PCE Instruments PCE-PP Series Parcel Scales User Manual

June 12, 2024
PCE Instruments

PCE Instruments PCE-PP Series Parcel Scales

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.

We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business. If you have any questions please contact PCE Instruments. The contact details can be found at the end of this manual.

Specifications

PCE-PP 20

Weighing range| 0 … 20 kg / 0 … 44 lb
Resolution| 1 g / 0.03 oz
Accuracy| ±0.1 % of weighing range
|
PCE-PP 50
Weighing range| 0 … 50 kg / 0 … 110 lb
Resolution| 1 g / 0.03 oz
Accuracy| ±0.1 % of weighing range
Further specifications
Units| lb / oz, kg / g, kg, g, lb, oz
Overrange indication| “O-Ld”
Low battery voltage indicator| “LO”
Automatic power off| after 5 minutes of inactivity
Power supply battery| 3 x 1.5 V AAA battery
Power supply mains adaptor| primary: 100 … 240 V AC / 50, 60 Hz

secondary: 6 V DC, 1 A

Environmental conditions| 5 … 35 °C, <90 % RH, non-condensing
Weighing platform dimensions| 198 x 180 x 44 / (120 (unfolded)) mm /

7.8 x 7.0 x 1.7 / (4.7 (unfolded)) “

Display dimensions| 92 x 68 x 30 mm / 3.6 x 2.6 x 1.1″
Display cable| spiral cable with a length of 280 mm / 43″
Weight| 810 g / 28.5 oz

Delivery scope

  • 1 x parcel scales PCE-PP Series
  • 3 x 1.5 V AAA battery
  • 1 x mains adaptor
  • 1 x user manual

Device description

No. Description
1 Fold-out wall
2 Weighing surface
3 Display unit
4 Compartment for spiral cable
5 Battery compartment
6 Bracket for display unit
7 Mains connection

Key assignment

Switching the scales on and off

  • To switch on the scales, briefly press the on/off key once. The measurement starts immediately.
  • To switch off the scales, press the key again.

Note: If you do not use the scales within 5 minutes, they switch off automatically. Note that the balance is zeroed when it is switched on. Zeroing does not increase the weighing range.

Taring

To tare the applied weight, press and release the tare key once.
Note: Taring does not increase the weighing range.

Changing the unit

To select the unit, press the unit key repeatedly until you see your desired unit displayed. You can choose lb / oz, kg / g, kg, g, lb or oz.

Piece counting function
First place the reference weight on the weighing platform. To be able to use the piece counting function, now press and hold the piece counting key. With the unit key, you can now select how many pieces are on the scales. You can choose 25, 50, 75 or 100 pieces. Press the piece counting key again to use the piece counting function. To exit the piece counting function, press the unit key. You can repeat the piece count measurement with the same reference at any time by pressing and releasing the piece counting key once. If you want to teach in a new reference weight, start again with this paragraph and repeat the procedure.

Measured value
After the displayed reading has stabilised, the “hold” indicator flashes six times. As soon as “hold” stops flashing, the reading is held for another 6 seconds if the weight changes by more than 5 g.
Note: This function cannot be disabled.

Calibration

To perform a calibration, press and hold the unit key while the scales are switched on until the scales’ weighing range is briefly displayed once. You can then select the calibration weight. To do this, press the tare key. You can choose 5,000 g or 10,000 g. Then press the unit key. “CAL” briefly appears on the display. The set weight is then displayed flashing. Now place the set weight on the weighing cell. After a few seconds, “PASS” is shown on the display if the calibration was successful.

Note: If you wish to cancel the calibration or if an error has occurred, you can cancel the calibration at any time by switching off the scales.

Disposal

  • For the disposal of batteries in the EU, the 2006/66/EC directive of the European.
  • Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose.
  • In order to comply with the EU directive 2012/19/EU we take our devices back. We either reuse them or give them to a recycling company which disposes of the devices in line with law.
  • For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations.
  • If you have any questions, please contact PCE Instruments.

www.pce-instruments.com

QR SCAN

User manuals in various languages  can be found by using our product search on: www.pce-instruments.com

Contact
If you have any questions, suggestions or technical problems, please do not hesitate to contact us. You will find the relevant contact information at the end of this user manual.

Germany
PCE Deutschland GmbH

United Kingdom
PCE Instruments UK Ltd

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PCE Instruments User Manuals

Related Manuals