PCE Instruments PCE-VE 250 Industrial Borescope User Manual

June 12, 2024
PCE Instruments

PCE-Instruments-logo

PCE Instruments PCE-VE 250 Industrial Borescope

PCE-Instruments-PCE-VE-250-Industrial-Borescope-
product

Product Information

The PCE-VE 250 Industrial Borescope is a versatile device designed for industrial inspections. It features a 3.5-inch TFT LCD display and offers video and image functions with resolutions of 640 x 480 pixels. The device is equipped with a freeze function, allowing you to capture still images. It also has a 4-fold digital zoom for detailed inspections.

The borescope comes with a micro SD card slot (4 GB capacity, not included) for storing your videos and images. It supports multiple menu languages including German, English, Spanish, French, Russian, Japanese, simplified Chinese, and traditional Chinese. The device is equipped with various interfaces such as Micro USB 2.0, TV output, and the micro SD card slot.

The main unit is powered by a Li-ion battery with a capacity of 2600 mAh, providing up to 4 hours of continuous operation. It has a splashproof design, ensuring durability in various working conditions. The endoscope cable has a camera head diameter of 8.5 mm and a cable diameter of 4.5 mm. The cable length is approximately 90 cm. The camera resolution is 720 x 576 pixels, and it features adjustable intensity with 6 white LEDs for illumination. The borescope offers a wide field of view and depth for comprehensive inspections.

Product Usage Instructions

  1. Before using the device, carefully read the user manual.
  2. Insert a micro SD card (4 GB) into the micro SD card slot for storage.
  3. Assemble or disassemble the display according to the instructions provided.
  4. Charge the device before use using the provided charging method.
  5. Once charged, turn on the borescope by following the power-on instructions in the user manual.
  6. Use the menu buttons to navigate and select the desired settings and options.
  7. To capture videos, use the video function and select the desired resolution.
  8. To capture still images, use the image function and select the desired resolution.
  9. Adjust the camera lighting intensity as needed for optimal visibility.
  10. Utilize the freeze function to capture still images during inspections.
  11. Use the zoom function for detailed inspections by selecting the desired zoom level.
  12. After use, properly store the device and accessories in a safe and dry place.

For troubleshooting or further assistance, refer to the troubleshooting section in the user manual. For any inquiries or support, contact PCE Instruments using the provided contact information. When disposing of the device, follow the proper disposal guidelines to protect the environment.

Safety notes

Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. Damage or injuries caused by non- observance of the manual are excluded from our liability and not covered by our warranty.

  • The device must only be used as described in this instruction manual. If used otherwise, this can cause dangerous situations for the user and damage to the meter.
  • The instrument may only be used if the environmental conditions (temperature, relative humidity, …) are within the ranges stated in the technical specifications. Do not expose the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
  • Do not expose the device to shocks or strong vibrations.
  • The case should only be opened by qualified PCE Instruments personnel.
  • Never use the instrument when your hands are wet.
  • You must not make any technical changes to the device.
  • The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, no abrasives or solvents.
  • The device must only be used with accessories from PCE Instruments or equivalent.
  • Before each use, inspect the case for visible damage. If any damage is visible, do not use the device.
  • Do not use the instrument in explosive atmospheres.
  • The measurement range as stated in the specifications must not be exceeded under any circumstances.
  • Non-observance of the safety notes can cause damage to the device and injuries to the user.
  • The borescope has been developed for industrial use and must not be used for medical purposes.
  • Never target persons or animals with the device.
  • Only use the device for the intended purpose.

We do not assume liability for printing errors or any other mistakes in this manual. We expressly point to our general guarantee terms which can be found in our general terms of business.

Specifications

Technical specifications

Main unit

Display| 3.5″ TFT LCD
Resolution video function| AVI (640 x 480)
Resolution image function| JPEG (640 x 480)
Image rotation| 360° rotation und mirror function
Freeze function| Yes
Zoom| 4-fold, digital
Storage medium| Micro SD card (4 GB) (not included)
Menu languages| German English Spanish French Russian Japanese

simplified Chinese traditional Chinese

Interfaces| Micro USB 2.0, TV output, Micro SD card slot
TV output| PAL
Power supply| Li-ion battery (2600-mAh)
Typical battery life per battery charge| 4 hours in continuous operation
Protection class| Splashproof
Endoscope cable
Camera head diameter| 8.5 mm / 0.33 in
Cable diameter| 4.5 mm / 0.18 in
Cable length| ca. 90 cm / 2ft 11 in
Camera resolution| 720 x 576 Pixel
Camera lighting| 6 white LEDs (adjustable intensity)
Field of view / angle of view| 60°
Field of view depth| 30 … 60 mm / 1.18…. 2.36 in
Push cable| semi-flexible
Environmental conditions of digital endoscope PCE-VE 250
Operating temperature probe| In air: -10 … 50°C / 14 … 122°F

In water: 5 … 50°C / 41 … 122°F

Operating temperature main unit| In air: -10 … 50°C / 14 … 122°F
Relative humidity probe and main unit| 15 … 90%
Liquid resistance probe and main unit| Machine oil, light oil or saline solution 5%
Probe| Water, oil and dust, to protection class IP67
Main unit| Splash-proof (with closed battery compartment) not usable underwater

Delivery contents

  • 1 x Industrial Borescope PCE-VE 250
  • 1 x Attachable TFT LCD
  • 1 x AV output cable
  • 1 x USB cable
  • 1 x Car charging adapter
  • 1 x Liquid container
  • 1 x Carrying case
  • 1 x Quick shut-off valve
  • 1 x User manual

System description

Device

PCE-Instruments-PCE-VE-250-Industrial-Borescope-fig-2

  1. Display unit
  2. Borescope
  3. Camera cable
  4. Liquid container

Display

PCE-Instruments-PCE-VE-250-Industrial-Borescope-fig-3

  1. On/off key
  2. Micro SD card slot
  3. Micro USB 2.0
  4. TV output
  5. Up/zoom key
  6. Settings key
  7. Image key
  8. Video/OK key
  9. Down/rotation key
  10. Image memory key
  11. LED key
  12. Display lock

Handheld device

  1. Pipe connection
  2. Cleaning outlet
  3. Shut-off valve
  4. Cleaning button
  5. Liquid container connection
  6. Compressed air connection

Camera and cleaning head

  1. Borescope head
  2. Cleaning nozzle
  3. Camera

Getting started

Insert micro SD card

  • Before using the device, insert the micro SD card (not included) into the card slot.

Assembly/disassembly of the display

  • Slide the display down onto the handheld device until it locks in place.
  • To disassemble the display, slide the lock at the rear side of the display outwards and pull up the display to remove it.

Charging

  • The device can be charged via the USB interface, using a micro USB charger or the included car charging adapter.

Operation

On/off

  • Short-press the on/off key to turn the meter on or off.

Taking a picture

  • Press the image key to save the currently displayed image to the SD card. After saving the image, the meter will automatically return to view mode.

Recording settings

  • With the LED key , you can set the brightness at the camera head in 4 levels: off, level 1, level 2 and level 3. The LED icon in the lower right-hand part of the display shows the brightness you have set.
  • You can set the zoom in 3 levels with the up/zoom key . The current zoom is shown with a magnifying glass at the lower edge of the display.
  • To rotate the displayed image, press the down/rotation key .

Video recording

Press the video/OK key to start recording a video. A video icon in the display shows that a video is being recorded. Press the key again to stop recording. The video icon will disappear from the display. The video will automatically be saved to the SD card when recording is finished.

Viewing the saved data

Press the image memory key to view the saved images and videos. You can navigate through the records with the arrow keys . The files are sorted by date and type.

Cleaning function

PCE-Instruments-PCE-VE-250-Industrial-Borescope-fig-13

  • For cleaning, you can either use compressed air only or compressed air and water and/or a cleaning agent. However, compressed air is needed for cleaning with a liquid as the compressed air moves the liquid out of the nozzle. The liquid container must be placed onto the tube and fixed with the union nut.PCE-Instruments-PCE-VE-250-Industrial-Borescope-fig-14
  • Tou se the cleaning function, place the camera cable where required and push the cleaning button (4) of the handheld unit. If you wish to clean with liquid, the shut-off valve (3) must be opened.

Settings

  • To enter the settings, press the settings key and select language selection, time setting, automatic shutdown setting or memory card format with the arrow up/down keys.

Language

  • Select ”language selection“ from the menu and press the video/OK key to enter language selection mode. Use the navigation keys (▲and ▼) to select the desired language and confirm your selection with the video/OK key.

Date/time

  • Select “time setting“ from the menu and press the video/OK key. Use the navigation keys (▲and ▼) to set the desired value.
  • With the image memory key , you can navigate through the parameters.

Energy saving

  • By selecting “shutdown setting“, you can set the time after which the device will turn off automatically. Set the desired time by using the navigation keys (▲and ▼) and confirm your selection with the video/OK key.

Formating the memory card

  • In the menu item “memory card format“, you can set the inserted SD card.
  • Note: When you format the SD card, all saved files will be deleted from the SD card irrevocably!

Operating conditions

Operating conditions of the industrial borescope PCE-VE 250


Operating temperature

| Probe| In the air: -10 … +50 °C

In water: +5 … +50 °C

Main unit| In the air: -10 … +50 °C
Relative humidity| Probe and main unit| 15 … 90 %
Liquid resistance| Probe and main unit| Machine oil, light oil or saline solution 5 %




Ingress protection

| ****

Probe

| Water, oil and dust, IP67 protection


Main unit

| Splash-proof (when battery compartment is closed), not submersible

Troubleshooting

Problem Reason Solution

The borescope does not power on

| Battery flat| ****

Charge the meter by using the USB cable

No records can be saved| No memory card

inserted

| Insert an SD card
No liquid comes out of the nozzle| No or insufficient compressed air| Connect compressed air and ensure 6-8 bar connection pressure

Contact

  • If you have any questions, suggestions or technical problems, please do not hesitate to contact us.
  • You will find the relevant contact information at the end of this user manual.

Disposal

For the disposal of batteries in the EU, the 2006/66/EC directive of the European Parliament applies. Due to the contained pollutants, batteries must not be disposed of as household waste. They must be given to collection points designed for that purpose. In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. For countries outside the EU, batteries and devices should be disposed of in accordance with your local waste regulations. If you have any questions, please contact PCE Instruments.

Contact Information

Germany

United Kingdom

The Netherlands

United States of America

Scan

User manuals in various languages product search on: www.pce- instruments.com

© PCE Instruments

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PCE Instruments User Manuals