AcuityBrands P6300 Trac Adapter Installation Guide
- June 12, 2024
- AcuityBrands
Table of Contents
AcuityBrands P6300 Trac Adapter
FIXTURE INSTALLATION
- Step 1 Find the latch and the polarity line. Align parts as shown and insert the adapter box into the track. (Fig. 1)
- Step 2 Pull down the latch while rotating the adapter box 90 degrees clockwise. (Fig. 2)
- Step 3 Final Position: Latch snaps into place between extrusion rails. Arrows on latch point toward the polarity line. (Fig. 3)
SECOND CIRCUIT POSITIONING
- Step 1 Raise the contact marked “P” (on switch side) by inserting a thin screwdriver blade under contact. Pull up into position as shown. (Fig. 4)
- Step 2 Insert contact support (supplied with 2-circuit Trac section) by tilting and snapping into position under the “P” contact as shown. (Fig. 5)
- Step 3 Ensure contact support is snapped and locked into position. (Fig. 6) Follow instructions for inserting into track.
Juno Trac adapter size and style may vary.
TROUBLESHOOTING
Problem | Cause | Remedy |
---|
Fixture doesn’t turn on
| Track not energized| Ensure track has power
Adapter switch is in the “Off” position| Ensure the power switch on the track
fixture adapter is in the “On” position, see Fig. 9
Fixture installed incorrectly
| Ensure fixture is installed correctly, with the arrows on the latch pointing
towards the polarity line as shown in Fig. 3
Ensure contacts aren’t bent from installing the fixture incorrectly, see Fig.
7
“P” Contact adjusted incorrectly
| Ensure “P” contact isn’t bent from adjusting incorrectly, see Fig. 8
Bent contact from adjusting the wrong contact, see Fig. 4, 5, & 6 for proper
adjustment method
WARNING Read all of these installation instructions before installing.
CONTACT
- One Lithonia Way
- Conyers, GA 30012
- 1-800-705-SERV (7378)
- www.acuitybrands.com.
©2020 Acuity Brands Lighting, Inc. P6300 Rev 10/2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>