KILOTECH Integrator C Retail Scale Instruction Manual

June 12, 2024
KILOTECH

KILOTECH logo

Integrator C
Operation ManualKILOTECH Integrator C Retail Scale Contents subject to change without notice
Version MAN021119-1.03
www.kilotech.com

Introduction

Thank you for choosing a Kilotech Scale. We appreciate your business and hope that you will enjoy using your  scale. Should you require support, please contact your local dealer from whom you have purchased. HappyWeighing!

General Precautions

Avoid lengthy exposure to heat or cold.| Allow the scale to acclimate to normal room temperature before use.
---|---
Allow sufficient warm up time.| Turn the scale on and wait for a few minutes to allow the internal components a chance to stabilize before weighing.
Do not leave a load or weight on a scale for a prolonged period of time.|
Do not tamper with the scale yourself.| This will void the warranty. Contact your local distributor to properly repair your scale.
Do not dissemble the scale yourself.| This will void the warranty. Contact your local distributor to properly repair your scale.
Do not load beyond max cap the maximum weight limit.|
Do not pull the plug by its cord when unplugging.|
Do not use the scale near fire or corrosive gas.|
Do not spill water or immerse in water.|
Avoid placing the scale near a heater.| It could cause a fluctuation to the indicator reading.
Always make sure to use a Kilotech approved adapter.|
Do not drop the scale or apply a sudden shock.|
Do not drag the scale.|
Avoid exposing to other electromagnetic devices.| These devices emit RF and can cause unstable readings. If your scale should perform poorly, try moving the scale to a different room or location.
Level the scale or make sure it is on an even surface.| A scale used on an uneven surface may provide an unstable reading.
Scale should be used within stated temperature & humidity limits.|

Specifications

Product Number| |
---|---|---
Product Name| C15| C30
Capacity| 15kg / 301b / 480oz| 30kg / 601b / 960oz
Graduation| 0-6 kg:2g/6-15kg: 5g 0-151b:0.0051b/15-301b:0.011b 0-240oz:0.1 oz /240-480oz:0.2 oz| 0-15kg:5g/15-30kg:10g
0-30Ib: 0.01lb/30-60lb:0.02lb 0-480oz:0.2 oz/480-960oz:0.5 oz
Weighing Modes| kg, lb, oz
Display| 0.73″,18 digits : 6 digit for weight reading, 6 digit for unit price, 6 digit for total price
Back Light| Yes and adjustable
Auto Power Off| Yes
Power| 12Vdc ?.500mA with positive center AC adaptor
Battery| 6Vdc4AH lead-acid battery
Product Dimensions| 355 x 370 x 131mm/ 14″ x 14.6″ x 5.2″
Platter Size| 335 x 225mm / 13″ x 8.9″
Operating Temperature /| 0° C – 40° C / 32° F – 104° F / <90% RH non condensing
Unit price range| 0.00 – 9999.99 $/kg or $/lb
Total price range| 0-999.99$ (limited by bar code)
RS232| RS232(optional) USB(virtual RS232,optional)
Real Time Clock| Yes
PLU| 265 including 5 direct PLU (Addy: 1-5)
Measurement Canada and NTEP| |

Outline

KILOTECH Integrator C Retail Scale - Outline Interface: (1) Main switch (2) AC power adapter input (3-4) RS232 and USB

Unpacking and setup

  • Remove the scale from the box and place it on a firm, level surface.

  • Avoid locations with rapid temperature changes, excessive dust, moisture, air currents, vibrations, electromagnetic fields, heat or direct sunlight.

  • Adjust the leveling feet until the bubble is centered in the circle of the level indicator (located on the front panel).

  • NOTE: Ensure that the scale is level each time its location is changed.

  • Before using the scale for the first time, the internal rechargeable battery should be fully charged for atleast 12 hours.

  • Connect the supplied AC adapter to the power input receptacle underneath the scale. Plug the AC adapter into a power outlet and the battery will begin charging.

  • If the scale will be stored or transported in the future, save the packaging material to ensure the best possible protection for the scale.

Contents

  • Scale
  • 6Vdc4AH lead-acid battery (installed in scale housing)
  • 12Vdc/500mA UL adapter with positive center
  • Manual

Display and keypad

FaceplateKILOTECH Integrator C Retail Scale -
Faceplate Symbols on Display

  • WEIGHT – Weight display window
  • – Centre-of-zero annunciator
  • – TARE annunciator
  • -Weight unit annunciator
  • UNIT PRICE – Unit price display window
  • – Save mode annunciator
  • – Unit price per kg/lb /oz annunciator
  • TOTAL PRICE($) – Total price display window
  • – Data output annunciator
  • – Charging annunciator
  • – AC Adapter in-use annunciator

Keypad

KILOTECH Integrator C Retail Scale - keys, : numeric keys, Used to enter numerical data or alphabets
: Direct PLU keys, Used to directly recall the stored unit price
: Clear the recorded data
: Confirm the operation or data entered
: Save the tare weight and/or unit price
: Used to set the scale to zero
: Used to tare the scale.
: Enter program PLU mode
: Enter recall PLU mode
: Transmit data to the communication port
: Used to switch between units
: Turns the scale on and off and functions as exit key in programming mode
Layout and characters

| 0 space| | 1ABC
---|---|---|---
| 2DEF| | 3GHI
| 4JKL| | 5MNO
| 6PQRS| | 7TUV
| 8WXYZ| | 9

Key combinations
Press both key simultaneously and hold down for more than three seconds.
(for details on these operations, please see their respective sections in the manual)

| : Used to enter the business’s name setup mode
---|---
| : Used to enter the LCD’s contrast setup mode
| : Used to enter the auto-off time setup mode
| : Used to display A/D inner code or working voltage
| : Used to enter RS232 parameters setup mode
| : Used to enter the date and time setup mode
| : Used to enter Group Code setup mode
| : Used to set OS-203/213 Back Feed setup mode
| : Used to enter OS-203/213 Origin setup mode
| : Enter LCD test mode

Weighing operations

Key functions
Power on/off

  • When the scale is off, first make sure the power switch on the bottom of the right hand side of the scale is ON. Press on/off key to power on the scale.
  • Press on/off for more than 3s to power off the scale.

Zero

  • The zero key is used to zero out the small difference on the weight display.
  • The scale will display “Err” when the weight to be zeroed is outside the range
  • If a tare is set, the ZERO key function is not available

Tare

  • Weight tare: Place the receptacle (box, bowl etc…) on the scale, and when the reading is stable, press tare key to tare the weight.
  • Key tare: Key in known tare weight and press tare key.
  • To clear Zero or Tare, press their respective buttons.
  • The tare weight and unit price will be auto cleared after transaction is completed and item has been removed from the platter.

Save

  • When activated, this function will prevent auto clearing of the unit price or tare-weight.
  • When active, the save indicator is activated.

Units key

  • Use the key to shift between “kg”, “lb”,” oz”.
    Note: Unit price will be set to zero during switching

  • You cannot switch units when a tare is active.

Print

  • Used to transmit the data over the RS232 or USB. When the price has been computed, press print key output the data via RS232 according to the setting style to make a price label. (see appendix for layout example)

Store/program PLU’s

To cancel and return to normal mode at any time, press

Weight Display| Total Price Display| Unit Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press to start|
St.PLU| ADDR| | Enter address using numerical keys
To confirm press| The system will overwrite any previous data
The address range is from 1 to 265
1-5 is for direct unit price
St.PLU| NAME| | Enter product name using numerical key
To confirm press| Use the numerical keys to select the letter needed Only the last six characters will show Max length is 20 characters
St.PLU| INGRDT| | Enter ingredients using numerical keys
To confirm press| This field is only visible when activated
( PRTd60, PRDnd6) Max 80 characters
t.PLU| LIFE| | Enter shelf life using numerical keys
~To confirm press| Refers to shelf life of the product.
Max number of days = 253
St.PLU| “Unit.0” (kg) or
“Unit.1” (lb)| | Use the key to switch
To confirm press|
St.PLU| UNIT.P| | Enter price using numerical keys
To confirm press|
---|---|---|---|---

St.PLU

|

Tare

| | Enter tare weight using numerical keys
To confirm press|
St.PLU| | | Enter item code using numerical keys
To confirm press| If the PLU data has been changed, the unit price window will briefly display “ Save ” and the total price window will briefly display “ Data.ch ”.

Repeat the steps for the next PLU or press to return to the normal weighing mode.
Recall PLU
Recall direct PLU
Recall a PLU that is stored under a speed key by pressing key, the stored unit price will be displayed in unit price window. The total price window will display “DUP. xx”, and then the actual total price will appear.
Recall indirect PLU’s

Icon| Weight Display| Total Price Display| Unit Price Display| Confirm or Exit| Comment
---|---|---|---|---|---
| rc.PLU| **ADDR| Enter the unit price using numerical keys ie010. The address range is from 1 to 265,| To confirm press
To exit and return to regular weighing mode
Press| The unit price winow will display the recalled unit price. The total price window displays “
PLU.** xxx”(xxx is the Address) and then will go back to the normal total price displaying mode later, using the new unit price, tare weight, new weight unit, trade name,and shell life)

Miscellaneous transaction
Use the numerical keys , to enter unit price (range: 0000.00 ~9999.99).
The programmed price can be cleared by pressing the key.
The unit price will be cleared automatically after weighing and removing the objects.

Parameter setting

To cancel and return to normal mode at any time, press the key
Business name

Weight Display| Total Price Display| Unit Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
bUSI.N1| | XXXXXXXXXXXX| Enter first line of Business name using numerical key To confirm press
| Displays the last 12 characters
Max length is 20 characters
bUSI.N1| | XXXXXXXXXXXX| Enter second line of Business name using numerical key
To confirm press

LCD contrast

Weight Display| Total Price Display| Unit Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and holddown for more than three seconds|
Setup| LCd.CST| X| To confirm press| X = value currently set
Setup| BLGT.MD| x| To confirm press| **** 0 = always on 1 = always off 2 = Automatic

Auto off

Weight Display| Total Price Display| Unit Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
Setup| A.OFF.t| XX| To confirm press| XX = value currently set in minutes Max delay = 30 min
00 = auto off disabled

Internal code

Weight Display| Unit Price Display| Total Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
UoL.x.x| CodE| xxxxxx| | UoL.x.x = working voltage
Code = A/D internal count

Communication settings

To cancel and return to normal mode at any time, press the key
The settings in bold are default

Weight Display| Unit Price Display| Total Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
Setup| 232.out| XXXXXX| Chose format using numerical keys
To confirm press| Communication format options.
0 = HOST:
1 = PRTd40
2 = PRTd60
3 = PRTNd4
4 = PRTNd6
(see appendix for details)
Setup| 232.bps| XXXXXX| Choose baud rate using numerical keys To confirm press| baud rate options
1 = 1200bps
2 = 2400bps
3 = 4800bps
4 = 9600bps
5 = 19200bps
Setup| 232.dFt| **** XXX| Choose parity rate using numerical keys To confirm press


| Parity options
1 = 8N1
2 = 7O1
3 = 7E1
---|---|---|---|---
Setup| Prtd.Ft| ** XXXXXX| Choose format using numerical keys To confirm press| 0 = CANADA YY-MM-DD
1 = USA
DD-MMM-YY
2 = Num
Numerical format
Setup| B.PRT.FT| XXXX| Choose format using numerical keys To confirm press|
0 = 5I4P
1 = 4I5P
2 = 5I5P
3 = 4I6P
See Appendix for details barcode formats
**
Setup| USb.oUt| XXXX| Choose format using numerical keys To confirm press **| 0 = None
USB disabled
1 = Host , USB activated.
**
Setup| ** Usb.bps| XXXX| Choose baud rate using numerical keys To confirm press| baud rate options
1 = 1200bps
2 = 2400bps
3 = 4800bps
4 = 9600bps
** 5 = 19200bps
Setup| Usb.dft| XXX| Choose baud rate using numerical keys To confirm press|


Format options
1 = 8N1

2 = 7O1
3 = 7E1

---|---|---|---|---
Setup| Urt.CFt| XXX| Choose format setting using numerical keys To confirm press| 0 = None
1 = S-N
Data will be transmitted when the print key is pressed and scale is stable

The system will automatically reboot after changing the above parameter settings
Set date and time

**Weight Display| Unit Price Display| ****Total Price Display| ****Keys used| ****Comment**
---|---|---|---|---
0.00| 0.00| 0.00| Press both  simultaneously and hold down for more than three seconds|
Setup| dAtE| x.xx.xx| Enter date using numerical keys To confirm press| format: YY.MM.DD
Setup| timE| xx.xx.xx| Enter time using numerical keys To confirm press| Format: hh.mm.ss

Group code

**Weight Display| Unit Price Display| ****Total Price Display| ****Keys used| ****Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
Setup| GroUP.C| XX| Enter time using numerical keys To confirm press| Default =
00** Range = 00~ 99

Back feed

**Weight Display| Unit Price Display| ****Total Price Display| ****Keys used| ****Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
Setup| bAk.FEd| XXXXXX| Choose mode using numerical keys To confirm press| Printer must be on and connected 0 = disable
1 = enable**

Origin setting

Weight Display| Unit Price Display| Total Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both simultaneously and hold down for more than three seconds|
Setup| orG| XXX| Set value using numerical keys To confirm press| Default: 0 Range = 0-255
Setup| orG Y| XXX| Set value using numerical keys To confirm press| Default: 0 Range = 0-255

LCD test

Weight Display| Unit Price

Display

| Total Price Display| Keys used| Comment
---|---|---|---|---
0.00| 0.00| 0.00| Press both and simultaneously and hold down for more than three seconds.
Press key  to exit| Press:
(a)   – show all segments.
b) -show different segments.
(c) – show segments on different COMs.
(d) – show segments of a-b-c steps

Format of barcode for printing

No. Format Type 1 2 3 4 5 6 7 8 9 10 11 12 13
0 5I4P EAN13 G G I I I I I S P P P P C
1 4I5P EAN13 G G I I I I S P P P P P C
2 5I5P EAN13 G G I I I I I P P P P P C
3 4I6P EAN13 G G I I I I P P P P P P C

NOTE: If the fields ( “Price” and “Item code”) are greater than the parameters set, “OUT.P.R” (indicates it is out of printing range) will appear in the weight window.
i.e. you enter 5 digits in a field that needs to be 4 digits.
G:Group Code;
I: Item Code
S:Check-sum for price
P: Total Price (If the weight window displays zero, it will be the unit price);
C:  Check-sum for all characters;

RS-232 cable pinout for host

SCALE ————————CABLE(9 pins)———————— HOST
DB9(Female) ———–DB9(Male)————DB9(Female) ———– DB9(Male)
PIN2 TXD —————-2————————–2——————— PIN2 RXD
PIN3 RXD —————-3————————–3——————— PIN3 TXD
PIN5 GND—————-5————————–5——————— PIN5 GND
PIN4 DSR—————-4————————–4——————— PIN4 DTR
PIN6 DTR—————-6————————–6——————— PIN6 DSR
PIN7 CTS—————-7————————–7——————— PIN7 RTS
PIN8 RTS—————-8————————–8——————— PIN8 CTS
PIN1 NC—————-1————————–1——————— PIN1 NC
PIN9 NC—————-9————————–9——————— PIN9 NC

NOTE: PIN4 and PIN6, PIN7 and PIN8 are shorted in the scale

Printer cable pinout (OS-203/213)

KILOTECH Integrator C Retail Scale - pinout

Error codes

Err01: The weight signal is too large.
Err02: No proper data can be displayed.
 Err03: The weight signal is too small.
Err04: Zero point is over the setting range.
Err05: Zero point is below the setting range.
Err06: Error in unit key operation.
Err10: The EEPROM can’t be accessed.
Err11: The parameters are not same with backup data.
Err12: The setting parameter(s) is not in normal range.
Err20: There is an error in calibration.
Err30: ADC is over max. range.
Err31: ADC is below min. range.
Err40: Recall error, no content stored.
CAP.: Capacity.
UOL.: Voltage.
St.PLU: To set and store the indirect unit price.
 ADDR. : PLU address.
Unit: Weighing unit selecting.
 Rc.PLU: Recall indirect unit price.
OUT.P.R: Data is out of printed barcode range.
Data.ch: Data has been changed.
Save: Data is being saved.
O.RANGE: The data has been entered or the weight for tare weight is out of

range.

Communication output format

Host

Group Code: xx
Date: yy-mm-dd
Time: hh:mm:ss
Gross: xxxx.xxx kg/lb/oz
Tare: xxx.xxx kg/lb/oz
Net: xxxx.xxx kg/lb/oz
Unit Price: xxxxxx.xx $/kg($/lb, $/oz)
Total Price: xxxxxx.xx $

Print format with OS-203 / 213 printerKILOTECH Integrator C Retail
Scale - Print format

Available Label formats

  1. PRTd40 = 58mm × 40mm with date

  2. PRTd60 = 58mm × 60mm with date

  3. PRTNd4 = 58mm × 40mm without date

  4. PRTNd6 = 58mm × 60mm without date

Display Character Reference

KILOTECH Integrator C Retail Scale - icon100

Troubleshooting

Troubleshooting………………………………………………………….Possible causes………………………………………………Solution

Power-on problem| No display after pressing the power on button| ·   Batteries failed
·   No electricity
·   Adapter or plug is not inserted properly.
·   Main switch is off| ·   Check if the batteries
·   Check the power supply with the adapter and ensure the adapter is plugged in properly at both ends
·   Turn on main switch
---|---|---|---
Key button is not working| Contact your supplier
Display irregular characters after you press a button| LCD or its driver IC are not soldered well, or are damaged; or some keys are not free to move down or up| Contact your supplier
Display 888888, does not revert back to 0
Err| Err04| ·   Zero point signal is over or below the limitation
·   There are objects on the platform
·   Load cell is not at zero balance
·   One foot is not level with the others| ·   Remove the objects on the platform
·   Adjust the foot to be level with the other feet. Using the leveling indicator to assist.
·   Contact your supplier
Err05
Err20| ·   Load cell has no output
·   The signal is too small or too large
·   Scale is not stable
·   Input incorrect number or loaded wrong load| ·   Contact your supplier
Err01| ·   The weight exceed 9d of the max capacity
·   The load cell output signal is too big| ·   Empty platter and check for obstruction
·   Contact your supplier
Err31
Err30| The load cell signal is too small or too large.| ·   Contact your supplier
Err11| EEPROM on the PCB broken| Replace with new PCB
Display Lo.bAt| Voltage lower than 5.7V| ·   Charge the battery
·   Contact your supplier for a new battery
Capacity not accurate| Linearity is not accurate| ·   The platform is not installed level
·   The four feet are not level
·   The load cell is broken
·   There are some objects between load cell and scale.| ·   Make sure the platform is level
·   Make sure the four feet are level
·   Clear the objects between load cell and scale
·   Contact your supplier
Big error between the corners| ·   The platform is not installed level
·   The four feet are not level
·   The load cell is broken
·   There are some objects between load cell and scale.| ·   Make sure the platform is level
·   Make sure the four feet are level
·   Clear the objects between loadcell and scale
|  | | ·   Contact your supplier
---|---|---|---
Inconsistent readings| ·   The platform is not installed level
·   Broken load cell
·   Aging problem with PCB
·   There is some objects between load cell and scale.| ·   Make sure the platform is level
·   Make sure the four feet are level
·   Clear the objects between load cell and scale
·   Contact your supplier
Function problem| Key button(s) is/are not functioning| ·   Key button(s) is/ are not working·| ·   Contact your supplier
Communication is erratic| ·   Communication wire is broken
·   The interface is broken| ·   Replace the communication wire
·   Contact your supplier

KILOTECH logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals