KILOTECH KHS-200 Series Mini Crane Scale User Guide

June 12, 2024
KILOTECH

USER’S GUIDE

KILOTECH KHS 200 SERIES
MINI CRANE SCALE

Introduction

Notice
Before you use the scale, please read this manual through carefully, and keep it properly for future use.

Safety Guide
For good performance and precise measurement, be careful with daily operation and maintenance. Note the following instructions:

  • Do NOT overload the scale. This will damage the loadcell and void the warranty.
  • Do NOT leave load hung on the scale for long. This will decrease the scale’s accuracy and shorten the loadcell’s life.
  • Inspect shackle and hook before using.
  • When the scale runs out of power, replace the battery with fresh ones.
  • Do NOT use the scale under thunder or rain.
  • Do NOT attempt to repair the scale yourself.

Contact Kilotech at 800-694-4445, 877-328-5988 or www.kilotech.com.

Specifications

Features

This scale is a combination of the sound and proven mechanical design, with today’s most advanced electronics to provide a superb feature set. It is versatile, reliable, accurate and easy to operate.

Quality| In accordance with OIML R76, GB/T11883-2002. ISO9001-2000 certified quality system.
---|---
Construction & design| Stainless steel load receptor and aluminum-casting case for better safety.
Power| 0.75 inch – 20mm LCD, visual distance over 10m. Dismountable hook.
SMT technology, quality integrated circuit and dedicated weighing loadcell, ensures long stability time.
3*AA battery with low power consumption design.

Specifications

Accuracy Class Chinese GB/T 11883-2002 Class III Equivalent to OIML R76
Tare Range 100% F.S.
Auto Zero ±50% F.S.
Manual Zero ±2% F.S.
Zero-tracking 0.5e/s
Reading Stable Time ≤10 seconds
Auto-sleep Sable and no action in 3 sec.
Auto-off Sable and no action in 3 min.
Overload 100% F.S. + 9e
Max. Safety 120% F.S.
Load 300% F.S.
Ultimate Load >150 hours
Battery Life 3*AA battery
Battery – 10℃ ~ + 40℃
Temp. (Op.) ≤80% at 20℃ (non-condensing)
Humidity (Op.) Display 0.7 inch (17.78mm) numerical
Net Weight 620g

Capacity and Resolution

Model Max. Cap. (kg/lb) E (kg/lb) Division (n)
KHS 200-30 30/60 0.01/0.02 3,000
KHS 200-60 60/120 0.02/0.05 3,000
KHS 200-150 150/300 0.05/0.1 3,000
KHS 200-300 300/600 0.1/0.2 3,000

Schematic Diagram

KILOTECH KHS 200 Series Mini Crane Scale - Specifications
1

Dimension

Operation Guide

Power On

Press for 1 second to power up, battery tests and initializes.
Screen shows detection message while scale detects its load and auto-zero itself.
Power Off
Press for 1 second to power off scale.
Display shows power-off message.
Tare

Press to store weight as tare.

“TARE” shows and weight turns zero.
If weight is over 100%F.S., or lessthan 0, tare is not allowed.
If weight is not stable or held, tare is not allowed.
Taring will reduce scale’s apparent overloading range. E.g., if a 10kg container is tared and scale’s maximum capacity is 50kg, scale will overload at a new weight of 40.18kg (5000 – 1000 + additional 9 divisions).
Press to restore tare.
“TARE” hides, and weight resumes in gross mode.

Hold
Press to lock the display.
“HOLD” shows and display is frozen
Press again to resume display.
“HOLD” hides and display resume refreshing.

Unit Switch
Press for 1 second to switch measuring unit between kg, lb and N.
If scale is tared, or held, unit switching is not allowed.
Zero
Press for 1 second to zero scale.
“ZERO” shows and weight turns zero.
If weight is tared, or not stable, or held, zero is not allowed.
If weight is over Manual-Zero range, zero is not allowed.

Setting

Press and sim ultaneously, and hold the two buttons for 1 second, to enter Setting Mode.
Press to enter Auto-Off option; and press to change
Auto-Off option.
Auto-Off can be set to 0 (disabled), 5 (5min), 15 (15min), 30 (30min), 60 (60min).
Press to enter
Auto-Zero option; and press to change
Auto-Zero option.
Auto-Zero can be set to 0 (disabled), 2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.), 50 (50%F.S.).
Press to enter
Manual-Zero option; and press to change
Manual-Zero option.
Manual-Zero can also be set to 0 (disabled), 2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.), 50 (50%F.S.).
Press to enter
Backlight option; and press to change
Backlight option.
Backlight can be set to off (disabled), 5 (5sec), 15 (15sec), 30 (30sec), 60 (60sec), on (never).
When Backlight is set to 5, 15, 30, or 60, scale turns off backlight in corresponding seconds after it is stable.
When Backlight is set to off, backlight is disabled, and never turns on.
When Backlight is set to on, scale never turns off backlight, no matter it is stable or not.

Press to exit
Settings Mode.

Trouble-shooting

Symptom Possible Causes Solution
blank display when On/Off is pressed discharged battery replace battery

defective battery
defective ON/OFF key| press ON/OFF key for long
no action taken after TARE or
HOLD is pressed| defective TARE or HOLD key| clean TARE or HOLD key
unstable readings| scale in motion| stabilize the load and scale
scale is damped| dry the scale
dust on PCB board| clean PCB board
reading is not zero without load| unstable system power| longer warm-up time
load-cell stressed too much or too long| hang the scale in storage
large error in weight reading| scale is not zeroed before loading| keep the scale unload and reboot
re-calibration needed| re-calibrate the scale
improper unit| switch to proper unit

Note


References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals