Functions and FEATURES
PRODUCT FUNCTIONS
- Milkbar’s advanced flow single electric breast pump has an inbuilt computer microchip control system that mimics a baby’s intermittent suckling actions resulting in highly effective milk production and expression.
- Milkbar’s advanced flow breast pump has two suckling modes – simulation and expression. Under the simulation mode there are 9 adjustable levels of suction, which are able to maintain a constant velocity, massaging the breast to quickly stimulate letdown.
- Under the expression mode there are 9 adjustable levels of suction, this expression mode mimics the long drawn-out suckling action of a baby that expresses the milk once a letdown has occurred.
- Milkbar’s advanced flow breast pump comes with an inbuilt memory system, that remembers your last mode and strength setting when put into ‘stand-by’ mode when switching between sides.
PRODUCT FEATURES
The soft 100% food grade silicone breast cushion is the most comfortable and advanced cushion on the market. Our technology allows Mums to express more breastmilk in less time, comfortably.
Other features include:
- Easy to use digital touch screen technology makes it simple to operate, even in the dark. In 30 minute countdown timer allows you to keep track of your pumping time.
- Hospital grade motor for superior power and effectiveness.
- Sleek design, compact and lightweight for maximum portability.
- Whisper quiet operation with <=60db[A].
TECHNICAL PARAMETERS
- Model Number: SE-9724855LIB/MB
- Power Input: 100-240V~50/60Hz
- Power Output: DC 10V 1.5A
- Power Rating: 15W
- Stimulation Speed: 100T/min
- Stimulating Pressure: Max -0.018MPa, 9 levels vacuum
- Expression Speed: 26-60T/min
- Expression Pressure: Max-0.036MPa, 9 levels vacuum
- Li-ion Battery: 7.4V 1800mAh
- Timer: 30 minutes
- Overall Noise: <=60dB(A)
- RE, REACH, ROHS approved
- Electric Shock Protection: AC adapter class II, Host machine class II
Parts and DESCRIPTIONS
- Dust cover xl PP
- Silicone cushion xl SIL
- Plastic brace xl PP
- Diaphragm xl SIL
- Breast pump body xl PP
- Inner cap plug x2 PP/TPE
- cap xl
- Tubing connector x2 SIL
- Tubing xl
- Valve body xl SIL
- 120ml wide-neck bottle xl PP
- Bottle stand x lPP
- Nipple cover x lPP
- Nipple xl SIL
- Disc collar x l PP
- Bottle lid xl PP
- Bottle adaptor xl PP
- Power adaptor x l
- Pump motor x l
- Valve membrane x 2
IMPORTANT PLEASE NOTE
Please ensure you sterilise all parts of the pump that come into contact with breast milk, prior to each use such as the silicone cushion, breast shield body, silicone cup, valve, neck connector, bottle connector, bottle lid, disc collar, neck converter (when using a standard bottle) must be cleaned and sterilized before each use.
Preparing your PUMP
NOTE
Millcbar electric breast pump comes pre-assembled; however you need to re- assemble it after cleaning. Before assembling, parts which directly get in touch with breast milk, such as silicone cushion, breast shield body, silicone cup, back cover, valve, neck: connector, bottle connector, bottle lid, disc collar, neck converter (when using a standard bottle) must be cleaned and sterilized before each use.
ASSEMBLING EXPRESSION COLLECTION KIT
- Insert the silicone cushion (02) inside of the plastic brace (03). Attach securely to the breast pump body (05).
ASSEMBLING THE DIAPHRAGM
- Place the diaphragm (04) into the breast pump body (05), then screw on the cap (07) tightly.
ASSEMBLING THE VALVE MEMBRANE
- Attach the valve membrane (20) into the hole of the valve body (10), the valve membrane should be pressed flat to avoid air leaks.
- Then place the valve body with membrane attached to the breast pump body (05), securing tightly.
ASSEMBLING THE BOTTLE, HOUSING AND STAND
- Spin the bottle (11) into the breast pump body (05) securing it tightly, and place the bottle into the stand (12).
CONNECTING THE PUMP UNIT TO MILK COLLECTION KIT
- Connect one end of the tubing (09) to the pump motor (19) and the other end to the air vent of the cap (07). Ensure the connectors are inserted fully.
CONNECTING THE PUMP UNIT TO THE POWER SUPPLY
- Connect the power adaptor (18) to the pump motor (19), then connect the power adaptor into an electrical socket to charge, or use while connected if required.
Operation
How to operate your MILKBAR ADVANCED FLOW BREAST PUMP
HOW TO USE
_ Important: _On first receiving your Milkbar advanced flow, connect the AC adaptor to the pump unit and fully charged the pump unit This will tak:e around 3-4 hours. A full charge is indicated by the battery icon on the LCD display. After the lithium-ion battery is fully charged you can use the pump without being attached to a power socket. You can also operate the pump whilst charging if you wish to do so. The pump will operate for 3 hours on a fully charged battery.
- Turn on the pump using the main on/off switch on the underside of the pump unit, then press the power button located on the top side screen of the pump unit
- The pump will automatically begin to pump on the stimulation setting on level 1.
- Adjust the level of vacuum to your comfort by using the+ and – buttons on the LCD display.
- After 2 minutes, the pump will automatically switch to expression mode – or, once letdown has occurred, manually switch the pump to expression mode by pressing the phase button.
- The suction will automatically default to expression level 3 – adjust the level of vacuum for comfort by using the+ and – buttons on the LCD display.
- Sit back and let the pump do the rest of the work.
- The pump has a 30-minute countdown timer visible on the LCD display, to allow you to keep track of your pump time. The pump will automatically switch off and go to standby mode after 30 minutes, and can be restarted at your previous setting by pressing the power button.
About your PUMP
LITHIUM-ION BATTERY
- When the pump is connected to a power socket, it will automatically charge the lithium-ion battery.
- You can operate the pump whilst still connected to a power source if you wish to do so.
- The pump will continua to charge whilst you are operating it
- The pump is designed for maximum portability. The lithium-ion battery can operate for 3 hours after full charge without the need for power socket.
- When the pump is not being charged or used, ensure the on/off toggle switch on the underside of the pump is turned to the off position. This prevents the pump from draining the battery in standby mode, prior to the need to operate the pump.
- The LCD screen shows a real-time visual display of the units battery charge. If the battery power is low, it’s displayed by . The pump will beep and shut down automatically.
- When the battery is being charged and it has its full charge, it will stop charging itself.
- This feature prevents a lithium-ion battery from damage and prolongs its lifespan.
VACUUM STRENGTH AND ADJUSTMENT
- Under the ·stimulation mode· the vacuum strength has 9 adjustable suction levels. By pressing the+ or- button you are able to increase or decrease the suction power until you find the setting most comfortable for you.
- Under the ·expression mode· the vacuum Street has 9 adjustable suction levels. By pressing the+ or- button you are able to increase or decrease the suction power until you find the setting most comfortable for you.
- When switching to the expression mode, it will automatically begin at setting level 3.
- When switching to the stimulation mode it will automatically begin at level 1.
TIMING FUNCTION
- When the pump is turned on, a countdown timer of 30 minutes will begin.
- When the countdown timer finishes, the pump will switch off automatically and enter the standby mode.
- Each time you turn the pump off, it will automatically rest the timer back to 30 minutes.
STIMULATION AND EXPRESSION MODE SWITCHING
- You can manually change the simulation and expression mode settings at your convenience by pressing the phase toggle button.
Troubleshooting your PUMP
IF THERE IS LOW OR NO SUCTION
- Check all connections are proper1y attached at connection points.
- Check the valve membrane is secure and sitting flat against the valve body.
- Check silicone cup is seated properly and has no wear or damage.
- Check the tubing isn’t damaged and is completely dry inside.
- Check the inner cap plug is securely fitted under the cap.
IF THE PUMP CANNOT SWITCH ON
- Check the toggle switch on the underside of the pump is on.
- Ensure the battery has sufficient charge.
- Check the power cord is properly attached to the pump and is the original charger that came with your breast pump ie 12V.
- If El or E2 appears on the LCD display, it means there is an open or short circuit in the internal battery. Please contact us at info@lmllkbarnewzealand.com.
MILK BACKFLOW
- If water is found in the bladder or tubing please rinse the tubing with clean hot water.
- Air dry completely before using.
- Check the diaphragm is not broken or split.
LOW OR NO BREASTMILK OUTPUT
- If you are just beginning to breastfeed or switching from another breast pump. it can take some time for your body to respond to expressing. Consistency and hydration are key.
- Our bodies are all different- you may need a different sized suction lcit or help in another area. Contact us for some one-on-one troubleshooting at info@milkbarnewzealand.com
Safe use of your PUMP
WARNING
- Keep out of reach of children.
- Lithium-ion battery is built-in. Do not remove the battery.
- Use the pump unplugged, to help preserve the life of the battery
- Do not use any adaptors other than those supplied with the breast pump.
- Turn the toggle switch to ‘off when out of use for long periods of time. Please charge once per month when out of use (for no more than 6 hours per charge) to extended battery service life.
- A breast pump suction kit is a personal-use only. Use by more than one person may present a health risk unless adequately sterilized.
- Use caution when sterilising on the stovetop. and never over boil parts.
- Always unplug the cord from the outlet after each use.
- When cleaning the pump unit, unplug the adaptor.
- Ensure the tubing is clean without any drops of water.
- Do not expose electrical unit to water, or use in microwave sterilization devices.
- Do not expose pump unit to high temperatures or fire.
- Electric discharge time will naturally reduce after 6 months due to battery characteristics. This is normal.
- We reserve the right to make product design changes.
Natural breastfeeding feeling MILKBAR’S 3- PHASE EXPRESSION
Contact
Milkbar Maternity and Breastfeeding New Zealand
- Add: Unit 2, 12 Nau Mai Road Nau Mai Business Park, Raglan, 3295
- Phone: +647 974 9347
- milkbarnewzealand.com
- @milkbarnewzealand
Find us on social media! Follow us, comment and tag us in your pictures. We love seeing them!
- info@milkbarnewzealand.com
- Questions, worries or concerns? Send us an email and we’ll get back to you as soon as we can.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>