LANCOM UF-60 Firewall Rack Mount Instructions

June 12, 2024
LANCOM

Firewall Rack Mount UF-60
Mounting instructions

UF-60 Firewall Rack Mount

LANCOM UF 60 Firewall Rack Mount

Begin mounting the power supply holding plate by screwing it to the right mounting bracket using 4 of the 6 screws with washers provided.
Then remove the 4 housing screws on the right side of the device and align the mounting bracket with the screwed-on power supply mounting plate on the right side of the device housing so that you can fasten it to the device with 4 of the 8 longer countersunk screws supplied.
Next, attach the mounting bracket to the left side of the unit after removing the original screws. Use the remaining 4 longer countersunk screws for this purpose.
Then, as shown in the photo, place the power supply on its mounting plate.
Place the power supply holder with the mounting area of the retaining plate as shown, so that both mounting holes are aligned, and hand-tighten it to the power supply retaining plate using the two remaining screws with washers provided, so that the power supply holder can still be moved.
Slide the power supply holder towards the power supply and tighten the screws .

LANCOM Systems GmbH | Adenauerstr. 20/B2 | 52146 Wuerselen | Germany
info@lancom.de
www.lancom-systems.com
© 2023 LANCOM Systems GmbH, Wuerselen (Germany). All rights reserved. LANCOM, LANCOM Systems, LCOS, LANcommunity and Hyper Integration are registered trademarks.
All other names or descriptions used may be trademarks or registered trademarks of their owners.
This document contains statements relating to future products and their attributes.
LANCOM Systems reserves the right to change these without notice.
No liability for technical errors and / or omissions. 111988 01/2023

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals