DELL Technologies S3048-ON EMC PowerSwitch Instruction Manual
- June 12, 2024
- DELL Technologies
Table of Contents
S3048-ON EMC PowerSwitch
Product Information:
The Dell Networking S3048-ON is a platform that runs on the Dell
Networking OS software. It supports various hardware components,
including a chassis with forty-eight 10/100/1000Base-T RJ-45 ports,
four SFP+ optical ports (10 Gbps), a management port, a USB 2.0
port, a serial console port, two AC PSUs, and three fan subsystems.
The supported software includes Dell Networking OS and ONIE.
Supported Hardware:
- S3048-ON chassis
- Forty-eight 10/100/1000Base-T RJ-45 Ports
- Four SFP+ optical ports (10 Gbps)
- Management Port
- USB 2.0 Port
- Serial Console Port
- Two AC PSUs
- Three fan subsystems
Supported Software:
- Dell Networking OS
- ONIE
New Dell Networking OS Version 9.14(2.16) Features:
The Dell Networking OS version 9.14(2.16) introduces no new
features.
Restrictions:
To upgrade the Dell Networking OS from an earlier version to
9.14.2.0 or later, follow these prerequisite steps:
-
Uninstall the older version of the Open Automation (OA)
package. -
Upgrade the Dell Networking OS to 9.14.2.0 or later
version. -
Install the following OA packages from the respective upgraded
version:- SmartScripts
- Puppet
- Open management infrastructure (OMI)
- SNMP MIB
To downgrade the Dell Networking OS from 9.14.2.0 or later to an
earlier version, follow these prerequisite steps:
- Uninstall the OA package of 9.14.2.0 or later version.
- Downgrade the Dell Networking OS to an earlier version.
- Install the respective OA package from an earlier version.
Note: If you downgrade the Dell Networking OS version from
9.14.2.16 to 9.11.0.0 or any older versions, you may encounter a
CDB boot error. To resolve this issue, save the current
configuration and remove the CDB files (confd_cdb.tar.gz.version
and confd_cdb.tar.gz) using the provided commands.
When deploying the system in normal-reload mode in BMP
configuration, use the “ip ssh server enable” command at the
beginning of the startup configuration if the “write memory”
command is used at the end of the configuration.
Please note that REST API does not support AAA authentication,
and certain features are not available in Dell Networking OS
version 9.7(0.0).
Product Usage Instructions:
For detailed instructions on installing, uninstalling, and
upgrading the Dell Networking OS and OA package, please refer to
the respective Dell System Release Notes.
Rev. A00 August 2022
Dell System S3048ON 9.14(2.16) Release
Notes
This document contains information on open and resolved caveats, and
operational information specific to the Dell Networking OS software and the
S3048-ON platform. Current Release Version: 9.14(2.16) Release Date:
2022-08-19 Previous Release Version: 9.14(2.14)
Topics:
· Document Revision History · Supported Hardware · Supported Software · New
Dell Networking OS Version 9.14(2.16) Features · Restrictions · Changes to
Default Behavior and CLI Syntax · Documentation Corrections · Deferred Issues
· Fixed Issues · Known Issues · Upgrading the sub-components · Upgrading ONIE
on the S3048-ON · Installing Dell Networking OS on the S3048-ON using ONIE ·
Upgrading the S3048-ON Dell Networking OS Image using the Dell Networking OS
CLI · Uninstalling Dell Networking OS on the S3048-ON · Installing a Third
Party Operating System · Support Resources
NOTE: This document may contain language that is not consistent with current
guidelines of Dell Technologies. There are plans to update this document over
subsequent releases to revise the language accordingly.
Incorrect behavior or unexpected caveats are listed as the Problem Report (PR)
numbers within the appropriate sections.
For more information on hardware and software features, commands, and
capabilities, see the Dell Networking website at:
https://www.dellemc.com/networking.
Document Revision History
Table 1. Revision History
Date
Description
202208
Initial release.
1
Supported Hardware
The following hardware is supported with this platform: Hardware S3048-ON
chassis Forty-eight 10/100/1000Base-T RJ-45 Ports Four SFP+ optical ports (10
Gbps) Management Port USB 2.0 Port Serial Console Port Two AC PSUs Three fan
subsytems
NOTE: If all the three fan trays are found to be empty or faulty, the system
shuts down after one minute.
Supported Software
The following software is supported with this platform: Software Dell
Networking OS ONIE
Minimum Release Requirement 9.14(2.16) 3.24.1.0-4
NOTE: For information on non-Dell OS versions, refer the Release Notes for the Hardware Platform S3048ON.
New Dell Networking OS Version 9.14(2.16) Features
The following features are integrated into the Dell Networking 9.14.2 branch
through this release: None
Restrictions
Prerequisite steps to upgrade the Dell Networking OS from earlier version to
9.14.2.0 or later: 1. Uninstall the older version of the Open Automation (OA)
package 2. Upgrade the Dell Networking OS to 9.14.2.0 or later version 3.
Install the following OA packages from the respective upgraded version: a.
SmartScripts b. Puppet c. Open management infrastructure (OMI) d. SNMP MIB
Prerequisite steps to downgrade the Dell Networking OS from 9.14.2.0 or later
to the earlier version:
2
1. Uninstall the OA package of 9.14.2.0 or later version 2. Downgrade the
Dell Networking OS to an earlier version 3. Install the respective OA package
from an earlier version
For more information about installing, uninstalling and upgrading the Dell
Networking OS and OA package, see the respective Dell System Release Notes.
If you downgrade the Dell Networking OS version from 9.14.2.16 to 9.11.0.0 or
any older versions, the system displays the following error message even
though there is no functional impact:
CDB boot error: C.cdb file format
Before downgrading, save the current configuration and then remove the CDB
files (confd_cdb.tar.gz.version and confd_cdb.tar.gz). To remove the files,
use the following steps:
DellEMC#write memory DellEMC#delete flash://confd_cdb.tar.gz.version
DellEMC#delete flash://confd_cdb.tar.gz DellEMC#reload
While deploying the system in the normal-reload mode in BMP configuration, use
the ip ssh server enable command at the beginning of the startup configuration
if the write memory command is used at the end of the configuration.
REST API does not support AAA authentication. The following features are not
available in the Dell Networking OS from version 9.7(0.0):
PIM ECMP Static IGMP join (ip igmp static-group) IGMP querier timeout
configuration (ip igmp querier-timeout) IGMP group join limit (ip igmp group
join-limit) Half-Duplex mode is not supported. When FRRP is enabled in a VLT
domain, no flavor of Spanning tree should concurrently be enabled on the nodes
of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a
VLT environment.
Changes to Default Behavior and CLI Syntax
The following behavior and CLI changes are applicable to the S3048ON switch
with Dell Networking OS version 9.14(2.16): None
Documentation Corrections
This section describes the errors identified in the current release of the
Dell Networking OS. The router bgp command allows you to configure only one L3
interface with an IPv4 address. The Configuration guide
does not mention this limitation and will be corrected in the next release of
the guide.
Deferred Issues
Issues that appear in this section were reported in Dell Networking OS version
9.14(2.0) as open, but have since been deferred. Deferred caveats are those
that are found to be invalid, not reproducible, or not scheduled for
resolution.
Deferred issues are reported using the following definitions.
Category
Description
PR# Severity
Problem Report number that identifies the issue.
S1 — Crash: A software crash occurs in the kernel or a running process that
requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable,
which can have a pervasive impact on the system or network, and for which
there is no work-around acceptable to the customer.
3
Category
Synopsis Release Notes Work around
Description
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer. S4 — Minor: A cosmetic issue or an issue in a
minor feature with little or no network impact for which there might be a
work-around.
Synopsis is the title or short description of the issue.
Release Notes description contains more detailed information about the issue.
Work around describes a mechanism for circumventing, avoiding, or recovering
from the issue. It might not be a permanent solution. Issues listed in the
“Closed Caveats” section should not be present, and the work-around is
unnecessary, as the version of code for which this release note is documented
has resolved the caveat.
Deferred S3048ON 9.14(2.0) Software Issues
Issues that appear in this section were reported in Dell Networking OS version
9.14(2.0) as open, but have since been deferred. Deferred caveats are those
that are found to be invalid, not reproducible, or not scheduled for
resolution. The following issues have been deferred in the Dell Networking OS
version 9.14(2.0): None.
Fixed Issues
Fixed issues are reported using the following definitions.
Category
PR# Severity
Description
Problem Report number that identifies the issue.
S1 — Crash: A software crash occurs in the kernel or a running process that
requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable,
which can have a pervasive impact on the system or network, and for which
there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no
network impact for which there might be a work-around.
Synopsis Release Notes Work around
Synopsis is the title or short description of the issue.
Release Notes description contains more detailed information about the issue.
Work around describes a mechanism for circumventing, avoiding, or recovering
from the issue. It might not be a permanent solution. Issues listed in the
“Closed Caveats” section should not be present, and the work-around is
unnecessary, as the version of code for which this release note is documented
has resolved the caveat.
Fixed S3048ON 9.14(2.16) Software Issues
NOTE: Dell Networking OS 9.14(2.16) includes fixes for caveats addressed in
the previous 9.14 releases. Refer to the respective release notes
documentation for the list of caveats fixed in the earlier 9.14 releases. The
following caveats have been fixed in Dell Networking OS version 9.14(2.16):
4
PR# 170307 Severity: Synopsis:
Release Notes:
Workaround:
Sev 3
In certain scenarios, when SSH daemon crashes the switch becomes inaccessible.
In certain scenarios, when SSH daemon crashes the switch becomes inaccessible.
None
Known Issues
Known issues are reported using the following definitions.
Category
PR# Severity
Description
Problem Report number that identifies the issue.
S1 — Crash: A software crash occurs in the kernel or a running process that
requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable,
which can have a pervasive impact on the system or network, and for which
there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or
negatively effects the network for which there exists a work-around that is
acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no
network impact for which there might be a work-around.
Synopsis Release Notes Work around
Synopsis is the title or short description of the issue.
Release Notes description contains more detailed information about the issue.
Work around describes a mechanism for circumventing, avoiding, or recovering
from the issue. It might not be a permanent solution. Issues listed in the
“Closed Caveats” section should not be present, and the work-around is
unnecessary, as the version of code for which this release note is documented
has resolved the caveat.
Known S3048ON 9.14(2.16) Software Issues
The following caveats are open in Dell Networking OS version 9.14(2.16): None.
Upgrading the sub-components
Ensure to upgrade the sub-components in the following order and reload the
switch, where necessary, before proceeding with the next sub-component
upgrade. 1. Upgrade the BIOS or Boot-selector – using the upgrade boot
bootselector-image stack-unit 1 booted
command. 2. Upgrade the GRUB or Bootflash – using the upgrade boot bootflash-
image stack-unit 1 booted command. 3. Upgrade the CPLD – using the upgrade
fpga-image system cpld stack-unit 1 booted command.
5
Upgrade the BIOS or Boot Selector
To upgrade the BIOS or Boot Selector from Dell Networking OS, perform the
following steps: 1. Upgrade the S3048-ON Boot Selector image.
EXEC Privilege
upgrade boot bootselector-image stack-unit [
DellEMC#upgrade boot bootselector-image stack-unit 1 booted
Current Boot information in the system:
================================================================
Card
BootSelector Current Version
New Version
—————————————————————-
Unit1
Boot Selector
3.24.0.0-9
3.24.0.0-11
-
Warning – Upgrading boot selectors is inherently risky and should *
-
only be attempted when necessary. A failure at this upgrade may *
-
cause a board RMA. Proceed with caution !
Proceed upgrade Boot Selector image for stack-unit 1 yes/no: yes
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!00:02:33: %S3048-ON:1 %CHMGR- 2FAN_SPEED_CHANGE: Fan speed changed to 52 % of the full speed !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! Bootselector image upgrade for stack-unit 1 completed successfully. DellEMC#
2. Reload the unit. EXEC Privilege reload
3. Verify the Boot Selector image.
EXEC Privilege show system stack-unit
DellEMC#show system stack-unit 1
— Unit 1 —
Unit Type
: Management Unit
Status
: online
Next Boot
: online
Required Type
: S3048-ON – 52-port GE/TE (SG-ON)
Current Type
: S3048-ON – 52-port GE/TE (SG-ON)
Master priority
: 0
Hardware Rev
: 0.0
Num Ports
: 52
Up Time
: 13 min, 15 sec
Dell EMC Networking OS Version : 9.14(2.16)
Jumbo Capable
: yes
POE Capable
: no
FIPS Mode
: disabled
Boot Flash
: 3.24.2.9
Boot Selector
: 3.24.0.0-11
Memory Size Temperature Voltage Serial Number
: 2127654912 bytes : 30C : ok : NA
6
Part Number Vendor Id Date Code Country Code Piece Part ID PPID Revision Service Tag Expr Svc Code Auto Reboot Burned In MAC No Of MACs
: 0VCY6T
Rev A00
: NA
: NA
: NA
: CN-123456-DELLI-215-8989
: A00
: NA
: NA
: enabled
: 00:e0:ec:25:d9:50
: 3
— Power Supplies —
Unit Bay Status
Type FanStatus FanSpeed(rpm)
—————————————————–
1
1 up
AC
up
8032
1
2 up
AC
up
8096
— Fan Status —
Unit Bay TrayStatus Fan1 Speed
————————————–
1 1
up
up
7200
1 2
up
up
7200
1 3
up
up
7200
Speed in RPM
DellEMC#
Upgrade the GRUB or Boot Flash
To upgrade the GRUB or Boot Flash from Dell Networking OS, perform the
following steps: 1. Upgrade the S3048-ON Boot Flash image.
EXEC Privilege
upgrade boot bootflash-image stack-unit [
DellEMC#upgrade boot bootflash-image stack-unit 1 booted
Current Boot information in the system:
=====================================================================
Card
BootFlash
Current Version
New Version
———————————————————————
Unit1
Boot Flash
3.24.2.3
3.24.2.9
-
Warning – Upgrading boot flash is inherently risky and should only *
-
be attempted when necessary. A failure at this upgrade may cause *
-
a board RMA. Proceed with caution !
Proceed upgrade Boot Flash image for stack-unit 1 yes/no: yes
!!!!! Bootflash image upgrade for stack-unit 1 completed successfully.
Upgrade the CPLD
The S3048-ON system with Dell Networking OS Version 9.14(2.16) requires System
CPLD revision 10 and Module CPLD revision 9.
NOTE: If your CPLD revisions are higher than the ones shown here, DO NOT make
any changes. If you have questions regarding the CPLD revision, contact
technical support..
7
Verify that a CPLD upgrade is required
Use the following command to identify the CPLD version:
DellEMC#show revision
— Stack unit 1 -S3048-ON SYSTEM CPLD
S3048-ON MODULE CPLD
DellEMC#
: 10 : 9
Use the following command to view CPLD version that is associated with the Dell Networking OS image:
DellEMC#show os-version
RELEASE IMAGE INFORMATION :
——————————————————————–
Platform
Version
Size
ReleaseTime
S-Series:SG-ON
9.14(2.16)
65838348
Feb 21 2022 08:37:00
TARGET IMAGE INFORMATION :
——————————————————————–
Type
Version
Target
checksum
runtime
9.14(2.16)
Control Processor
passed
BOOT IMAGE INFORMATION :
——————————————————————–
Type
Version
Target
checksum
boot flash
3.24.2.9
Control Processor
passed
BOOTSEL IMAGE INFORMATION :
——————————————————————–
Type
Version
Target
checksum
boot selector
3.24.0.0-11
Control Processor
passed
FPGA IMAGE INFORMATION :
——————————————————————–
Card
FPGA Name
Version
stack-unit 1
S3048-ON SYSTEM CPLD
10
stack-unit 1
S3048-ON MODULE CPLD
9
DellEMC#
Upgrading the CPLD Image
NOTE: The upgrade fpga-image stack-unit 1 booted command is hidden when using the FPGA Upgrade feature in the CLI. However, it is a supported command and will be accepted when entered as documented.
NOTE: Ensure that the BIOS version is 3.24.0.0-11. You can verify this version using show system stack-unit 1 command.
To upgrade the CPLD image on S3048-ON, follow these steps. 1. Upgrade the CPLD
image.
EXEC Privilege upgrade fpga-image stack-unit
DellEMC#upgrade fpga-image stack-unit 1 booted
Current information for the system:
========================================================================
Card
Device Name
Current Version
New Version
————————————————————————
Unit1
S3048-ON SYSTEM CPLD
9
10
Unit1
S3048-ON MODULE CPLD
7
9
8
-
Warning – Upgrading FPGA is inherently risky and should
-
only be attempted when necessary. A failure at this upgrade may *
-
cause a board RMA. Proceed with caution !
Upgrade image for stack-unit 1 yes/no: yes
FPGA upgrade in progress!!! Please do NOT power off the unit!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Upgrade result : ================ Unit 1 FPGA upgrade successful. Power cycle
the Unit 1 to complete the upgrade.
DellEMC#00:04:11: %S3048-ON:1 %DOWNLOAD-6-FPGA_UPGRADE: stack-unit 1 fpga
upgrade success.
DellEMC#
Need to power cycle the unit to complete the FPGA upgrade.
2. Power cycle the system physically. Switch off the system by unplugging the
power chords from the REAR PSUs and wait until the PSU FANREAR STATUS LED is
completely OFF. NOTE: Do not switch on the system with PSUREAR LED glowing
AMBER.
You can alternatively power cycle the switch using the power-cycle stack-unit
<1-6> command as follows:
DellEMC#power-cycle stack-unit 1 Proceed with power-cycle? Confirm
3. The CPLD version can be verified using show revision command output :
EXEC Privilege show revision
DellEMC#show revision
— Stack unit 1 -S3048-ON SYSTEM CPLD
S3048-ON MODULE CPLD
DellEMC#
: 10 : 9
NOTE: Do not power off the system while FPGA upgrade is in progress. For any queries, contact technical support.
Upgrading ONIE on the S3048-ON
To upgrade the ONIE package you have installed, use one of the following two
processes: zero touch (dynamic) update or manual update. 1. Zero touch
(dynamic): Copy the update ONIE installer and the DIAG installer for your
system to the TFTP/
HTTP server.Configure the DHCP options using the ONIE specifications shown at
the following link: http:// opencomputeproject.github.io/onie/docs/design-
spec/updater.html S3048-ON image>>>> onie-updater-x86_64-s3000_c2338-r0
2. Manual: Copy the image onto the TFTP/HTTP servers and boot ONIE. Update
the ONIE using the onie-self-update command, then download and run an ONIE
updater image. The supported URL types are: HTTP, FTP, TFTP, and FILE.
S3048-ON image>>>> onie-updater-x86_64-s3000_c2338-r0
3. UPGRADING ONIE ON AN EXISTING S3048ON SYSTEM.
9
The following example uses HTTP to upgrade ONIE.
ONIE:/ # onie-self-update tftp://10.16.127.35/onie-updater-x86_64-s3000_c23
38-r0
Stopping: discover… done.
Info: Fetching tftp://10.16.127.35/onie-updater-x86_64-s3000_c2338-r0 …
onie-updater-x86_64- 100% |***| 9021k 0:00:00 ETA
ONIE: Executing installer: tftp://10.16.127.35/onie-updater- x86_64-s3000_c2338-r0
Verifying image checksum … OK.
Preparing image archive … OK.
ONIE: Version
: 3.24.1.0-4
ONIE: Architecture : x86_64
ONIE: Machine
: s3000_c2338
ONIE: Machine Rev : 0
ONIE: Config Version: 1
Installing ONIE on: /dev/sda
Rebooting…
ONIE:/ # umount: can’t remount rootfs read-only
The system is going down NOW!
Sent SIGTERM to all processes
Sent SIGKILL tosd 0:0:0:0: [sda] Synchronizing SCSI cache
Restarting system.
machine restart
4. Upgrade the DIAG installer package.
ONIE:/ # onie-nos-install tftp://10.16.127.35/INSTALLER-DND-SG-2.0.0.5.bin
Stopping: discover… done. Info: Fetching tftp://10.16.127.35/INSTALLER-DND-
SG-2.0.0.5.bin … INSTALLER-DND-SG-2.0 100% |***|
27956k 0:00:00 ETA ONIE: Executing installer: tftp://10.16.127.35/INSTALLER-
DND-SG-2.0.0.5.bin Verifying image checksum … OK. Preparing image archive from
/installer … Done. Mounting /dev/sda3…Done. Copying Images …Done. Installing
Menu Entry …Done. ONIE:/ # umount: can’t remount rootfs read-only The system
is going down NOW! Sent SIGTERM to all processes Sent SIGKILL tosd 0:0:0:0:
[sda] Synchronizing SCSI cache Restarting system. machine restart
5. Upgrade the BIOS image using the BIOS image and Flashrom utility included
with the diagnostic package.
ONIE:/ # ONIE:/ # tftp -g -r s3000-bios-3.24.0.0-11.bin 10.16.127.35 s3000-bios-3.24.0.0-11. 100% |***| ONIE:/ # ONIE:/
flashrom -E -p internal Erasing and writing flash chip… Erase/write done.
ONIE:/ # ONIE:/ # ONIE:/ # flashrom -w s3000-bios-3.24.0.0-11.bin -p internal Erasing and writing flash chip… Erase/write done. Verifying flash… VERIFIED. ONIE:/ # ONIE:/ # ONIE:/ # reboot ONIE:/ # umount: can’t remount rootfs read- only The system is going down NOW! Sent SIGTERM to all processes Sent SIGKILL tosd 0:0:0:0: [sda] Synchronizing SCSI cache Restarting system. machine restart
8192k
0:00:00 ETA
BIOS (Dell EMC Inc) Boot Selector S3000 3.24.0.0-11
(48-port 1G/4-port SFP+ 10G)
10
CPLD JTAG to normal mode… done. Resetting…
Installing Dell Networking OS on the S3048-ON using ONIE
NOTE: The Dell Networking OS installer package, ONIE-FTOS-SG-ON-9.14.2.16.bin,
is required for installing Dell Networking OS on S3048-ON that has only ONIE.
To install the Dell Networking OS version 9.14(2.16) on to the new S3048-ON
device, perform the following steps: 1. Boot the system to the ONIE prompt.The
following ONIE prompt appears: ONIE:/ # 2. Stop the ONIE discovery process
using the following command: ONIE:/ # onie-discovery-stop The following
message appears:
Stopping: discover… done. ONIE:/ # 3. Configure an interface and assign an IP
address to that interface using the following command:
ONIE:/ # ifconfig eth0 ip-address/prefix up 4. Enter the following command to
begin the installation process:
ONIE:/ # onie-nos-install tftp://10.16.127.35/ONIE-FTOS-SG-ON-9.14.2.16.bin
NOTE: After the Dell Networking OS installation is complete, the system automatically reboots.
Following is the installation and boot log of Dell Networking OS:
ONIE:/ #
ONIE:/ #
ONIE:/ # onie-nos-install tftp://10.16.127.35/ONIE-FTOS-SG-9.14.2.16.bin
Stopping: discover… done.
Info: Fetching tftp://10.16.127.35/ONIE-FTOS-SG-9.14.2.16.bin …
ONIE-FTOS-SG-9.14.2.16 100% |***| 95426k 0:00:00 ETA
ONIE: Executing installer: tftp://10.16.127.35/ONIE-FTOS-SG-
.2.7.bin
Verifying image checksum … OK.
Preparing image archive from /installer … Done.
Verifying Product Platform…
Image File
: ONIE-FTOS-SG-9.14.2.16.bin
Product Name
: S3048-ON
Platform Verified
: OK
Deleting Extra partitions… Done.
Creating New partitions… Done.
Creating Hybrid MBR… Done.
Mouting /dev/sda4,/dev/sda5 and /dev/sda6… Done.
Installing GRUB on /dev/sda4…Done.
Copying Images… Done.
ONIE:/ # umount: can’t remount rootfs read-only
The system is going down NOW!
Sent SIGTERM to all processes
Sent SIGKILL tosd 0:0:0:0: [sda] Synchronizing SCSI cache
Restarting system.
machine restart
BIOS (Dell EMC) Boot Selector S3000 3.24.0.0-11
(48-port 1G/4-port SFP+ 10G)
11
CPLD JTAG to normal mode… done. Resetting…
POST Configuration CPU Signature 406D8 CPU FamilyID=6, Model=4D, SteppingId=8,
Processor=0 Microcode Revision 125 Platform ID: 0x1004183D PMG_CST_CFG_CTL:
0x40006 BBL_CR_CTL3: 0x7E2801FF Misc EN: 0x4000840081 Gen PM Con1: 0x1008
Therm Status: 0x88490000 POST Control=0xEA010303, Status=0xE6009601
BIOS initializations…
CPLD JTAG to normal mode… done.
BIOS initializations…
CPGC Memtest for Channel 0 ……………… PASS ECC enabled: channel 0
MayCCTRL_DUNIT_REG=0x000200F3
POST: RTC Battery OK at last cold boot RTC date Monday 02/21/2022 22:35:26
POST SPD test ………………………………. PASS
POST Lower DRAM Memory test Short memory cell test Perf cnt (curr,fixed):
0x21157AA35,0x31A008980
POST Lower DRAM Memory test …………….. PASS POST Lower DRAM ECC check ……………….
PASS
Dell DxE configurations… Broadcom Preemphasis…
Gen1=0x4, Gen2=0x43 done. NPU CDR… .. done. SM Bus1 PHY…done
DxE POST POST PCI test …………………………. PASS POST NVRAM check ………………………. PASS POST
overall test results ……………………. PASS
Version 2.16.1242. Copyright (C) 2021 American Megatrends, Inc. BIOS Date:
02/21/2022 01:14:04 Ver: 0ACBZ018 Press DEL or F2 to enter setup.
Grub 1.99~rc1 (Dell EMC) Built by root at ubuntu on
Mon_Feb_21_14:42:47_UTC_2022 S3000ON Boot Flash Label 3.24.2.9 NetBoot Label
3.24.2.9
Press Esc to stop autoboot … 0
5. After the installation completes, the system displays the following DELL
prompt: DellEMC#
12
Upgrading the S3048-ON Dell Networking OS Image
using the Dell Networking OS CLI
Bare Metal Provisioning
NOTE: If you are using Bare Metal Provisioning (BMP), see the Bare Metal
Provisioning topic in the Dell Networking OS
Configuration Guide or the Open Automation Guide.
Manual Upgrade Procedure
Follow these steps carefully to upgrade your S3048-ON systems: 1. Dell
Networking recommends that you back up your startup configuration and any
important files and directories to an
external media prior to upgrading the system. NOTE: If you are upgrading from
Dell Networking OS version 9.10.0.1P5 or earlier, you cannot directly upgrade
to
version 9.10.0.1P13 or above. Upgrade to version 9.10.0.1P8 first and then
upgrade to the required version.
2. Upgrade the Dell Networking OS in flash partition A: or B:
EXEC Privilege
upgrade system [flash: | ftp: stack-unit <1-6> | tftp: | scp: | usbflash:] [A:
| B:] DellEMC#upgrade system tftp: a: Address or name of remote host []:
10.16.127.35 Source file name []: FTOS-SG-9.14.2.16.bin 3d17h59m : Discarded 1
pkts. Expected block num : 62. Received block num: 61 3d17h59m : Discarded 1
pkts. Expected block num : 65. Received block num: 64
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!…………….
…………….! 62620397 bytes successfully copied System image upgrade completed
successfully. DellEMC#Feb 21 11:56:43: %STKUNIT1-M:CP %DOWNLOAD-6-UPGRADE:
Upgrade completed successfully DellEMC#
DellEMC#upgrade system tftp: b: Address or name of remote host []:
10.16.127.35 Source file name []: FTOS-SG-9.14.2.16.bin 3d18h2m : Discarded 1
pkts. Expected block num : 51. Received block num: 50 3d18h2m : Discarded 1
pkts. Expected block num : 65. Received block num: 64
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!…………
……………………..! 62620397 bytes successfully copied System image upgrade completed
successfully. DellEMC#Feb 21 12:00:33: %STKUNIT1-M:CP %DOWNLOAD-6-UPGRADE:
Upgrade completed successfully DellEMC#
3. Verify that the Dell Networking OS has been upgraded correctly in the
upgraded flash partition.
EXEC Privilege
show boot system stack-unit [1-6] | all]
DellEMC#show boot system stack-unit all
Current system image information in the system:
=====================================================================
Type
Boot Type
A
B
———————————————————————
stack-unit 1 DOWNLOAD BOOT 9.14(2.16)[boot]
9.14(2.14)
stack-unit 2 is not present.
stack-unit 3 is not present.
stack-unit 4 is not present.
stack-unit 5 is not present.
stack-unit 6 is not present.
DellEMC#
4. Change the Primary Boot Parameter of the S3048-ON to the upgraded partition A: or B:
13
CONFIGURATION boot system stack-unit 1 primary system: [A: | B: | tftp: | ftp:] 5. Save the configuration so that the configuration will be retained after a reload using write memory command. EXEC Privilege write memory
DellEMC#write memory ! Feb 21 18:58:59: %STKUNIT1-M:CP %FILEMGR-5-FILESAVED:
Copied running-config to startup-config in flash by default
DellEMC#
6. Reload the unit.
EXEC Privilege
reload
Command
: reload
Mode
: EXEC PRIVILEGE
DellEMC#reload
Proceed with reload [confirm yes/no]: y
7. Verify the S3048 ON has been upgraded to the Dell Networking OS version 9.14(2.16). EXEC Privilege show version
DellEMC#show version Dell EMC Real Time Operating System Software Dell EMC
Operating System Version: 2.0 Dell EMC Application Software Version:
9.14(2.16) Copyright (c) 1999-2021 by Dell EMC Inc. All Rights Reserved. Build
Time: Mon Feb 21 10:20:04 2022 Build Path: /build/build01/SW/SRC Dell EMC
Networking OS uptime is 3 day(s), 21 hour(s), 3 minute(s)
System image file is “system://A”
System Type: S3048-ON Control Processor: Intel Rangeley with 2 Gbytes
(2127654912 bytes) of memory, core(s) 2.
8G bytes of boot flash memory.
1 52-port GE/TE (SG-ON) 48 GigabitEthernet/IEEE 802.3 interface(s)
4 Ten GigabitEthernet/IEEE 802.3 interface(s) DellEMC#
Uninstalling Dell Networking OS on the S3048-ON
To uninstall the Dell Networking OS version 9.14(2.16) from the S3048-ON
device, perform the following steps: 1. Reboot the system. During the reboot
process, the system displays the following message prompting you to press the
Esc
key in order to stop the auto-boot process:
Version 2.16.1242. Copyright (C) 2021 American Megatrends, Inc. BIOS Date:
02/21/2022 01:14:04 15:25:58 Ver: 0ACBZ018
Press DEL or F2 to enter setup.
Grub 1.99~rc1 (Dell EMC) Built by root at ubuntu on
Mon_Feb_21_14:42:47_UTC_2022 S3000ON Boot Flash Label 3.24.2.9 NetBoot Label
3.24.2.9
14
Press Esc to stop autoboot … 5 2. At this prompt message, press the Esc key. The following menu appears:
+—————————————————————————-+ | Dell EMC Networking OS | Dell EMC-Boot Line Interface | DELL-DIAG | ONIE
+—————————————————————————-+
3. From the menu, choose the ONIE option. NOTE: To choose an option from the
menu, highlight one of the options using the up or down arrow key and press
Enter.
The following menu appears:
+———————————————————————+
| ONIE: Install OS
|
| ONIE: Rescue
|
|*ONIE: Uninstall OS
|
| ONIE: Update ONIE
|
| ONIE: Embed ONIE
|
| ONIE: Diag ONIE
|
| DELL-DIAG
|
+———————————————————————+
4. From this menu, choose the ONIE : Uninstall OSoption.
NOTE: To choose an option from the menu, highlight one of the options using
the up or down arrow key and press
Enter.
The uninstall process begins. Following is the log generated by the system
while Dell Networking OS 9.14.2.16 uninstalls:
ONIE: OS Uninstall Mode … Version : 3.24.1.0-4 Build Date:
2022-02-21T13:53-0700 Info: Mounting kernel filesystems… done. Info: Mounting
LABEL=ONIE-BOOT on /mnt/onie-boot … Info: Using eth0 MAC address:
00:85:13:53:99:10 Info: Using eth1 MAC address: 00:85:13:53:99:11 Info: eth0:
Checking link… up. Info: Trying DHCPv4 on interface: eth0 DHCPv4 on interface:
eth0 failedONIE: Using default IPv4 addr: eth0: 192.168.3.10/255.255.255.0
Info: eth1: Checking link… down. ONIE: eth1: link down. Skipping
configuration. ONIE: Failed to configure eth1 interface Starting: dropbear ssh
daemon… done. Starting: telnetd… done. discover: Uninstall mode detected.
Running uninstaller. Erasing internal mass storage device: /dev/sda3 (300MB)
Percent complete: 100% Erase complete. Deleting partition 3 from /dev/sda
Erasing internal mass storage device: /dev/sda4 (32MB)
Percent complete: 100% Erase complete. Deleting partition 4 from /dev/sda
Erasing internal mass storage device: /dev/sda5 (300MB)
Percent complete: 100% Erase complete. Deleting partition 5 from /dev/sda
Erasing internal mass storage device: /dev/sda6 (300MB)
Percent complete: 100% Erase complete. Deleting partition 6 from /dev/sda
Erasing internal mass storage device: /dev/sda7 (6578MB)
Percent complete: 100% Erase complete.
15
Deleting partition 7 from /dev/sda Installing for i386-pc platform.
Installation finished. No error reported. Uninstall complete. Rebooting…
umount: can’t remount rootfs read-only The system is going down NOW! Sent
SIGTERM to all processes Sent SIGKILL to all processes Requesting system
reboot sd 0:0:0:0: [sda] Synchronizing SCSI cache Restarting system. machine
restart
BIOS (Dell EMC) Boot Selector S3000 3.24.0.0-11
(48-port 1G/4-port SFP+ 10G)
CPLD JTAG to normal mode… done. Resetting…
POST Configuration CPU Signature 406D8 CPU FamilyID=6, Model=4D, SteppingId=8,
Processor=0 Microcode Revision 125 Platform ID: 0x1004183D PMG_CST_CFG_CTL:
0x40006 BBL_CR_CTL3: 0x7E2801FF Misc EN: 0x4000840081 Gen PM Con1: 0x1008
Therm Status: 0x884B0000 POST Control=0xEA010303, Status=0xE6009601
BIOS initializations…
CPLD JTAG to normal mode… done.
BIOS initializations…
CPGC Memtest for Channel 0 ……………… PASS
ECC enabled: channel 0 MayCCTRL_DUNIT_REG=0x000200F3
5. After the installation completes, the system displays the following ONIE
prompt: ONIE:/ #
Installing a Third Party Operating System
Apart from the Dell Networking OS, you can also install a supported third
party operating system on the S3048-ON system. For more information on
installing a third party operating system, please check the ONIE documentation
at https://github.com/ opencomputeproject/onie/wiki/Quick-Start-
Guidehttps://github.com/opencomputeproject/onie/wiki/Quick-Start-Guide and
refer to the respective third party OS vendor’s website for OS installation
instructions.
Support Resources
The following support resources are available for the S3048ON system.
Documentation Resources
This document contains operational information specific to the S3048ON
system. For information about using the S3048ON, refer to the following
documents at http://www.dell.com/support:
16
Installing the S3048-ON System Quick Start Guide Dell Networking Command Line
Reference Guide for the S3048-ON System Dell Networking Configuration Guide
for the S3048-ON System For more information about hardware features and
capabilities, refer to the Dell Networking website at https://
www.dellemc.com/networking. For more information about the open network
installation environment (ONIE)-compatible third-party operating system, refer
to http://onie.org.
Issues
Issues are unexpected or incorrect behavior and are listed in order of Problem
Report (PR) number within the appropriate sections.
Finding Documentation
This document contains operational information specific to the S3048-ON
switch. For information about using the S3048ON, refer to the documents at
http://www.dell.com/support. For more information about hardware features and
capabilities, refer to the Dell Networking website at https://
www.dellemc.com/networking. For more information about the open network
installation environment (ONIE)-compatible third-party operating system,
refer to http://onie.org.
Contacting Dell
NOTE: If you do not have an active Internet connection, you can find contact
information on your purchase invoice, packing slip, bill, or Dell product
catalog. Dell provides several online and telephone-based support and service
options. Availability varies by country and product, and some services may not
be available in your area. To contact Dell for sales, technical support, or
customer service issues: Go to www.dell.com/support.
17
Notes, cautions, and warnings
NOTE: A NOTE indicates important information that helps you make better use of
your product. CAUTION: A CAUTION indicates either potential damage to hardware
or loss of data and tells you how to avoid the problem. WARNING: A WARNING
indicates a potential for property damage, personal injury, or death.
© 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and
other trademarks are trademarks of Dell Inc. or its subsidiaries. Other
trademarks may be trademarks of their respective owners.
References
- Home · opencomputeproject/onie Wiki · GitHub
- Computers, Monitors & Technology Solutions | Dell USA
- Support | Dell US
- Dell Networking Solutions | Dell USA
- GitHub: Let’s build from here · GitHub
- Dell Networking Solutions | Dell USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>