm

25 Hz

45 mK

Auto

3.75 mrad

1.71 mrad

0.3 m

0.5 m

50° x 38°/2.28 mm

56° x 48°/3.2 mm

25° x 19°/7 mm

Image

2.4″ 240 x 320 px LCD

IR / Visual / PiP

IR / Visual / Infrafusion MIF / PiP

Temperature measurement

Range 1: -20°C…+150°C

Range 1: -20°C…+150°C

Range 2: 100°C…+400°C

Range 2: 100°C…+550°C

±2°C or ±2% of reading

(for ambient temperature 15°C…30°C, object temp. 0°C)

Functions

Point. 3 areas. Temperature indication: min, max. Temp. alarm

6

Selectable from 0.01 to 1.00 or from the list

Adjustable distance, ambient temperature (reflected)

JPG

Visual camera 2 MPix, LED flashlight, laser pointer

SD card slot (max. 32 GB), USB type C, tripod

Li-Ion battery (over 5 h of

Li-Ion battery (over 16 h of continuous operation),

continuous operation),

built-in charger (max. charging time 2.5 h),

built-in charger (max.

AC adapter 110-230 V (50/60 Hz)

charging time 2.5 h),

AC adapter 110-230 V

(50/60 Hz)

Environmental conditions

-10°C…50°C

-15°C…50°C

-40°C…70°C

IP54

CE, ROHS, FCC

approx. 0.35 kg

approx. 0.38 kg

194 x 61.5 x 76 mm

42

KT-128 KT-256 KT-256F ­ USER MANUAL

12 Accessories
The current list of accessories can be found on the manufacturer’s website.

12.1 Standard accessories

Standard bundle supplied by the manufacturer includes:

KT-128 / 256 / 256F Thermal Imager

USB charger ­ WAZASZ20

Type C USB cable ­ WAPRZUSBC

16 GB microSD card ­ WAPOZMSD16

32 GB microSD card ­ WAPOZMSD32

Wristband ­ WAPOZPAS1

User manual

Declaration of verification

Optional accessories

Additionally, the following items that are not included in the scope of standard equipment can be purchased from the manufacturer or the distributors:
Calibration certificate with accreditation

KT-128 KT-256 KT-256F ­ USER MANUAL

43

Manufacturer
The manufacturer and provider of warranty and post-warranty services for this instrument is:
SONEL S.A. Wokulskiego 11 58-100 widnica
Poland tel. +48 74 858 38 60 fax +48 74 858 38 09 e-mail: export@sonel.pl web page: www.sonel.pl
NOTE!
Only the manufacturer is authorized to perform service repairs.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals