installation requirements

  • Phillips screwdriver
  • Drill and bit (6mm for wall mount or 3mm for ceiling mount) •Optional: drywall or jigsaw (to cut 18mm hole for wire Ethernet)
  • UTP Cat5/6 cable for indoor installations

Outdoor Installation Requirements

  • The cable outlet opening must be located on the opposite side of the open environment.
  • The cable should face downward when mounting on the wall.
  • Category 5 (or higher) shielded cabling with drain wire must be used for all outdoor wired Ethernet connections and must be connected to the AC ground of the PoE.

We recommend that you protect your networks from harmful outdoor environments and electrostatic discharge phenomena with Ubiquiti’s industrial grade shielded Ethernet cable. For
more information, visit ui.com/toughcable

System Requirements •Linux,
Mac OS X or Microsoft Windows 7/8/10 •Java
Runtime Environment 1.7 (1.8 or later recommended) •Web
Browser: Google Chrome (Other browsers may have limited functionality) •UniFi Controller
Software v5 .4 or later (available at: ui.com/download/unifi)

Powering on the UniFi Access Point The
U6-MESH has auto detection compatible with the following sources:
UniFi Power with Ubiquiti PoE • Switch compatible with PoE+ 802.3at/PoE 802.3af • Ubiquiti Gigabit PoE Adapter (48 Vdc, 0.5 A )

The U6-PRO single pack includes a Gigabit PoE adapter. For multi-pack units, PoE adapters
or a UniFi switch with PoE can be purchased separately.

Connecting to a UniFi switch with PoE

Connect the Ethernet cable from the UniFi Access Point directly to a PoE port on the switch.

Connection to a PoE adapter

  1. Connect the Ethernet cable from the device to the POE port of the PoE adapter.
  2. Connect an Ethernet cable from your LAN to the LAN port of the PoE adapter.
  3. Connect the power cord to the adapter, and then plug the power cord into a power outlet.

Connection to a PoE adapter

Mounting the PoE adapter (optional)

  1. Remove the PoE mounting bracket from the adapter, place the bracket in the desired position and mark the two holes.
  2. Drill holes, if necessary, and secure the bracket using two rivets (not included).
  3. Align the slots on the adapter with the tabs on the PoE mounting bracket, then slide the adapter down.

Mounting the PoE adapter

Software Installation

Download and install the latest version of the UniFi Controller software. Run it and follow the instructions on the screen. The software and step-by-step User Guide instructions are available at: ui.com/download/unifi Once you have installed the software and run the UniFi Setup Wizard, a login screen for the UniFi Controller management interface will appear. Enter the administrator name and password you created and click the option to login.

Software Installation

You can manage your wireless network and view network statistics through the UniFi Controller’s management interface. For information on setting up and using the UniFi Controller software, see the User’s Guide.

Installing the mobile app Ubiquiti also offers a UniFi app, available from the App Store® (iOS) or the Google Play™ Store (Android). You can use it to make use of basic UniFi access point features without the need to set up a UniFi controller. It also allows constant connection of access points for remote controllers (controllers not on the same Layer 2 network) and easy access to local controllers and those being monitored on unifi.ui.com

safety instructions

  1. Read, follow and save these instructions.
  2. Pay attention to all warnings.
  3. Only use the devices or accessories indicated by the manufacturer.

electrical safety information

  1. It is mandatory to comply with the current, frequency and voltage requirements indicated on the manufacturer’s label. Connection to a power source other than those specified may result in malfunction, equipment damage, or fire hazard if limitations are not followed.
  2. This equipment contains no operator-serviceable parts. Only a qualified service technician should provide services.
  3. This equipment is supplied with a detachable power cord that has an integral safety ground wire designed to be connected to a safety ground. to. Do not substitute the power cord with one other than the approved type provided.
    Never use an adapter plug to connect to a two-wire outlet, as it will break the continuity of the ground wire.

The equipment requires the use of the ground wire as part of the safety certification. Modification or misuse can create a shock hazard, which could cause serious injury or death.

If you have any questions about the installation, contact a qualified electrician or the manufacturer before connecting the equipment.

The indicated AC adapter provides a safety ground. For installation in a building, adequate short-circuit back-up protection must be provided.

and. A protective connection must be installed in accordance with national wiring rules and regulations.

limited warranty

ui.com/support/warranty

The limited warranty requires arbitration to resolve disputes on a case-by- case basis and, where appropriate, specifying arbitration instead of jury trials or class actions.

Compliance

FCC

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions.

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide acceptable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.

The FCC has approved this radio transmitter.

Radiation Exposure Statement

  • This equipment complies with radiation exposure limits set forth for an uncontrolled environment.
  • This equipment should be installed and used with a minimum distance of 20 cm between the radiator and your body.
  • This transmitter must not be co-located or used in conjunction with any other antenna or transmitter.

Mexico (NOM-208-SCFI-2016)

For use in Mexico, operation of this equipment is subject to the following two conditions: 1. this equipment or device may not cause harmful interference, and 2. this equipment or device must accept any interference, including interference that may cause unwanted operation.

CE marked

WEEE Compliance Statement

Declaration of conformity

online resources

online resources

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals