ABB AF-S-190-B-30-RT Contactors-Auxiliary Contacts Instructions
- June 12, 2024
- ABB
Table of Contents
ABB AF-S-190-B-30-RT Contactors-Auxiliary Contacts
Product Information
This product is a range of contactors and auxiliary contacts manufactured by ABB. The specific models included in this range are AF(S)190(B)-30(RT), AF(S)205(B)-30(RT), AF(S)265(B)-30(RT), AF(S)305(B)-30(RT), AF(S)370(B)-30(RT), AF265N5-30, AF190(B)-40(RT), AF205(B)-40(RT), AF265(B)-40(RT), AF305(B)-40(RT), AF370(B)-40(RT), CAL19-11(RT), CAL19-11B(RT), CEL19-10(RT), CEL19-01(RT).
Features
- Contactor and auxiliary contact combination
- Available in various models and configurations
- Suitable for use in PLC systems
- Designed for safe and reliable operation
Specifications
- Max voltage: Up to 600V AC or 250V DC
- Max current: Up to 10A (AC) or 2.5A (DC)
- Make/break current: Up to 60A/6A (AC) or 0.55A/0.27A (DC)
Product Usage Instructions
- Before performing any work on the device, ensure that all power sources are disconnected and isolated.
- The installation should be carried out by a qualified installer only.
- Refer to the installation instructions specific to your model for proper wiring and connection details.
- For models AF(S)265, AF(S)305, and AF(S)370, use pressure terminal connectors such as ABB ATK300, ABB ATK300/2, T&B RB770300, T&B RB770302, or listed (ZMVV) wire connectors and soldering lugs. Crimp the wire connectors using a special factory crimp tool. Ensure that the enclosure used has a minimum dimension of 36 by 30 by 12 inches.
- For models AF(S)190-30, AF(S)205-30, AF(S)265-30, AF(S)305-30, AF(S)370-30, ensure that the circuit used is capable of delivering not more than the maximum symmetrical amperes at the maximum voltage shown in SOC.
SAFETY INSTRUCTIONS
AF(S)190(B)-30(RT), AF(S)205(B)-30(RT), AF(S)265(B)-30(RT), AF(S)305(B)-30(RT), AF(S)370(B)-30(RT), AF265N5-30, AF190(B)-40(RT), AF205(B)-40(RT), AF265(B)-40(RT), AF305(B)-40(RT), AF370(B)-40(RT), CAL19-11(RT), CAL19-11B(RT), CEL19-10(RT), CEL19-01(RT)
Contactors/Auxiliary Contacts
Warning: Hazardous voltage Refer to
installation instructions. Disconnect and lad out power before working on this
device. Attention! Installation by person with electrotechnical expertise
only.
INSTALL ATION INSTRUCTIONS
AF(S)190(B)-30(RT), AF(S)205(B)-30(RT), AF(S)265(B)-30(RT), AF(S)305(B)-30(RT), AF(S)370(B)-30(RT), AF265N5-30, AF190(B)-40(RT), AF205(B)-40(RT), AF265(B)-40(RT), AF305(B)-40(RT), AF370(B)-40(RT), CAL19-11(RT), CAL19-11B(RT), CEL19-10(RT), CEL19-01(RT)
| | | | | | | | |
---|---|---|---|---|---|---|---|---|---
|
- M 3,5
- 1 Nm –
- 9 Ib.in
| ø 5,5| Pz 2|
- 1 x 1 … 4 mm²
- 2 x 1 … 4 mm²
- 1 x AWG 18 … 14
- 2 x AWG 18 … 14
|
- 1 x 0,75 … 2,5 mm²
- 2 x 0,75 … 2,5 mm²
- 1 x AWG 18 .. 14
- 2 x AWG 18 .. 14
|
- 1 x 0,75 … 2,5 mm²
- 2 x 0,75 … 2,5 mm²
|
- 1 x 0,75 … 2,5mm²
- 2 x 0,75 … 2,5mm²
|
- I > 3,5 mm
- L < 8 mm
| 9 mm
|
- M 3,5
- 0.3 Nm –
- 2.6 Ib.in
| ø 3,5| |
- 1 x 0.2…. 1.5 mm²
- 2 x 0.2… 1 mm²
- 1 x AWG 24…. 12
- 2 x AWG 24… 12
|
- 1 x 0,2 … 2,5 mm²
- 2 x 0,2 … 1,5 mm²
- 1 x AWG 24 … 12
- 2 x AWG 24 … 12
|
- 1 x 0,25 … 2,5 mm²
- 2 x 0,25 … 1 mm²
|
- 1 x 0,25 … 2,5 mm²
- 2 x 0,5 … 1,5 mm²
| | 6 mm
- According to UL60947-4-1 Use wire Cu 75°C only.
- AF(S)190, AF(S)205:
- Use Pressure Terminal Connectors ABB ATK185, T&B RB770185 or use Listed (ZMVV) Wire Connectors and Soldering Lugs.
- Wire connectors (Cable pole-shoe) crimped with special factory crimp tool.
- Enclosure with min. dimension 24 by 20 by 10 inches should be used.
- AF(S)265, AF(S)305, AF(S)370: Use Pressure Terminal Connectors ABB ATK300, ABB ATK300/2, T&B RB770300, T&B RB770302 or use Listed (ZMVV) Wire Connectors and Soldering Lugs.
- Wire connectors (Cable pole-shoe) crimped with special factory crimp tool.
- Enclosure with min. dimension 36 by 30 by 12 inches should be used.
- AF(S)190-30, AF(S)205-30, AF(S)265-30, AF(S)305-30, AF(S)370-30:
- Suitable for use on a circuit capable of delivering not more than the max. symmetrical amperes at the max. voltage, shown in SOC.
CAL19 Pilot duty acc. to UL60947-4-1
Rating code | Terminal Continuous Current | Voltage | Make/Break Current |
---|---|---|---|
A 600 | 10A |
- 120V AC
- 240V AC
- 480V AC
- 600V AC
|
- 60 A / 6 A
- 30 A / 3 A
- 15 A / 1.5 A
- 12 A / 1.2 A
Q 300| 2.5A| 125V DC| 0.55 A
| | 250V DC| 0.27 A
Definite Purpose magnetic motor controller. Breaking all lines.
Max 600V AC, 50/60 Hz:
TYPE| Herm. ref. comp, AC-8a| Ballast, AC-5a/ Resistance air heating| Elevator
duty
---|---|---|---
FLA| LRA
AF(S)190| 200| 1400| 250| 77
AF(S)205| 250| 1500| 300| 99
AF(S)265| 300| 2100| 400| 125
AF(S)305| 350| 2450| 450| 144
AF(S)370| 520| 3120| 520| 156
AF190-40| 200| 1400| 250| –
AF205-40| 250| 1500| 300| –
AF265-40| 300| 2100| 400| –
AF305-40| 350| 2450| 450| –
AF370-40| 520| 3120| 520| –
Notice: This product has been designed for environment A. Use of this product in environment B may cause unwanted electromagnetic disturbances in which case the user may be required to take adequate mitigation measures.
General
AF-contactors are fitted with an electronic interface.
-
Code-11…-14, optimized for wide voltage range and stability
Operation is done, as with conventional contactors, by applying and removing supply voltage on A1 and A2. Closing when 80% above the lower nominal voltage limit, opening when below 55% of the lower nominal voltage limit, which is indicated in the functional diagram. -
Code-42 and -43, optimized for short operation times
Operation is done, as with conventional contactors, by applying and removing supply voltage on A1 and A2. Closing when 80% above the lower nominal voltage limit, opening when below 20% of the upper nominal voltage limit. Undefined function between the limits.
General for 4-pole
AF-contactors are fitted with an electronic interface. For a give coil, this
interface allows the contactor to accept a very wide voltage range. Operation
can be done as with convectional contactors by applying and removing voltage
on A1 and A2 (code 11-14). The function limits for the supply voltage (closing
at 85% and opening at 55%), which is indicated in the diagram by high and low
voltage.
Code-31…-34 built-in PLC interface
- Operation is controlled by separate logic control signals from for instance a PLC. Use of logic control requires a steady supply voltage on A1 and A2 within the rated voltage range, as described for code-11…-14- The function of the logic control signal will no longer be guaranteed when the supply voltage on A1 and A2 is removed.
- The logic control signals are operated with 24V d.c. There are two control signals (ON and OFF_N) and a common reference (COM). For the control signals, the function is guaranteed from 15V d.c. (6mA) to 33V d.c. (20mA).
- The contactor is closed by a control signal ON and opened by removal of control signal from OFF_N. The functions are described in the diagram below. “1” means 24V d.c. between the control signal and COM. “0” means no voltage between the control signal and COM. Minimum control signal pulse length for opening and closing is 10ms. To connect the PLC interface use cable dimension of max 1.5mm²
When used with switches the wiring can be done according to diagram above.
ABB Electrification Sweden AB
SE-721 61 Vasteras
Sweden
Further information Revision
W
Revision date
2023-03-01
Document number
1SFC100008M0201
© Copyright 2023 ABB.
All rights reserved.
Specifications subject to change without notice.
abb.com/lowvoltage