CHAMPION 200991 Dual Fuel Inverter Generator User Guide

June 12, 2024
Champion

CHAMPION logo

CHAMPION 200991 Dual Fuel Inverter Generator

CHAMPION 200991 Dual Fuel Inverter Generator

DANGER

MOVE GENERATOR OUTDOORS
Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
ONLY use OUTSIDE and far away from windows, doors, and vents.

WARNING
Read the ENTIRE operator’s manual to become familiar with the features of this product before operation. This QuickStart Guide IS NOT a substitute for the Operator’s Manual.
Failure to operate the product correctly could result in damage to the product, personal property or cause serious injury or death.

NOTICE
Keep all objects at least 5 feet (1.5 m) from generator. Heat from the muffler and exhaust gas can ignite combustible materials.

PARTS INCLUDED

CHAMPION 200991 Dual Fuel Inverter Generator 1

SET UP

Shipping Support. Assembly > Remove Shipping Support Hardware.

CHAMPION 200991 Dual Fuel Inverter Generator 2

Connect the battery. Assembly > Connect the Battery.
Push two halves of battery connector together tightly.

CHAMPION 200991 Dual Fuel Inverter Generator 3

Add oil. Assembly > Add Engine Oil.
Recommended: 10W-30, up to 16.9 fl. oz. (500 ml) DO NOT overfill.

CHAMPION 200991 Dual Fuel Inverter Generator 4

Move the generator outdoors.
ONLY USE OUTSIDE AND FAR AWAY FROM WINDOWS, DOORS, AND VENTS.

CHAMPION 200991 Dual Fuel Inverter Generator 5

Add fuel – Gasoline or Propane (LPG)
Assembly > Add Fuel

CHAMPION 200991 Dual Fuel Inverter Generator 6

DO NOT plug in any electrical devices.
NEVER START OR STOP THE GENERATOR WITH ELECTRICAL DEVICES CONNECTED OR TURNED ON!

CHAMPION 200991 Dual Fuel Inverter Generator 7

Starting the Engine: Gasoline

Electric Start

  1. Turn the EZ Start Dial to the “CHOKE” position.
  2. Press and hold ignition switch on the EZ Start Dial.
  3. Turn the EZ Start Dial to the “RUN” position.

CHAMPION 200991 Dual Fuel Inverter Generator 8

Manual Start

  1. Turn the EZ Start Dial to the “CHOKE” position.
  2. Pull the recoil to start the engine.
  3. Turn the EZ Start Dial to the “RUN” position.

CHAMPION 200991 Dual Fuel Inverter Generator 9

START UP

Starting the Engine: Propane (LPG)
Electric Start

  1. Open the propane tank valve.
  2. Turn the EZ Start Dial to the “CHOKE” position.
  3. Press and hold the ignition switch on the EZ Start Dial for 2-3 seconds.
  4. Turn the EZ Start Dial to the “RUN” position.
  5. Press and hold ignition switch on the EZ Start Dial.

CHAMPION 200991 Dual Fuel Inverter Generator 10

Manual Start

  1. Open the propane tank valve.
  2. Turn the EZ Start Dial to the “CHOKE” position.
  3. Pull the recoil 2-3 times to prime the engine.
  4. Turn the EZ Start Dial to the “RUN” position.
  5. Pull the recoil to start the engine.

CHAMPION 200991 Dual Fuel Inverter Generator 11

Plug in. Operation > Connecting Electrical Loads.

CHAMPIONPOWEREQUIPMENT.COM

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Champion User Manuals

Related Manuals