HYCO W79 Series Product 2D Ring Scanner User Manual

June 12, 2024
hyco

HYCO W79 Series Product 2D Ring Scanner

Product Information

The W79 Series Product 2D Ring Scanner is a wearable scanner designed to be worn on the index finger of either the left or righthand. It features a ring body that can be triggered for scanning by touching either side of the ring with the thumb finger. The package includes the ring scanner, a charging cradle, and a Bluetooth receiver.

Charging

To charge the ring scanner, connect the charging cradle to a power source. Click the ring scanner into the bottom of the cradle with the scan window facing upward. Ensure that the power contacts of both the ring and cradle are touching. The red light on the cradle indicates that it is charging. When the green light turns on, it means that the charging is complete.
Warning: Do not look directly into the scan window when scanning to avoid potential harm to the eyes. To remove the ring scanner from the charging cradle, gently hold the middle part of the scanner and pull it upward from the cradle.
Ring Scanner Modes
The default factory setting for the ring scanner is SPP mode, which allows for charging cradle connection and program docking. Depending on the device it is connected to (IOS, Android, or Windows), scan the respective code to read barcodes.
Bluetooth Connection
Connect with PC: Connect the cradle to a PC using a USB cable. The green light indicates a normal connection. After 15 seconds, scan the Bluetooth connection barcode with the ring scanner. A blue light will indicate a successful connection.
Connect with Android smartphone/tablet: Find the Bluetooth connection barcode on the side of the cradle. Scan it with the ring scanner and change the Bluetooth name to the serial number. Then, open the Bluetooth settings on the Android device, find the Bluetooth serial number in the list, and connect. The green light indicates a successful connection.

Components

  • Ring Scanner: Used for reading barcodes/2D codes and as a Bluetooth slave.
  • Ring Cradle: Functions as a charging cradle and Bluetooth receiver.
  • Charging Adapter: Connect the adapter to power using a USB cable.
  • USB Cable : Connects the charger to a USB port or charging adapter.
  • Ring Strap (Swappable): Includes 10 pieces in different sizes.
  • Certificate: Factory certification.
  • User Manual: Provides device description and usage instructions.

Specifications

  • Model: W79
  • Scanner Resolution: HYCO CMOS-Sensor Scanner with 1280×800 pixels
  • Code Reading: Barcodes/2D codes
  • Scanning Distance: Long, general, or macro type
  • Weight: 20g (without strap)
  • Dimensions (WDH): 38.6mm29.0mm22.1mm
  • Ring Straps: 10 pcs in different sizes
  • Bluetooth: BT4.2, BLE
  • LED Indicator: RGB LED (programmable)
  • Vibration Indicator: Supported
  • Battery: [email protected]
  • Charging Cradle: With USB dongle and Bluetooth adapter
  • Battery Life: 8 hours (when fully charged with 15-20cm depth of field, and scanning once every 5 seconds)
  • Scanning Trigger: Touch-to-scan
  • IP Level: IP66
  • Drop Test: 3 meters
  • Operating Temperature: -10 to 50 degrees Celsius (14 to 122 degrees Fahrenheit)

Design

Ring Scanner

  • Wearing: wear on index finger on left or right hand
  • Scanning: touch either side of ring body with thumb finger to trigger the scanning

Ring scanner charging cradle(Bluetooth Receiver) Charging

  1. Charging Ring Scanner
    Charging Illustration 1 Charging Illustration 2

    • Connect the Ring scanner charging cradle to power, and click the ring scanner into the bottom of the cradle with the scan window upward. Please note the power contacts of the ring and cradle must be touched.
    • The red light indicates it is in charging, when the green light turns on, it’s finished charging.
    • Warning: don’t look straightly into the scan window when scanning in case of harm to your eyes.
  2. Take the Ring Scanner out of the Ring scanner charging cradle Hold the middle of the ring scanner gently and pull out upward from the cradle

Ring Scanner Modes

  1. SPP Mode (default factory settings) Charging cradle connection and program docking mode
    To connect with PC via USB cradle, scan COMMON code, and scan barcode is available. (Random terminal system is acceptable with the cradle)In this protocol transmission mode, if you need different system programs docking, please get the relevant development SDK at the official website or contact the relevant agent technical support.

  2. HID Mode
    Use the terminal device directly. Output barcodes in HID keyboard mode searched by default Bluetooth. According to the actual system, scan the barcode corresponding to the system and connect.

If the device is connected to IOS smartphone/tablet, scan the IOS code to read the barcodes.

If the device is connected to an ANDROID smart phone/tablet, scan the ANDROID code to read the barcodes.

If the device is connected to WINDOWS smart phone/tablet, scan the WINDOWS code to read the barcodes.

Bluetooth connection

Connect with PC: Connect the cradle with the PC with USB, and the green light means normalconnection. After 15 seconds, scan the Bluetooth connection barcode with the ring scanner, and a blue light indicates successful connection.

Connect with Android smart phone/tablet: First, find the Bluetooth connection barcode on the side of the cradle, scan it with the ring scanner, and change the Bluetooth name to the serial number so that the device can be found; Then open ‘Bluetooth Search’ at the setting menu, find the Bluetooth serial number in the list and connect. Green light indicates successful connection.

Components

Specifications

Model W79
Scanner HYCO CMOS-Sensor Scanner
Resolution 1280×800 pixels
Code Reading Barcodes/2D codes
Scanning Distance Long, general or macro type
Weight 20g (without strap)
Dimensions (WDH) 38.6mm29.0mm22.1mm
Ring Straps 10 pcs in different sizes
Bluetooth BT4.2, BLE
LED Indicator RGB LED (programmable)
Vibration Indicator Supported
Battery [email protected]
Charging Cradle With USB dongle and Bluetooth adapter
Battery Life 8 hours (when fully charged with 15-20cm depth of field, and

scanning once every 5 seconds)
Scanning Trigger| Touch-to-scan
IP Level| IP66
Drop Test| 3 meters
Operating Temperature| -10℃ to 50℃ (14℉ to 122℉)
Humidity| 0%-95%RH (noncondensing)

Note: For Ring Scanner and Ring scanner charging cradle, operating temperature is -10°C to 50°C

  • The technical specifications of this product are subject to change without notice.

Functions

  1. Scanning
    Wear on left or right index finger, touch left or right side of ring and aim at the barcode, the ring light turns green, it starts to scan.

  2. Ring Straps
    Firstly, straightly pull out ring strap from the slot, then choose another ring strap and push it to the top of slot.

  3. Ring Indicator

    • The green light indicates successful scanning.
    • The red light flashing indicates low battery.
    • The green light keeping on for 1 second indicates successful Bluetooth connection.
    • The blue light keeping on for 1 second indicates Bluetooth disconnection.
    • The red, green and blue light flashing indicates restarting.
  4. Bluetooth can’t connect
    Normally, if the Bluetooth light doesn’t turn on, user can scan the barcode “Reset Bluetooth Name”, wait for 10 seconds, and reconnect Scan the barcode “Restore factory settings”, the ring will disconnect Bluetooth connection with terminal devices, and all the settings will change to factory default.

  5. Charging cradle light indicator
    The blue light indicates successful Bluetooth connection between ring scanner and cradle.
    The red light off while the green light on in charging indicates fully charged.

  6. Wake up ring in charging
    The ring doesn’t work when in charging, while it could be waked up by touching either side of ring three times.

  7. Laser calibration
    If laser length changes longer or shorter, please stop scanning, touch ring for 4 seconds once and repeat several times to get it right. If it’s still abnormal, please scan the barcode “Automatic calibration. After scan the barcode “Automatic laser calibration”, the ring turns on purple, put it on the table, wait for 15 seconds until the purple light turns off. The ring laser is calibrated right and functions normally.

  8. Code system on/off

    • Basic setting. 4 default code systems on: EAN13, EAN128, CODE128, CODE39; in which CODE128 and CODE39 read at least 2 characters;
    • Extended setting. 9 default code systems on: EAN8, EAN13, EAN128, UPCA, UPCE, CODE128, CODE39,CODE93, ITF25; in which CODE128 reads at least 1 character; ITF25 only reads 14 characters as default.
      If a code system and code length are not included please contact technical support and local distributor.
  9. Touch switches on both sides
    The touch switch on the left and right sides of the ring scanner are both on by default. If you need to turn off one side, please use the following barcodes to turn it on/off.

Service

Warranty: one year for ring scanner, half year for battery and accessories.

Notice

  • The ring window must be kept clean. Improper usage will breach the limited warranty clause.
  • Avoid rough objects scratching the window.
  • Remove stains from window by soft cloth.
  • Do not spray any liquid onto the window.
  • Use cleaning water to clean.

Function barcodes setup
Change function of scanning after scanning the following barcodes.

“Device information” barcode includes device information (e.g. serial number, version number, Bluetooth version information).

Scan function code “Vibration Open” to activate vibration function, Scan function code “Vibration close” to close vibration function.

In HID mode, scan the barcode “Speed up data transmission through ring cradle”, it  can accelerate the data transmission speed between the cradle and computer; scanthe barcode “Slow down data transmission through ring cradle”, it can slow down the data transmission between the cradle and computer

Scan the barcode “Triggered continuous scanning”, ring could keep scanning when user keeps touching the ring.If user wants to change to common scanning, scan the “Manual Trigger Mode” bar code.

“Manual Trigger Mode” is set by default, user needs to touch ring once to scan once.

Automatic Interval Scanning

After scan “Automatic interval scanning” bar code, ring could automatically scan every 0.5 ~ 3 seconds without touching (2 seconds by default)

After scan “Automatic interval scanning-reduce” barcode, it can expedite the scanning speed once by 0.5 second, the fastest scanning speed is scanning once every 0.5 second.

After scan “Automatic interval scanning-increase” barcode, it can slow down the scanning speed once by 0.5 second, the slowest scanning speed is scanning once every 3 seconds.

Scan angle adjustment

According to different barcode length, user needs to change laser length to achieve better scanning effect.

  1. Scan “Laser calibration” barcode to activate the function, the ring light turns white and begins to automatically and intermittently scan.
  2. After scan “Widen” barcode, the laser length becomes long; after scan “short ” barcode, the scan angle becomes short.
    • Note: do not extend or shorten more than 10 times one time.
  3. Scan “Confirm” barcode, the ring light turns yellow and white, the laser length is confirmed.
  4. Scan “Data generation” barcode, the ring light turns yellow and red, and then turns purple for a while. The laser length is set successfully after the purple light turns off.

Common functional barcodes

To meet different needs for customers, there are some functional barcodes used to meet the requirements for different customers.

After scan “Add Enter” barcode, it can automatically move to next line in the text field after each scanning. If user wants to close the function, scan “Delete Enter” barcode. After scan “Add the tab” barcode, it can automatically moveto next line in excel after each scanning. If user wants toclose the function, scan “Delete the tab” barcode.

HYCO Technology

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

hyco User Manuals