GOLD NOTE PH-1 MM and MC Phono Preamplifier User Manual
- June 6, 2024
- GOLD NOTE
Table of Contents
- GOLD NOTE PH-1 MM and MC Phono Preamplifier User Manual
- PACKAGE CONTENT
- INTRODUCTION AND OPTIONS
- OPERATING CONDITIONS
- PH-1 GAIN AND LOAD
- TECHNICAL SPECIFICATIONS
- POWER
- DIMENSIONS AND WEIGHT
- FINISHES
- UPGRADES
- REAR PANEL
- WARRANTY
- SERVICE
- PLEASE NOTE
- FAQ
- TROUBLESHOOTING
- IMPORTANT SAFETY INFORMATION
- CAUTION!
- WARNING!
- IMPORTANT SAFETY INFORMATION
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GOLD NOTE PH-1 MM and MC Phono Preamplifier User Manual
PACKAGE CONTENT
- PH-1
- 1 AC cable
- User manual
INTRODUCTION AND OPTIONS
The Gold Note PH-1 is a high performance convenient MM & MC phono preamplifier featuring Ultra Linear Power Supply. The design developed for the PH-1 allows matching easily any kind of MM and MC cartridge with a wide option of set up with easy access impedance setting.The PH-1 enables superior audio purity with any audio system featuring an optional external super Power Supply (PSU).
OPERATING CONDITIONS
Once the PH-1 has been correctly wired and positioned on a solid shelf it is
ready to play.
The PH-1 has been designed for use in Hi-Fi systems in sheltered locations. It
ought therefore to be protected from any eventual variations in temperature
and humidity. Avoid to use the unit close to radiators or other strong heat
sources, electrical and electronic motors, switched on mobile phones etc.
The location in proximity of other audio components is not theoretically
critical, but you should nevertheless pay attention to this. In any case, take
care to unplug completely the unit every time you need to move it, or to move
the turntable on which it is matched.
PH-1 GAIN AND LOAD
The PH-1 should be purchased set up already as per user needs concerning both
Gain and Load. It is anyway possible vary the PH-1 Gain from MM to MC.
It is also possible vary the load impedance on this unit.
Because to do that is necessary to remove the cover of the unit we suggest to
contact the local Gold Note® distributor to avoid of warranty invalidity.
Once the cover is removed it is possible to access the DIP SWITCH with 4
Micro-Switches underneath two black Chokes.
The Micro-Switches 1 and 4 can vary the Gain of the unit: setting the Micro-
Switches towards the NUMBERS SIDE the PH-1 operates in MM mode; while setting
the Micro-Switches towards the ON SIDE the PH-1 operates in MC mode.
The Micro-Switches 2 and 3 are able to vary the load impedance of the unit:
with the Micro-Switches towards the NUMBERS SIDE the PH-1 operates with a fix
47KΩ (right for all MM cartridges); with Micro-Switches towards the ON SIDE
the PH-1 operates with a 470Ω (default) or changing the resistors (optional)
with the unit with a specific load as requested by the user.
TECHNICAL SPECIFICATIONS
Analogue Inputs: MM or MC 1 stereo RCA
THD: <0.05% THD @ 20Hz-20KHz
Signal to Noise Ratio: -88dB
Dynamic Response: 105dB
Frequency Response: 20Hz – 20KHz @ +/- 3dB
Input Impedance: 470Ω MC or 47kΩ MM
Gain: 65dB MC or 45dB MM
Output Impedance: 50Ω
Line Output level: 2V RCA fixed
Input Sensitivity: 0.15mV MC, up to 7.0mV MM
POWER
100-120V / 220-240V, 50/60Hz (depending on market destination, not
convertible)
Power consumption: 20W max Fuse 0,25A F/T
DIMENSIONS AND WEIGHT
Dimensions: 100 L x 105 H x 260 D mm
Weight: Kg. 2.5 net – Kg. 4 boxed
FINISHES
Front panel: Black Glossy Grand Piano
Case finish: Black Powder Coated
UPGRADES
PSU-1 super external power supply
Others: Gold Note Lucca cable
REAR PANEL
WARRANTY
To validate the warranty is necessary to register the unit on the Gold Note
internet web site within 15 days from the purchase on the appropriate area of
the web site: www.goldnote.it/warranty
If the unit is not registered correctly or has been purchased from a different
country of the purchaser home address the unit will not be covered by any
warranty and the registration will be refused.
The warranty does not cover in any case: Tubes, Phono Cartridge Stylus and
Batteries.
SERVICE
Every GOLD NOTE® product is the result of meticulous technological research,
and consequently their correct functioning is guaranteed. In spite of this it
is possible that problems may emerge which non-specialist users cannot
resolve.
In this case, contact your dealer to be advised on how the fault can be
solved.
Do not return any object directly to the factory or to the distributor without
being authorised to do so. In such cases both GOLD NOTE® and the distribution
agents decline responsibility of any kind.
For more information please visit www.goldnote.it/service.
PLEASE NOTE
Descriptions and technical characteristics may vary at any time and without notice.
FAQ
ACTION | DESCRIPTION | HOW TO ADJUST IT |
---|
MATCHING THE CARTRIDGE
|
The MC and MM cartridges may need a specific Gain and Load impedance adjustment.
|
Refer to page 4 of this manual MM to set up properly both the MM or the MC cartridge.
CLEANING THE PHONO STAGE| The Phono Stage is dirty and needs to be cleaned| With EXTREME care use ONLY pure delicate liquid cleaners and a very soft 100% cotton cloth to sweep dust and stains out.
Any acid or not extremely soft cloth will irreversibly damage the Phono Stage fine aesthetic.
Do not use any alcohol to clean the Phono Stage anodized label, or printed parts.
Only dry cloth is allowed
TROUBLESHOOTING
SYMPTOM | DESCRIPTION | CAUSE | REMEDY |
---|---|---|---|
SPEAKER HUMMING PROBLEMS | The speakers hum when the Phono Stage is connected | ||
to the system | The Phono Stage is very SENSITIVE to house environment | ||
positions. | Be sure the position chosen is compatible with the Phono Stage. | ||
The Ground connector is not plugged. | Try to plug or to unplug the ground |
connector always finding the best solution of your audio system.
The Electrical loops created by the ground connection needs to be tried.
The Phono stage Input Interconnect are not plugged.| The “open” input
of the Phono Stage may strongly hum. Always connect the Input Interconnect to
test the Phono Stage.
The listening volume is very high.| Any phono stage designed to achieve good
sonic performances hums a bit when the volume of the amplifier is high. That
is normal and strongly noticeable especially without music and with MC gain
unit selection.
The tone arm and cartridge are not properly installed| Install them well.
Eventually a tone arm cable problem can occur; please check other ways out
The interconnect input and/or output cables are not shielded.| Be sure to
always use shielded cables for Phono Stage connections.
PHONO STAGE (THE) DOES NOT WORK WHEN THE PHONO STAGE IS SWITCHED ON| | The AC
Phono Stage plug is disconnected from the AC wall plug| Connect it being sure
that the AC wall plug works
The interconnect cables are not properly connected to the Phono Stage.|
Connect them properly
The fuse is blown| Substitute the fuse with one of the same value.
Be sure you selected the right Input of the amplifier
IMPORTANT SAFETY INFORMATION
CAUTION!
TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER- SERVICEABLE PARTS INSIDE. REFER ONLY TO QUALIFIED GOLD NOTE SERVICE PERSONNEL FOR SERVICE
WARNING!
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
Do not disassemble any part of the product.
Do not use any part of the product for other purposes.
For service and problems of any kind, contact qualified Gold Note personnel.
Protect the product from rain, humidity and keep away from heat sources,
electric and electronic motors etc.
The power Chord supplied must be used only on this unit.
Gold Note does not have responsibility for any improper use of this unit.
This appliance has a serial number located on the rear panel.
Please record the model and serial number and retain them for your records.
Serial Number:
Model:
IMPORTANT SAFETY INFORMATION
-
Read these instructions and store them.
-
Heed all warnings.
-
Follow the instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block the ventilation openings and install in accordance with the manufacturer’s instructions.
-
Do not install near heat sources such as radiators, heat registers, stoves or other apparatus (including amplifiers) that produce heat.
-
Do not defeat the safety purpose of the polarised or grounding-type plug: a polarised plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety.
If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. -
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
Only use attachments/accessories specified by the manufacturer.
-
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over. -
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel only. Servicing is required when the apparatus has been damaged in any way (such as when the power cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture) and in any case when the apparatus does not operate normally or has been dropped.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>