INSTRUCTIONS FOR LEVELBEST® DRAINAGE SYSTEM

  1. Deburr, clean and prepare the drain pipe according to industry standards.

  2. Solvent weld the LevelBest® rough-in kit as close to the height of the finished concrete as possible.
    Note: Due to the domed shape of the LevelBest® top, there is no need for artificial marking devices such as whiskers if the drain is close to finished height.

  3. Pour and finish the concrete.

  4. Brush away any loose concrete from the drain area.

  5. Use a meter key or pair of pliers to remove the domed top.

  6. Thread in strainer or cleanout assembly.
    Note: If you are using an all metal strainer assembly, an optional support ring is available. (See chart below for part numbers.)

  7. If the strainer or cleanout assembly is not level with the finished floor, use optional shims to level. These shims can be stacked to adjust for varying degrees of level. Each shim is 1/8” thick. (See chart below for part numbers.)
    Note: Jones Stephens offers decorative grout rings that are compatible with the LevelBest® system. (See chart below for part numbers.)

LevelBest® Accessories

Part No. Description
D50453 Support Ring for 5″ Metal Strainer Assembly
D50466 Support Ring for 6″ Metal Strainer Assembly
D50454 Leveling Shims for 5″ Clean Out / Strainer Assembly
D50459 Leveling Shims for 6″ Clean Out / Strainer Assembly
C60819 Chrome Plated Grout Ring for 5″ Strainer
C60823 Nickel Bronze Grout Ring for 5” Strainer
C60822 Polished Brass Grout Ring for 5” Strainer
C60817 Chrome Plated Grout Ring for 6″ Strainer
C60821 Nickel Bronze Grout Ring for 6” Strainer
C60820 Polished Brass Grout Ring for 6” Strainer

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

JONES STEPHENS User Manuals

Related Manuals