FONESTAR FSD-4500E PA Power Amplifier Instruction Manual
- June 12, 2024
- Fonestar
Table of Contents
FSD-4500E
PA POWER AMPLIFIER
INSTRUCTION MANUAL
DESCRIPTION
– 4-channel PA power amplifier.
– 100 V or 70 V output for PA installations.
– Highly efficient and reliable class D amplifier thanks to low-maintenance
protection circuits
– Safe and easily connectable euroblock connectors.
– Excellent sound quality and little noise.
CONTROLS AND FUNCTIONS
FRONT PANEL
-
On/Off switch of the stage.
-
CLIP: signal peak indicator light for each input. If the indicator light comes on, it is because the input signal is too high. To solve this problem, reduce the volume of the input signal.
-
SIG: signal status indicator light. It lights up when a signal is detected at the outputs.
-
PROT: protection indicator light. It lights up when the temperature protection of the channel is activated. When the protection is activated, the audio output of that channel is cut off. If this happens, turn off the equipment, make sure that the air intake and exhaust slots are free of obstacles and lower the volume of the input signals. Wait a few minutes for the unit to stabilise before switching it on again.
-
Status indicator light.
– Green: the stage is on.
– Red: priority input active. -
CH A/CH B/CH C/CH D: volume controls for output channels CH A, CH B, CH C and CH D respectively.
REAR PANEL
-
Euro block connector.a.- A/D: balanced audio inputs, each input will be played on the output channel named with the same letter (input A on channel CH A and input B on channel B, etc). If the input signal is unbalanced, the negative pole (-) will be free.
b.- FAIL: system failure indicator signal to monitor the equipment remotely. This output will remain at 5 V if the operation is normal and 0 V when a fault is detected (disabled/protection/inactive).
c.- DIS: input to enable/disable the stage remotely to make modifications to the wiring without having to switch off the equipment from the front button. This input is in open circuit (stage enabled), the circuit must be closed to disable the stage. When the stage is disabled, it is switched off, the LEDs remain lit and the FAIL signal will go from 5 V to 0 V indicating a system fault.
d.- PRIO: input to activate/deactivate priority remotely. This input is in open circuit (priority deactivated), you must close the circuit to activate the priority.
e.- Earth reference.
f.- EMER: audio signal input of an emergency system, together with the PRIO input, the emergency message is clearly emitted. This audio signal shall not be affected by the output volume controls of the power amplifier. -
OUTPUT SET: independent selector switch for each output channel to indicate the type of loudspeaker output desired (70 V or 100 V).
-
SPEAKER OUTPUTS: 4 output zones for the connection of high impedance loudspeakers (70 V or 100 V depending on the OUTPUT SET selector). It is possible to connect 4 zones with 400 W power per zone or 2 zones with 480 W RMS per zone (connect A or B, and C or D).
-
Power supply input of the amplifier 115/230 V.
CONNECTION
– IMPORTANT: it is important that the amplifier is properly cooled, so make
sure that the place where it is installed has access to air flow and that the
chassis slots are free of obstacles.
– With the power off, connect all audio and control sources.
– Connect the loudspeakers to the corresponding outputs (CH A-D) and with the
OUTPUT SET selector indicate the type of output you want for each zone (70 V
or 100 V).
*IMPORTANT: for proper operation and performance of the equipment, use
the correct power, impedance and frequency limits. Before connecting to other
equipment, be aware of the conditions required in a HIGH IMPEDANCE (100 V)
installation.
More information can be found at:
fonestar.com/downloads/install_fonestar_en.pdf
– Check that the volume controls are at minimum and connect the amplifier to
the power supply.
– Turn on the audio sources and other external equipment connected to the
power amplifier first, and the power amplifier last. Finally, adjust both
volume controls.
4 CHANNELS
2 CHANNELS
BLOCK DIAGRAM
TECHNICAL SPECIFICATIONS
| FSD-4500E
---|---
FEATURES| 4-channel PA power amplifier.
100 V or 70 V output for PA installations.
Highly efficient and reliable class D amplifier thanks to low-maintenance
protection circuits Safe and easily connectable euro block connectors.
Excellent sound quality and little noise.
POWER| 4 x 400 W RMS or 2 x 480 W RMS (with single channel of either A/B
or C/D)
RESPONSE| 30-15,000 Hz ±3 dB
DISTORTION| Harmonic: < 0.1 %
INPUTS| 4 balanced/unbalanced aux lines, euroblock, 20,000 Ω/10,000 Ω,
0.9-1.1 V RMS 1 emergency/test, euroblock
OUTPUTS| 1 GPIO fault indicator output, 5 V DC, euroblock
FUNCTIONS| Forced ventilation with variable speed according to the
temperature LED power, protection, priority and peak signal indicators
Emergency input priority/contact closure test, euroblock Disabling/mute via
contact closure, euroblock
PROTECTION| Short circuit, open circuit, temperature, ultrasound and
radio frequency
CONTROLS| Volume for each channel 100/70 V switch on rear panel
IMPEDANCE| 100 and 70 V, euroblock
POWER SUPPLY| 230/115 V CA, 1,200 W maximum
MEDIDAS| 483 x 44 x 380 mm depth. 1 U rack 19”
ACCESSORIES| Anti-slip adhesive pads
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>