WISSENERGY P60 Mobile Charging Station User Guide
- June 15, 2024
- WISSENERGY
Table of Contents
WISSENERGY P60 Mobile Charging Station
Product Information
Specifications
Model | Certificate | Product name |
---|---|---|
P60 series | CERoHS | P60 CE Standard Electric Vehicle Charger |
Exterior Drawing
The Product Contains
The charging control panel offers protection against overload, short circuits,
and leakage. The output relay controls the on-off of the power supply. The
connector provides the charging interface connected with the electric vehicle,
equipped with a locking device and anti-misoperation function. The signal
light indicates the following statuses: standby, in charging, and faults.
Technical Parameters
Shell material| External Dimension| Weight| Input voltage| Input current|
Input frequency| Maximum power| Output voltage| Output current| Standby Power|
MTBF| Operating temperature| Operating humidity| Applicable altitude| IP Class
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
ABS+PC plastic shell| 26110765mm| 3.2kg| 400V AC Three-phase| 16A| 50Hz /
60Hz| 11kW| AC 400V| 16A 3W| EN 62752| 100,000 hours| -25+55| 5% – 95%| 2000m|
IP66
Charging Status Indicator
Display the Status of the LED indicator light
Charging state | Indicator Light | Plug Light |
---|---|---|
Disconnected Mode | Upper green on | Green off |
Connected Mode | All green on | All green on |
Charging Mode | Rolling | All green on |
Finish Mode | All green on | Green off |
Fault Mode | Flashing red on | Green off |
Operating Instructions
Quick Operation Guide
Simply insert the 16A three-phase CEE plug into the power supply socket. When
the green light is on, the start-up is completed. Please plug in the charging
connector to your vehicle, and a green light will appear. When charging
begins, the green light starts rolling. When the product is not in use, simply
unplug the connector.
FAQ
-
Q: What safety protection features does the product have?
A: The product has safety protection features such as overload protection, short circuit protection, leakage protection, and grounding protection. -
Q: Can I use this charger for indoor and outdoor charging?
A: Yes, the charger is suitable for both indoor and outdoor use. -
Q: What is the operating temperature range for this charger?
A: The charger can operate within a temperature range of -25°C to +55°C. -
Q: What is the IP class of the charger?
A: The charger has an IP66 rating, which means it is protected against dust and high-pressure water jets.
Summary
P60 series CE standard electric vehicle charger adopts an industrial plug at
one end and a TYPE 2 charging plug at the other. It is equipped with vehicle
communication and safety protection functions, which allows electric vehicle
owners to enjoy convenient and safe home charging.
Exterior Drawing
The Product Contains
The charging control panel offers protection against overload, short circuits, and leakage; the output relay controls the on-off of the power supply; the connector provides the charging interface connected with the electric vehicle, equipped with a locking device and anti-misoperation function.
The signal light indicates the following statuses: “standby”, “in charging” and “faults”;
Technical Parameters
Specifications | Model | P60 |
---|---|---|
Technical Specifications | Certificate | CE\RoHS |
Appearance Material | Product name | P60 CE Standard Electric Vehicle Charger |
Shell material | ABS+PC plastic shell | |
External Dimension | 26110765mm | |
Weight | 3.2kg | |
Electrical Indicators | Input voltage | 400V AC Three-phase |
Input current | 16A | |
Input frequency | 50Hz /60Hz | |
Maximum power | 11kW | |
Output voltage | AC 400V | |
Output current | 16A | |
Standby Power | ≤3W | |
Standard | EN 62752 | |
MTBF | 100,000 hours | |
Operating Conditions | Applicable scene | Outdoor/Indoor |
Operating temperature |
-25℃~+55℃
Operating humidity| 5%~95%
| Applicable altitude| <2000m
---|---|---
IP Class| IP66
Cooling mode| Natural cooling
Safety Protection
| Over-voltage protection| Yes
Low voltage protection| Yes
Over current protection| Yes
Short circuit protection| Yes
Leakage protection| Yes
Grounding protection| Yes
Over temperature protection| Yes
Anti-thunder protection| Yes
Human-computer Interaction| LED light| Yes
Charging Status Indicator
Display the Status of the LED indicator light
Fault code | Cause of failure | Display mode |
---|---|---|
1 | CP fault | Fault code 1 |
2 | Low voltage | Fault code 2 |
3 | Over voltage | Fault code 3 |
4 | Ungrounded | Fault code 4 |
5 | Over current | Fault code 5 |
6 | Short circuit | Fault code 6 |
7 | Leakage | Fault code 7 |
8 | Board over temperature | Fault code 8 |
Table 3 List of the indicator light failure
- About the fault code: when red light flashes, it means fault in the system, and the fault code number is the same as the times the red light flashes. The red light stays off for a while after flashing.
- For example, for fault code 5: the red light flashes five times quickly, then stays off for three seconds, and then flashes 5 times again, then stays off for three seconds, and goes on like this.
- When there are multiple faults, it’ll only display one fault code.
- When there’s a short circuit protection fault or a leakage fault, the charging will not continue, which can be recovered only after the charging plug is unplugged and plugged in again; for other faults, it doesn’t need such operation, and the charging will be resumed automatically after the fault is recovered.
Operating Instructions
Quick Operation Guide
- Simply insert the 16A three-phase CEE plug into the power supply socket. When the green light is on, the start-up is completed.
- Please plug in the charging connector to your vehicle, and a green light will appear;
- When charging begins, the green light starts rolling;
- When the product is not in use, simply unplug the connector.
Note: The socket wire harness must be over 2.5 mm²
Cautions
- Failure to follow the instructions may result in danger;
- Please use the product under the following operating conditions;
- Prevent children from touching the product;
- The output is high voltage, personal safety must be observed when in use;
- If a fault has occurred, there might be a risk of getting electric shock or even death. Please cut off the power supply in emergencies;
- Do not disassemble the charger during charging.
About Maintenance
The product has been packed in the factory, strong impact and collision should be avoided during transportation to avoid damaging the product’s outer package. The products should be placed at an ambient temperature of -40℃~+70℃ and relative humidity of no more than 95%. The ambient air should not contain acid, alkali, or other corrosive gases and explosive gases, and should prevent rain, snow, wind, and sand from entering.
Security Warnings
- Failure to follow the instructions may result in danger!
- Please regularly check whether the charging station has visible damage. There may be a risk of getting an electric shock if operating a damaged charging station.
- Make sure that all safety facilities are available at all times and test regularly to ensure proper operation.
- If a ground fault occurs, it must be assumed that the base’s cable carries the voltage, please ensure that no high-voltage power is available in the system before checking the product.
- The users of the charging box must observe the principles and regulations to ensure personal safety and equipment safety.
- Before powering up the equipment, please make sure that the equipment is properly grounded to avoid unnecessary accidents.
- All the tools that do not require exposed metal parts should be insulated to prevent exposed metal parts from touching the metal frame and causing a short circuit.
- Do not modify, refit, or change any part by yourself under any circumstance.
- Ensure the service life and stable operation of the charging station. The operating environment should be kept as clean, homo-thermal, and constantly humid as possible. The charging station must not be used in the presence of volatile gas or flammable atmosphere.
- Make sure that the input voltage, frequency, circuit breakers, and other conditions have already met the specifications before powering up the equipment.
- You need to check if it meets the local regulatory requirements before using the product.
CONTACT US
- Visit: www.wissenergy.com.
- E-mail: info@wissenergy.com.
- Jiangsu Wissenergy Technology Co., Ltd.
- Add: No.188, Lushan Road, Jianye District, Nanjing, Jiangsu, China. Made in China.
References
Read User Manual Online (PDF format)