METROPOLITAN N7358-790 Prima Vista 8-Light Aged Antique Brass Chandelier Instruction Manual

October 30, 2023
Metropolitan

INSTALLATION INSTRUCTIONS FOR FIXTURE
Item#N7358-790 (New. 2021/10/14)

N7358-790 Prima Vista 8-Light Aged Antique Brass Chandelier

WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
ASSEMBLING THE FIXTURE (FIG. 1 & Fig. 4)

  1. Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.

  2.  Carefully unpack your new fixture and lay out all the parts in a clean area. Take care not to misplace any small parts necessary for installation.

  3. The arms have been placed to lay flat for shipping. Adjust arms to proper position. (See Fig. 4)

  4. Thread fixture loop (I) onto all thread (J) of upper assembly (K).

  5. Secure stems (M) to all thread (O) of socket assembly (S). Then thread upper assembly (K) to stem (M).

  6. Carefully place the bolts (N) through holes on top of frame assembly (R). Then tighten with plastic washers and finials (Q). METROPOLITAN N7358-790 Prima Vista 8-Light Aged Antique Brass Chandelier - Fig1ASSEMBLING THE FIXTURE (FIG. 2)

  7. Thread all thread (C) into ceiling loop (E) with lock washer (Y1) and hex nut (Y2) until snug.

  8. Thread other end of all thread (C) into crossbar (A) with lock washer (Y1) and hex nut (Y2) until snug. Note: The length of all thread into crossbar may be adjusted if necessary.

  9. Take crossbar assembly and mount to ceiling junction box (Not included) using mounting screws (B) (Size: # 8-32N*L1”). The side of crossbar marked “GND” must face out.

  10. Attach quick link (G) to the fixture loop (I) and chain (H). Quick link must be completely closed when installed. By measuring, determine the correct number of links needed for the desired hanging height. Use a pair of chain pliers to open one end link of the chain and discard excess chain. Slipped the lock collar (F), canopy decorative plate (T) and canopy (D) over the chain (H). Attach another quick link (G) to the other end of the chain (H). Raise fixture and attach quick link (G) to the ceiling loop (E), then close  the quick link (G). Carefully lace fixture wires through chain links and pull until tight. Feed wires through the lock collar, canopy decorative plate, canopy, ceiling loop and all thread, then pull until tight.
    CONNECTING THE WIRE (Fig. 3)

  11. Connect the electrical wires as shown in Fig. 3, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to crossbar using the green screw provided.

  12. Tuck wire connections neatly into junction box.
    COMPLETING THE INSTALLATION (Fig. 1)

  13. Raise canopy (D) and canopy decorative plate (T) to ceiling, then secure with lock collar (F).

  14. Install (8) eight candelabra base bulbs (P) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification.
    —DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!)

Your installation is now complete. Return power to the junction box and test the fixture.
Note: Illustration (Fig. 1) on this manual is for installation purposes only. It may or may not be identical to the fixture purchased.
Notice: It is important to use proper chain pliers (not included) To OPEN and CLOSE the chain included with this fixture. Do not open them with other tools that may twist or stress the chain links. It is important to use proper chain pliers like the ones shown in the diagram.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Metropolitan User Manuals

Related Manuals