The PP4 is a High-Tech Product. To guarantee a smooth operation, it is necessary to respect the following rules. The manufacturer of this device will not take responsibility for damages through any disregard of the information provided in this manual. Warranty claims also will be voided in the case that the fixture housing is opened.
- Before powering on the fixture, make sure that the PP4 fans and air inlets are clean and not blocked.
- The PP4 doesn’t contain any user-serviceable parts. Opening the fixture will void all warranties.
Product Features
- Simplified wiring; each output supplies data and power to pixels over a single cable
- Control of multiple pixel strings simultaneously
- Any output can drive any number of pixels over multiple universes up to the full capacity of the driver
- Control of up to 2,040 individual pixels using Unicast E1.31 or Art-Net, and 1,190 pixels using Multicast E1.31
- Universe assignment up to 12 Universes
- Ethernet connection eliminates need for hardware “dongles” and special data wiring
- Power and Ethernet present indicators
- Multiple pixel types supported
- All configuration and status reporting is done using the built-in webserver
- Temporary IP address override for built in web server access
- Advanced configuration options included RGB color order, string length, pixel grouping, pixel type, reversed and zig-zag strings, ‘null’ pixels, DMX addressing range, universe spanning, gamma correction, and more
- Neutrik Powercon input and thru
- Simultaneous support of up to 4 different LED pixel types
- Data and power outputs are individually fused
- Built-in test patterns
Scenex Lighting PP4 LED Driver Specifications
- 4 output ports utilize data and power via standard 4 pin XLR connectors
- Supported pixels include : LPD6803 , LPD880X, WS2801, WS2811, TLS3001, 1903, 9813
- Power input: 100 – 240VAC, 50/60 Hz
- Power output: 5V DC / 40 Amp output
- 2 additional power injection ports
- Durable steel casing
- IP22 rating
- 1 ½ U Rack Mount ( ½ U required for cooling)
- Dimensions: 1.75 in x 17.25 in x 8.25 in / 45 mm x 440 mm x 210 mm
- Weight: 8 lbs. / 3.7 kg
- 2 x 10mm threaded mounting points for clamp attachment for truss
- Forced air cooling
- Operating temperature: 32-104°F / 0-40°C
XLR PIN OUT for PP4 Driver
XLR Pin # | Function |
---|---|
1 | Ground |
2 | Clock |
3 | Data |
4 | 5 Volts DC |
XLR Pin Out for PP4 Driver to Scenes Lighting Pixel Tape
XLR Pin # | Tape Wire | Function | Tape Type |
---|---|---|---|
1 | Yellow | Ground | WS2801/WS2811 |
2 | Blue | Clock | WS2801 only |
3 | Green | Data | WS2801/WS2811 |
4 | Red | 5 Volts DC | WS2801/WS2811 |
Accessing the PP4 Web Server
This discussion assumes that the PP4 controller is connected via a LAN cable
to your LAN, typically to an unused port on your router. All configuration of
the PP4 controllers is done via a web configuration page. The web page is
displayed by typing the IP address of the controller into a web browser’s
address bar. In order to access the web page the current controller IP address
must be known, and it must lie within the address range of the LAN to which
the controller is connected.
The initial access to the web page presents a bit of a chicken-or-the-egg
dilemma. In order to set the controller’s IP address we need to be able to
access the web page, but we may not be able to access the web page if the
existing IP address isn’t known, or isn’t valid for our network.
All controllers ship with a default IP address of 192.168.1.206. Almost all
small networks will use some variant of 192.168.x.y IP addresses. Of those,
the 192.168.1.x range is the most common. Since the 192.168.1.x addressing
scheme is common, it’s usually easiest to first try accessing the controller
at its default IP address of 192.168.1.206. To do that, open your web browser
and type 192.168.1.206 into the command bar (where you typically see the
http:// addresses), and press ENTER. If you see the controller’s web page
displayed, then you can skip ahead to the next section, where you see an image
of the web page. If you’re here, the 192.168.1.206 address didn’t work. The
most likely cause is that your network uses an address range other than
192.168.1.x. You can determine that with this simple procedure. Note that this
is a one-time procedure. Once you’ve overridden the default IP address with
one that’s compatible with your network, we’ll change the PP4s IP address to
be one that’s valid for your network to make future access to the web page
simple. The following procedure is good for Windows 7; other versions of
Windows will use a similar procedure. In the text that follows, bold and
capital letters are used to identify what you need to type or which screen
button to ‘click’, you need not use caps when actually entering the commands:
Press the WINDOWS button to open the start menu. Type CMD in the search bar and press ENTER. A black window should open. In the black window type IPCONFIG /ALL then press ENTER. (That’s IPCONFIG then a space, then a forward slash followed by the word ALL.)Scroll up if necessary using the scroll bar to display the first part of the text that has appeared in the window. Look for an area called “Ethernet Adapter Local Area Connection”. Within that area look for the line “IPv4 Address”. Generally, the number displayed will be: 192.168.x.y, where x will usually be 0 or 1, (sometimes higher) and y can be any number. The third digit, X in the example, is what you need to know. If X is 0, your LAN uses 192.168.0.X addressing. Other common IP ranges would be 2. X.X.X or 10. X.X.X. (The 169.254.X.X address range will be used if your PC is not connected to a router or is connected to a wireless router.) Now that you know the address range used by your LAN, you can override the factory default IP address of the PP4 and force it to have an IP address that’s within the range of your LAN. This is done by using the Temp IP Override button on the PP4. Using the information about your LAN’s address range, pick the override you need to use from this table Over-Ride Code
Purpose
- Display current IP address on LEDs, continue until restarted Force a temporary IP address of 2.2.2.2
- Force a temporary IP address of 10.10.10.10
- Force a temporary IP address of 169.254.74.73
- Force a temporary IP address of 192.168.0.206
- Force a temporary IP address of 192.168.1.206…..
Note:
Codes from 5 to 15 all force a temporary IP address of 192.168.X.206, where
X is the override code – 5. For example, over-ride code 15 forces a temporary
IP address of 192.168.10.206, because 15-5=10.
As an example, if you determine that your LAN uses 192.168.0.x addressing,
then you would use override 5 to force an IP address of 192.168.0.206 because
that is within the address range used by your LAN. If your IP address is of
form 2.X.X.X or 10.X.X.X or 169.254.X.X you would use over-ride codes 2, 3,
and 4 respectively. Overrides are done by use of the Temp IP Override button
on the PP4. Use this procedure: Determine the override code you need to use
per the discussion above, it will be in the range of 2 to 15. Once the
controller is powered up and the LEDs are lit, press AND HOLD the Temp IP
Override button. After about 2 seconds you will see the RED and GREEN LEDs
flash on and off together at the rate of one flash per second. Count the
flashes and release the PROGRAM button when the lights flash on for the number
of times equal to your override code. With our previous example, a LAN using
192.168.0.X addressing, we determine from the table that we need override 5.
So we would hold down PROGRAM until the LEDs come on for the 5th time, then
release it. After you release the Temp IP Override button the LEDs will come
on and stay on. Now you should be able to enter the override address into your
browser’s address bar and you should see the controller’s web page.
If you are unable to use the above procedure successfully, there is an
alternate method to access the controller page. Unplug your computer’s LAN
cable from your router and wire it directly to the Ethernet jack on the
controller. Reboot the computer and then use over-ride code 4 on the
controller. You should then be able to access the controller’s page at
169.254.74.73.
Note:
The IP address created by the override is temporary. Once you are able to
access the controller’s web page, change the IP address to an address that is
within the range of your LAN, save by clicking Update System Information, then
restart the controller. There is an additional use of the override; that is to
display the current IP address of the controller. This is useful if, for
whatever reason, do not know the IP address that the controller is set to. You
can use override #1 to display the IP address on the LEDs.
Over-ride code 1, IP address display
Use over-ride code 1 to determine the IP address of the controller when it
is not known. Press and hold the Temp IP Override button until the red and
green LEDs come on together for the first time, then release (over-ride code
1). The LEDs will now display the current IP address. For each digit, the
green LED will come on, then the red LED will flash a number of times
corresponding to the value of that digit. Then the green LED will go off. This
process repeats until all 12 digits of the IP address have been displayed, and
the entire process repeats continuously until the controller is restarted by
pressing the PROG button again, or by pressing the RESET button (all but PP4),
or by interrupting power to the controller. For the factory default IP address
of 192.168.1.206, you would see the following pattern on the LEDs: Brief pause
with both LEDs off, then green ON, then red flashes 1 time, then green off
Brief pause with both LEDs off, then green on, then red flashes 9 times, then
green off Brief pause with both LEDs off, then green on, then red flashes 2
times, then green off slightly longer pause, then next group begins) Once the
current IP address is known (factory default is 192.168.1.206), if it is
within the address range of your LAN just enter that IP address in your
browser’s address bar. If it is outside of the range of your LAN use the
override procedure described above.Once you have successfully accessed the
PP4’s web page, you will see a screen similar to the following:
In general, you will make configuration changes by entering the desired
value(s) using entry boxes, checkboxes, buttons, and drop-down lists. Then you
will click the corresponding UPDATE button for the changes to take effect.
Please note that there are several UPDATE buttons; when you make changes in
one area of the screen, you must press the proper UPDATE button, before moving
on to make changes in another area. In particular, each pixel output has its
own configuration line and its own UPDATE button. So when configuring outputs,
you would make all changes to output 1, then click that line’s UPDATE button.
Then move on to output #2 and repeat the procedure.
The web page is divided into 3 main sections: System Information, Universe
Selection, and Output Configuration.
System Information
The System Information section allows the user to view and/or change the following system settings:IP Address: This is the IP address that the controller will have when it is not overridden at startup. This IP address is used to access this web page, and is also used as the destination address if using E1.31 Unicast mode or Art-Net (described later). The IP address is entered as 4 separate numeric values. The controllers are shipped with a default address of 192.168.1.206. If you LAN uses 192.168.1.x addressing, you should be able to access the controller simply by entering that IP address into the URL bar of your browser. If your LAN uses a different address range, there is an over-ride mechanism, described earlier in this manual that allows you to use the PROGRAM button on the controller to force a different IP address at startup. Typically this is used to force an IP address in the range of your LAN, then you can access the web page, and change the IP address so that is within the address range of your LAN. To change the IP address simply click on all of the 4 IP address boxes and enter the desired values. When finished you must click the Update System Information button to save your changes. In order for the new IP address to take effect, you must then restart the controller, by pressing the RESTART CONTROLLER button at the lower left. Note that ONLY an IP address change requires a restart, all other changes take effect immediately when the corresponding UPDATE button is pressed. If you used the override procedure to access the controller, you should change the IP address now to one that is compatible with your network so that you can access the controller in the future without using the override. You will see a line at the top of the screen that shows the temporary IP address that is in use because of the override:
All pixels lit RED, GREEN, or BLUE respectively A bright pixel chases from start to end leaving dim pixels behind, RED, GREEN, and BLUE 35%, 50%, 75%, and 100% white all pixels. USE WITH CAUTION: 100% WHITE ON ALL PIXELS CREATES MAXIMUM LOAD ON THE PIXEL POWER SUPPLY. Pixel pairs to alternate between VIOLET and GREEN. A pattern of n RED pixels followed by n GREEN pixels followed by n BLUE pixels followed by OFF pixels, that chases through the entire range of pixels, where n is the test pattern number – 10. For example, test pattern 15 is a group of 5 pixels of each color (15-10=5).(Please note that the colors you observe may be different than those listed, this simply means that your pixels don’t use the standard R->G->B color order. Not to worry, this can be fixed later.)
Gamma Value may be set to any value in the range of 1.0 (no correction) to 3.0 (maximum correction) in increments of 0.2. Gamma correction is used to improve the dimming characteristics of some pixel types to make them have a more natural-looking dimming characteristic, more gradual at the low end similar to the dimming characteristics of incandescent bulbs. Gamma Correction works with all 12-bit pixel types such as TLS3001 and CYT3005 and works with 8-bit pixels if the string length is 55 pixels or less. After making any changes to any items in the System Information area, you must click the Update System Information button for the changes to take effect. With the exception of a change to the IP address, all changes become effective immediately and do not require a restart of the controller.
Universe Selection and Packet Statistics
This area is where you define the list of universes that the controller will respond to. The set of universes needed will depend on how your pixels or other devices are defined in the software package that sends out the E1.31 packets. This could be LOR, LightShowPro, Madrix, etc. Later in this manual, there will be a discussion that explains many of these terms and talks about the design of a pixel system. If you’re new to pixels, you can skip over the information here that you’re not familiar with, and then after reading the material later in the manual you will have a better understanding of how these configuration settings work.
Based on the settings that you use to address your pixels in your sequencing software, you will know how many universes, and which universes, need to be received by this controller. Typically the universe numbers are entered in order from lowest to highest. Unused universes may be left at 0. Valid universe numbers are 1-63998. There should be no duplications in the universe numbers used, in other words, don’t enter any universe number in more than one box. Universe numbers are entered simply by clicking on the appropriate entry box and entering the desired value. When finished, click the Update Universe Numbers button to save the changes. Universe number changes become effective immediately. Note that the selections here simply determine which set of incoming universes the controller will receive. In the next section, we will assign those universes to control specific pixel strings.
This section of the page contains 3 additional items of information for each
universe: Packets Received, Sequence Errors, and Invalid Packets. These are
display-only items. Packets Received lists the total number of packets
received for this universe since the controller was restarted. Sequence Errors
shows the number of packets that were missed or skipped over. Typically this
value will be rather small, but not necessarily 0. For example, the controller
will tend to miss some incoming packets when the web page is being updated,
although this is typically not visible because the packets come in so quickly.
Invalid Packets indicates the count of packets that were not proper E1.31/SACN
packets. This should rarely have a non-zero value.
Important: The first 7 universes can be used for pixel control data of any
type: Multicast E1.31, Unicast E1.31, or Art-Net. The last 5 universes cannot
be used for Multicast E1.31. If you use Multicast E1.31 you must only assign
the 1st seven universes to your pixel strings (see Output Configuration,
below).
Output
Type is a drop-down selection list that allows you to choose the type of pixel
(or another device) attached to this output. As of this time the following
pixel types are supported: 6803, 2801, GE Color Effects, 1804/2811, 16716,
880x, 981x and 3001. Non-pixel output types supported are Renard (57.6kbps)
and DMX.
Length in Pixels is where you enter the number of pixels that make up the pixel string or strip connected to this output. For output types Renard or DMX, the value entered here would be the number of channels of output desired divided by 3, since each ‘pixel’ uses three channels. As an example, for a full universe of DMX output, (actually 510 channels), you would specify a length of 170. This is because 170 pixels would use 510 channels. Group Size allows pixels to be controlled in groups rather than individually. This feature would typically be used either to reduce the number of channels needed or to simplify the programming of the pixels. When the group size is other than 1, instead of pixels being controlled individually, groups of pixels are controlled. For example, with a string length of 50 pixels and a group size of 5, the string would be controlled as 10 groups of 5 pixels and would use only 30 channels (10×3) instead of 150 channels (50×3). Color Order is a drop-down that allows the specific color order of the pixels connected to this output to be specified. This can be helpful if the particular pixel string or strip does not use the standard R->G->B color order. If the pixels do not light with the expected colors because they use a color order other than RGB, changing the color order to the proper sequence (often by trial and error), will correct the problem.
Start Address
Each output that is marked as in use, and has a length greater than 0, is
assigned a sequential block of DMX addresses. The length of this address block
is (Length in Pixels) X 3, because each pixel requires 3 channels, one for
each of its primary colors; red, green, and blue. Note that if pixel grouping
is used the number of channels needed will be reduced accordingly. The
operator can configure the starting address for each output. All pixels on
that output are then assigned consecutive addresses beginning with the
specified start address. The necessary channels may span across one or more
universe boundaries, depending on the start address and the number of channels
needed. When the end of a universe is reached (channel 510 is the last channel
used in each universe), channels will be assigned from the next selected
universe based on the order of universe selection (see Universe Selection and
packet Statistics).
In most cases, the selected universes will be assigned sequentially. For the
first controller, the starting universe will often be Universe 1. If using
Multicast for example, the first controller would typically be configured for
universes 1 through 7.
If a different group of universes is selected, this will affect how channel
addresses are assigned. For example, assume that the first 5 selected
universes (from left to right) are 1, 3, 5, 7, and 9. If we define output 1 as
having 200 pixels, then this output needs 600 total channels. Assume that we
start this output at Universe 1 Channel 1. Since there are only 510 useable
channels per universe, the last 90 channels will be assigned from Universe 3,
since Universe 3 follows Universe 1 in the universe selection list.
The selection of the start address for an output is done by entering the
starting Universe (from a drop-down list which will only show the list of
available universes), and a starting channel, a numeric entry from 1 through
508. Although not specifically required, it’s best to start every output on a
channel number of 1 or 1 plus a multiple of 3 (4, 7, 10…508). The example
below reflects the selected universe group consisting of universes 5 through
16.
You can see in this example, that a starting address of Universe 5 Channel 1 produced an ending address of Universe 6 (the next universe inline
channel 90. This is because the output needs 600 total channels, 510 from Universe 5 and 90 from Universe 6. The ending channel is calculated automatically by the controller, only the starting address can be entered.
Note:
Start Address and End Address values are NOT displayed for any output that is
not enabled or has a length of 0.
Reverse The Reverse check-boxes allow you to indicate that the associated string is ‘backward’, in other words the first pixel to light will actually be the last pixel of the string. An example where this feature would be useful is a roofline, where the controller is mounted at the mid-point, with one-pixel string (say #1) running to the left and another (say #2) to the right. Without the reverse feature, if you began lighting pixels in order, you would actually be lighting pixels beginning at the center of the roof, working left to the left end, then jumping back to the center and then working to the right. By selecting the check-box to indicate that the first string is reversed the pixel sequence will be as it should be, from left to right with no jumps.
Zigzag
The Zigzag feature is another feature that can simplify the pixel programming
by allowing the pixel addresses to flow in a more logical order. As an
example, say you have a matrix of 200 pixels arranged in 20 columns of 10
pixels. If you start at the bottom left you would string pixels 1-10 from
bottom to top in the first column, and then pixels 11-20 from top to bottom in
the 2nd column, and so on, basically zig-zagging up and down. When done, if
you lit pixels in order from the lowest address to the highest, you would see
a pattern that started at the lower left and zig-zagged up and down across the
matrix. When programming the pixels, it’s often easier if the pixels light in
a more natural order. In this example, we would use the zigzag feature to tell
the controller that the pixels reverse direction every 10 pixels. Now,
lighting sequential pixels produces the desired effect, the first column
lights from bottom to top, then the 2nd column from bottom to top, etc.
Null Pixels
Null pixels are pixels that are ignored by the controller and never lit.
The most common use of null pixels is to allow a longer length of wiring
between the controller and the start of a pixel string. Because the pixel
control signals aren’t designed to travel over long distances, it may not be
possible to use wire runs longer than about 20 feet. If the particular
installation requires a longer wire run than normal, this can often be
accomplished by inserting one or more extra pixels in the wire run between the
controller and the pixel string. Each of these pixels will regenerate the
control signals, enabling them to be run for another 20 feet or so. As an
example, if we needed to have a 100-foot wire run between the controller and a
pixel string, we might use 4 null pixels, one at 20 feet, 40 feet, 60 feet,
and 80 feet. Even though the total run was 100 feet the maximum distance
between pixels is only 20 feet because of the null pixels.
Another use for null pixels is when you don’t need the full length of your
string. Say you have a 50-pixel string but only need 48 pixels lit. If it’s
more convenient to have the unused pixels at the start of the string rather
than at the end, set the string length to 48 at set null pixels to 2.
Refresh Rate
This is a displayed value that shows the approximate refresh rate of the pixels connected to this output. It is affected by pixel type and string length.
Special Purpose Buttons
There are 3 special buttons at the bottom of the page, and one number entry
box. Refresh Page simply refreshes the page without changing any
configuration. Since the web page never updates by itself, you would use the
Refresh Page button, for example, to see updated packet statistics or updated
system up-time.
Restart Controller
simply does a reset of the controller, the same as would happen if you
removed then reapplied power. It would most commonly be used after a change of
the IP address since an IP address change does not become effective until the
controller restarts.
The System Command button is used to perform some infrequently used functions,
based on a numeric value that is entered into the number box to its left.
There are 3 system commands presently defined: Erase system configuration
memory. This will wipe out all configuration data with the exception of the IP
Set test default configuration. This function sets all outputs for type 2801
pixels, 50 pixels per string. Set as-shipped defaults. This sets 4 different
pixel types on the 4 outputs. As an example, to return aboard to the factory
default configuration (other than IP address) you would enter 10 in the system
command box and click System Command. Then enter 20 and click System Command.
Then enter 30 and click System Command.