PCE Instruments PCE-4XX-EKIT Outdoor Noise Meter Kit User Manual

June 12, 2024
PCE Instruments

PCE Instruments - logo

User Manual
Outdoor Noise Meter Kit PCE-4XX-EKIT

User manuals in various languages

PCE Instruments PCE 4XX EKIT Outdoor Noise Meter Kit -
qr

www.pce-instruments.com

last change: 4 July 2022
v1.0
© PCE Instruments

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.
  • Remove the batteries when the meter is not used for more than 60 days.
  • Turn off the meter when not in use.

We do not assume liability for printing errors or any other mistakes in this manual.
We expressly point to our general guarantee terms which can be found in our general terms of business.

Introduction

The kit for outdoor noise measurement PCE-4xx-EKIT is combinable with the noise meters PCE428, 430 and PCE-432. This outdoor kit makes it possible to measure outdoor noise with an SPL level meter over a longer period of time.
The environmental noise monitoring system comes in a a waterproof Peli carrying case with rollers. A charger and two additional lead gel batteries are installed in this case, which allows operation for up to 10 days. During the outdoor noise measurement, the case can remain closed. Due to the external connections for the microphone and the power supply, all electronic components are protected from water.

Delivery contents

1 x Outdoor Sound Monitor Kit PCE-4xx-EKIT
1 x Waterproof PELI transport case
1 x Wind and rain protection for microphone of the PCE-4xx series
1 x Charger for internal batteries
2 x 12 V lead gel batteries
1 x Tripod
1 x 2 m / 6ft 6″ microphone cable
1 x Connection cable for power supply 110 V / 230 V (optional Schuko or US connection)

Specifications

Carrying case PELI 1510 with rollers with grid foam
Protection IP65
Connections on the suitcase Microphone: TNC

12 V charging voltage: XLR
110 V / 230 V charging voltage: PowerCon TRU
Charger| Victron Blue Smart 12 V / 4 A IP65
Internal batteries| 2 x 12 V / 12 Ah lead gel
Battery running time| min. 10 days
Power supply| With charger EU Version: 180 … 265 V AC With charger US Version: 100 … 130 V AC Battery operation: 2 x 12 V / 12 Ah
Cable length| Microphone cable: 2 m / 6 ft 6″ with TNC connector Power supply: 2 m / 6 ft 6″ with PowerCon TRU
Dimensions| 56 x 35 x 23 cm / 2.2 x 1.3 x 0.9″
Weight| about 14 kg / 30 lb 13 oz with batteries about 8 kg / 17 lb 10 oz without batteries

Device description

PCE Instruments PCE 4XX EKIT Outdoor Noise Meter Kit - Device description
1

PCE Instruments PCE 4XX EKIT Outdoor Noise Meter Kit - Device description
2

Installing the measuring system

First unfold the tripod. Then guide the measurement signal cable through the microphone holder.
Now connect the microphone to the measurement signal cable and screw the microphone onto its holder. Then screw the microphone holder onto the tripod.
Use the measurement signal input to connect the measurement signal cable to the measuring case. Finally connect the measuring cable and the power supply cable to your sound level meter in the case.

Note: Always ensure vertical position of the microphone. Otherwise, damage through weathering may occur.

Recharging the batteries

There are two methods to charge the batteries.

First method
If you wish to charge the batteries with the charger directly installed in the case, connect the charger to the voltage supply and to the battery supply within the case. Connect the included supply cable outside the measuring case.

Second method
When the temperature within the measuring case could possibly exceed 50 °C, it is recommended to use the charging method with the charger outside the case to avoid overheating which can cause the charger to turn off automatically.
Connect the charger to the charger port outside the measuring case. Now connect the included supply cable to the charger directly.
The different shapes of the plugs do not allow incorrect connection of the charger.

Contact

If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste.
They must be given to collection points designed for that purpose.
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law.
For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
If you have any questions, please contact PCE Instruments.

www.pce-instruments.com

PCE Instruments contact information

United Kingdom
PCE Instruments UK Ltd
Unit 11 Southpoint Business Park
Ensign Way, Southampton
Hampshire
United Kingdom, SO31 4RF
Tel: +44 (0) 2380 98703 0
Fax: +44 (0) 2380 98703 9
info@pce-instruments.co.uk
www.pce-instruments.com/english| United States of America
PCE Americas Inc.
1201 Jupiter Park Drive, Suite 8
Jupiter / Palm Beach
33458 FL
USA
Tel: +1 561-320-9162
Fax: +1 561-320-9176
info@pce-americas.com
www.pce-instruments.com/us
---|---

© PCE Instruments

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PCE Instruments User Manuals

Related Manuals