ams AS5601 Standard Board User Manual

June 12, 2024
ams

ams AS5601 Standard Board

Product Information

The AS5601 Standard Board is an evaluation kit that allows for easy and fast evaluation of the AS5601 rotary magnetic position sensor. It can be used in a lab setting or together with an existing system. The kit includes a fully assembled adapter board with the AS5601 position sensor and necessary external components. All relevant signals are available on a dual-row 2.54mm 4-pin header footprint, making it easy to wire to an existing application. The kit also includes a USB I&P Box, which is a programming and demonstration tool for configuring the device. Additionally, a small magnet holder and a knob with a magnet attached are provided to demonstrate the functionality of the AS5601.

Kit Content

The kit includes the following items:

No. Item
1 USB I&P Box
2 AS5601-SO_EK_AB (Adapterboard)
3 RMH05-DK-XX-1.0 (Rotary Magnet Holder with Knob)

Product Usage Instructions

Getting Started

To get started with the AS5601 Standard Board, follow these steps:

  1. Install the AS560X Demo Software:

    • The software can be found on the USB drive that comes with the
      USB I&P Box or it can be downloaded from the website.

    • After installation, run the software.

  2. Short J1 on the adapter board to set up the 3.3V mode. Assemble the Hardware Setup:
    (Figure 1: Setup Instructions)

Note: For more detailed instructions, please refer to the specific manual available on the amsAG website.

Introduction

The evaluation kit allows an easy and fast evaluation of the AS5601 rotary magnetic position sensor in the lab or together with an existing system. It includes all required material to evaluate the product features.
The small adapter board is fully assembled with AS5601 position sensor and its necessary external components. All relevant signals are available on a dual- row 2.54mm 4-pin header footprint and can be easily wired to an existing application.
The USB I&P Box is an easy-to-use programming and demonstration tool. It can be used to configure the device and to program a configuration.
A small magnet holder and a knob with a magnet attached on its shaft is enclosed to show the functionality of the AS5601.
The AS5601 is an easy-to-program magnetic rotary position sensor with incremental quadrature (A/B) and 12-bit digital outputs (I2C). Additionally, the PUSH output indicates fast airgap changes between the AS5601 and magnet which can be used to implement a contactless pushbutton function in which the knob can be pressed to move the magnet toward the AS5601. Based on planar Hall technology, this device measures the orthogonal component of the flux density (Bz) from an external magnet while rejecting stray magnetic fields.
The I²C interface is used for configuration and user programming of non- volatile parameters in the AS5601.

Kit Content

This kit contains following material listed in Table 1. Additional material can be found on our webpage.

Table 1: Kit Content

ams-AS5601-Standard-Board-5

For a detailed description of each item please refer to the specific manual. All manuals are available online on the amsAG website.

Getting Started
The AS5601 adapter board is ideal for rapid setup of a contactless potentiometer because it includes all necessary tools to operate and configure the AS5601.
This first steps describes how to connect and use the USB I&P Box together with the AS560X

Demo Software and the adapter board.
1st Install the AS560X Demo Software
The Software is located on the USB drive that comes with the USB I&P Box or it can be downloaded from our webpage. After installation run the software.

2nd Assemble the Hardware Setup
Follow the Instructions shown below in Figure 1 to set up the kit.

Figure 1: Setup Instructions

  • A. Short J1 on the adapterboard to set-up the 3.3V mode
  • B. Connect the USB I&P Box with the AS5601-SO_EK_AB using the 10-way cable
  • C. Place the RMH05 over the adapterboard
  • D. Connect the USB I&P Box using the USB cable to Computer.
    The USB device is detected in Windows and by the AS560X
    Demo Software. The setup is ready for demonstration.

ams-AS5601-Standard-Board-1

Note:

  • The AB signals of the quadrature incremental interface cannot be detected using the initial version of the USB I&P Box.
  • It might be necessary to perform a firmware update on the USB I&P Box if a wrong firmware was detected. In this case, the user will be prompted to allow an automatic firmware upgrade.

Start using the software

Following parts of the software are used to perform a configuration and to read-out the AS5601.
Refer to Figure 2 for reference. Read the software user manual for details.

  • A. Perform the desired configuration

  • B. Perform the required grid and grid offset programming.
    Use the wizard function for reference.

  • C. Verify the results

Figure 2: General Software Instructions

ams-AS5601-Standard-Board-2

Ordering & Contact Information

ams-AS5601-Standard-Board-3

Buy our products or get free samples online at: www.ams.com/ICdirect
Technical Support is available at: www.ams.com/Technical- Support
Provide feedback about this document at: www.ams.com/Document- Feedback
For further information and requests, e-mail us at: ams_sales@ams.com
For sales offices, distributors and representatives, please visit: www.ams.com/contact

Headquarters
ams AG
Tobelbaderstrasse 30
8141 Unterpremstaetten
Austria, Europe
Tel: +43 (0) 3136 500 0
Website: www.ams.com

Copyrights & Disclaimer
Copyright ams AG, Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria- Europe. TrademarksRegistered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner.
Demo Kits, Evaluation Kits and Reference Designs are provided to recipient on an “as is” basis for demonstration and evaluation purposes only and are not considered to be finished end-products intended and fit for general consumer use, commercial applications and applications with special requirements such as but not limited to medical equipment or automotive applications. Demo Kits, Evaluation Kits and Reference Designs have not been tested for compliance with electromagnetic compatibility (EMC) standards and directives, unless otherwise specified. Demo Kits, Evaluation Kits and Reference Designs shall be used by qualified personnel only. ams AG reserves the right to change the functionality and price of Demo Kits, Evaluation Kits and Reference Designs at any time and without notice.
Any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. Any claims and demands and any direct, indirect, incidental, special, exemplary or consequential damages arising from the inadequacy of the provided Demo Kits, Evaluation Kits and Reference Designs or incurred losses of any kind (e.g. loss of use, data or profits or business interruption however caused) as a consequence of their use are excluded.
ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect,special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services.

Revision Information

Initial version 1-00

ams-AS5601-Standard-Board-4

Note: Page numbers for the previous version may differ from page numbers in the current revision.

ams Eval Kit Manual
[v1-00] 2014-Jul-02

Downloaded from Arrow.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals