NARVI KAAMOS 20 Wood Burning Sauna Heater Instruction Manual

June 1, 2024
NARVI

NARVI KAAMOS 20 Wood Burning Sauna Heater

NARVI-KAAMOS-20-Wood-Burning-Sauna-Heater-product

Product Information

Specifications

  • Width: 480mm
  • Depth: 500mm
  • Height: 760mm
  • Weight without stones: 65kg

Frequently Asked Questions

  • Q: How often should I clean the ash from the sauna heater?
    • A: It is recommended to clean the ash regularly, ideally after each use or at least once a week, to maintain optimal performance.
  • Q: What type of firewood should I use?
    • A: Use split firewood with specific dimensions for efficient heating, as mentioned in the user manual.

Before You Start

Please read the manual carefully before you start installing and using it and keep the manual for future reference. The products are meant only to be used as a sauna heater and for heating the sauna.

Technical data| Width (mm)| Depth (mm)| Height (mm)| Adjustment range

± (mm)

| Weight without stones (kg)| Volume of the water tank| Weight of the stones Ø 10–15 cm (kg)
---|---|---|---|---|---|---|---
KAAMOS 20| 480| 500| 760| 15| 65| –| 60

INTRODUCTION

Thank you for having chosen our continuous burning Narvi Kaamos sauna heater. To make the most of your sauna heater please read the manual carefully before you start installing and using it and keep the manual for future reference. This user manual contains technical data of your sauna heater and installation, use and maintenance instructions.

The product is only meant to be used as a sauna heater and for heating the sauna. Do not modify the design of the sauna heater and use only spare parts and accessories recommended by the manufacturer. The data plate included in the delivery of the sauna heater must be glued on the sauna heater, preferably on the lower part of the cover of the sauna heater.

Do not heat the sauna heater if you lack suffi-client knowledge, if you are not allowed to use sauna because of your health condition or you are under the influence of substances causing intoxication. Sauna heaters must not be used by underage people. Do not leave children in the sauna without supervision. A sauna is not meant for drying clothes.

Follow the instructions!

INSTALLATION INFORMATION FOR HEATER




Heater model

| Sauna room| Minimal safety clearances to the heater (to combustible materials)| ****

Connection

| ****


Thickness of the cover of the

furnace (mm)

| ****



Flue gas mass flow (g/s)

---|---|---|---|---|---




Volume (m3)

| ****



Sides (mm)

| ****



Front (mm)

| ****



Top (mm)

| ****



Back (mm)

| ****


Diameter of the connective flue (mm)

| ****

Distance of the bottom edge of the connective flue from the floor (mm)

| ****

Central point of the connection from the above from the rear edge of the sauna heater (mm)

KAAMOS 20| 10–20| 300| 500 *)| 1270| 200| 119| 555| 115| 10| 16,2

*) We recommend leaving 1000 mm maintenance area in front of the sauna heater.

BEFORE YOU INSTALL THE SAUNA HEATER

Before installing and using the sauna heater, make sure you are thoroughly familiar with the requirements for installing the sauna heater in the steam room. In case of questions and for additional information do not hesitate to contact the Rescue Board or a construction supervision authority. When installing fireboxes all local laws have to be followed, including these referring to local and European standards.

STEAM ROOM

If the walls of a steam room are made of uncovered glass, brick or concrete add 0.8–1.5 m3 per square meter of such wall and the final choice of the heater shall be made based on the sum of the area. If the heater is installed in a sauna that is normally not heated or the sauna is made of massive logs, multiply the sauna area with 1.5 and choose the heater based on this. The recommended area of a steam room is indicated in clause 1.1. Please follow the values for the minimum area stipulated for the steam room.

We recommend choosing a sauna heater with a slightly bigger power to ensure proper heating of the sauna and to avoid heating the sauna heater to its upper limit. A slightly bigger power ensures longer lifetime of the sauna heater and provides better steam thanks to bigger quantity of stones.

SUBSTRATE

A firebox must be installed on the floor with sufficient load-bearing capacity. The durability of the floor must be checked especially carefully, when the sauna heater is installed on a wooden floor. The weight of the sauna heater is shown in clause 1.1. If the existing floor does not meet this prerequisite, suitable measures (e.g. load-distributing plate) shall be installed to achieve it.

Concrete floor

The sauna heater may be installed directly on a concrete floor, which is at least 50 mm thick. If underfloor heating cables or pipes are located under the sauna heater, Narvi installation base must be used to protect them from the thermal radiation of the sauna heater.

Floor made of combustible material or a tiled floor, underfloor, underfloor heating

  • A Narvi installation base must be installed under the saunaheater, which will protect the floor, moisture barrier and underfloor heating pipes or cables from the thermal radiation of the sauna heater.

SAFETY CLEARANCES

  • When installing the sauna heater, safety clearances must be considered with.
  • Ignorance of safety clearances causes fire hazard. If required, additional information can be obtained from the regional branch of the rescue board.

STRUCTURE MADE OF COMBUSTIBLE MATERIALS

  • The safety clearances are the minimum allowable distances between the sauna heater and structures made of combustible materials. Please observe the stipulated requirements regarding walls, floors, sauna benches, other inventories and storage areas of firewood!
  • Rear and side safety distances can be shortened by using Narvi protective wall shields. Our dealers can provide more info regarding suitable safety walls for sauna heaters.
  • Please observe that the safety clearance of an uninsulated smoke flue from structures made of combustible materials is 1000 mm or any other distance stipulated in the manufacturer’s instructions.

Protecting a floor made of combustible material

Figure 1. If the sauna heater is installed on a floor made of combustible materials, an installation base must be used. A piece of sheet metal must be installed in front of the installation base, which extends at least 100 mm over the sides of the heater door and at least 400 mm in front of the sauna heater. The sheet metal edges facing the sauna heater must be turned up, so that coal cannot get under the installation base.

NON-COMBUSTIBLE STRUCTURE

If the wall is masonry or other structure classified as non-combustible, it is sufficient to have a 50 mm air gap between the upright surfaces and the wall. If the sauna heater is installed inside a wall recess of non-combustible material, a 100 mm air gap is required to ensure proper air circulation.

SMOKE FLUE

  • A smoke flue of the sauna heater must meet the requirements of class T600 irrelevant of the material of the smoke flue. The minimum recommended draft of the smoke flue is 12 Pa. Stove door closed.
  • A modular smoke flue must meet the requirements of class T600 and provided with CE-marking. When installing a modular smoke flue safety clearances stipulated in the installation manual of the smoke flue shall be followed. The minimum recommended diameter of a modular smoke flue is 120 mm. The weight of the smoke flue must not cause load on the sauna heater. The sauna heater should be connected to a separate smoke flue. A smoke flue made of bricks must be at least the so-called half-brick smoke flue.

VENTILATION

  • Ventilation of the steam room should be sufficiently efficient and should function so, that fresh incoming air is routed as close to the sauna heater as possible. Also proper air circulation has to be provided in the steam room during using the sauna so that air can exit from under the sauna bench or from under the door of the washing room (sufficient gap).
  • Other possible fireplaces that are used simultaneously must be considered, and make sure there is enough replacement air. Extraction fans working in the same room as the firebox may cause problems. Inlets of incoming air should be located so that they do not get blocked (for instance because of snow). A firebox needs combustion air in a volume of 6–10 m3 per kilo of fired wood. The diameter of the ventilation opening must be at least 100 mm. Forced air system should be built according to the design prepared by the designer of the heating, water and ventilation systems.
  • There shall be a possibility to ventilate sauna rooms after using the sauna and to dry the rooms so that air will exit via the upper part of the steam room.

Figure 2. Ventilation in sauna room

NARVI-KAAMOS-20-Wood-Burning-Sauna-Heater-fig-2

  1. Oxygen rich steam
  2. Incoming fresh air
  3. Chimney outlet
  4. Outgoing air

INSTALLATION AND PREHEATING OF THE SAUNA HEATER

PREHEATING

Before use and arranging the stones, the sauna heater must be heated to remove the protective agents. Any protective films and stickers must have been removed before. Preheating shall be carried out (on a non-combustible surface) outside, since paint emits harmful solvent vapours and smoke during the heating. Use of a connection pipe included in the delivery of the sauna heater in the upper joint (see item 1 of the attached drawing) improves draft during preheating. 1–2 fireboxes of wood are sufficient for preheating.

After preheating and before arranging the stones loose cover material should be removed from the stone compartment of the sauna heater with a steel brush. In case the external surface of the sauna heater is painted, it should not be rubbed or wiped before the
first heating. The paint of the sauna heater will achieve sufficient strength only after the first heating. Do not create steam during the first heating.

REGULATION OF THE HEIGHT

  • The legs of the sauna heater are adjustable and can be used for levelling the sauna heater and for adjusting the height.
  • There must be an air gap of at least 25 mm between the sauna heater and the floor. Use a spirit level to check if the sauna heater is level.

CONNECTION WITH THE SMOKE FLUE

The sauna heater can be connected to the smoke flue from the back or top of the sauna heater. Seal the unused opening with the supplied cover. The sauna heater comes with a short smoke flue connection pipe, which can be used to connect the smoke flue of the sauna heater from the back. Only a straight connective flue without extra parts can be used, when the flue is connected from rear. If the connection with the smoke flue is done from the above, Narvi connective flue or Narvi smoke flue must be used. In case of connection from the above, a Narvi smoke flue tank for heating water or a Narvi stone basket can be installed around the connective flue.

Do not push the connective flue too deep in the smoke flue, because this would hinder the draft. Any leaks in the connective flue also reduce the draft; therefore, the connections must be sealed with fireproof sealing material. Leakage in the connective flue cause combustion gases formed in the sauna heater to ignite in the flue. The connection joint of the flue and the sauna heater must be 25 mm. The diameter of the connective flue of the sauna heater and the height from the floor are shown in clause 1.1. Please consider with the clearance distance of the modular smoke flue, see the manufacturer’s instructions.

  • Item 1. Main connection of the smoke flue
  • Item 2. Cleaning hatch
  • Item 3. Stones to be installed under the smoke channel and central opening

INSTALLATION OF A DOOR AND CHANG-ING OF THE OPENING DIRECTION OF THE DOOR

Figure 4. Open the door and raise the hinge pin up so it comes out of the bottom hinge barrel. Hold onto the door securely and turn the bottom part of the pin and turn the bottom end of the pin up enough (2) that you can pull the pin down (3) and the pin and door come apart. For installation proceed in reverse order. First push the upper edge of the door in its place and thereafter push the pin through the upper eyelet. Thereafter turn the door and pin in their places from below and let the pin into the bottom eyelet. The pin is correctly installed when the wider areas of the pin are facing down. In this case the pin cannot move away from its place. Door installation is easier when you use long flatnose pliers.

SAUNA HEATER STONES

We recommend that you use Narvi olive dolerite stones. Natural stones are not suitable to be used as sauna heater stones 10–15 cm. Before using the stones, they must be washed to elim-inate any impurities. Bigger stones are placed in the bottom of the stone compartment and the rest are piled sparsely so that air can move freely between the stones. Flat stones shall be stacked in upright position. The stones must not block air openings and stones must not be stacked over the top surface of the sauna heater. The recommended quantity of stones in the sauna heater is shown in clause 1.1. The use of stones with a regular shape (rectangular, etc.) and light or ceramic stones is forbidden because of a risk of too tight stacking.

USING THE SAUNA HEATER

FIREWOOD

Only use natural wood logs as fuel. Both hardwood and softwood can be used to heat the sauna heater. The use of chipboard, fibreboard, briquet, pellet, painted or impregnated wood, waste or plastic is prohibited. To ensure clean burning and the largest possible efficiency, the wood must be dry. The moisture content of the wood must be less than 20%. Normally good firewood is sticks of wood the diameter of which is around 5 cm, length around 33 cm and weight around 0.5 kg. Use of liquid fuel is strongly forbidden, also during ignition!

HEATING

Before heating, make sure that there is no com-bustible material within the safety clearances. Also make sure that the ash drawer and fire grate are clean and if the sauna heater is provided with a water tank, that it is filled with clean water. Check if there is sufficient draft in the smoke flue. If you hesitate regarding the draft, check it by burning a small quantity of paper in the firebox first. During heating the door of the firebox must be closed and the water tank must be filled with water. The sauna heater must not be covered with anything.

To start heating pile firewood over a sufficiently wide area and ignite it from above. For ignition you may use birch bark or paper. Ignition aid should be placed between the upper firewood and it can be topped with some thinner wood sticks or firewood (see figure 5). Igniting from above reduces pollution and ensures cleaner burning.

The power of the sauna heater can be regulated with the ash drawer. If the ash drawer is closed, the power of the sauna heater is at its lowest and the burning time is longer. If the sauna heater soughs too much, reduce the draft. To do this close the ash drawer half way or completely. This way heat reaches better the sauna heater, stones can store heat and you do not just heat up the flue. A calm flame is a sign of a correct draft. Avoid heating the sauna heater so that the channels of the stone basket glow red for a long time because this will overload the firebox and the service life of the sauna heater will be reduced. Overheating may also cause excessive heating of the smoke flue and cause fire hazard. The connective flue pipe must not be glowing red.

The following table shows the recommended quantities of firewood for sauna heater and positions of the ash drawer. The values shown in the table meet the values of the nominal power test pursuant to the standard EN15821. In the test the size of the sauna was determined based on the maximum area for the given sauna heater and temperature of 90 °C was achieved in the sauna. During first times we recommend using less firewood for achieving the desired temperature than the values presented in the table. Maximum quantity of firewood per hour (max. kg/h) indicated in the table must not be exceeded.

Do not stack firewood in the firebox over 2/3 of its height. Quantities of firewood are shown in clause 4.1. In the ignition phase the ash drawer can be kept open by 10 mm more than indicated in the table. After igniting put the ash drawer back in the position as shown in the table.

HEATING OF THE SAUNA

  KAAMOS 20

1. FIREBOX OF FIREWOOD (sticks of firewood with a diameter around 5 cm, length around 33 cm and weight around 0.5 kg)
quantity of firewood (kg)| 3,5
opening of the ash drawer (mm)| 20
1ST ADDITION OF FIREWOOD
quantity of firewood (kg)| 3
opening of the ash drawer (mm)| 10
2ND ADDITION OF FIREWOOD
quantity of firewood (kg)| 2,5
opening of the ash drawer (mm)| 10
MAX KG/H| 7

Do not forget that the sauna heater and its part become very hot during heating. Always use gloves or other hand protection when being in touch with the parts of the heater.
When moving around in the sauna be careful, because the floor and the ceiling of the sauna may be slippery.

Be careful – water in the water tank of the sauna heater may be very hot

One firebox of firewood burns approximately half an hour. Good time for adding firewood is when there are still some blue flames on coal in the firebox. Before adding firewood you may even slightly coal on the grate. If firewood is added in the flames too early, the temperature of fume gases increases. Do not use the door to push firewood in the firebox.

In case sauna is used or the sauna heater is heated also after recommended number of times firewood should be added as stated in the table, firewood should not be added according to the quantities mentioned in the table. A proper quantity for keeping heat is 1-2 logs (approximately 1 kg of firewood) every half an hour. The ash drawer may be closed a bit. If you add a big quantity of firewood, the temperature of flue gases rises and this can damage the smoke flue and cause fire hazard. But do not heat continuously over 3 hours. Thereafter, the sauna heater must be let cool down before the next heating.

In case sauna will not be used any longer and coal is still glowing without flame, extinguishing can be speeded up by increasing the draft. For this open the ash drawer by 10-20 mm. There is enough heat accommodated in the stones of the sauna heater to dry the sauna room. In ignition phase the closing pan must be fully open. Before you close the closing pan after heating, check that there is no glowing coal in the firebox. Otherwise fumes may be released in the sauna. Carbon monoxide is an odourless and colourless toxic gas.

If you have not used the sauna heater and smoke flue for a longer period or it is cold, please check before use that the smoke flue is in proper order and that there are no corrosion damages on the sauna heater. Start heating very slowly and with small quantity of firewood so that not to damage the smoke flue. In case of malfunction, stop the heating immediately and close the fireplace and ash box doors.

STEAM WATER

Use normal domestic water for steam water.
Quality requirements for domestic water:

  • humus content < 12 mg/l
  • iron content < 0.2 mg/l
  • calcium content < 100 mg/l
  • manganese content < 0.05 mg/l

Do not use sea water or other salty water.

Also do not use water containing chlorine. The warranty of the sauna heater does not cover damages caused by the use of unsuitable steam water. Do not throw water on the stones, if you yourself or somebody else is straight by the sauna heater. Hot water steam may cause burns.

REMOVING THE ASHES

The ash drawer must be emptied every time before heating the sauna heater. The ash drawer must be emptied immediately, if ashes fill more than half of the drawer. Otherwise, the airflow through the firebox grate will be hindered, which will shorten the life of the grate. The ash drawer must be emptied in a non- com-bustible container (for instance metal bucket) after ash has cooled down. Do not leave the ash bucket standing by the wall (for instance on the terrace). If the smoke flue is equipped with a closing pan, it should be opened for the time ash is removed. Dust will escape with the draft.

MAINTENANCE OF THE SAUNA HEATER

The fireplace, the connective flue and the chimney must be swept regularly. Cleaning and sweeping of the chimney is important especially if the fireplace has not been used for a longer period. Besides removing the ashes and having the chimney annually cleaned by a chimney sweep, the sauna heater requires no other maintenance. The condition of the heater should be monitored, and usage must be terminated immediately if deviation is recognized. chimney sweepers are qualified to estimate the condition, and it helps the inspection if the stones are removed before. To open the cleaning hatch of the sauna heater, the upper stones have to be removed from the sauna heater.

The stones of the sauna heater have to be rear-ranged once per year and replaced every other year. Cracking stones collapse and fall lower, some stones will erode. Remove eroded and broken stones. Due to insufficient maintenance the sauna heater needs more time for heating, which in its turn causes load on the structure of the sauna heater. The surface of the sauna heater should be cleaned regularly with a damp cloth.
Also the water tank of the sauna heater should be regularly cleaned. Use only clean water to fill the tank. If there is a danger that water can freeze, the water tank should be emptied.

DISPOSAL

  • For disposal take the sauna heater to the public waste recycling centre.

SOOT FIRE

Warning: IN CASE OF SOOT FIRE (ALSO IF IT HAS ALREADY BEEN EXTINGUISHED) ALWAYS INFORM THE EMERGENCY CENTRE!

  • If you detect soot fire in the smoke flue, close immediately the ash drawer and the door of the firebox.
  • After sooth fire and before the next use of the sauna let a chimneysweeper check the condition of the smoke flue and the sauna heater.

FREQUENTLY ASKED QUESTIONS

The sauna heater is drafting poorly

  • The sauna heater has not been used in a long time; the smoke flue and sauna heater are damp.
  • The sauna heater is not receiving sufficient air; there is a downdraft in the sauna caused by ventilation. Underpressure can be caused for example when the kitchen hood is used.
  • The sauna heater has not been cleaned in a long time.
  • The ash drawer is closed or full of ashes.
  • Leakage in the connective flue.

The sauna does not heat up properly

  • The firewood is damp.
  • The sauna heater has insufficient power.
  • The sauna heater or smoke flue is drafting poorly.
  • The stones of the sauna heater are dirty or crumbling or stacked too tight.
  • There are too many stones or there are too many small stones.

The sauna heater smells

  • The sauna heater has not been properly heated the first time it was done.
  • The stones of the sauna heater were not washed before loading.
  • Fats or other dirt has accumulated on the stones.
  • Steam water is not clean.

WARRANTY

Pursuant to consumer protection legislation Narvi Black sauna heaters’ warranty period is two years. The warranty covers normal family use provided use, installation and maintenance meet the requirements stipulated in the instructions.

The warranty period starts form the moment that the goods are delivered to the end user. The supplier is not liable in any way for the defects within the framework of the warranty or other defects that appear later than two (2) years after the delivery of the goods to the client. The supplier may decide to either repair the defective goods or replace the defective goods at its own direction. The warranty does not cover possible transport, unloading or installation costs or other similar costs. A receipt from the company selling the product serves as proof of warranty.

The client must check the goods immediately after delivery. The client must submit a written notice of claims to the supplier within two (2) weeks of discovering the defect or the moment when the defect should have been discovered. Use only accessories approved by the manufac-turer with this product. Failure to comply with the manual or fire safety regulations can result in a fire or damage to the sauna heater. More detailed information about the fire safety regulations.

can be obtained from the regional branch of the rescue board, for instance. The product shall be carefully inspected. Improper use of the product is for instance wrong adjustment of the draft, too big quantity of firewood burnt in the firebox, too long heating time, wrong arrangement of stones (too much or too tight) and use of salty water ( for instance sea water). The warranty does not cover damages caused by improper use of the sauna heater.

CE

CE

Narvi Oy 12
EN 15821:2010

Multi-firing sauna stoves fired by natural wood logs for space heating in residential buildings

Narvi Black 20 / Narvi Kaamos 20

Fire safety (initiation, risk to adjacent elements)| Pass
– including declared safety                                            Back
distances to combustible                                               Side
materials: Ceiling| 200 mm

300 mm

1270 mm

Emission of combustible products| Pass
Surface temperature| Pass
Release of dangerous substances| NPD
Cleanability| Pass
Flue gas temperature )| 426 °C
Mechanical resistance| Pass
Thermal output and Energy efficiency, as:
– carbon monoxide emission at 13 % O2| Pass (0,6 %)
– total efficiency| Pass (68 %)
– flue draught
)| 12 Pa
– thermal output

(i.e. nominal space heating output)

| 21 kW
– refuelling loads| 9.3 kg
Durability| Pass

*) Stove door closed

Contact

Narvi Oy

  • Yrittäjäntie 1 27230 Lappi, Finland
  • Tel. +358 207 416 740
  • www.narvi.fi

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NARVI User Manuals