RONIS Tronic Plus DOM Keypads Instruction Manual
- June 12, 2024
- RONIS
Table of Contents
Tronic Plus DOM Keypads
Assembly
Instruction Manual
Drilling template
ASSEMBLY
Accessories
Right door assembly
Left door assembly
- Verify that the cable is properly connected (straight and untill the bottom).
Don’t push any key during the wire assembly process.
Relase the batteries thanks to T20 Torx Security screw located on the opposite
of the battery case
Verify that the batteries are in the right polarity (as indicated in the
battery box).
IMPORTANT
The battery pack must remain connected during the release of the batteries.
Otherwise, the internal clock will lose the time configuration.
Important notes Verify that the screws are not fastened too tight
(<20kgf/cm2). LED
lights
After introducing the correct code and pressing ENTER, the three LEDs blink at
the same time (green-yellow-red) and the lock does not work.Dead batteries: replace
batteries.
After pressing any button the yellow LED blinks.Dead or almost dead batteries:
replace batteries.
Batteries
- Make sure the battery pack contfull powered batteries (don’t screw the battery pack too tight to avoid breaking the mechanism)
- If the lock is closed, introduce the user code (or the master one) to open it.
- Replace the old batteries for new ones and disconnect the battery pack.
Important
We suggest to change once every three years the batteries for ensure their
good condition. After a long time, the batteries can deteriorate and damage
the lock, especially in hot environments.
Do not clean the locks with cleaning products with hydrochloric acid, lye or
corrosive components, especially on the metallic parts.