Product Information
The product is a hanging light fixture with item number N7753-143. It comes with a cloth shade (H) and a metal frame (J) that holds an acrylic sheet (M) and two medium base bulbs (N) with a maximum wattage rating of 60 watts each. The fixture also includes rods (F1, F2, F3), a circular strap (B) with mounting screws (C), and knobs (E) to secure the canopy (D) to the rods. The installation manual warns users to shut off power at the fuse box or circuit breaker box before installation and not to exceed the maximum wattage rating when installing bulbs.
Product Usage Instructions
-
Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
-
Unpack the new fixture carefully and lay out all parts in a clear area. Take care not to misplace any small parts necessary for installation.
-
Loosen screws (I) to remove cloth shade (H) from metal frame (J).
-
Remove plastic tape from cloth shade (H) and place acrylic sheet (M) into the bottom of cloth shade (H).
-
Install two medium base bulbs (N) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification — DO NOT EXCEED THE MAXIMUM WATTAGE RATING!
-
Place cloth shade (H) into metal frame (J) and secure with screws (I).
-
Determine the desired hanging height and thread rods (F1, F2, and F3) to all thread (G) on the fixture body. Attach canopy (D) by screwing onto rod (F1). Carefully pass the wires through each rod during assembly. Note: Remove all thread, if installing with one 6 rod only.
-
Thread screws (A) into pre-drilled holes in circular strap (B).
Spaced the same distance apart as the holes in the canopy (D). The length of screws (A) may be adjusted if necessary. -
Attach circular strap (B) to junction box (not included) with mounting screws (C) (Size: #8-32N*L0.5). The side of the mounting plate marked GND marked on it and two convex points must faceout.
-
Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the circular strap (B) using the green screw provided.
-
Tuck wire connectors neatly inside the junction box.
-
Thread screws (A) into canopy (D), and secure with knobs (E).
-
Lock metal frame (J) and metal frame (L) together with screws (K).
-
Turn on power at the fuse box or circuit breaker box and test the fixture.
WARNING ! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
HANGING THE FIXTURE
-
Shut off power at the fuse box or circuit breaker box and remove the old fixture including the mounting hardware.
-
Carefully unpack your new fixture and lay out all the parts in a clear area. Take care not to misplace any small parts necessary for installation.
-
Loosening screws (I) to remove cloth shade (H) from metal frame (J).
-
First remove plastic tape from cloth shade (H). Then place acrylic sheet (M) into the bottom of cloth shade (H).
-
Install (2) two medium base bulbs (N) up to 60 watts each or CFL or LED equivalent (not included) in accordance with the fixture specification—DO NOT EXCEED THE MAXIMUM WATTAGE RATING! (NE PAS DEPASSER LA PUISSANCE NOMINALE MAXIMALE!).
-
Place cloth shade (H) into metal frame (J) and secure with screws (I).
COMPLETING THE INSTALLATION (Fig. 1) -
Determine the desired hanging height and thread rods (F1, F2 and F3) to all thread (G) on the fixture body. Attach canopy (D) by screwing onto rod (F1). Carefully pass the wires through each rod during assembly.
Note: Remove all thread, if installing with one 6” rod only. -
Thread screws (A) into pre-drilled holes in circular strap (B). Spaced the same distance apart as the holes in the canopy (D). The length of screws (A) may be adjusted if necessary.
-
Attach circular strap (B) to junction box (not included) with mounting screws (C) (Size: #8-32N*L0.5”). The side of the mounting plate marked “GND” marked on it and two convex points must face out.
CONNECTING THE WIRES (Fig. 2) -
Connect the electrical wires as shown in Fig. 2, making sure that all wire connectors are secured. If your junction box has a ground wire (green or bare copper), connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the circular strap (B) using the green screw provided.
-
Tuck wire connectors neatly inside the junction box.
-
Thread screws (A) into canopy (D), and secure with knobs (E).
-
Lock metal frame (J) and metal frame (L) together with screws (K).
Your installation is now complete. Return power to the junction box and test
the fixture
Note: Illustration (Fig.1) on this manual is for installation purposes