ROLBIT C124W Under Floor Thermostat Instructions

June 12, 2024
ROLBIT

ROLBIT C124W Under Floor Thermostat

DIMENSION

ROLBIT-C124W-Under-Floor-Thermostat-FIG-1

Product Information

The C124W Under Floor Thermostat is a DIN rail mount thermostat that operates directly from 230 volts. It is designed to control and supply power to underfloor heating systems. The thermostat features a temperature setting knob, LED indicators for power ON and load operation, and optional underfloor temperature sensor protection. It comes with remote temperature sensor and screw terminal connectors. The thermostat is designed to be mounted inside an electrical cabinet as a standard DIN rail box. It is made of non-flammable plastic and has the following dimensions:

  • Nominal Voltage: 230 volts
  • Temperature Accuracy: 85.6
  • Differential Output Rating: HEATER
  • Relative Humidity: N
  • Thermostat Dimensions : 123mm x 45mm x 34.8mm

Product Usage Instructions

  1. Ensure all wiring is done according to the local electrical codes.
  2. Mount the C124W Under Floor Thermostat inside an electrical cabinet using the provided DIN rail box.
  3. Connect the thermostat to the power supply using the L~ and N terminals.
  4. Connect the underfloor heating system to the thermostat using the OUT and IN terminals.
  5. If underfloor temperature sensor protection is required, connect the optional sensor to the thermostat using the IN and PE terminals.
  6. Use the temperature setting knob to adjust the desired temperature for the underfloor heating system.
  7. The LED indicator for power ON will illuminate when the thermostat is powered.
  8. The LED indicator for load operation will illuminate when the underfloor heating system is in operation.
  9. For thermostats with a limiting sensor, do not remove the resistor at the external sensor terminals unless the underfloor temperature protection feature is not needed.

For more information or support, please contact Rolbit
Thermostat:

  • UNDER FLOOR DIN RAIL MOUNT
  • OPERATES DIRECT FROM 230 VOLTS
  • REMOTE ROOM AND FLOOR SENSORS
  • C124W Control and supply power to underfloor systems. Temperature setting with a knob.
  • LED indicator for power ON.
  • LED indicator for load operation.
  • Optional underfloor temperature sensor protection. Remote temperature sensor.
  • Screw terminal connectors.
  • Mounts inside electrical cabinet as standard DIN rail box.

SPECIFICATIONS

  • Nominal Voltage: 230 VAC (50-60 HZ)
  • Temperature accuracy: ±1ºC (±2 ºF)
  • Differential: 1 ºC (2 ºF)
  • Output rating: 16 Amps (resistive)
  • Relative Humidity: 10%-90% RH
  • Non flammable plastic: ABS – V0 94
  • Thermostat Dimensions: 3 4.8×57.4×85.6 mm

Model

C124W-RLS- Range 5-30°C, Limits 24-29°C

| Part No

C124W-RLS-A-2429-16

---|---
C124W-RSC- Range 5-50°C| C124W-UFS –C-16
External sensor – 3 Meters| 3SE1030010100

INSTALLATION

  • The C124W thermostat is produced in few part numbers to match the application needed.
  • Please check the below part number and match with the unit in your hand to be sure it is the type you need for your application.

INSTALLATION REQUIRMENT
All wiring must be made according to the local electrical codes.

MOST POPULAR ITEMS

  • C124W-RLS-A-2429-16 – Set Point Range 5 / 30°C, Limit sensor 29°C Off – 24 On with 0.5 amps load. Supplied with one external sensor.
    Note: If the Limiting sensor should be used, order additional sensor Part number 3SE1030010100.

  • C124W-UFS- Set Point Range 5-50°C with 0.5 amps load.

OPTIONS
Set Point Range – (Working Temp. Range)

  • A – 5 / 30°C Scale.
  • B – 5 / 40°C Scale.
  • C – 5 / 50°C Scale.

LIMITS – UNDER FLOOR TEMPERATURE CUT-OUT

  • 2429 – Limiting Range at 29°C Off at 24°C On.
  • 3040 – Limiting Range at 40°C Off at 30°C On.
  • 4050 – Limiting Range at 50°C Off at 40°C On.

OPERATION VOLTAGE

  • Standard – 230 VAC 50-60 HZ.
  • Optional – 120 VAC 50-60 HZ.

RESISTIVE LOAD

  • Standard – 0.5 Amps.

EXTERNAL SENSOR

  • Standard – 3 meters cable. Part number 3SE1030010100
  • Optional – 6 meters cable. Part number 3SE1060010100

NOTE: Thermostats with limiting sensor to protect the under floor heating. In case this feature is not needed, do not remove the resistor at the ext. sensor terminals.