NEUTRIK NAC3MX-W-TOP Cable Connector Instruction Manual

June 12, 2024
NEUTRIK

neutrik-logo

NEUTRIK NAC3MX-W-TOP Cable Connector

NEUTRIK-NAC3MX-W-TOP-Cable-Connector-product

Product Information

The powerCON TRUE1 TOP is a connector used for power applications. It is designed for appliances that require both power input and output connections. The connector has various models with different specifications. It meets the approval standards of VDE EN 60320-1, UL 60320-1, and CAN/CSA-C22.2 No. 60320-1. The rating of the connector depends on the cable type and diameter.

Connector Models:

  • APPLIANCE INLET: NAC3MPX-TOP, NAC3MPX-WOT-TOP
  • Power IN
  • APPLIANCE OUTLET: NAC3FPX-TOP, NAC3FPX-WOT-TOP, NAC3FPX-ST-TOP
  • Power OUT
  • Combination Inlet/Outlet: NAC3PX-TOP
  • Power IN/OUT
  • Connector: NAC3FX-W-TOP
  • Plug Connector: NAC3MX-W-TOP

Approval Standards:

  • VDE EN 60320-1
  • UL 60320-1
  • CAN/CSA-C22.2 No. 60320-1

Rating:

Cable Type: H05VV-F3G, H07RN-F3G, SJTOW, SJOOW
Cable O.D.: 1.0 mm2 to 2.5 mm2 (H05VV-F3G), 1.5 mm2 (H07RN-F3G), 3 x 12 AWG (SJTOW, SJOOW)

Product Usage Instructions:

  1. Insert the cable into the bushing and housing. Apply cable pulling lubricant to the cable jacket.
  2. Separate the housing from the bushing while leaving the cable in the bushing.
  3. Place the chuck over the cable.
  4. Prepare the cable as shown in the instructions.
  5. Insert the wires into the terminals and fasten the screw with Torx size T8. Apply a torque value of 0.7 Nm.
  6. Push and turn simultaneously to slide the chuck and insert together into the housing. Align the chuck and insert by positioning the nose into the keyway.
  7. Apply a torque value of 2.0 Nm to secure the connection.
  8. To disassemble, open the twist lock on the bushing. Slide the bushing up the cable and tighten it with the provided tool. Use a wrench size of 13 mm. Ensure the black O-ring is hidden to achieve IP protection.

Safety Information:

  • Do not expose the connection to bending forces or attach loads to the cable.
  • Replace the connector if any parts are broken or excessively worn for safety and certification reasons.

For more details and information about powerCON TRUE1 TOP, visit www.neutrik.com.

APPLICATION INSTRUCTION

Application other equipment

  • The powerCON TRUE1 system is certified as a connector with breaking capacity according IEC 60320, ® ® VDE 0625.
  • It is intended for use as an appliance coupler and interconnection coupler.
  • It serves to supply power to an appliance and from an appliance to other equipment.
  • To be installed by qualified person only.

CONNECTOR ASSIGNMENTNEUTRIK-NAC3MX-W-TOP-Cable-Connector-fig-
\(1\)

powerCON TRUE1 TOP line is full backward compatible with the preceding powerCON TRUE1 productsNEUTRIK-NAC3MX-W-TOP-Cable-Connector-fig-
10

The manufacturer of cord sets and of interconnection cord sets is responsible for the conformity assessment according to the applicable regulatory documents

ASSEMBLY INFORMATION

NEUTRIK-NAC3MX-W-TOP-Cable-Connector-fig-
\(2\)

  • Insert cable into the bushing and housing.
    Note : “Apply cable pulling lubricant to the cable jacket

  • Separate the housing from the bushing (cable remains in the bushing)

  • Place the chuck over the cable.

  • Prepare cable as shown.
    Recommendation:
    Wire Pulling Lubricant – LUB-I/0.95 TM from 3M
    VDE EN 60320-1
    UL 60320-1 CAN/CSA-C22.2 No. 60320-1NEUTRIK-NAC3MX-W-TOP-Cable-
Connector-fig- \(4\)

  • Slide the chuck onto the insert (1) and then both together into housing (2).
    Important : Align the chuck and insert by positioning the nose into the keyway.

  • Slide the bushing up the cable and tighten it with the tool as shown.
    Important : Black O-ring to hide to achieve IP protection (6).NEUTRIK-
NAC3MX-W-TOP-Cable-Connector-fig- \(5\)

(Tool available: Art. No. HTAC)

FOR DISASSEMBLY OPEN TWIST LOCK!

  1. Press with a screwdriver to unlock
  2. Turn to bush 360°.
  3. Repeat steps 1 + 2 until the bushing is unscrewedNEUTRIK-NAC3MX-W-TOP-Cable-Connector-fig- \(6\)

SAFETY INFORMATION

CAUTION
To ensure the protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no free-dangling cable windings etc.).

SAFETY WARNING
For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear.

Draft. Nr.: BDA 542 V4
Update : 2023-06-28
Neutrik AG I LI-9494 Schaan
www.neutrik.com
Data subject to change without prior notice. © 2023 NEUTRIK®. NEUTRIK®, powerCON are registered trademark of Neutrik AG. ALL RIGHTS RESERVED