CROWN DMT-6-6 Direct Steam Modular Tilting Kettles
Product Information
Direct Steam Modular Tilting Kettles
The Direct Steam Modular Tilting Kettles are commercial kitchen equipment designed for cooking, boiling, and simmering food items.The equipment comes in three different models – DMT-6, DMT-10, and DMT-12, each with varying sizes – 6, 10, and 12 gallons respectively. The model mentioned in this manual is DMT-10-10. The kettles are made of durable stainless steel and can be tilted for easy pouring of the cooked food. The equipment uses direct steam for cooking, and a pressure reducing valve is required if the incoming steam pressure exceeds 45 PSI (310 kPa). The equipment is designed to be operated by qualified personnel only.
Product Usage Instructions
Before installing or operating the Direct Steam Modular Tilting Kettles, it is important to read the installation, operating, andmaintenance instructions thoroughly. The following precautions must be taken while installing and operating the equipment:
- Ensure that everyone involved in the operation of the equipmentis fully trained and aware of precautions.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
- Disconnect the power supply to the appliance before cleaning or servicing.
- Operating, testing, and servicing should only be performed by qualified personnel.
- The equipment is intended for commercial use only. It is not for household use.
The Direct Steam Modular Tilting Kettles come with a splash guard that is not shown in the front view of the equipment. A pressure reducing valve is required if the incoming steam pressure exceeds 45 PSI (310 kPa). The equipment should be installed, adjusted, and maintained by qualified personnel only.
WARNING
Improper installation, adjustment, alteration, service or maintenance can
cause property damage, injury or death. Read the installation, operating and
maintenance instructions thoroughly before installing or servicing this
equipment.
SAFETY PRECAUTIONS
Before installing and operating this equipment, be sure everyone involved in
its operation is fully trained and aware of precautions. Accidents and
problems can be caused by failure to follow fundamental rules and precautions.
The following symbols, found throughout this manual, alert you to potentially
dangerous conditions to the operator, service personnel, or to the equipment.
- DANGER This symbol warns of immediate hazards that will result in severe injury or death.
- WARNING This symbol refers to a potential hazard or unsafe practice that could result in injury or death.
- CAUTION This symbol refers to a potential hazard or unsafe practice that could result in injury, product damage, or property damage.
- NOTICE This symbol refers to information that needs special attention or must be fully understood, even though not dangerous.
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
-
WARNING
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. -
WARNING
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. -
WARNING
Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment. -
WARNING
Disconnect the power supply to the appliance before cleaning or servicing. -
CAUTION
Operating, testing, and servicing should only be performed by qualified personnel. -
NOTICE
This product is intended for commercial use only. NOT FOR HOUSEHOLD USE. -
NOTICE
This manual should be retained for future reference.
Service Connections
Direct Steam Modular Tilting Kettles
SERVICE CONNECTIONS
STEAM SUPPLY: 3/4” (19 mm) IPS for incoming steam at 5-45 PSI(34-310 kPa).*
CONDENSATE RETURN: 1/2” (13 mm) IPS.
FAUCET COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
FAUCET HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
SINK DRAIN: 1-1/8” (29 mm) O.D. tubing.
- Pressure reducing valve is required if incoming pressure exceeds 45 PSI(310 kPa).
ELECTRICAL CHARACTERISTICS
Model
|
Capacity
|
Shipping Weight
|
Min. Clearance
---|---|---|---
DMT-6
|
6 gallon (23 litre)
|
225 lbs. [102 kg.]
|
SIDES 0 [0 mm]
BACK 0 [0 mm]
DMT-10
|
10 gallon (38 litre)
|
245 lbs. [111 kg.]
Service Connections
SERVICE CONNECTIONS
STEAM SUPPLY: 3/4” (19 mm) IPS for incoming steam at 5-45 PSI (34-310 kPa).*
CONDENSATE RETURN: 1/2” (13 mm) IPS.
COLD WATER: 1/2” (13 mm) NPT for cold water to faucet, to fill kettle.
FAUCET COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
FAUCET HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
SINK DRAIN: 1-1/8” (29 mm) O.D. tubing.
- Pressure reducing valve is required if incoming pressure exceeds 50 PSI (345 kPa).
ELECTRICAL CHARACTERISTICS
Model
|
Capacity
|
Shipping Weight
|
Min. Clearance
---|---|---|---
DMT-6
|
6 gallon (23 litre)
|
225 lbs. [102 kg.]
|
SIDES 0 [0 mm]
BACK 0 [0 mm]
DMT-10
|
10 gallon (38 litre)
|
245 lbs. [111 kg.]
Direct Steam Modular Tilting Kettles
SERVICE CONNECTIONS
STEAM SUPPLY: 3/4” (19 mm) IPS for incoming steam at 5-45 PSI(34-310 kPa).*
CONDENSATE RETURN: 1/2” (13 mm)
FAUCET COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
FAUCET HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
SINK DRAIN: 1-1/8” (29 mm) O.D. tubing.
- Pressure reducing valve is required if incoming pressure exceeds 50 PSI(345 kPa).
DIMENSIONS AND SPECIFICATIONS
Model
|
A
|
B
|
Shipping Weight
|
Minimum Clearance
---|---|---|---|---
DMT-10-6
|
15 [381 mm]
|
33.2 [843 mm]
|
390 lbs. [177 kg.]
|
SIDES 0 [0 mm]
BACK 0 [0 mm]
Model
|
Capacity
---|---
DMT-10-6
|
(1) 10 gallon (38 litre) and (1) 6 gallon (23 litre)
Service Connections
SERVICE CONNECTIONS
STEAM SUPPLY: 3/4” (19 mm) IPS for incoming steam at 5-45 PSI (34-310 kPa).*
CONDENSATE RETURN: 1/2” (13 mm)
FAUCET COLD WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
FAUCET HOT WATER: 3/8” (10 mm) O.D. tubing at 25-50 PSI (170-345 kPa), NSF-61
compliant.
SINK DRAIN: 1-1/8” (29 mm) O.D. tubing.
- Pressure reducing valve is required if incoming pressure exceeds 50 PSI (345 kPa).
DIMENSIONS AND SPECIFICATIONS
Model
|
A
|
B
|
Shipping Weight
|
Minimum Clearance
---|---|---|---|---
DMT-10-10
|
15 [381 mm]
|
33.2 [843 mm]
|
390 lbs. [177 kg.]
|
SIDES 0 [0 mm]
BACK 0 [0 mm]
Model
|
Capacity
---|---
DMT-10-10
|
(2) 10 gallon (38 litre)
Introduction
General
All direct connected steam jacketed kettles pertaining to this manual are
direct steam operated pressure vessels of a double-wall stainless steel
construction forming a steam chamber (jacket) enveloping the lower two thirds
of the kettle bowl surface. All kettles are tilting and counter top mounted in
fixed positions on legs.
Capacities
All models are suffixed with either -6, or -10 to indicate the capacity of
that kettle in US gallons.
Functioning Mode
Direct connected steam jacketed kettles consist of a stainless steel bowl and
a stainless steel jacket which envelopes two thirds of the lower surface of
the bowl thus forming a sealed pressure vessel (chamber) into which steam is
introduced by means of a manual control valve.
The kettle bowl is the container for the food product which ideally should be
of a liquid or semi-liquid consistency to achieve complete contact with the
bowl surface and thus fully absorb the heat transmitted through that surface.
The temperatures required for the cooking process to function adequately must
be greater than the boiling
point of the liquid food product. Further, the greater the steam pressure
used, the higher the temperature and consequently the quicker the cooking
process. For example, steam pressurized at 30 p.s.i. attains a temperature of
274 degrees Fahrenheit (135 degrees Celsius).
In the initial stages of the cooking process when the steam comes in contact
with the cold kettle bowl surface it condenses and forms considerable amounts
of water. A thermostatic steam trap should be plumbed to the exit end of the
kettle jacket. This trap is a mechanical device that closes on high
temperatures and opens when the temperature drops thus allowing the water
formed from condensate to exhaust but retain steam under pressure.
Installation Instructions
Unpacking
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
Immediately after unpacking, check for possible shipping damage. If the
appliance is found to be damaged, save the packaging material and contact the
carrier within 15 days of delivery.
We cannot assume responsibility for damage or loss incurred in transit.
Before installing, verify that the gas (natural or propane), the elevation
from sea level and the electrical supply agree with the specification on the
data plate. NOTE: If this appliance is being installed above 2000 feet
altitude, contact your authorized service office to assure that the proper
orifice size for your elevation has been installed.
Installation
WARNING
Plumbing connections must comply with applicable health, safety and plumbing codes.
Ideally an exhaust system should be located directly above the appliance to exhaust steam and heat generated by the appliance.
- Set the unit in place and level using a spirit level
- Ascertain that a floor drain (open gap) is convenient to the appliance drain.
- Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
- Remove appliance and drill holes in locations marked on floor and insert proper anchoring devices.
- Set unit back in position and re-level left to right and front to back.
- Bolt and anchor appliance securely to the floor.
- Seal bolts and flanged feet with Silastic or equivalent compound.
- Connect the steam line to the kettle (3/4” IPS, 5 psi minimum to 45 psi maximum.)
- If the incoming steam pressure is greater than the kettle maximum operating pressure, then a pressure reducing valve (supplied by others) must be installed in the line.
- Connect hot and cold water supply to the faucet.
- Connect the kettle condensate return line to a 2” open air gap drain or to a boiler return line. Each kettle return line must have a suitable steam trap. Boiler return lines must have a check valve (supplied by others).
- The relief valve for the kettle(s) must not be adjusted or closed off as it is set to relieve excess pressure.
- If large amounts of water accumulate in the steam line, it will be necessary to install one or more ball float traps (supplied by others) in the line to eliminate the water.
- A steam line pressure gauge (supplied by others) is also recommended to determine the actual steam pressure coming to the kettle(s).
Operating Instructions
CAUTION
The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance.
- Fill kettle with product to desired level.
- Slowly turn the steam control valve ON to full open position.
- The water or food should boil three to four minutes per gallon. If it does not then incoming pressure should be checked to determine that it is adequate to operate the kettle efficiently.
- Regulate steam control valve depending on type of food being prepared.
- When food is cooked, turn off steam, remove food and clean kettle immediately to prevent residue from drying on kettle bowl surface.
Cleaning
-
WARNING
Disconnect the unit from the power supply before cleaning or servicing appliance. -
CAUTION
The equipment and its parts are hot. Use care when operating, cleaning and servicing. -
CAUTION
Do not use cleaning agents that are corrosive. -
CAUTION
DO NOT allow water near the electrical components.
Your kettle should be cleaned immediately after each use or when cooking a different product. Before cleaning, check that the kettle has cooled enough to touch it.
- Rinse the inside of the kettle thoroughly and drain to remove any food particles.
- Using a nylon brush, clean the kettle with a mild detergent and water. Never use steel wool or scouring powder as it will scratch stainless steel. Plain steel wool can leave small pieces of steel which can rust.
- Rinse the inside of the kettle thoroughly with clean water. Drain the kettle by tilting or by the tangent draw-off valve, depending on model, to allow the detergent and water solution to drain.
- Wipe the exterior of the kettle with a clean, damp cloth.
- Use of cleaning agents that contain chloride, acids or salts are corrosive and may cause pitting and corrosion when used over a period of time; this will reduce the life of the appliances.
- Should pitting or corrosion occur this is not covered by warranty.
- Follow the recommended cleaning instructions. Use a mild detergent, warm water and rinse thoroughly.
What to Do if Surface Rust Appears
Metal utensils should never be used as they will scratch the surface of the
equipment and rust may begin to form. To remove surface accumulation of rust
from the inadvertent use of such utensils, the following procedure may be
used.
CAUTION
Improper use of this procedure may damage your appliance!
- Use undiluted white vinegar with a non-abrasive scouring pad (plastic) or cloth on the affected area to remove the rust stain. The appliance should not be heated and remain at room temperature during the entire cleaning process.
- If the stain resists removal, additional exposure time with vinegar may be required, to a maximum of one hour.
- Thoroughly wash all of the vinegar away with fresh clear water. Dry the surface completely and allow one hour before using the appliance to cook.
Following daily and period maintenance procedures will prolong the life for your equipment. Climatic conditions – salt air – may require more thorough and frequent cleaning or the life of the equipment could be adversely affected..
Preventive Maintenance
No preventive maintenance is required other than adhering to the Cleaning Procedure Instructions.
Safety Valve Maintenance and Testing
-
CAUTION
Under normal operating conditions a “try lever test” should be performed every two months. Under severe service conditions, or if corrosion and/or deposits are noticed within the valve body, testing must be performed more often. A “try lever test” should also be performed at the end of any no n-service period. -
CAUTION
Hot, high pressure fluid may be discharged from body drain and vent during “try lever” test. Care must be taken to avoid any bodily contact. -
CAUTION
High sound levels may be experienced during “try lever” test. W ear proper safety equipment and exercise extreme care! Test at, or near, half of the operating pressure by holding the test lever fully open for at least two seconds to flush the valve seat free of sediment and debris. Then release lever and permit the valve to snap shut.
If lift lever does not activate, or there is no evidence of discharge, turn off equipment immediately and contact a licensed contractor or qualified service personnel.
Troubleshooting
NOTICE
Contact the factory, the factory representative or local service company to
perform maintenance and repairs.
Extremely Slow Cooking Time
Abnormally slow cooking time may be due to insuf ficient steam pressure and/or
volume. Inlet pressures of less than 10 psi will result in slow cooking
performance. Note that pressures approaching the rated kettle pressure are
liable to set off the safety relief valve. If required pressure is not
available to kettle, then volume of steam is notsufficient. Minimum 3/4” pipe
size is required to the kettle, but if the steam generating source is at a
great distance from the kettle, larger pipe will be required. Also check the
core of the steam supply pipe for debris or scalants that impede steam flow.
May require disassembly and inspection.
product with the Crown name incorporates the best in durability and low maintenance. We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance. When service is needed, contact a Crown Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your appliance.
CROWN FOOD SERVICE EQUIPMENT
- A Middleby Company
- 70 Oakdale Road, Downsview (Toronto) Ontario, Canada, M3N 1V9
- Telephone: 919-762-1000
- www.crownsteamgroup.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>