IP-COM G1008M 8 Port Gigabit Ethernet Switch User Guide
- June 5, 2024
- IP-COM
Table of Contents
IP-COM G1008M 8 Port Gigabit Ethernet Switch
Package contents
- Switch x1
- Power adapter x1
- Quick Installation Guide x1
If any item is missing, damaged, or incorrect, please keep the original packaging and contact the local reseller or distributor immediately.
Installing the switch
Select one mounting method as required.
Option A. Desktop mounting
Put the switch on a stable and flat desktop.
Option B. Wall mounting
Step 1: Drill two holes in the wall in a horizontal distance of 116 mm.
Knock sleeve anchors (self-preparation) into the holes using a rubber hammer
till the sleeve anchor is level with the wall. Then tighten two screws (self-
preparation) into the sleeve anchors using a screwdriver, and keep the screw
heads outside the wall at least 2.7 mm, to ensure that the switch can be hung
on the screws firmly.
Step 2: Align the slots of the switch to the screw heads, and slip the
switch to make it fixed on the screws firmly.
Note: For safety, do not face the air vents of the switch down. This
switch can only be installed on non-flammable walls, The equipment is suitable
for mounting at heights > 2 m
Connecting your devices
Tip: All ports of your switch support the auto MDI/MDIX function, indicating that either straight cable or crossover cable is acceptable to connect your switch to Ethernet devices.
Specifications
Standards
| IEEE 802.3, IEEE 802.3u, IEEE 802.3x,
IEEE 802.3ab
---|---
10/100/1000Mbps RJ45 Part
| Ports 1 to 8
Switching capacity| 16Gbps
Stare-and-forward| Supported
Auto learning &
auto aging
|
Supported
MAC address table| 4 K
Dimension| 140.2 mm• 66.2 mm• 25.2 mm
Power supply
| Input: 100-240 V AC, 50/60 Hz,0.3 A
Output: 9 V DC, 0.6 A
Operating environment| Temperature: (0 – 40) °C
Humidity: {10-90) % RH, non-condensing
Storage environment| Temperature: (-40 – 70)°C
Humidity: {5 – 90) % RH, non-condensing
Transmission rate
| Ethernet: 10 Mbps (half duplex)/ 20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex)/ 200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps {full duplex)
Transmission media
| Ethernet: CAT3 UTP/STP cable or better Fast Ethernet: CAT5 UTP/STP cable or better
Gigabit Ethernet: CAT5e or CAT6 UTP/STP cable
{recommended)
LED indicators
LED indicator | Status | Description |
---|
|
Solid on
|
The switch is connected ta a power source properly.
Off
| The switch is disconnected or not properly connected ta a power source.
1-8
| Solid an| The part is connected properly.
Blinking| Data is being transmitted over the port.
Off
|
The port is disconnected or improperly connected.
CE Mark Warning
This is a Class A product. In a domestic environment, this product may
cause radio interference, in which case the user may be required to take
adequate measures. The mains plug is used as disconnect device; the disconnect
device shall remain readily operable.
NOTE:
- The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
- To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.
Caution
- Adapter Model: BN049-A05009E/BNO49-A05009B
- Manufacturer: SHENZHEN HEWEISHUN NETWORK TECHNOLOGY CO., LTD.
- Input: 100-240 V AC, 50/60 Hz, 0.3 A
- Output: 9 V=0.6A
- DC Voltage
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Caution!
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
NOTE:
- The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
- To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.
Copyright
©2022 IP-COM Networks Co., Ltd. All rights reserved. This documentation (including pictures, images, product specifications, etc.) is for reference only. To improve internal design, operational function, and/or reliability, IP-COM reserves the right to make changes to the products described in this document without the obligation to notify any person or organization of such revisions or changes.
Technical Support
Address: Room 101, Unit A, First Floor, Tower E3, N0.1001, Zhongshanyuan
Road, Nanshan District, Shenzhen, China. 518052
Tel: (86755) 2765 3089
Email: info@ip-com.com.cn
Website: http://www.ip-com.com.cn
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>