GERMAN POOL GPU Series Central Storage Electric Water Heater User Manual
- June 12, 2024
- GERMAN POOL
Table of Contents
GERMAN POOL GPU Series Central Storage Electric Water Heater
Product Information
- Product Name: GPU-6.5SSJ
Features
- Stainless Steel Inner Tank
- Thermal Insulation
- Heating Element
- Water Supply Source: Main supply or water tank supply
- Rated Pressure/Max. Inlet Water Pressure: 1.0 MPa / 0.6 MPa
- Pressure & Temperature Relief Valve
- Combined Thermostat / Cutout
- Water Resistance Conformity: IPX4
- Certifications: IEC 60335-1, IEC60335-2-21
Specifications
Model| Rated Capacity (Litre)| Rated Voltage (1Phase)| Rated Voltage (3Phase)|
Rated Power (kW) (1Phase)| Weight
---|---|---|---|---|---
GPU-6.5SSJ| N/A| Volt| Volt| kW| N/A
Product Usage Instructions
Warnings
- Do not allow children to touch or play with the water heater. Supervision is required during use to prevent the danger of scalds, electrical shock, or injuries.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- An electric-leakage protection device must be installed in the power inlet. The electric current of this protection device should be below 30mA.
- Please install the water heater in accordance with the instructions stated in the user manual. German Pool will NOT provide warranty service on any product installed with unauthorized components or devices.
- The PTV device must be tested and operated regularly (suggested once every 3 months) to remove calcium carbonate deposits and to ensure that it is not blocked.
- The PTV drain pipe must be installed continuously downwards at an angle and the surroundings must not be frosted. The drain pipe must be left open to the atmosphere to ensure that the hot water drips from the PTV will not endanger personal safety or cause property damage.
Installation Instructions
Please refer to the user manual for detailed installation instructions.
Product Structure
Please refer to the user manual for detailed information about the product
structure.
Wiring Diagram
Please refer to the user manual for the wiring diagram.
Warranty Terms & Conditions
Please refer to the last page of the user manual for warranty terms &
conditions.
Please register your warranty information now! For Warranty Terms & Conditions, please refer to the last page of this user manual.
Warnings
- Do not allow children to touch or play with the water heater. Supervision is required during use, in order to prevent the danger of a scald, electrical shock or any other injuries.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- If the temperature is set above 50°C, cold water must be mixed in to prevent the danger of a scald.
- An electric-leakage protection device must be installed to the power inlet. The electric current of this protection device should be below 30mA.
Warning
Please install a water heater in accordance to the instructions stated on this booklet. German Pool will NOT provide warranty service on any product installed with unauthorized components or devices.
Warning
- The water heater must be installed together with a Pressure and Temperature Relief Valve (PTV), so that when the water temperature inside the tank rises to 90°C or when water pressure reaches 1000kPa, hot water will be released through the drain pipe of the PTV.
- The PTV device must be tested and operated regularly (suggested once every 3 months) to remove calcium carbonate deposits and to ensure that it is not blocked.
- The PTV drain pipe must be installed continuously downwards at an angle and the surroundings must not be frosted. The drain pipe must be left open to the atmosphere, and to ensure the hot water drips from the PTV will not endanger personal safety or cause property damage.
Features
German Pool GPU Series Central Storage Electric Water Heater is designed for multi-point application. It conforms to the Standards of the International Electro-technical Commission (IEC Standards) and complies with safety standards and waterworks regulations worldwide. GPU is built-in with “5-Tier Safety Device” for absolute safety:
Stainless Steel Inner Tank
| 。
Constructed of Japanese heavy gauge stainless steel, specially made for high temperature and pressure applications. It is durable and free of rust, corrosion, deformity and hassle.
---|---
Thermal Insulation
|
Maximum thermal insulation is achieved by high-density polyurethane foam injection moulded between the inner tank and outside casing.
Heating Element| 。 Prime quality stainless steel heating element ensures maximum thermal efficiency even in places where different power rating / voltage applices.
Water Supply Source
|
Main supply or water tank supply.
Rated Pressure /
Max. Inlet Water Pressure
|
1.0 MPa / 0.6 MPa
Pressure & Temperature Relief Valve| When water temperature reaches 90°C, or
water pressure reaches 1MPa, water will be released through the Temperature
Relief Valve.
Combined Thermostat / Cutout|
Combined Thermostat/Cut-Out provides automatic temperature control at
preset temperature to accommodate individual bathing habits and save energy; built-in thermal cut-out ensures safety.
Water Resistance
| IPX4
Conformity
|
Electrical Product (Safety) Regulation, Hong Kong.
Certifications
| IEC 60335-1 IEC60335-2-21
- Automatic Thermostatic Control
- Thermal Cutout
- Temperature Relief Valve
- Pressure Relief Valve
- Anti-Back Syphon Device
Specifications
Specifications are subject to change without prior notice.If there is any inconsistency or ambiguity between the English version and the Chinese version, the Chinese version shall prevail. Refer to www.germanpool.com for the most up-to-date version of the Operating Instructions.
Model
| Rated Capacity|
Rated Voltage
|
Rated Power
|
Weight
---|---|---|---|---
Litre
| Volt (1Phase)| Volt (3Phase)| kW (1Phase)| ) kW (3Phase)|
kg
(Net Weight)
|
k (Filled)
GPU-6.5SSJ-JS| 25L| 220~| N/A| 3| N/A| 16.5| 41.5
GPU-6.5SSJ-JB| 25L| 220~| N/A| 3| N/A| 16.9| 41.9
GPU-6.5SSJ-JF| 25L| 220~| N/A| 3| N/A| 16.7| 41.7
Installation Instructions
Pre-Installation Notice
Installation should be done by a licensed technician using the supplied parts.
German Pool is not responsible for any defect or damage caused by incorrect or
unauthorized installation.
Positioning
Position the water heater near the water tap/point of use in order to minimize
heat loss. For wall-mount style, appropriate anchor screws must be used and
the wall should be strong enough to withstand the weight of water heater. Keep
a minimal distance between the wall and the water heater. you can also use the
mounting bracket for positioning.
Connecting PTV and Inlet/Outlet Pipes
A Pressure & Temperature Relief Valve (PTV) is supplied with each GPU water
heater. Water will be released through the PTV when the water temperature
reaches 90˚C or when water pressure reaches 1000 kPa in the inner tank. (It is
normal that a small amount of water may drip out.)
PTV and water inlet & outlet must be installed according to the following instructions:
- Fit PTV to the marked position (normally it is located on the upper side of the water heater and is labeled “PTV”).
- When connecting the pipe,the PTV must point downward.The outlet of the discharge pipe connecting the PTV must be positioned approximately 25-50mm away from the ground so that it is easily observable when hot water is being drained to ensure safety.
- Connect the inlet pipe (blue) with water supply. Then connect the outlet pipes (red) with supply pipe leading to points of use. The diameter of piping should be 1/2” BSP.
- Turn on the hot water tap. Turn on water supply switch until the inner tank has been filled up with water. The inner tank has been filled up when water flows from the water tap.
Electric Wiring
Use an independent wire (refer to table below) leading from the meter box and
connect it to an independent on/off switch outside the bathroom. Extend the
wire through the grey wire grip on the water heater. Dismount the bottom plate
and wire up Neutral (N), Life (L) and Earth terminals. This water heater must
be earthed at all time.
Power Switch
The external switch is used to completely disconnect water heater from power
supply. It should disconnect all poles, and a contract separation of at least
3mm must be present.
Testing
When the piping and wiring are connected and inner tank has been filled with
water, switch on the power. The indicator on the water heater will be lit.
Turn control knob to the desired temperature (Max. temperature is 75°C). Do
not use the control knob as an on/off switch.
WARNING!
The water heater must be permanently and reliably connected to the water pipe
and must not be connected with a hose.
WARNING!
After initial installation and water and electricity testings, if the storage water heater will not be put to use immediately after testing is completed, make sure to follow these instructions:
- Disconnect water and power source;
- Completely drain the residual water
- When the water heater is finally put to normal use, user MUST first completely fill up the water heater with water BEFORE reconnecting the power source and commencing heating.
NOTE:
If the water source is from underground water or near river area where
seawater intrusion is possible, user MUST COMPLY with all of the above steps
to ensure proper function of water heater.
! INSTALLATION REQUIREMENT
When installing the water heater, must leave ample space for future
maintenance and repair.
The minimum requirements are:
- at least 100 mm space from the ceiling
- at least 200 mm on either side of the wall
- at least 300 mm underneath the heater
WARNING!
The water heater must be installed in a location that is easily accessible for
repair and replacement. If water heater is installed in a location not easily
accessible, German Pool will not be held responsible for any damage or loss,
peripheral or otherwise, incurred during reparation and replacement.
Pressure & Temperature Relief Valve (PTV)
- The discharge pipe connecting to the PTV must be pointing downward and be left open to the atmosphere in a frost-free environment.
- Turn the lift handle or rotational cup of the PTV regularly in order to prevent deposits in water causing blockage to the easing gear.
- When water is discharged through PTV pipe, shut off power and water supply immediately. Then contact our Customer Service Centre for repair. (It is normal that small amount of water may drip out.)
Under normal working conditions, incoming pressure should not exceed 0.6 MPa. Otherwise, a separate pressure control device is necessary. (It is normal that small amount of water may drip from PTV after installation of pressure limiting valve.)
Note
When incoming water pressure exceeds 0.6 MPa, German Pool will not provide any
repair service until a pressure control device is installed.
Draining
To drain out water from the inner tank, first switch off both power and water
supply. Let hot water inside the inner tank cool down. Then unscrew the drain
pipe nut to release water.
Source of Water Supply
If the water source is a river, a well, or underground water or has relatively
high mineral content, user must clean the heating element regularly to ensure
it will operate at optimum thermal efficiency.
Water Shortage
During water shortage, do not drain water from inner tank. The heating element
would be damaged if it is not submerged under water. When water supply
resumes, turn on hot water tap and let water flows through the shower head
before switching on the power.
Product Structure
- Anti-Back Siphonage
- Device
- Outlet (Hot)
- Inlet (Cold)
- Combined Thermostat / Cutout
- Drain
- Pressure & Temperature
- Relief Valve (PTV)
Caution: After confirmation of installation location, properly secure the mounting bracket with screws on the wall, align the holes of the back plate of the water heater with the mounting bracket, and downwardly hang the water heater.
Wiring Diagram
Warranty Terms & Conditions
Under normal operations, the product will guarantee a 1-year full warranty
provided by German Pool (effective from the date of purchase). This warranty
is not valid until customer registration information is received by our
Service Centre within 10 days of purchase via one of the following means:
- Visit our VIP App and register online: (Scan the QR Code on the left) 2)
- Visit our website and register online: www.germanpool.com/warranty
- Complete the attached Warranty Card and mail it back to our Customer Service Centre.
- Customer who fails to present the original purchase invoice will not be eligible for free warranty service.
- Customers should always follow the operating instructions. This warranty does not apply to:
- labor costs for on-site installation, check-up, repair, replacement of parts, and other transportation costs;
- damages caused by accidents of any kind (including material transfer and others);
- operating failures resulting from applying incorrect voltage, improper usage, and unauthorized installation repairs.
- This warranty is invalid if:
- the purchase invoice is modified by an unauthorized party;
- the product is used for any commercial or industrial purposes;
- the product is repaired or modified by unauthorized personnel, or unauthorized parts are installed;
- the serial number is modified, damaged, or removed from the product.
- German Pool will, at its discretion, repair or replace any defective part.
- This warranty will be void if there is any transfer of ownership from the original purchaser.
Customer Service & Repair Centre
CentreHong KongUnit B, G/F, Sunshine Kowloon BayCargo Centre, 59 Tai Yip
Street, Kowloon Kowloon, Hong KongTel: +852 2333 6249Fax: +852 2356 9798
Email: repairs@germanpool.comMacauA
Read User Manual Online (PDF format)