ELSEMA FMR15101240 1 Channel 151MHz FM Receiver with Mains AC Supply User Manual
- June 4, 2024
- ELSEMA
Table of Contents
1-Channel 151MHz Receiver with 16A Relay Output- FMR15101240
FMR15101240
1-Channel 151MHz FM Receiver with mains AC supply
Features
- Supply voltage 110-240VAC
- High capacity output relay
- Pluggable type terminal blocks for easy installation
- Output modes can be selected by the user.
- Also available in IP66 rated case (C1020) for outdoor installations.
Applications
- Pump Control
- Long-distance light control
- On/Off applications in agricultural devices
- Basic Telemetry eg. Water level indication
- Security alarm
Description
This receiver can be connected directly to the mains supply, 110VAC or 240VAC.
The relay output is rated at 8 amps at 240VAC. The relay mode can be set to
momentary, latching, security latching or adjustable timed-off delays.
The user can select 8 different narrow-band frequencies and program an
unlimited number of transmitters to the receiver. With the narrow band FM
151MHz signal from the transmitter a line of sight operating range of 5000
meters is possible. The receiver uses a crystal oscillator circuit that
ensures high-frequency stability allowing optimal performance in the receiving
range.
Connecting wires to the receiver have been made easier by the pluggable type
terminal block. An on board LED indicates when power is connected and the
relay is being activated. The receiver comes with a Quick Mount or in a
weatherproof case with an IP66 rating.
Available with Options
|
---|---
FMR15101240
1- Channel 240VAC Supply| FMR15101240E
1- Channel 240VAC Supply in
an IP66 rated.
Different Modes for the Output
4-Way DIP Switch Mode Settings
The output relay will respond in the following manner when receiving the
correct signal from a transmitter
| Momentary: Relay on, only while correct signal is received
---|---
| Latching: Relay alternates at every correct incoming signal
| Delayed Off 1: Relay on, but delayed off for 1-10 seconds, adjustable by
trimpot
| Delayed Off 2: Relay on, but delayed off for 10-300 seconds, adjustable by
trimpot
| Pulsing: Relay will pulse at 1Hz for 10-300 seconds, adjustable by trimpot
| “Security latching On”: Relay will energize until supply to the receiver is
momentarily interrupted
| “On-Off”: This mode requires a 2-channel Tx. Channel 1 will always energize
the relay Channel 2 will always de-energize the relay
| “Instant OFF ” Same is “Delayed Off ” except relay will switch “OFF” as soon
as the transmitter input is deactivated
| Test: Relay is energized, for test purposes only
Coding
The 12-way dip switch on the receiver sets the 12-bit unique code for the
system. This has to match the transmitter. Do not use the factory default
code.
Apart from the 12-way dip switch, there will be an additional dip switch
depending upon the receiver type:
- The single channel receiver will have a 3-way dip switch.
This DIP switch on the right side of the 12-way dip switch denotes the channel. See the table below.
FMR15101
3-Way DIP Switch & Single Relay Output
8 | NO | NO | NO |
---|---|---|---|
L | 440 | NO | NO |
9 | NO | 440 | NO |
S | 110 | 310 | NO |
17 | NO | NO | 440 |
E | 440 | NO | 440 |
Z | NO | 440 | 440 |
I | 440 | 440 | 440 |
Autumn | C !MS | N MS | E I MS |
Signal Strength Indicator
The 151MHz receivers have green signal strength LED’s on the board. The table
below indicates the level of the valid transmitted signal.
6 LED’s on | -70dBm | Very Strong signal | Very Reliable operating conditions |
---|---|---|---|
5 LED’s on | -75dBm | Very Strong signal | Very Reliable operating conditions |
4 LED’s on | -80dBm | Very Strong signal Ver | Very Reliable operating conditions |
3 LED’s on | -90dBm | Strong signal Ver | Very Reliable operating conditions |
2 LED on | -100dBm | Good signal Re | Reliable operating conditions |
Noise Strength Indicator
If more than 2 led is “ON” without a valid transmission, this indicates that
there is noise on the frequency selected. Change the 3-way dipswitch on the
receiver module to select a different frequency. Following is a table with the
Dipswitch settings and the corresponding frequencies.
Frequency | 1 | 2 | 3 |
---|---|---|---|
151.600 MHz | On | On | On |
152.375 MHz | Off | On | On |
151.775 MHz | On | Off | On |
151.400 MHz | Off | Off | On |
151.175MHz | On | On | Off |
151.025 MHz | Off | On | Off |
150.900 MHz | On | Off | Off |
150.825 MHz | Off | Off | Off |
Technical Data
Supply Voltage | 110 – 240Volts AC Mains |
---|---|
Current Consumption | 18mA at 240V AC |
Receiving Frequency | 151.6MHz (8 selectable frequencies. See table above) |
161MHz for New Zealand 154MHz for the United States of America and Canada
Operating Temperature Range| -5 to 50°C
Connection| Supply & Output – pluggable type terminal blocks
Output| Change over relay output, rated at 16 Amps of resistive load and up to
8 Amps of inductive load
Antenna| 5012, 151MHz Antenna, Elsema ANT151M for maximum performance
Dimensions| 130 x 70 x 37mm
Mounting Hole Size| 3.97111111 or 5/32″
Useable Transmitters| All FMT151 series (with correct frequency setting) refer
to the table above
Useable operating range| Up to 5000 meters, depending on installation and type
of antenna used Recommended Antenna is Elsema s ANT 151 M
Products in the Range
| |
---|---|---
FMR15101 1-Channel| FMR15102 2-Channel| FMR15101240 1- Channel 240VAC Supply
| |
FMR15102240 2- Channel 240VAC Supply| FMR15104 4-Channel| FMR15104240 4-
Channel 240VAC Supply
| |
FMR15108 8-Channel| FMR1510812R 8-Channel, 12V Supply| FMR1510824R 8-Channel,
24V Supply
Block Diagram
The relay output is voltage-free contact
Application Diagram
Elsa Pty Ltd
31 Tarlington Place, Smithfield
NSW 2164, Australia.
Ph: 02 9609 4668
Website: http://www.elsema.com
Distributed by:
Documents / Resources
|
ELSEMA FMR15101240 1 Channel 151MHz FM Receiver with Mains AC
Supply
[pdf] User Manual
FMR15101240, 1 Channel 151MHz FM Receiver with Mains AC Supply, FMR15101240 1
Channel 151MHz FM Receiver with Mains AC Supply, 1 Channel 151MHz FM Receiver,
151MHz FM Receiver, FM Receiver, Receiver
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>