spasciani A2B2E2K2P3 H900 Industrial Escape Hoods Instruction Manual
- October 30, 2023
- spasciani
Table of Contents
- spasciani A2B2E2K2P3 H900 Industrial Escape Hoods
- Product Information
- Product Usage Instructions
- ESCAPE HOOD WITH EN 148-1 FILTERS
- USE
- MAINTENANCE / EXPIRY DATE
- STORAGE / TRANSPORT
- CE CERTIFICATION AND MARKING 8.1. EC Certification
- Marking explanation
- ESCAPE HOOD WITH FILTER DIN 58647-7
- LIMITATIONS TO USE
- USE
- MAINTENANCE / EXPIRY DATE
- STORAGE / TRANSPORT
- ESCAPE HOOD FROM FIRE series H 900
- CE CERTIFICATION AND MARKING
- ORDER LIST
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
spasciani A2B2E2K2P3 H900 Industrial Escape Hoods
Product Information
The SPASCIANI SPA Emergency Hood with EN 148-1 filters provides protection against various gases, vapors, and powders. The product is available in two models: H 900 A2B2E2K2P3 and H 900 A2B2E2K2HgP3.
The filters are multigas and powder combined, and the protection offered by each filter is indicated in the table below. The product is disposable and should not be reused. The device’s effectiveness depends on the user’s facial dimensions and structure, such as beards, sideburns, or deep scars, which may interfere with the device’s perfect seal between the half-mask edge, collar, and face.
Model Filter | Protects Against |
---|---|
203 A2B2E2K2P3 R D | Multigas and powders (see table below) |
203 A2B2E2K2HgP3 R D | Multigas and powders (see table below) |
Type of Filter | Distinctive Color | Field of Application |
---|---|---|
A | Brown | Inorganic gases and vapors |
B | Grey | |
E | Yellow | Acidic gases |
K | Green | Ammonia |
Hg | Red | Mercury vapors |
P | White | Powders, fumes, and mists |
Product Usage Instructions
- Before using the product, read the instructions carefully.
- Observe the instructions contained in the manual.
- The device should only be used if the surrounding air has an oxygen content between 17% and 21% by volume (or as specified by applicable national regulations).
- Do not use the device for evacuations in silos or confined spaces or for rescue operations.
- Do not use H 900 A2B2E2K2P3 and H 900 A2B2E2K2HgP3 hoods for fire escape and in the presence of carbon monoxide (CO).
- The devices are disposable and should not be reused. They must be disposed of or sent to Spasciani SPA or authorized workshops for regeneration.
- If the bag does not tear open on the first attempt to open it, grasp the free flap of the bag directly and continue opening it.
ESCAPE HOOD WITH EN 148-1 FILTERS
CAUTION
- Before using the product, read these instructions carefully.
- Scrupulously follow the indications given in this instruction leaflet. The devices that are described must only be used in compliance with these instructions, with the described configurations and specified use. An incorrect and non-conforming use with respect to the instructions could cause a serious hazard.
- The user must fully understand the instructions and follow them at all times: before using the product, the user must decide whether it is suitable for the planned use.
- The instructions must always be kept with the product. Ensure they are well conserved and available for users.
- Breathing devices must only be used by expert, trained staff under the supervision and responsibility of people who are perfectly aware of the application limitations to the equipment and of the laws in force in the country where the equipment is used.
- Maintenance and any repairs to the device must only be carried out by expert, trained staff. SPASCIANI S.p.A. accepts no liability for damage caused further to an incorrect or inappropriate use of the PPE, or due to maintenance or repairs that are not carried out on the premises of SPASCIANI S.p.A. or their expressly authorized service centres.
- Only use original SPASCIANI S.p.A. components and accessories for the maintenance work.
- Do not use any devices which show signs of damage, defects or being incomplete when they are to be used. Do not make any alterations to the device.
| ATTENTION!
All the indications contained in a box with the Ex logo shown on the side refer to explosion risk and indicate those assemblies produced by SPASCIANI S.p.A. suitable to work in the presence of potentially explosive atmospheres (check if the “Ex” symbol is present on the device marking). Failure to comply
with the prescribed regulations can lead to serious risks to personal health and damage to property near the equipment described in this manual.
---|---
|
| ATTENTION!
Always read this user manual before using the device.
DESCRIPTION
The escape hoods Series H 900 have been designed to be used as filtering
respiratory protective device and offer protection in case of leaks from
contaminated atmospheres of chemical substances; they are disposable.
The escape hoods must be used only in the case of danger; they must not be
used under normal working conditions. The escape hoods are available in one
size only.
The H 900 series hoods consist of:
Bag made from antistatic fabric with belt loops, ring for wall-application
and side rings for use with shoulder strap. The hood is placed inside the bag,
sealed in an airtight pocket. The safety seals on the packaging is meant to
ensure the hood has not been used.
-
Bright orange hood, equipped with large anti-fogging screen, self-adjusting elastic harness and elastic sealing collar.
-
Anatomical-shape silicone half-mask designed to perfectly adapt to any face shape.
-
Expiration valve protected by cover.
-
Filter of different types that offer different protection levels:
- Combined filter 203 A2B2E2K2P3 R D type
- Combined filter 203 A2B2E2K2HgP3 R D type
DESIGNED USE
Spasciani H 900 A2B2E2K2P3 and H 900 A2B2E2K2HgP3 escape respirators are
designed for use in sudden leaks from industrial plants, due to accidents or
other reasons, of toxic substances for the respiratory tract. These substances
may be organic or inorganic gas and vapours, sulphur dioxide, hydrochloric
acid and other acid gases, ammonia and its derivates, and dust, smoke and
mist. The masks are suitable for a leak lasting certified 15 minutes and can
only be used once. The hood has also been tested in accordance with the EN 403
standard and therefore has a very high degree of protection; it is class M,
which means it can be worn in by people during the work shift or stored in the
workplace.
Filter performance
The H 900 hood is equipped with high-capacity filters, the performance of
which far exceeds the duration of 15 minutes. They are certified EN
14387:2004/A1:2008 as combined filters with class 2 gas protection and class
P3 particle protection and two models are available:
Filter model | Protects against |
---|---|
203 A2B2E2K2P3 R D | Combined multigas and dust filter, see table below for the |
protection offered
203 A2B2E2K2HgP3 R D| Combined multigas and dust filter, see table below for
the protection offered
Filter types – Color code, description
Filter type | Distinctive colour | Field of application |
---|---|---|
A | Brown | Organic gases and vapors with boiling point > 65 °C |
B | Grey | Inorganic gas and vapours |
E | Yellow | Acid Gases |
K | Green | Ammoniaa |
Hg | Red | Mercury vapours |
P | White | Dusts, fumes and mists |
Below are the breakthrough times, performed under the conditions provided by EN 14387:
Filter type| Class| Gas test| Gas test conc. (PPM)|
Duration (min)
---|---|---|---|---
A| 2| C6H12| 5000| 48
B
|
2
| Cl2| 5000| 32
H2S| 5000| 46
H2S| 10000| 14
HCN| 5000| > 35
E| 2| SO2| 5000| 28
K| 2| NH3| 5000| 52
- test foreseen only by the DIN 58647-7 standard, with a minimum breaking time of 5 minutes.
Filter type| Gas test| Gas test conc. ( mg/m3 )|
Duration (hours)
---|---|---|---
Hg| Hg (vapours)| 13| > 120
And the particle penetration:
Filter type| Test aerosol| Test 1) results (%)| Test 2)
results (%)| Test 3) results (%)
---|---|---|---|---
P3 R D| NaCl| 0.0019| 0.0019| 0.0008
Paraffin oil| 0.0007| 0.0008| 0.0009
- Test 1: Penetration (media calculated 30 sec after the test beginning)
- Test 2: Max Penetration till 120 mg aerosol exposition
- Test 3: Penetration (media calculated 30 sec after the test beginning) after 120 mg aerosol exposition and 24h storage
The performance of the combined filters far exceeds the duration of 15 minutes required for escape filtering devices (see DIN 58647-7) at a double test concentration (5000 ppm used for class 2 against the 2500 ppm required by DIN 58647- 7). This means that the filter guarantees a duration of more than 15 minutes even in the case of environments with high concentrations of pollutants.
As Atex devices, it bears the marking shown below and can be used in the described fields:
| 1G Ex h IIC T6 Ga → Non-electrical devices for use in the surface industry, where there is the possibility that explosive atmospheres due to the presence of gas occur – Zone 0
1D Ex h IIIC T85°C Da → Non-electrical devices for use in the surface industry, where there is the
possibility that explosive atmospheres due to the presence of dust occur – Zone 20
---|---
LIMITATIONS TO USE
-
Only use if the surrounding air has an oxygen volume content between 17 and 21% (or as specified in current national laws).
-
Do not use the device to evacuate silos or confined spaces generally or for rescue operations.
-
Do not use the H 900 A2B2E2K2P3 and H 900 A2B2E2K2HgP3 hoods if carbon monoxide is present (CO).
The devices are for single use only and must not be reused a second time. They must be disposed of or sent to Spasciani SPA or authorized workshops for regeneration. -
The device lea tightness depends on the size and shape of the user’s face, e.g. beard, sideburns, deep scars, could all affect the perfect leaktightness between the half-mask edge, the collar and the face.
-
Users with long hair must make sure to completely cover it with the hood to ensure sealing.
-
The presence of eyeglasses could make it difficult to wear the hood. It is recommended to take them off before using the device.
-
These devices are not recommended for users having narrow neck (circumference < 260 mm, such as children), since the necessary sealing could not be achieved.
-
The respirator can only be used for leaks or self-preservation operations and only if there is a risk of toxic substances even in high concentrations, thanks to the large capacity of the filter in not very high concentrations.
-
The device provides limited protection against solvents with low boiling point.
-
As soon as you smell or taste the pollutants, leave the area: this means the filter is saturated.
USE
Before use
Check the package before use. Do not use the respirator if the seal seems
compromised. Do not use the respirator if the bag is opened or damaged. Always
check the expiry date on the label on the bag.
Use (See Fig.1, 2, 3)
-
Open the bag by gripping with one hand the part marked with the “SPASCIANI” logo and pull strongly downward with the other hand until the sealed part opens completely, as shown in Fig.1. Should the bag not get opened the first time, grasp directly the flap of the bag and open.
-
Pull out the hood by the fabric; avoid pulling by the valve or by the elastic strap; follow the indications given shown in Fig.2.
-
Wear the hood as shown in Fig.3: enlarge the elastic collar using both hands; position and pull the hood over the head until it fits properly.
No special adjustment is required since the elastic strap causes the half-mask to adhere to the face of the user. If the mask is not correctly positioned, grasp it by the filter and pull forward to position properly the mask so that it adheres perfectly to the mouth and nose. The hair must be completely covered by the hood. -
Once the hood is on the user’s face, identify the escape route. Breathe calmly.
After use
The hood used in an atmosphere with contaminants should be disposed, together
with the exhausted filter (see par. 7). If you have worn it but you have not
come into contact with a polluted atmosphere and only the packaging is no
longer intact, the cap can be sent to SPASCIANI SPA for an examination and
possible restoration of the device. Always contact SPASCIANI before sending
the devices to be restored.
MAINTENANCE / EXPIRY DATE
The maximum life of the complete hood is 10 years. When the expiry date of 5 years is reached, as indicated on the label applied to the bag or if the vacuum-sealed aluminum bag is damaged, the product must be sent to Spasciani or to the authorized workshops, which will check the weight of the sealed product; in the event of significant variations in weight, the filter will be replaced (using the restoration kit). After verification, the useful life of the hood will be extended by another 5 years and an additional label will be affixed to the bag indicating the month and year of the next expiry. Respirator maintenance must only be carried out by specialised trained personnel and using only original Spasciani spare parts. Always contact SPASCIANI SPA for assistance and maintenance.
STORAGE / TRANSPORT
The materials used possess excellent anti-ageing qualities. It is, however, recommended to store the new packed respirators in ventilated warehouses, at normal room temperature. Do not expose to direct sunlight and to temperatures lower than -20°C or higher than +50°C. When carried on the belt, avoid immersing the container in water or exposing it to heat sources. Extreme temperatures for long periods could affect the product performances. It is recommended to keep the new devices in their original packaging during transport and storage, so as to protect them from possible impacts and exposure to dust. Avoid overlapping heavy objects on the device to prevent them from getting damaged or deformed.
****| It is recommended to keep the new devices in their original packaging
during transport and storage in order to protect them from possible impacts,
rubbing exposure to dust.
---|---
WASTE DISPOSAL
Dispose of the worn filter and the escape protective hood in compliance
with the local regulations regarding disposal of special wastes.
CE CERTIFICATION AND MARKING 8.1. EC Certification
The H 900 protective hoods are:
- Personal Protection Equipment belonging to category III, as defined by EU Regulation 2016/425/EU, Paragraph I. The CE marking is located on the label on the filter, which represents integral part of the device, and is followed by the number 0426 indicating the Notified Body Italcert S.r.l., Viale Sarca 336, 20126 Milan – Italy, which has carried out the type tests for CE certification, and which performs the production control according to the Module D of the EU Regulation 2016/425/EU. H 900 complete device is not marked with a specific standard, as it only partially meets the requirements of the DIN 58647-7, EN 403 and EN 140 standards. The filters are CE marked according to the EN 14387:2004/A1:2008 standard, present on the label.
- Non-electrical equipment as defined in Annex I of Atex Directive 2014/34/EU. The devices are approved with a voluntary Certificate issued by: Albarubens S.r.l, Via G. Ferrari 21/N – 21047 Saronno (VA) – Italia, N.B. n°2632. The technical reference standards are: EN 60079-32-2: 2015 and EN ISO 80079-36: 2016.
Marking
See Table 1.
Declaration of Conformity
The EU Declaration of Conformity is available on the internet site
www.spasciani.com, in the Downloads section of the product of interest.
ORDER LIST
Name and description | Item code |
---|---|
Industrial escape protective hood H 900 A2B2E2K2P3 | 117250000 |
Industrial escape protective hood H 900 A2B2E2K2HgP3 | 117260000 |
Marking explanation
Table 1
H 900 A2B2E2K2P3
PN 117250000
H 900 A2B2E2K2HgP3
PN 117260000| Trade name and code
---|---
LOT IW12345678| Production batch
S/N 1234| Serial number
| Escape device
| Industrial emergency
| Permitted maximum humidity degree during storage
| Permitted temperature range for storage
| Date de production
| Expiry date (5 years)
| Name of the Manufacturer
MADE IN ITALY| Country where the PPE has been manufactured
| Warning: follow strictly the instructions for use
0426| Notified Body which h performs the production control according to
the Module D of Regulation 2016/425/
1G Ex h IIC T6 Ga 1D Ex h IIIC T85°C|
ATEX Marking (*)
Detailed ATEX marking explanation
| | Specific marking of explosion protection / Marque
---|---|---
II| | Device Groups: II → surface
| |
1| | Device categories: very high level
| | protection (Zones 0 and 20)
| |
G| |
| | Atmosphere: suitable for area with explosive gases, vapors, mists and
air mixtures
| |
| |
D| |
| | Atmosphere: suitable for area in which explosive atmospheres due to
dusts may form
| |
| |
Ex h| | (EPL) / Type of protection offered by the non-
| | electrical device
| |
Ga| | Cat. 1G in Zona 0 / Equivalent level of device protection
| | (EPL): Cat. 1G in Zone 0
| |
Da| | Cat. 1D in Zona 20 / Equivalent level of device protection:
| | Cat. 1D in Zone 20
| |
IIC| | Gas group IIC → Hydrogen (representative gas) /
| |
IIIC| | IIIC gas group →
| | Flammable volatile, non-conductive and conductive dust
T6| | gas: ≤ 85°C / Class of surface
| | temperature of devices for Group II gases: ≤ 85°C
| |
T85°C| | Maximum surface temperature
| | of devices for Group II dusts = 85°C /
| | = 85 ° C
Tamb| -20| Reference temperature for Atex environment
+50°C| |
ARXXATE| Xyyy| Atex Certificate
ESCAPE HOOD WITH FILTER DIN 58647-7
CAUTION
- Before using the product, read these instructions carefully.
- Scrupulously follow the indications given in this instruction leaflet. The devices that are described must only be used in compliance with these instructions, with the described configurations and specified use. An incorrect and non-conforming use with respect to the instructions could cause a serious hazard.
- The user must fully understand the instructions and follow them at all times: before using the product, the user must decide whether it is suitable for the planned use.
- The instructions must always be kept with the product. Ensure they are well conserved and available for users.
- Breathing devices must only be used by expert, trained staff under the supervision and responsibility of people who are perfectly aware of the application limitations to the equipment and of the laws in force in the country where the equipment is used.
- Maintenance and any repairs to the device must only be carried out by expert, trained staff. SPASCIANI S.p.A. accepts no liability for damage caused further to an incorrect or inappropriate use of the PPE, or due to maintenance or repairs that are not carried out on the premises of SPASCIANI S.p.A. or their expressly authorized service centres.
- Only use original SPASCIANI S.p.A. components and accessories for the maintenance work.
- Do not use any devices which show signs of damage, defects or being incomplete when they are to be used. Do not make any alterations to the device.
| ATTENTION!
All the indications contained in a box with the Ex logo shown on the side refer to explosion risk and indicate those assemblies produced by SPASCIANI S.p.A. suitable to work in the presence of potentially explosive atmospheres (check if the “Ex” symbol is present on the device marking). Failure to comply
with the prescribed regulations can lead to serious risks to personal health and damage to property near the equipment described in this manual.
---|---
|
| ATTENTION!
Always read this user manual before using the device.
DESCRIPTION
The escape hoods Series H 900 have been designed to be used as filtering
respiratory protective device and offer protection in case of leaks from
contaminated atmospheres of chemical substances; they are disposable.
The escape hoods must be used only in the case of danger; they must not be
used under normal working conditions. The escape hoods are available in one
size only.
The H 900 series hoods consist of:
Bag made from antistatic fabric with belt loops, ring for wall-application
and side rings for use with shoulder strap. The hood is placed inside the bag,
sealed in an airtight pocket. The safety seals on the packaging is meant to
ensure the hood has not been used.
-
Bright orange hood, equipped with large anti-fogging screen, self-adjusting elastic harness and elastic sealing collar.
-
Anatomical-shape silicone half-mask designed to perfectly adapt to any face shape.
-
Expiration valve protected by cover.
-
Filter of different types that offer different protection levels:
- Gas filter type 901 ABEK against organic gas and vapours with boiling point 65°C, inorganic gas and vapours, acid and alkaline gases.
- Combined filter type 901 ABEK P, against organic gas and vapours with boiling point 65°C, inorganic gas and vapours, acid and alkaline gases, against dust, smoke and mist with protection factor equivalent to a class P2 filter.
DESIGNED USE
Spasciani M 900 ABEK 15 and M 900 ABEK P 15 escape respirators are designed
for use in sudden leaks from industrial plants, due to accidents or other
reasons, of toxic substances for the respiratory tract. These substances may
be organic or inorganic gas and vapours, sulphur dioxide, hydrochloric acid
and other acid gases, ammonia and its derivates, and dust, smoke and mist. The
masks are suitable for a leak lasting 15 minutes and can only be used once.
They do not protect from Carbon Monoxide!
Icon | Device type | Filter type | Certification |
---|
| Industrial escape hood H 900 ABEK 15 and H 900
ABEK P 15
| 901 ABEK 15
901 ABEK P 15
| DIN 58647-7
The hood has also been tested in accordance with EN 403 standard and therefore has a very high degree of protection. As Atex devices, it bears the marking shown below and can be used in the described fields:
| 1G Ex h IIC T6 Ga → Non-electrical devices for use in the surface industry,
where there is the possibility that explosive atmospheres due to the presence
of gas occur – Zone 0
---|---
| 1D Ex h IIIC T85°C Da → Non-electrical devices for use in the surface
industry, where there is the possibility that explosive atmospheres due to the
presence of dust occur – Zone 20
---|---
LIMITATIONS TO USE
- Only use if the surrounding air has an oxygen volume content between 17 and 21% (or as specified in current national laws).
- Do not use the device to evacuate silos or confined spaces generally.
- Do not use the H 900 ABEK15 and H 900 ABEK P 15 hoods if carbon monoxide is present (CO).
- These devices are disposable and must not be used more than once.
- The device lea tightness depends on the size and shape of the user’s face, e.g. beard, sideburns, deep scars, could all affect the perfect leaktightness between the half-mask edge, the collar and the face.
- Users with long hair must make sure to completely cover it with the hood to ensure sealing.
- The presence of eyeglasses could make it difficult to wear the hood. It is recommended to take them off before using the device.
- These devices are not recommended for users having narrow neck (circumference < 260 mm, such as children), since the necessary sealing could not be achieved.
- The respirator can only be used for leaks or self-preservation operations and only if there is a risk of toxic substances in not very high concentrations (if there are high concentrations of toxic substances the usage time could be reduced).
- The device provides limited protection against solvents with low boiling point.
- As soon as you smell or taste the pollutants, leave the area: this means the filter is saturated.
USE
Before use
Check the package before use. Do not use the respirator if the seal seems
compromised. Do not use the respirator if the bag is opened or damaged. Always
check the expiry date on the label on the bag.
Use (See Fig.1, 2, 3)
-
Open the bag by gripping with one hand the part marked with the “SPASCIANI” logo and pull strongly downward with the other hand until the sealed part opens completely, as shown in Fig.1. Should the bag not get opened the first time, grasp directly the flap of the bag and open.
-
Pull out the hood by the fabric; avoid pulling by the valve or by the elastic strap; follow the indications given shown in Fig.2.
-
Wear the hood as shown in Fig.3: enlarge the elastic collar using both hands; position and pull the hood over the head until it fits properly.
No special adjustment is required since the elastic strap causes the half-mask to adhere to the face of the user. If the mask is not correctly positioned, grasp it by the filter and pull forward to position properly the mask so that it adheres perfectly to the mouth and nose. The hair must be completely covered by the hood. -
Once the hood is on the user’s face, identify the escape route. Breathe calmly.
MAINTENANCE / EXPIRY DATE
The maximum life duration of the escape protective hood is of 10 years; as
indicated on the label on the bag, after 5 years it is required to check the
condition of the device. The device must be sent to Spasciani or to Authorised
Workshops, which will check the weight of the product sealed; in case of
significant changes in weight, the filter will be replaced. After
verification, the useful life of the cap will be extended by 5 more years.
The escape protective hood must be disposed of after 10 years.
Maintenance of the escape protective hood must be performed only by specially
trained qualified personnel and should only be made using original spare parts
manufactured by Spasciani.
STORAGE / TRANSPORT
The materials used possess excellent anti-ageing qualities. It is, however,
recommended to store the new packed respirators in ventilated warehouses, at
normal room temperature. Do not expose to direct sunlight and to temperatures
lower than -20°C or higher than +50°C.
When carried on the belt, avoid immersing the container in water or exposing
it to heat sources.
Extreme temperatures for long periods could affect the product performances.
It is recommended to keep the new devices in their original packaging during
transport and storage, so as to protect them from possible impacts and
exposure to dust. Avoid overlapping heavy objects on the device to prevent
them from getting damaged or deformed.
| It is recommended to keep the new devices in their original packaging during
transport and storage in order to protect them from possible impacts, rubbing
exposure to dust.
---|---
WASTE DISPOSAL
Dispose of the worn filter and the escape protective hood in compliance with
the local regulations regarding disposal of special wastes.
CE CERTIFICATION AND MARKING
EC Certification The H 900 protective hoods are:
- Personal Protection Equipment belonging to category III, as defined by the EU Regulation 2016/425, Paragraph I. The CE marking is located on the label on the filter, which represents integral part of the device, and is followed by the number 0426 indicating the Notified Body Italcert S.r.l., Viale Sarca 336, 20126 Milan – Italy, which has carried out the type tests for CE certification, and which performs the production control according to the Module D of the EU Regulation 2016/425. The references to the standards applied for product certification are available on the label: DIN 58647-7.
– Non-electrical equipment as defined in Annex I of Atex Directive 2014/34/EU. The devices are approved with a voluntary Certificate issued by: Albarubens S.r.l, Via G. Ferrari 21/N – 21047 Saronno (VA) – Italia, N.B. n°2632. The technical reference standards are: EN 60079-32-2: 2015 and EN ISO 80079-36:
Marking
See Table 1.
Declaration of Conformity
The EU Declaration of Conformity is available on the internet site
www.spasciani.com, in the Downloads section of the product of interest.
Name and description | Item code |
---|---|
Industrial escape protective hood H 900 ABEK 15 | 117080000 |
Industrial escape protective hood H 900 ABEKP 15 | 117090000 |
H 900 ABEK 15 Restoring kit | 117190000 |
H 900 ABEKP 15 Restoring kit | 117200000 |
ESCAPE HOOD FROM FIRE series H 900
CAUTION
- Before using the product, read these instructions carefully.
- Scrupulously follow the indications given in this instruction leaflet. The devices that are described must only be used in compliance with these instructions, with the described configurations and specified use. An incorrect and non-conforming use with respect to the instructions could cause a serious hazard.
- The user must fully understand the instructions and follow them at all times: before using the product, the user must decide whether it is suitable for the planned use.
- The instructions must always be kept with the product. Ensure they are well conserved and available for users.
- Breathing devices must only be used by expert, trained staff under the supervision and responsibility of people who are perfectly aware of the application limitations to the equipment and of the laws in force in the country where the equipment is used.
- Maintenance and any repairs to the device must only be carried out by expert, trained staff. SPASCIANI S.p.A. accepts no liability for damage caused further to an incorrect or inappropriate use of the PPE, or due to maintenance or repairs that are not carried out on the premises of SPASCIANI S.p.A. or their expressly authorized service centres.
- Only use original SPASCIANI S.p.A. components and accessories for the maintenance work.
- Do not use any devices which show signs of damage, defects or being incomplete when they are to be used. Do not make any alterations to the device.
| ATTENTION!
All the indications contained in a box with the Ex logo shown on the side refer to explosion risk and indicate those assemblies produced by SPASCIANI S.p.A. suitable to work in the presence of potentially explosive atmospheres (check if the “Ex” symbol is present on the device marking). Failure to comply with the prescribed regulations can lead to serious risks to personal health and damage to property near the equipment described in this manual.
---|---
|
| ATTENTION!
Always read this user manual before using the device.
DESCRIPTION
The escape hoods Series H 900 have been designed to be used as filtering
respiratory protective device and offer protection in case of leaks from
contaminated atmospheres of chemical substances; they are disposable.
The escape hoods must be used only in the case of danger; they must not be
used under normal working conditions. The escape hoods are available in one
size only.
The H 900 series hoods consist of:
- Bag made from antistatic fabric with belt loops, ring for wall-application and side rings for use with shoulder strap. The hood is placed inside the bag, sealed in an airtight pocket. The safety seals on the packaging is meant to ensure the hood has not been used.
- Bright orange hood, equipped with large anti-fogging screen, self-adjusting elastic harness and elastic sealing collar.
- Anatomical-shape silicone half-mask designed to perfectly adapt to any face shape.
- Expiration valve protected by cover.
- Filter of different types that offer different protection levels:
- 902 CO P: protects from carbon monoxide and from gases, vapours and dusts possibly released in case of fire
- 902 ABEK CO P: protects from carbon monoxide and from gases, vapours and dusts possibly released in case of fire and/or in case of accidents implying the release of chemical substances, with ABEK-type protection (organic gas and fumes with boiling point > 65°C, inorganic gas and vapours, acid gas and vapours, ammonia) tested according to the requirements of DIN 58647-7 in terms of concentrations and flows.
The ABEK protection is not subjected to CE certification and has been tested only to obtain information on the additional protection; check the Table 1 for the description of the performances.
PERMITTED USE
The Escape Hoods H 900 CO P and H 900 ABEK CO P have been developed to be used
as filtering respiratory protective device during evacuation in case of fire
(H 900 CO P) or fire implying emission of chemical substances (H 900 ABEK CO
P). The hood is intended solely as disposable emergency item and ensures
protection only if the surrounding air has normal oxygen content (17-21%).
Maximum use time: 15 minutes.
The escape hoods comply with EN 403:2004 – M and must be worn by people.
Icon | Device type | Filter type | Certification |
---|
| Fire escape protective hood H 900 CO P| Fire emergency filter 902 CO P| EN
403:2004 (M)
| Combined fire and industrial accidents escape protective hood
H 900 ABEK CO P
| Fire emergency filter 902 ABEK* CO P| EN 403:2004 (M)
- Internal tests performed within the safety limits of the ABEK filter using the test concentrations indicated in Table 1 (flow 30 l/min, as per concentrations indicated).
Table 1
Performances EN 403
Gas | Concentrations | Duration |
---|---|---|
Acrolein [C3H4O] | 100 ppm | > 15 min |
Hydrogen chloride [HCl] | 1000 ppm | > 15 min |
Hydrocyanic acid [HCN] | 2500 ppm | > 15 min |
Carbon monoxide [CO] | 2500 / 5000 / 7500 / 10000 ppm | > 15 min |
Powder | Requirement EN 403 | Penetration |
---|---|---|
Sodium chloride [NaCl] | < 6% | < 6% |
Gas | Concentrations | Duration |
---|---|---|
Cyclohexane [C6H12] | 2500 ppm | 8 min |
Chlorine [Cl2] | 2500 ppm / 1000 ppm | 6 min / 17 min |
Hydrocyanic acid [HCN] | 2500 ppm | > 15 min |
Hydrogen sulphide [H2S] | 2500 ppm / 10000 ppm | > 15 min / > 5 min |
Sulphur dioxide [SO2] | 2500 ppm | > 15 min |
Ammonia [NH3] | 2500 ppm | > 15 min |
As Atex devices, it bears the marking shown below and can be used in the described fields:
| 1G Ex h IIC T6 Ga → Non-electrical devices for use in the surface industry, where there is the possibility that explosive atmospheres due to the presence of gas occur – Zone 0
1D Ex h IIIC T85°C Da → Non-electrical devices for use in the surface industry, where there is the
possibility that explosive atmospheres due to the presence of dust occur – Zone 20
---|---
LIMITS OF USE
- Use only if the surrounding air has an oxygen content volume ranging between 17 and 21%.
- These devices are disposable.
- Users wearing beard and sideburns or having deep scars may not achieve perfect sealing between the mask and the face.
- Users with long hair must make sure to completely cover it with the hood to ensure sealing.
- These devices are not recommended for users having narrow neck (circumference < 260 mm, such as children), since the necessary sealing could not be achieved.
- The presence of eyeglasses could make it difficult to wear the hood. It is recommended to take them off before using the device.
- Since the hood filters contain a catalyst, under certain conditions the user could experience an increase in the temperature of the air inhaled. This does not affect the performance of the filter and the health of the user
USE
Before use
Check the package before use. Do not use the respirator if the seal seems
compromised. Do not use the respirator if the bag is opened or damaged.
Always check the expiry date on the label on the bag.
Use
(See Fig.1, 2, 3)
-
Open the bag by gripping with one hand the part marked with the “SPASCIANI” logo and pull strongly downward with the other hand until the sealed part opens completely, as shown in Fig.1. Should the bag not get opened the first time, grasp directly the flap of the bag and open.
-
Pull out the hood by the fabric; avoid pulling by the valve or by the elastic strap; follow the indications given shown in Fig.2.
-
Wear the hood as shown in Fig.3: enlarge the elastic collar using both hands; position and pull the hood over the head until it fits properly.
No special adjustment is required since the elastic strap causes the half-mask to adhere to the face of the user. If the mask is not correctly positioned, grasp it by the filter and pull forward to position properly the mask so that it adheres perfectly to the mouth and nose. The hair must be completely covered by the hood. -
Once the hood is on the user’s face, identify the escape route. Breathe calmly. The air inhaled could be slightly heated; it is normal operation and indicates that the filter is filtering.
| WARNING!
The device must not be used in environments where a high concentration of
gas of the IIC group (> 10%) could occur, since the filter could overheat and
pose a danger to the user. The device is a filtering type and the condition of
breathable air must always exist, that is, with an O2 concentration> 17%.
---|---
MAINTENANCE / EXPIRY DATE
The maximum life duration of the escape protective hood is of 10 years; as
indicated on the label on the bag, after 5 years it is required to check the
condition of the device. The device must be sent to Spasciani or to Authorised
Workshops, which will check the weight of the product sealed; in case of
significant changes in weight, the filter will be replaced. After
verification, the useful life of the cap will be extended by 5 more years.
The escape protective hood must be disposed of after 10 years.
Maintenance of the escape protective hood must be performed only by specially
trained qualified personnel and should only be made using original spare parts
manufactured by Spasciani.
| WARNING!
Since the devices are disposable, no cleaning is required. If there is a
need to clean the container, use a damp cloth.
---|---
STORAGE / TRANSPORT
The materials used possess excellent anti-ageing qualities. It is, however,
recommended to store the new packed respirators in ventilated warehouses, at
normal room temperature. Do not expose to direct sunlight and to temperatures
lower than -20°C or higher than +50°C.
When carried on the belt, avoid immersing the container in water or exposing
it to heat sources.
Extreme temperatures for long periods could affect the product performances.
It is recommended to keep the new devices in their original packaging during
transport and storage, so as to protect them from possible impacts and
exposure to dust. Avoid overlapping heavy objects on the device to prevent
them from getting damaged or deformed.
| It is recommended to keep the new devices in their original packaging during
transport and storage in order to protect them from possible impacts, rubbing
exposure to dust.
---|---
WASTE DISPOSAL
Dispose of the worn filter and the escape protective hood in compliance with
the local regulations regarding disposal of special wastes.
CE CERTIFICATION AND MARKING
EC Certification
The H 900 protective hoods are:
-
Personal Protection Equipment belonging to category III, as defined by the EU Regulation 2016/425, Paragraph I. The CE marking is located on the label on the filter, which represents integral part of the device, and is followed by the number 0426 indicating the Notified Body Italcert S.r.l., Viale Sarca 336, 20126 Milan – Italy, which has carried out the type tests for CE certification, and which performs the production control according to the Form of the EU Regulation 2016/425. The references to the standards applied for product certification are available on the label:
EN 403:2004 followed by class M (devices designed to be worn on persons) -
Non-electrical equipment as defined in Annex I of Atex Directive 2014/34/EU. The devices are approved with a voluntary Certificate (Annex 3 of the 2014/34/UE Directive) issued by: Albarubens S.r.l, Via G. Ferrari 21/N –21047 Saronno (VA) – Italia, O.N. n°2632. The technical reference standards are: EN 60079-32-2: 2015 and EN ISO 80079-36: 2016.
Marking
See Table 2.
Declaration of Conformity
The EU Declaration of Conformity is available on the internet site
www.spasciani.com, in the Downloads section of the product of interest.
ORDER LIST
Name and description | Item code |
---|---|
Fire escape protective hood H 900 CO P | 117110000 |
Combined fire and industrial accidents escape protective hood H 900 ABEK CO P |
117100000
H 900 CO P Restoring kit| 117210000
H 900 ABEK CO P Restoring kit| 117220000
SPASCIANI S.p.A.
Via Saronnino, 72 – 21040 Origgio (VA) – Italy
www.spasciani.com
Cod. 960630000 rev.1 –