SPECIFICATIONS
Technology | Lithium Iron Phosphate |
---|---|
Nominal Voltage | 12.8 V |
Fully Charged Voltage (FC) | 14.6V |
Fully Discharged Voltage (FD) | 9.2V |
Capacity (Ah) | 300Ah |
Recommended Discharge Terminated Voltage | 10V |
Battery Discharge Terminated Voltage | 9.2V |
Battery Charge Voltage | 14.2V |
Max Continuous Charge Current | 200A |
Heater Function
| Battery pack includes heater for heating cell module temperature up when battery pack is charged in a freezing environment
Standard Charge Method
| 0.2C CC (constant current) charge to FC, then
CV (constant voltage FC) charge till charge current decline to $0.05C
Inner Resistance| $10mO
Certifications| ETL, CE, UKCA, UN38.3, UL 2054
Operating Temperature
| Charge: -4°F (-20°C) to 131°F (55°C)
Discharge: -4°F (-20°C) to 131°F (55°C)
Storage Temperature1
| 1 month> 113°F (45°() to 131°F (55°C) – Max 80% RH
3 months> 77°F (25°C) to 113°F (45°() – Max 80% RH
6 months> -4°F (-20°C) to 77°F (25°C) – Max 80% RH
Humidity
| Operating: 5% to 90 % RH
Storage: 45% to 85% RH
BMS Leakage Current| 20uA in Shutdown Mode
IP Requirement| IP67
Dimensions (LxWxH)| 19.6in x 14.9in x 8.11in (498mm x 379mm x 206mm)
Weight| 70.5Ibs (32kg)
WARNINGS
- Only wire 8 batteries maximum in parallel
- Wire a maximum of 4 in series
- Do not get wet
INTERFACE DESCRIPTION LED (POWER BUTTON) INDICATORS
VARIOUS POWER MODES
Press button for more than 3 seconds and release. The battery will enter sleep
mode. The LED will blink. Power off mode should only be used for long term
storage or to reset the BMS. Use sleep mode to disable output power of
batteries.
MOBILE APP 8
Scan the QR code to download the Go Power! Connect App for use with the Sun
Cycle® Advanced Lithium Battery.
BATTERY WIRING
*cables purchased separately
HOW TOUSE
To prevent a surge current, perform a “pre-discharge” as outlined in the steps
below.
-
Step 1 – Ensure all batteries are in Power Off mode.
-
Step 2 – Connect batteries following the series or parallel connection found at gopowersolar.com/advanced-lithium-wiring. The Battery Inter-Connect Cable must be installed for each battery pack followed by a Battery End Cap Terminating Resistor cable on the last battery.
-
Step 3 – Ensure battery pack terminals are correctly installed and connected to
the inverter system. -
Step 4 – Press the power button on one of the battery packs for 3 seconds to wake up all battery packs from Power Off mode. The LED indicator will turn on.
NOTE: Batteries are in Power Off mode when unboxed. Press the Power
button for 3 seconds to turn on. If it doesn’t turn on, you will need to
charge the battery.
The batteries need to be configured before they can be used. Please see
battery manual for instructions on battery configuration.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>