Spasciani M 900 P3 Emergency Escape Device Instruction Manual

October 30, 2023
spasciani

Spasciani-LOGO

Spasciani M 900 P3 Emergency Escape Device

Spasciani-M-900-P3-Emergency-Escape-Device-PRODUCT

Product Information

The SPASCIANI SPA M 900 P3 is a half-mask respirator without an inhalation valve. It comes with an EN 1827 FM P3 NR certified anti-dust filter that is securely housed in the respirator. The respirator is made up of a molded anatomical silicone half-mask that has a specific plug-in connection to house the filter. The respirator also has a covered exhalation valve and a two-point silicone strap with quick adjustment buckles. The device conforms to EU regulation (EU) 2016/425 and is certified according to the EN 1827:1999+A1:2009 standard.

Usage Instructions

  1. Before using the respirator, carefully read the instructionleaflet provided.
  2. Ensure that the respirator fits securely on your face. The device’s leak-tightness depends on the size and shape of your face.
  3. Do not use the respirator in atmospheres enriched with oxygen or in the presence of carbon monoxide (CO).
  4. The device is not to be used for evacuations in silos orconfined spaces.
  5. Follow the maintenance intervals mentioned in the instruction leaflet.
  6. For maintenance, perform regular visual checks, clean and disinfect the respirator, and replace the exhalation membrane as per the instructions given in the leaflet.
  7. For replacement parts, refer to the order list provided in the instruction leaflet.

CAUTION

  • Before using the product, read these instructions carefully.
  • Scrupulously follow the indications given in this instruction leaflet. The devices that are described must only be used in compliance with these instructions, with the described configurations and specified use. An incorrect and non‐conforming use with respect to the instructions could cause a serious hazard.
  • The user must fully understand the instructions and follow them at all times: before using the product, the user must decide whether it is suitable for the planned use.
  • The instructions must always be kept with the product. Ensure they are well conserved and available for users.
  • Breathing devices must only be used by expert, trained staff under the supervision and responsibility of people who are perfectly aware of the application limitations to the equipment and of the laws in force in the country where the equipment is used.
  • Maintenance  and  any  repairs  to  the  device  must  only  be  carried  out  by  expert, trained staff. SPASCIANI S.p.A. accepts no liability for damage caused further to an incorrect or inappropriate use of the PPE, or due to maintenance or repairs that are not carried out on the premises of SPASCIANI S.p.A. or their expressly authorized service centres.
  • Only use original SPASCIANI S.p.A. components and accessories for the maintenance work.
  • Do not use any devices which show signs of damage, defects or being incomplete when they are to be used. Do not make any alterations to the device.

DESCRIPTION

The M 900 P3 particle respirator is certified according to the EN 1827:1999+A1:2009 standard, with the following designation: half‐mask without inhalation valve EN 1827:1999 FM P3 NR.
The half‐mask is formed of:

  • Moulded anatomical silicone half‐mask, with a specific plug‐in connection to house the filter and with an exhalation valve protected by a cover.
  • Silicone harness with a 2‐point connection and fast adjustment buckle.
  • M 900 FM P3 NR particle filter, firmly tightened inside the half‐mask.

DESIGNED USE

Spasciani’s M 900 P3 half‐mask with particle filter offers protection from dust, smoke and mist in the air inhaled by the user, and it can only be used once.
Using the device is subject to the correct maintenance and replacement of the filter. It does not protect from Carbon Monoxide!

LIMITATIONS TO USE

  • Only use if the surrounding air has an oxygen volume concentration between 17 and 21% (or as specified in current national laws).
  • Do not use in oxygen enriched atmospheres.
  • Do not use the device to evacuate silos or confined spaces generally.
  • Do not use if carbon monoxide is present (CO).
  • The  device  leaktightness  depends  on  the  size  and  shape  of  the  user’s  face,  e.g. beard, sideburns, deep scars, could all affect the perfect leaktightness between the mask edge and the face.
  • It is a disposable filter that must not be used more than once.
  • The half‐mask allows wearing goggles.
  • The  respiratory  protection  device  must  be  chosen  considering  the  concentration and type of pollutant that protection is needed against.
  • No protection is given against any type of gas or vapour.
  • The respirator must be changed when breathing resistance becomes unbearable.
  • The respirator must be used for one work shift only.
  • The respirator can be used in explosive environments.

USE

Before use
Visually check the half‐mask before using it. If the mask or filter looks damaged, do not use  the  respirator.  Always  check  the  expiry  date  on the  container  label.  Expired  respirators must not be used.

Use
See Fig.1 and Fig.2
Place the half‐mask over your face, pass the harness around your neck taking care that the straps do not get twisted, as shown in fig. 1, then adjust them by pulling the ends, not too tight, until the mask is perfectly tightened (fig. 2).
A leaktightness test can be performed: cover the filter with both hands and breath out hard. If any air passes through the facepiece, position it better and tighten the harness more.

STORAGE

The materials used have excellent anti‐age properties. However, it is advisable to store new, packaged respirators in a well‐ventilated storage rooms at normal room temperature. Do not expose them to direct sunlight or temperatures below ‐20°C or above +50°C. Prolonged exposure to extreme temperatures could reduce the product shelf life.
The maximum life for an escape respirator is 10 years, as shown on the packaging label. Dispose of the escape respirator after 10 years (see the half‐mask production date printed inside it).
It is advisable to keep new devices in their original packaging during transport and storage, to protect them from shocks and dust. Do not place heavy items on top of the device because they could damage and deform it.

MAINTENANCE

Maintenance serves to reinstate the respirator, so it can be used again.

Maintenance intervals

Maintenance operations 1 2 3 4
Visual check X   X
Cleaning and disinfecting   X  
Changing the exhalation membrane     Xa) Xb)
  1. Before use
  2. After use
  3. 1 year –
  4. 2 years
    • a) half‐mask in use
    • b) half‐mask not in use

Cleaning and disinfecting
The half‐mask must be cleaned carefully after each use to remove all traces of sweat and condensation from inside. To do this, remove the filter, and wash the mask with warm water using neutral soap and a soft cloth. Rinse under running water. To disinfect the mask, rub the silicon part in contact with the user’s face using a cloth soaked in normal disinfectant (e.g. solution based on electrolytic oxidising chlorine).
Rinse carefully under running water to prevent the silicone absorbing the cleansing and disinfecting substances. It is always advisable to wash and disinfect it after each use. Do  not  use  solvents  (e.g.  acetone  or alcohol)  or  detergents  containing  abrasive  particles.

Maintenance intervals

Check the half‐mask
It is good practice to check the respirator is in good working order before each use and,  if  the  mask  is  in  storage,  every  year.  Carefully  check the  membrane  in  the  exhalation valve is in good condition and not stuck to its housing, and also check the facepiece  and  harness  are  in  good condition.  If  any  parts  need  changing,  only  use  original Spasciani spare parts (contact the commercial office for any spare parts that are not listed in paragraph 8).

Changing the exhalation membrane
To check and change the exhalation membrane, if need be, without using any tools, proceed as follows:

  • Open the valve cover by pulling the tab on the edge.
  • Remove the membrane by pulling it forcefully outwards
  • Change the membrane, sliding the pin into the hole and pulling it from inside the  half‐mask
  • Replace the cover.

Changing the filter
To change the filter without using any tools, proceed as follows:

  • By hand, pull the filter out of its housing in the half‐mask
  • Throw the used filter away
  • Insert the new filter after removing its protective film: place the filter connection in its  housing  in  the  half‐mask  at  an  angle  of  approximately  60°;  rotate  the  filter pushing it into the half‐mask until it is firmly fixed in place.
  • Check the filter is in the correct position by looking inside the half‐mask.

Disposal
Used  filters  must  be  disposed  of  as  hazardous  waste,  according  to current  waste  disposal laws.

CERTIFICATION AND MARKINGS

EC Certification
M 900 P3 half‐masks are Personal Protection Equipment of complex design as defined in Annex I of Regulation (EU) 2016/425. The EC mark is on the filter label, an integrative part of the device, and is followed by number 0426, which indicates the Notified Body: Italcert S.r.l., Viale Sarca 336, 20126 Milan – Italy, which conducted the type tests for EC certification and which controls production according to D Module of Regulation (EU)  2016/425. Beneath  the  EC  mark  is  the  reference  technical  standard  used  for product certification: EN 1827:1999+A1:2009. The EC mark is also put on the bag label.

Markings
The transparent bag holding the half‐mask has a label with the following markings: See Table 1
Some of these markings can be seen through the transparent bag on the filter, which gives the device name M 900, the filter classification FM P3 NR and the filter trade code 125040000.
The important parts in terms of safety are marked as follows:

  • Exhalation membrane with code RS401 and date stamp (year only)
  • Half‐mask with date stamp and special alphabetic mark, where B indicates the half‐mask code 603300001, and the product name M900
  • Harness  with  the  date  stamp  and  special  alphabetic  mark,  where  A  indicates  the  harness code cod.606170000, and also the Spasciani brand.
  • The filter is marked with the model name, type and class FM P3NR, reference to the EN 1827 standard, with a white label in compliance with EN 143.

Declaration of Conformity
The EU declaration of conformity is available on the website www.spasciani.com in the Download section of the product of interest.

ORDER LIST

Name and description Item code
M 900 P3 Industrial escape respirator 117050000
M 900 P3 Filter change kit 117120000
Exhalation membrane change kit (5 membranes) 117130000

Tab.1

M 900 P3

P/N 117050000

|  Trade name and code
---|---

| Maximum storage humidity level
**| Storage temperature range
EN 1827:1999+A1:2009|  Reference technical standard
**
| Manufacturer’s brand
LOT 17/12345| Production batch
| Production date
| Expiry date

****| Scrupulously observe the usage instructions

MADE IN ITALY| Country where the PPE is made

SPASCIANI S.p.A.