Breathe Safe HEPA H14 Variable Speed Pressuriser Owner’s Manual
- June 1, 2024
- Breathe-Safe
Table of Contents
- HEPA H14 Variable Speed Pressuriser
- INSTALLATION
- SAFETY
- CRITICAL PARTS & MAINTENANCE SCHEDULE
- OPERATOR GUIDE
- Specifications – Pressuriser
- Parts List
- TECHNICAL DETAILS
- SMOKE EMITTER CABIN PRESSURE LEAK TEST
- CABIN SEALING TEST PROCEDURE
- COMMISSIONING PROCEDURES – CABIN PRESSURISER
- USER SETTINGS INSTRUCTIONS
- DATA DOWNLOAD
- INPRESS TL WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Parts and Service Manual
CATERPILLAR
992K / 994H WHEEL LOADER
HEPA H14 Variable Speed Pressuriser
HEPA H14 Variable Speed Pressuriser | INPRESS TS Cabin Display with CO2 Sensor
| HEPA Return Air Filter
+ Activated Carbon
Controlled Document: M0150
Issue Date: 08/09/23
Revision: 1
+61 7 3276 7833
www.breathe-safe.com.au
sales@breathe-safe.com
62 Mica Street, Carole Park, 4300, QLD
INSTALLATION
INSTALLATION OVERVIEW
Manufacturer| CATERPILLAR
Type| Wheel Loader
Model| 992K / 994H
Cabin Pressure Max|
Set Auto Cabin Pressure|
SAFETY
WARNING
THE PRESSURISATION SYSTEM DESCRIBED IN THIS MANUAL HAS THE FOLLOWING AREAS
WHICH MAY BE DANGEROUS IF NOT TREATED WITH GREAT CARE.
QUALIFIED STAFF MUST WEAR THE CORRECT PERSONAL PROTECTIVE EQUIPMENT WHEN
CLEANING AND SERVICING THIS UNIT DUE TO DUST AND FIBRES WHICH MAY BE CAUGHT BY
THE STAGES OF AIR FILTRATION DURING NORMAL UNIT OPERATION.
THE ELECTRICAL POWER SYSTEM IS SUPPLIED BY 12V DC OR 24V DC AND NO WORK SHOULD
BE CARRIED OUT ON THE PRESSURISER SYSTEM WITHOUT THE CORRECT SAFE WORK
PROCEDURES AND ELECTRICAL SAFETY MEASURES BEING TAKEN, AND ALL RELEVANT
CIRCUIT BREAKER OPENED TO ISOLATE THE CIRCUIT.
THE AIR FILTRATION SYSTEM MAY HAVE SEVERAL TYPES OF HIGH-SPEED ROTATING
EQUIPMENT INSTALLED WITH VERY SHARP EDGES. ENSURE ALL SAFETY GUARD ARE IN
PLACE WHILE THE SYSTEM IS RUNNING.
Please be aware that HEPA filters cannot be cleaned and must be replaced at
the end of their lifecycle or if filter media has been damaged. Particulate
Behaviour
This is the length of time it takes for a particle to drop from a height of
1.5m in STILL air. Warehouses and workshops do
not have still air, so hazardous airborne particulates may remain in air for
longer, increasing chance for workers to breathe in dust. Ensure PPE is worn
when installing this system.
CRITICAL PARTS & MAINTENANCE SCHEDULE
Maintenance Schedule
The following tables show our suggested maintenance schedule for all units.
Please note that site conditions may alter this.
Excludes high corrosion environments.
Data download is required to claim the 3-year warranty on Brushless Blower
Motor.
Inspect every 500 Hours and replace when filter is full*
Component / System | Action Required |
---|---|
Turbo Pre-cleaner | Check operation of the Turbo Pre-Cleaner. |
Pressuriser Blower | Ensure blower is operational. |
HEPA Primary Filter p/n: 500000 | Inspect filter capacity indicator. |
Replace HEPA filter when 80% or greater. Vacuum out housing before replacing
the filter elements.
HEPA Return Air Filter P/N: 500011| Vacuum inside cabin floor before
replacing filter.
Filter Frame Assembly, Mounts, Seals and Filter Housing| Check door seals, all
bolts, screws, and all mounts are secure.
Check the filter canister & ensure it is correctly fitted.
Check latches are operational and in good order.
Replace / Re-tension fixtures and fittings required.
15,000 Hours / 36 months*
Component / System | Action Required |
---|---|
500 Hour Inspection | All 500-hour inspection actions. |
Pressuriser’s Blower 200002 | Replace BRUSHLESS Pressuriser blower. |
Critical Parts
Item| Part Number| Qty.| Description| Service
Interval
1| 500000| 1| Fresh Air HEPA H14 Filter (Tested as per EN1822)| 1000 Hours
(>80% fan capacity)
2| 500011| 1| HEPA Return Air Filter| 500 Hours
3| 200002| 1| Brushless Blower Motor – 24V| 15,000 Hours
4| 200027| 1| BreatheSafe Digital Display – Data Recorder (INPRESS TS)|
5| 500069| 1| Filter Activated Carbon|
Filter service hours are subject to cab sealing efficiency, site conditions and correct system use.
Suggested Schedule Servicing Fan Capacity Indicator
The filter is serviceable if the motor capacity is between 10% & 80%. We
recommend that the filter is changed if the capacity is over 80%.
*Site dependent
OPERATOR GUIDE
OPERATORS CHECKLIST
PRE-START
1.| Visually inspect the BreatheSafe system for any damage.
2.| Visually inspect the cabin for any damage to doors, windows, seals.
3.| Please remove dust & debris from shoes and clothes before entering
the cabin.
4.| Ensure door(s) and windows are closed correctly.
5.| Start engine and turn HVAC on to speed 2 (medium speed).
6.| After fixed speed delay, the BreatheSafe display will show 50
Pascals or pre-set value.
The system is working correctly when the
pascal value is green.
> > There is no further action required < <
NORMAL OPERATING CONDITION
Cab Air Conditioning
BreatheSafe recommends OEM air conditioning fan is set at mid speed or greater
to circulate air around the breathing zone and minimise CO₂.
Acceptable operating range for BreatheSafe fan 10-80%. >80% recommend
maintenance.
ALERTS
Fixed Fan Start Delay
- Allows the operator to carry out pre-start checks – limiting at 30% fan speed, press the red text to disable.
CO₂ Level Alert (if equipped)
- Ensure air conditioning fan is set at mid speed or greater to circulate air and minimise CO₂.
Low Pressure Alarm
- Cabin is not maintaining positive pressure – check doors and windows are closed correctly.
- Refer to maintenance department to check filters and cabin sealing. Ensure filters are serviceable.
Check Filter
- Reminder to inspect or replace filter. Service hour meter requires re-set.
- Refer to maintenance department.
Specifications High-Capacity HEPA Pressuriser
Blower | : Brushless Blower P/N 200002. |
---|---|
Protection | : Locked Rotor Protection (Sub Zero Environments) Under Voltage, |
Under/Over Current & Over Temperature.
Voltage| : 24VDC.
Current Draw| : 11 amps (peak). *Note: Motor has slow start to stop excessive
in-rush current.
Air Flow| : Up to 30-300 m3 /h or 50-215 CFM.
Pre-cleaner| : Integrated VLR (Very Low Restriction). Turbo Pre-Cleaner.
Filter Element| : BreatheSafe HEPA Primary Filter (H14=99.99% MPPS) TESTED AS
PER EN1822 – P/N 500000.
Plugs & Fittings| : Mining Spec. Deutsch electrical plugs as standard.
Construction| : High strength composite construction.
Serviceability| : Easy access HEPA filter with twist-lock (TL) dust cap single
assembly.
Mounting| : Heavy Duty adjustable mounting brackets.
Design| : Fully designed in SolidWorks 3D CAD & Ansys Engineering Simulation
Software.
FEA Testing| : Critical components FEA (Finite Element Analyst) tested in
Solid Works Simulation.
CFD Testing| : CFD (Computational Fluid Dynamics) simulations in Flow Works to
ensure optimum air flow through the system.
Specifications – Pressuriser
SPECIFICATIONS HIGH-CAPACITY HEPA PRESSURISER
List of Abbreviations
DH| Dual HEPA
DHPR| Dual HEPA Powered Recirculation
DHAC| Dual HEPA Activated Carbon
DHACPR| Dual HEPA Activated Carbon Powered Recirculation
CPM| Cabin Pressure Monitor
CPU| Central Processing Unit
DB| Decibel Sensor
DPM| Diesel Particulate Matter
GAS| Gas Sensor
HEPA| High-Efficiency Particulate Air Filter
HPAFU| High Pressure Air Filtration Unit
HRAF| HEPA Return Air Filter
HVAC| Heating Ventilation and Air Conditioning
MAF| Mass Air Flow
OEM| Original Equipment Manufacturer
PM| Particulate Mass
RH| Relative Humidity
TEMP| Temperature
TS| Touch screen
UI| User Interface
VMS| Vehicle Monitoring System
VS| Vibration Sensor
OGSP| OnGuard Sensor Pod
CO2s| CO2 Sensor INPRESS TS
Parts List
Item No. | Qty. | Description | Part No. |
---|---|---|---|
1 | 1 | Pre-cleaner Hood & Rotor Assy | 200004 |
2 | 4 | Pre-cleaner Injector Ring | 200005 |
3 | 1 | TL Fan Blade (inc. in #7) | 200006 |
4 | 1 | TL Nose Cone / Pre-cleaner | 200007 |
5 | 1 | TL Motor Housing | 200008 |
6 | 1 | TL Filter Housing | 200009 |
7 | 1 | 24v DC Brushless VSD Motor & TL Fan Blade | 200002 |
8 | 1 | O Ring Seal Kit 2 Parts | 200010 |
9 | 1 | Included in 8 | 200011 |
10 | 1 | Wiring Sleeve | 200012 |
11 | 1 | HEPA H14 Filter | 500000 |
12 | 3 | M6 Nyloc Nut | 300218 (M6NYL) |
13 | 3 | M6 x 55mm Hex Bolt | 300982 (M655B) |
14 | 4 | M8 x 190 Hex Bolt | 301136 (M8190B) |
15 | 8 | M8 x 22mm O/D HD Washer | 300230 (M8222HTW) |
16 | 4 | M8 Nyloc Nut | 300249 (M8NYL) |
17 | 5 | M4 x 75mm Pan Head Phillips Screw | 300162 (M475PBH) |
PARTS LIST – TL4 24V DC PRESSURISER UNIT
PRESSURISER ASSEMBLY No: 200000
Old Part Number: TL4
www.breathe-safe.com
PART NO. TLF7O0ENI \
SERIAL NO. ABO186 \
TEST DATE: 2022/04/26 \
Breathe safe
Air Purification
HEPA H14 GLASS FIBER FILTER i
TESTED METHOD EN1822 A,
EFFICIENCY 99.995% @0.3 MICRONS y)
Support: 1300 667 597
sales@breathe-safe.com
Item No.| Part No.| Rev| Description| Qty|
Colour| Category
---|---|---|---|---|---|---
1| 100007A01| 0| High Pressure Unit Module| 1| Black Satin 27219268|
Module
2| 100007F01| 0| Fresh Air Inlet Assy| 1| Black Satin 27219268| Assembly
3| 100007P01| 1| Pipework Module| 1| Black Satin 27219268| Module
4| 100007M01| 0| Monitor Mount Module| 1| Black Satin 27219268| Module
5| 08960| 0| Return Air Filter Assy| 1| Satin Black MX88-124| R.A.F.
Frame
Kit Part Number: 700591
PARTS LIST – PRESSURISER MODULE
Item No.| Part No.| Rev| Description| Qty|
Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
1| 250516| []| MK3 Universal Cap-Mount MS| 1| –| –| (As Req’d)| Stock
Item
2| 200000| []| HPAFU 24VDC VSD TL4| 1| –| –| –| Stock Item
3| 250502| []| Canister MK3 316SS| 1| –| –| –| Stock Item
4| 250508| []| Duct Outlet MK3 Adj SS| 1| –| –| –| Stock Item
5| 250018| []| TL4 Mount Brkt| 1| –| –| –| Stock Item
6| 250503| []| Duct Vert Slim Line MK3-TL LH| 1| –| –| –| Stock Item
7| 250050| [*]| TL WC Cover Slim Duct LH| 1| –| –| –| Stock Item
PARTS LIST – FRESH AIR MODULE
Item No.| Part No.| Rev| Description| Qty|
Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
1| 100007F02| 0| Fresh Air Inlet Weldment| 1| –| –| Black Satin
27219268| Weld Assy
2| 100007-F287| 0| Blanking Plate| 1| Mild Steel| 3| Black Satin
27219268| Part
3| 15134| 0| Clamping Plate Weldment| 1| –| –| Satin Black MX88-124|
Weld Assy
PARTS LIST – PIPEWORK MODULE
Item No.| Part No.| Rev| Description| Qty|
Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
1| 100007P02| 0| Stauff Bracket Weldment| 2| –| 1| Black Satin 27219268|
Weld Assy
2| 300388-0100| –| 76 SS Tube @100L| 1| Stainless Steel| 1.6| (As
Req’d)| Pipework
3| 300388-0120| –| 76 SS Tube @120L| 1| Stainless Steel| 1.6| (As
Req’d)| Pipework
4| 300388-0250| –| 76 SS Tuve @250L| 1| Stainless Steel| 1.6| (As
Req’d)| Pipework
5| 300388-0450| –| 76 SS Tube @450L| 1| Stainless Steel| 1.6| (As
Req’d)| Pipework
6| 300388-0750| –| 76 SS Tube @750L| 1| Stainless Steel| 1.6| (As
Req’d)| Pipework
7| 200305| –| 76.2x45LD Elb| 1| Silicone| –| –| Pipework
8| 200307| –| 76.2x90LD Elb| 3| Silicone| –| –| Pipework
9| 200308| –| 76.2x90SD Elb| 1| Silicone| –| –| Pipework
10| 300001| –| Clamp Hose W 65-89 SS| 13| –| –| –| Pipework
11| 300480| –| Stauff Shell GR7 76.1 Black| 4| –| –| –| Pipework
12| 300481| –| Stauff GR7 Cover Plate| 2| Zinc Plated| 5| (As Req’d)|
Pipework
13| 300842-0120| –| 76 ID Silicone Hose @120L| 1| Silicone| –| –|
Pipework
PARTS LIST – MONITOR MODULE
Item No.| Part No.| Rev| Description| Qty|
Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
1| 11148| 1| Monitor Brkt Base| 1| Mild Steel| 3| Satin Black MX88-124|
–
2| 250100| []| Monitor Box Small| 1| Zan| –| (As Req’d)| Stock Item
3| 250106| []| CO2 Brkt Universal| 1| –| –| (As Req’d)| Stock Item
PARTS LIST – RETURN AIR MODULE
Item No.| Part No.| Rev| Description| Qty|
Material| Thickness| Colour| Category
---|---|---|---|---|---|---|---|---
| | | | | | | |
| | | | | | | |
| | | | | | | |
PARTS GA
Carbon Filter Carrier Removal
- Ensure all relevant circuit breakers are open and the electrical circuit is isolated.
- Unlock & open the door (Fig 1)
- Uncouple both filter latches (Fig 2)
- Pull the filter in the opposite direction off the air flow arrows, until clear (Fig 3)
- Full the filter towards you and remove (Fig 3)
- Clean the filter housing of all debris.
- To replace the filter, assemble the components in reverse order.
Carbon Filter Service Kit
- Please follow the steps shown for the Filter Media Carrier Removal, to remove the carrier from the case.
- Unscrew & remove the 4-off M5 screws (Fig 1)
- Lift out the solid Media Filter (Fig 2)
- Lift out the Secondary HEPA Filter (Fig 2)
- Clean the filter housing of all debris.
- To refit, assemble the components in reverse order.
TECHNICAL DETAILS
Connections: 200027
Item | Destination |
---|---|
1 | PIPE A – AMBIENT PRESSURE – OUTSIDE |
2 | PIPE B – POSITIVE PRESSURE – INSIDE |
3 | RJ45 CONNECTOR – CO2 SENSOR |
4 | OVERRIDE TOGGLE SW = MAX SPEED |
Item | Destination |
---|---|
1 | 12/24 VOLT POSITIVE SUPPLY |
2 | CAN H OPTION |
3 | CAN L OPTION |
4 | SERIAL TRANSMIT RS232 |
5 | MOTOR CONTROL VOLTS OUT |
6 | ALARM + OUTPUT |
7 | TEMP SENSOR |
8 | NO CONNECTION |
9 | SERIAL RECEIVE RS232 |
10 | DOOR INPUT (+) |
11 | WINDOW INPUT (+) |
12 | 0V NEGATIVE GROUND |
Wiring Diagram GENERAL GUIDE
General Guide to Cabin Sealing, Testing, and Commissioning of BreatheSafe variable speed Pressurisation Units (Clean Cabin with HEPA vacuum)
1| Inspect the cabin and ensure all cover panels are in place and any
cabin pressure leaks are sealed with grommets, sealer, fit new door seals for
used equipment, etc
2| Sitting inside the cabin with the door open, turn on the ignition to
power up the unit.
3| The pressuriser fan should power up to full speed, and the monitor
should indicate 0 Pa pressure (Allow ± 2 pascals wind gusts).
4| With the ignition on, close all doors and windows. If the cabin is
adequately sealed, the monitor should indicate 50 Pa (Pascals), set pressure
or whichever pre-set has been chosen. (If not achieved, check for cabin
pressure leaks).
5| Once a cabin pressure of 50 Pa is confirmed. Go to the setting menu,
select “System Check.” The display will indicate “System Test – Max Fan” on
the screen while showing the maximum cabin pressure.
6| The MAX cabin pressure should be above 250 Pascals related to the
efficiency of cabin seals (Please note the minimum result for warranty
compliance is 250 pascals tested with a new 500000 HEPA filter). Therefore, a
cabin pressure result of 300 to 500 pascals is the ideal result.
7| If the above pressure is not achieved, leave the unit at full speed
and investigate external leaks outside the cabin: e.g., A/C outlets, drains,
window & door seals, locks & hinges, etc.
8| If necessary, with the ignition on, controller on ‘MAX FAN SPEED,’
A/C blower OFF & all doors & windows closed, set off a smoke emitter inside
the cabin (SWP attached).
9| Locate any air leaks around the cabin and re-test. If silicone
sealant or similar is used, allow it to dry before re-testing, as even
slamming the door could push the seal back out.
10| Continue the sealing and testing procedure as above until a
satisfactory outcome is achieved. Fill out the record below and attach photo
evidence of maximum pressure result and NANOZEN Real-time Dust Monitoring
result to register for warranty
SMOKE EMITTER CABIN PRESSURE LEAK TEST
- Do not handle until MSDS & all safety precautions have been read and understood. Use personal protective equipment as required.
Before use, carefully read the product label. Safe work practices are advised to avoid eye or skin contact and inhalation. Observe good personal hygiene, including washing hands before eating. Prohibit eating, drinking, and smoking in contaminated areas. Avoid inhalation. Mechanical extraction ventilation is recommended when the removal of atmospheric contaminants is required. Maintain dust / fume levels below the recommended exposure standard. For small amounts, absorb with sand, vermiculite or similar and dispose of at an approved landfill site.
WARNING
For Professional Use Only – keep out of reach of children.
Do not ignite near or around flammable materials.
Use only in well-ventilated areas, outdoors, and/or with proper respiratory
protection.
Persons with respiratory sensitivity should avoid exposure to any smoke.
Concentrated smoke may cause severe burns to the skin, eyes, or respiratory
system.
Improper use may result in sufficient inhalation of smoke to cause respiratory
tract irritation and lung damage.
Harmful if swallowed.
DANGER
Use only as directed. Do not handle until all safety precautions, including
Safety Data Sheet, have been read and understood.
The product contains hexachloroethane. Wear protective clothing. If exposed or
concerned, get medical advice. Store in a cool, dry, secure location. KEEP OUT
OF REACH OF CHILDREN. Dispose of contents/container per location regulations.
When used as directed, exposure should be limited and usually poses no hazard
because the hexachloroethane is consumed inside the tube as smoke is produced.
Directions: (Smoke Bomb)
1.| Ensure other workers in close proximity are informed of use. Place on a
non-combustible container, away from flammable materials.
2.| Place at Blower intake, or upwind of target area, or near centre of space.
3.| Orient “Smoke Issues Here” toward air stream, away from surfaces. Place
candle on a flame / heat resistance plate – if not it will melt into the
plastic surface.
4.| Ensure smoke will not create any hazard where it is anticipated to go.
5.| Ignite emitter inside the cabin using site approved device i.e., solder
torch or ‘lighter’ and conduct smoke test.
6.| Do not touch or hold smoke generator after ignition – item becomes very
hot & remains hot after use.
Smoke Emitter Cabin Pressure Leak Test
1.| The pressuriser system is switched on (TEST MODE).
2.| Hold the smoke emitter angled down.
3.| Ignite emitter using site approved ignitor i.e., solder torch or
‘lighter’.
4.| When the product ignites, remove the lighter.
5.| If the product flames up, blow out the flame.
6.| Place the emitter in a non-flammable container and place it inside the
cabin at floor level and close the door/windows.
7.| Observe smoke leaks to indicate worn-out or broken seal locations. Check
leakage points outside the cabin.
8.| Do not come into contact with or inhale smoke haze.
9.| Wait until the smoke haze completely disperses before re-entering the
cabin. Open door to allow sufficient ventilation of smoke prior to entering
cabin.
Link to MSDS: SMOKE GENERATOR TQ7621AT30S.pdf
Personal Protective Equipment (PPE)
| Safety glasses must be worn at all times.
| Sturdy footwear with rubber soles must be worn.
| Respiratory protection devices may be required.
| Gloves may be worn.
Pre-operational Safety Checks
| Locate and ensure you are familiar with all machine operations and
controls.
| Check work area and walkways to ensure no slip/trip hazards are
present.
****| Ensure the work area is clean and clear of any flammable material &
fire extinguish device is present.
Operational Safety Checks
| Ensure the machine is correctly isolated / immobilized.
| Ensure other persons do not inhale smoke haze.
****| Take care and do not place a lit emitter close to a flammable surface.
Ending Operations and Cleaning Up
****| Leave the work area in a safe, clean, and tidy state.
Potential Hazards
| Falls
| Fumes
| Fire
| May cause cancer
Exposure is highly unlikely when the product is used as directed. Direct
contact with the product does not occur.
Don’t
| Do not use if an open flame is forbidden.
| Never leave the emitter [cabin test] unattended.
*This SWP does not necessarily cover all possible hazards associated with this equipment and should be used in conjunction with other references. It is designed as a guide to be used to compliment training and as a reminder to users prior to equipment use.
CABIN SEALING TEST PROCEDURE
Cabin Sealing Efficiency Test Procedure
1| Start Engine – Pressuriser System is ON
2| Ensure all windows & door(s) are CLOSED correctly (no cabin pressure leaks)
NOTE: for a new cabin with effective seals, you may need to open a window
slightly before closing the door to bleed the static cabin air pressure
outwards. Once door is fully closed then close windows to begin testing.
3| Enter the Settings menu via the touch screen button.
4| Select and press the System Check button to go to System Test – Max Fan.
5| Record / photograph the maximum cabin pressure achieved.
COMMISSIONING PROCEDURES – CABIN PRESSURISER
Commissioning Procedures
Follow each step of the installation guide that was supplied with the
BreatheSafe kit.
Cabin sealing is an integral part of RS20 & ISO 23875; you must ensure that
cabin seals are adequate for maintaining positive pressure.
In addition, the site (end- user) must have the correct procedure(s) for
servicing OPERATOR enclosure seals in a proactive manner rather than reactive.
Items such as door and window seals must be in good working order or new seals
FITTED before the BreatheSafe system installation.
Touch-screen cabin pressure display/controller Part# 200027:
*System Check Function: enter the Settings menu option and select “System Check – Set Max.” The minimum BreatheSafe requirement for cabin sealing efficiency is 250 pascals; if this result is not met, it is essential to re-examine and find pressure leaks of the enclosure and apply new sealing measures.
Submission for commissioning procedure as per the diagram below: The commissioning images
required are:
- ID plate / Machine Serial Number / Asset Number or Call Sign
- INPRESS TL Pressuriser location
- HEPA Return Air Filter Location Option: Powered Return Air Filter
- Cabin Pressure Display Location – Including the “System Check” maximum cabin pressure result with motor output capacity %
Fill in the BreatheSafe Service Tag with the following details:
- Machine Serial Number and Installers details
- Date installed and System Check result (max cabin pressure)
- The set cabin pressure with actual pressure and motor percentage output
- Verify the 250-pascal threshold was achieved = pass OR not achieved = fail**
Please upload machine and installation details in conjunction with the required images. A Commissioning Certificate will be sent to the email address you nominate. **Extended warranty for (RS20 & ISO 23875) BreatheSafe Systems is only applicable to operator enclosures meeting this requirement.
BREATHESAFE SYSTEM TROUBLE SHOOTING GUIDE *TOUCH CONTROL
FAULT| POSSIBLE CAUSE| SOLUTION
*ERR error code*| Poor sensor connection| Remove & refit pod
connection cable
Corrupted coding| Access factory setup – default reset – pin 6759
Check filter alarm| Service hour timeout| Access Check
Runtime menu – reset hours via 7597 code
Temperature / CO2 error| Sensor not connected| Fit sensor or
disable via site access CO2 & or temperature menu
Pressuriser running at full speed/noisy| Filter blocked|
Service filter
Door or window open| Ensure doors & windows securely shut
Cabin sealing capacity not adequate| Perform pressure test procedure & seal
leak points as required
Sense pipe blocked| Ensure clear & not bent
Internal sensor damaged| Replace controller
**No need to change setpoint
Filter blocking quickly| Defective cabin sealing| Perform
pressure test procedure & seal leak points as required
Pre-cleaner failed| Check operation & replace if necessary
Display blank| Poor power supply| Check mains supply fuse & correct
voltage
Check voltage & 20AMP supply/connections at pin 1 @ monitor
Check earth continuity at controller pin 12
Failed controller| Replace monitor
Controller showing 0.0 pressure| Fresh air filter blocked|
Check filter condition & replace if required.
Low pressure alarm| Door or window open| Ensure doors & windows
securely shut
Cabin sealing capacity not adequate| Perform pressure test procedure & rectify
cab sealing
Pressuriser not operating| Ensure correct voltage 12v or 24v to pressuriser
motor pin A
Check 1.6V – 10V present at motor Pin C
Check 20A Supply fuse
Check earth continuity Pin B
Pressure sense tube blocked| Unplug at monitor & ensure clear flow to external
of cabin
Ensure pressure tube fitted correct port A
**No need to change setpoint
Pressuriser not working| Poor power supply| Check 20A mains fuse
& correct voltage
Ensure adequate wire size & no voltage drop
Ensure correct voltage 12v or 24v to pressuriser motor pin A
Check 1.6V – 10V present at motor Pin C
Poor earth| Check earth continuity @ motor pin B
Motor faulty| Replace TL4M
Access Codes:| Site Access: 7597| Factory
Setup: 6759**
USER SETTINGS INSTRUCTIONS
User Settings Instructions
ENTER SET UP MODE
Start-Up Screen > Main Screen > Settings Button > Settings Screen > Site
Access Button > Insert Pin > Site Menu
To enter the Setup mode, press the SETTING button.
Then enter SITE ACCESS MENU. Type in 4-number pin and press ENTER. SET UP
PARAMETERS
Placing the BreatheSafe 200027 unit into Setup mode allows the adjustment of the following parameters:
- Time (hours/minutes/seconds)
- Date (day/month/year)
- Pressure alarm setpoint
- Preferred cabin pressure
- Alarm delay/ intervals of alarm
- Calibration and system settings
- Resetting of the data logging
- Service reminders interval gap
- Reset current runtime between services
- CO2 settings and alarms
PRESSURE SETPOINT
The pressure setpoint changes the pressure that the cabin will be maintained.
INPRESS TS maintains the pre-set pressure within the cabin compared to
outside.
Enter Setup mode and select ADJUST SETPOINT button. Then, use the onscreen UP
and DOWN buttons to change the corresponding fields. PRESSURE ALARM SETTING
The mining industry benchmark for cabin pressure is 50 pascals and low-
pressure is set at 20 pascals.
After a delay the alarm will activate if cabin pressure remains below the pre-
set value. Enter Setup mode and select ADJUST SETPOINT button. Then, use the
onscreen UP and DOWN buttons to change the corresponding fields. SERVICE INTERVAL
Use the onscreen UP and DOWN buttons to change the service interval setpoint.
To reset the current runtime to zero, press the RESET CURRENT RUNTIME button
and enter the site access pin. DATE & TIME SETTINGS
Change the recorded date displayed and measured by the INPRESS TS. PRESSURE ALARM BUZZER
SETTING
To disable the buzzer, toggle through to the ENABLED and DISABLED buttons.
CALIBRATE ZERO SENSOR
Over long runtime, the 200027 may need recalibration. This screen allows
the sensor to be recalibrated if more than 5 Pascals are out. To recalibrate,
open windows and doors, turn off air conditioning, and any other device that
may alter cabin pressure.
Then, press the AUTO ZERO SENSOR button and leave the cabin while measuring.
This process will reset the Zero Pressure. CO2 MODULE ENABLE/DISABLE
Enable or disable to CO2 module used for measuring CO2 levels within the
cabin. CO2 SETTINGS
CO2 PRIMARY ALARM POINT
The first alarm will sound when CO2 levels inside the enclosure reach this
point. CO2 ALARM DELAY
After CO2 (concentration in ppm) within the cabin reaches the 1000 ppm
setpoint, the alarm will sound after this designated amount of time. The Alarm
Delay adjusts the time between the INPRESS TS measuring CO2 concentration and
sounding the alarm. Use the onscreen ADJUST buttons to change the
corresponding fields. For example, press to toggle through Disabled / 1 – 10
minutes. CO2 SETTINGS
CO2 CRITICAL ALARM MUTE RESET
The critical alarm is set at 2500 PPM and cannot be changed. The mute delay,
however, can be configured.
DATA DOWNLOAD
Data Download – Setting up RS232 Connection
1 | Plug the RS232/USB adaptor into a free USB port on your computer |
---|---|
2 | Open up TeraTerm software. |
** (TeraTerm is an open-source software tool and easily accessible via
online search)
3**| Use the following settings in TeraTerm: Serial and choose the correct
port connection
Hint:
Click on the COMxx Port with the “USB serial Port” connection from the drop-
down menu.
Example: COM 21
This connection may be different on your computer.
4 | Click OK once the correct communication port has been identified. |
---|---|
5 | Go to SETUP and click on Serial Port. |
6 | Change the COM ports to the following configuration: Baud |
Rate: 57600 Data: 8 bit Parity: EVEN
Stop: 2 bit
Flow Control: NONE
7| If required, you may choose to save the COM port settings. Go to
Settings and clock save the setup.
Hint: From the drop-down menu, click on the Save Setup.
Name the file and save it.
---|---
8| The next time a download is required, you may restore the setup, and
the required COM PORT settings will be loaded, ready to download the data file
from the 200027 unit.
9 | From the drop-down menu, click on the Save setup. |
---|---|
10 | Click Restore setup. |
11 | Choose the file name you have already saved. |
12 | From the drop-down menu, click on the Edit menu function. |
---|---|
13 | Press “Select All”. |
14 | Select “Copy table”. |
15 | Open a blank excel document and click on the page. Then, right-click |
to paste the copied table.
16| Fields are: Date, time, motor (volts) output, cabin pressure (Pa),
cabin pressure pre-set (Pa), low cabin pressure alarm (Pa).
Excel Data Instructions – Unformatted
Open an Excel sheet and select the first cell A-1. Next, press and hold
down the CTRL button on your keyboard and then press the letter V on the
keyboard.
This procedure will paste the copied data onto that Excel sheet. Once that
data has been pasted onto the Excel sheet, click on ‘DATA’ on the pull-down
menu, followed by ‘Text to Columns’. Next, select ‘Delimited’ on the newly
opened window and click on Next.
Only select the ‘Comma’ button in the next window and then click ‘Finish’.
Then, the Excel fields will update such that each piece of data is placed in
the correct columns.
The data is now ready for archiving.
Data Logging Formats
BU No: xxxxxx (the device number unique to each unit and used for
identification – format = 000000)
Time: [09:25] Date: [25/07/12] Pressure: 32 (Pascals) as an example.
Alarm Type
0| = No alarm
1| = Low-pressure alarm
2| = Window open
3| = Door open
INPRESS TL WARRANTY
Express Warranty
All BreatheSafe products carry a warranty against defects in materials or
workmanship, provided the defects are not from factors outside of
BreatheSafe’s control (including neglect, lack of maintenance, improper
installation or operation, unauthorized servicing repair, etc.). BreatheSafe
will replace goods defected in material or workmanship at our Queensland
factory or designated branch*. All parts deemed as failed or faulty must be
returned to BreatheSafe for evaluation unless otherwise stated in writing.
Note- Systems must be installed and commissioned as per BreatheSafe
installation and commissioning instructions. Once commissioned, the online
commissioning sheet must be filled in, extending the components warranty as
below. In addition, the system must be serviced and maintained correctly and
by trained and qualified personnel. This requisite includes BreatheSafe
technicians, qualified automotive air-conditioning technicians, or qualified
auto electricians.
Warranty period – Standard
- 1 year or 10,000 hours (whichever occurs first).
- Controllers – 1 year no extended warranty option.
- Warranty Period Extension when commissioning documents are registered online within 28 days of installation
- Extended warranty** only offered if commissioning maximum pressure test reaches at least 250Pa.
- Brushless motor fixed speed two years, or 10,000 hours (whichever occurs first).
- Variable speed brushless motor 15,000 hours, or 3 years** (whichever occurs first).
Must be supplied with a variable speed pressure controller, data download
required for 3-year warranty option. Link to online Commissioning and Extended
Warranty Registration form https://www.breathe-safe.com.au/commission/
What is not covered under Express Warranty?
- Failures are due to incorrect application.
- Damage resulting from neglect, misuse, lack of maintenance, improper installation, or operation, inappropriate or abnormal use, accidental or unauthorized servicing repair.
- Failures are due to parts not being sold or approved by BreatheSafe.
- Failures arising from any other cause that is not directly related to a defect in material or workmanship.
This Express Warranty is VOID if the product is altered, modified, or used in
the manner it was not designed for, also including unauthorized repairs, or
using maintenance and repair parts other than those supplied by BreatheSafe.
BreatheSafe responsibilities
If there is a defect in material or workmanship not caused by the excluded
failures during the warranty period, BreatheSafe will either replace the
defective goods at our Queensland factory, or designated branch.
Alternatively, BreatheSafe may elect to provide new replacement parts,
BreatheSafe approved repair parts or assembled components needed to repair the
defect. BreatheSafe reserves the right to provide a refund of the purchase
price in lieu of replacement or repair at BreatheSafe’s discretion. The
replacement or repaired product will be sent to you freight prepaid by the
customer or made available for pick-up on site.
Users Responsibilities
The customer should ensure that the system is maintained according to
BreatheSafe service requirements and only authorized parts must be used to
service and maintain BreatheSafe systems. In the event of a suspected warranty
claim, BreatheSafe should be contacted in the first instance to arrange the
repair or to assist with diagnosis. Claims should be made within one week of
the repair.
After contacting BreatheSafe, you may be required to deliver or send the parts
to BreatheSafe’s Queensland factory or designated branch. Link to online
Warranty claim form https://www.breathe-safe.com.au/warranty/
Exclusion and Limitations on Damages and Remedies
This warranty is provided in lieu of all other warranties, written or oral,
whether expressed by affirmation, promise, description, drawing, model, or
sample. To the extent allowed by law, all warranties other than this warranty,
whether express or implied, including implied warranties of fitness for a
particular purpose, are disclaimed. The maximum liability of BreatheSafe under
this warranty shall not exceed the original purchase price of the product.
Interference with the equipment by or abuse, or by operating the equipment at
ambient temperatures or with electrical power characteristics outside the
ranges indicated in our specification shall be excluded from this warranty, as
shall consequential damages.
Excluded from any express warranty are costs incurred in relation to service
outside our factory our designated service branch, including traveling time,
waiting time, transport costs, mechanical and overtime payments required.
As per Australian Consumer Law: You are entitled to choose a refund or
replacement for major failures with goods. If a failure with the goods or
service does not amount to a major failure, you are entitled to have the
failure rectified in a reasonable time. If this is not done, you are entitled
to a refund for the goods and to cancel the contract for the service and
obtain a refund of any unused portion. You are also entitled to be compensated
for any other reasonably foreseeable loss or damage from a failure in the
goods or service.
*This express warranty gives you specific legal rights, and you may also have other rights that vary from country to country.
References
- BreatheSafe - Intelligent HEPA H14 Cabin Air Filtration
- Home - Safe Software
- BreatheSafe - Intelligent HEPA H14 Cabin Air Filtration
- Commissioning - BreatheSafe
- Commissioning - BreatheSafe
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>