WATTS Resetting POLD Alarms User Guide

October 30, 2023
WATTS

WATTS Resetting POLD Alarms

Resetting POLD Alarms

(Instructions valid for Control Panel version 6.xx & POLD version 2-3.03)

Step 1: Verify which POLD is alarming

  • The Point of Leak Detector (POLD) that is in alarm will chirp every couple of seconds.
  • If you cannot hear it, check which POLD is in alarm based on its ID number shown at the panel and labeled zone e.g. washing machine, master bathroom, etc.

Step 2: Reset the alarming POLD

  • Locate the reset button inside of the battery compartment.
  • Press firmly and hold the button for 1-3 seconds, then release when chirping stops (or remove and re-insert one battery).

NOTE: For old style mesh cable, if the Water Detection Cable is still wet, you may need to remove the batteries for 24-48 hours until it dries. If the POLD is still going into alarm after being allowed 48 hours to dry, please call Sentinel Hydrosolutions.

\(Instructions valid for Control Panel version 6.xx & POLD version
2-3.03\)

Step 3: Reset the Control Panel

  • Press the RESET button on the control panel. This should leave the red alarm screen. To turn water on (once the leak is dealt with), press the WATER button.
  • If the control panel keeps going back into alarm, check the POLD # in the “Alarm Condition source…” at the top of screen to see if it matches the POLD that was reset. If it is different, repeat Step 1 & Step 2.

NOTE: The alarming sensor must be reset first before the control panel can be reset.

How & When to Change Batteries

How & When to Change Batteries

Step 1: Verify which POLD has a low battery

  • When a POLD has low batteries, it will periodically chirp.
  • This can be verified by tapping on the control panel to wake it up. You will either see a message with the POLD # or you can check the device list. Tap “ADJUST” (or the Droplet character) then “API’s”. Low batteries will be indicated by an orange highlighted number.

NOTE: POLDs out of range of the control panel or with battery levels too low to power the POLD may not show a low battery alert. Batteries should be replaced in regular intervals and after alarms to ensure proper functionality.

Step 2: Replace the batteries

With the antenna facing away from you, the battery that is on the left should have positive(+) facing away from you and toward the yellow dial and the battery that is on the right should have positive(+) facing toward you and away from the reset button — images for correct orientation.

NOTE: Verify that batteries are installed properly by tapping the reset button and ensuring the LED lights up and is solid.

Step 3: Reset the control panel

Simply unplug power from the bottom of the control panel and plug it back in. This should cause a black screen with yellow text to appear after a couple of seconds before returning to the home screen.