Safety warnings and operating instructions
This product should be installed preferably by a qualified professional. Subject to observation of the above terms, the manufacturer shall assume the liability for the equipment as provided by legal stipulations. All instructions in this Quick Installation Guide should beobserved when working with the controller. Failures dueto improper installation, improper use or poor maintenance are voiding manufacturer liability. Any attempt to repair voids the responsibility and the obligation to guarantee and replacement from the manufacturer.
Contents
Connection
Installation
Dimension
Maximal humidity percentage | 85% at 20°C (68°F) |
---|---|
Electrical protection | Class II with functional earth |
IP protection | IP30 |
Shipping and storage temperature | -10°C to 50°C (14°F to 122°F) |
Power supply | 230 Vac ± 10% 50Hz |
24 Vac ± 10% 50Hz (with transfo
Output maximum load (2 outputs)| Relay: 5A
Actuators| 230V /24V NC/NO up to 2W
Compatibility| BT-A03 RF / BT-D03 RF / BT-DP03 RF / BT-CT02 RF
BT-CT03 RF / WFC-03 HCM RF 230
B.P. N°10 – Z.A. des Tourettes • 43800 ROSIERES • France
Tél. +33 (0)4 71 57 40 49 • Fax. +33 (0)4 71 57 40 90