WATTS BT-A03 RF Electronic Room Thermostat Installation Guide
- October 30, 2023
- WATTS
Table of Contents
Quick Installation Guide
Vision® Wireless
Electronic Room Thermostat
BT-A03 RF
Box Contents
1x 1x 1x 1x 1x
Installation
Safety warnings and operating instructions
This product should be installed preferably by a qualified professional. All
instructions in this Installation & Operation manual should be observed when
working with the controller. Failures due to improper installation, improper
use or poor maintenance are voiding manufacturer liability.
Batteries may explode or leak, and cause burn injury, if recharger, disposed
of fire, mixed with a different battery type , inserted backwards or
disassembled. Replace all used batteries at the same time. Do not carry
batteries loose in your pocket or purse. Do not remove the battery label. Keep
batteries away from children. If swallowed, consult a physician at once.
Fig. 1 Fig. 2
Fig. 3 Fig. 4
(B) BLUE (Y) YELLOW (R) RED (G) GREEN
Dimensions
Pairing
Fig.1
Reset
WALL
Fig. 2
TABLE
Fig. 2
The descriptions and photographs contained in this document are supplied by way of example and illustration only. Watts Industries reserves the right to carry out any technical and design improvements to its products without prior notice. Watts hereby objects to any term, different from or additional to Watts terms, contained in any buyer communication in any form, unless agreed to in a writing signed by an officer of Watts.
2012/19/EU: Products marked with this symbol cannot be disposed of as unsorted
municipal waste in the European Union. For proper recycling, return this
product to your local supplier upon the purchase of equivalent new equipment,
or dispose of it at designated collection points.
For more information see: www.recyclethis.info
2006/66/EC: This products contains a battery that cannot be disposed of as
unsorted municipal waste in the European Union. See the product documentation
for specific battery information. The battery is marked with this symbol,
which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg).
For proper recycling, return the battery to your supplier or to a designated
collection point. For more information see: www.recyclethis.info
Fig. 3
Fig. 3
Floor Sensor
Fig. 4
Environmental:
Operating temperature
Shipping and storage temperature | 0°C to +50°C (32°F to +122°C), – 20°C to
+60°C (-4°F to +140°C)
---|---
Electrical protection
Class ErP
Energy efficiency gain| IP30
Level IV
2%
Power supply| 2×1.5V (battery AAA)
Wireless communication (radio frequency)| 868.3 MHz, <10mW.
Range of approximately150 meters in open field.
Range of approximately 30 meters in residential area.
Internal temperature sensor
External temperature sensor (Option)| NTC 10K at +25°C
Temperature sensor (accuracy)| ± 0.5°C
Regulation| Hysteresis 0,28°C (0.5°F)
Vision® Wireless
wattwater.eu
Watts Electronics S.A.S
B.P. N°10 – Z.A. des Tourettes, 43800 ROSIERES, France,
T: +33(0) 471 57 40 49, F: +33(0) 471 57 40 90,
wattswater.eu
PPLIMW15568Ac/BT-A03-QIG-FR-W-ML-03-23-Rev.1
© 2023 Watts
References
Read User Manual Online (PDF format)