ELSEMA iS900 Axiom Sliding Gate Motor Kit Instruction Manual Product Information

May 15, 2024
ELSEMA

iS900 Axiom Sliding Gate Motor Kit

“`html

Product Information

Specifications

  • Product Name: Axiom Sliding Gate Motor Kit
  • Edition: 4th Edition
  • Models: iS600, iS900
  • Manufacturer: Elsema Pty Ltd
  • Designed for: Australian conditions

Product Usage Instructions

Setup and Installation

  1. Read the user manual carefully before starting the
    installation.

  2. Installation and testing should only be performed by trained
    technical personnel.

  3. Ensure all safety warnings are followed to prevent injury or
    property damage.

Main Menu Structure

  1. To access the main screen, press the Master Control for 2
    seconds.

  2. Navigate through the menu options using the numbered
    sections.

  3. Each section corresponds to a specific function or setting
    related to the gate motor operation.

Features and Accessories

  • The Axiom motor kits come with options to add remote controls
    and other accessories.

  • Standard kits include gear racks, FOB remotes, and Photo
    Electric Beams.

  • Solar kit options are available for eco-friendly
    operation.

FAQ

Q: Can I install the gate motor kit myself?

A: It is recommended to have the installation done by trained
technical personnel to ensure proper setup and minimize risks.

Q: What should I do if the gate motor stops working?

A: Check the power supply, remote control batteries, and ensure
there are no obstructions blocking the gate’s movement. Refer to
the user manual for troubleshooting steps.

“`

Sliding Gate Motor Kit
with Eclipse® Operating System (EOS)

4th Edition
Axiom
iS600/iS900

AXIOM iS600 / iS900

www.elsema.com

Axiom Sliding Gate Motor Kits Setup and Technical Information Includes latest Intelligent Technology

Important warning and safety instructions
All installations and testing must be done only after reading and understanding all instructions carefully. All wiring should be done only by trained technical personnel. Failing to follow instructions and the safety warnings may result in serious injury and/or damage to property.
Elsema Pty Ltd shall not be liable for any injury, damage, cost, expense or any claim whatsoever to any person or property which may result from improper use or installation of this product.
Risk in the goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods.
Any figures or estimates given for performance of goods are based upon the company’s experience and is what the company obtains on tests. The company will not accept liability for failure to comply with the figures or estimates due to the nature of variable conditions affecting for example Radio Remote Controls.
Please keep this setup instruction for future reference.

Installed by: ___

Service date: __

2

Gate & Door Controller with Eclipse® Operating System (EOS)

Contents
Features ……………………………………………………………………………………………………………..4 Description………………………………………………………………………………………………………….4 Part Number………………………………………………………………………………………………………..5 Menu Structure ……………………………………………………………………………………………………6 Connection Diagram …………………………………………………………………………………………….8 Supply and Motor Inputs ………………………………………………………………………………………9 Setup i-Learning Steps………………………………………………………………………………………….9 Menu 1 ­ Auto Close ………………………………………………………………………………………….10 Menu 2 ­ Pedestrian Access Features …………………………………………………………………..11 Menu 3 ­ Input Functions……………………………………………………………………………………12 Menu 4 ­ Photoelectric Beam ………………………………………………………………………………13 Menu 5 ­ Relay Output Functions…………………………………………………………………………14 Menu 6 ­ Relay Output Modes…………………………………………………………………………….17 Menu 7 ­ Special Features…………………………………………………………………………………..19 Menu 8 ­ Motor Obstruction ……………………………………………………………………………….20 Menu 9 ­ Motor Speed and Slow Speed Area…………………………………………………………21 Menu 10 ­ Anti-Jam and Braking …………………………………………………………………………22 Menu 11 ­ i-Learning …………………………………………………………………………………………23 Menu 12 ­ Password ………………………………………………………………………………………….23 Menu 13 ­ Operational Records……………………………………………………………………………23 Menu 14 ­ Tools ………………………………………………………………………………………………..24 Accessories ……………………………………………………………………………………………………….25 PentaFOB® Programming Instructions …………………………………………………………………..27

www.elsema.com

3

Features
) Cost effective solution for domestic sliding gate ) Self learning using intelligent positioning technology ) High capacity Lithium-ion battery backup optional ) All metal gearbox for longer life ) Suitable for gates up to 900Kg ) Contactless limit switch ) Soft start and soft stop ) Easy installation with Eclipse® control card ) Designed by Elsema in Australia
Description
Designed by Elsema, the AXIOM series of automatic gate opener is setting new standards in the automatic gate industry. With Lithium battery backup and all the great features at a competitive price, the AXIOM motor kit is your best choice. Features such as Soft-start, Soft-stop, adjustable anti-crush, inputs for automatic vehicle detection, wireless keypads, safety beams, intercom systems and GSM gate opener, makes it ideal for all domestic and light industrial installations. Lithium-ion batteries have a higher charge/discharge cycle, are smaller in size and has a longer service life when compared with normal lead acid batteries. The AXIOM motor kits are operated by the Eclipse® Operating System (EOS). It is a user friendly menu driven system that uses the 1-touch button to control, setup and run automatic gates, doors and barriers. It uses a large 4-line LCD screen showing live reading of the motor performance and status of all inputs and outputs.
Elsema’s easy options to add remote controls or any other accessory makes for a very user friendly approach, while avoiding the lockdown approach. The Axiom motor kits are designed in Australia for Australian conditions.

4

Gate & Door Controller with Eclipse® Operating System (EOS)

AXIOM SERIES
SLIDING GATE OPENER

ELSEMA INTELLIGENT
®

iS600

iS900
Part Number:

Part No. iS600

Contents

Part No.

Contents

Standard iS600 Kit includes 4metres or gear rack, 3 x FOB remotes and Photo Electric Beam

iS900

Standard iS900 Kit includes 4metres or gear rack, 3 x FOB remotes and Photo Electric Beam

iS900B Standard iS900 Kit with Li-ion Battery Backup Pack

Solar Gates

Solar kit includes iS900 motor, solar MPPT charger iS900Solar24
Li-ion Battery and a 24Volt 40W solar panel.

www.elsema.com

5

Menu Structure
MAIN SCREEN

Press Master Control for 2 seconds to enter the menu structure

1.0 Auto Close
2.0 Pedestrian Access
3.0 Input Functions
4.0 PE Safety Beam Function
5.0 Output Functions
6.0 Output Modes

1.1 Auto Close Time
2.1 PA Travel Time
3.1 PE Polarity
4.1 Stop & Open on Close Cycle
5.1 Relay Output 1
Lock / Brake
Courtesy Light
Service Call
Strobe (Warning) Light
6.1 Lock Output
6.1.1: Open Lock Activation
6.1.2: Close Lock Activation
6.1.3: Pre-Open Lock
6.1.4: Pre-Close Lock
6.1.5: EXIT

1.2 AC Time with PE Trig
2.2 PA AC Time
3.2 Limit Sw Polarity
PE Beam Stops Motor on Close Cycle
5.2 Relay Output 2
Lock / Brake
Courtesy Light
Service Call
Strobe (Warning) Light
6.2 Light Output
6.2.1: Courtesy Light
6.2.2: EXIT

7.0 Special Features
8.0 Motor Obstruct Detect Margin
9.0 Motor Speed, Slow Speed Area & Reverse Time
10.0 Anti-Jam / Electronic Braking
11.0 Travel Learn
12.0 Password
13.0 Operational Records
14.0 Tools
EXIT PROGRAMMING

7.1 RC Open only
8.1 Open Obstruct
9.1 Open Speed (%)
10.1 Open Anti-Jam

7.2 Holiday Mode
8.2 Close Obstruct
9.2 Close Speed (%)
10.2 Close Anti-Jam

12.1 Enter Password
13.1 Events History
14.1 Battery Type

12.2 Delete Password
13.2 Display Operations / Currents
14.2 Supply Voltage

6

Gate & Door Controller with Eclipse® Operating System (EOS)

1.3

1.4

1.5

1.6

1.7

AC After Open Obstruct

AC After Power Restored

AC on Seq. Obstruct

AC Only When Fully Open

EXIT

2.3

2.4

2.5

2.6

PA AC Time with PE Trig

PA AC on Seq. Obstruct

PA Hold Gate

EXIT

3.3

3.4

Stop Input Polarity

EXIT

PE Beam Stops Motor

PE Beam Stops Motor and

4.2

on Open & Close Cycle

Closes on Open Cycle

EXIT

5.3 EXIT

6.3

6.4

6.5

Strobe (Warning) Light

Service Call

EXIT

6.3.1: Pre-Open Warning Light

6.4.1: Service Counters

6.3.2: Pre-Close Warning Light

6.4.2: EXIT

6.3.3: EXIT

7.3 Energy Saving
8.3 Slow Speed Obstruct
9.3 Slow Speed (%)
10.3 Electronic Braking

7.4 Automatic Stop/Open on Closing
8.4 Obstruct Det Response
9.4 Open Slow Speed Area
10.4 Open Obstruction Operation

7.5 Receiver Channel 2 Options
8.5 EXIT
9.5 Close Slow Speed Area
10.5 Close Obstruction Operation

7.6 Press and Hold, Open Input
9.6 Stop Rev Delay Time
10.6 EXIT

7.13 Exit
7.12 Stop Input Function
7.11 Press and Hold, Remote Ch2
7.10 Press and Hold, Remote Ch1
7.9 Reserved
7.8 Window / Louvre Mode
7.7 Press and Hold, Close Input
9.7 EXIT

12.3 EXIT
13.3 Reset Max Current Records
14.3 Reset Factory Default

13.4 EXIT
14.4 Test Inputs

14.5 Travel Timer for Slip Motors

14.6 Solar Gate Mode
14.9 Exit

14.7 Fuse Type : 10 or 15 Amps
14.8 Slow Speed Ramp Down

www.elsema.com

7

Powered By
Eclipse operating system
2
+ –

Normally Open Normally Closed User can change User can change

Connection Diagram
AACCSSupppplyly AACCSSupppplyly
AMCoStuoprply AMCoStuoprply
BACatStueprpyly+ BACatStueprpyly-
Push Button
Open Common
Close Stop Common
PED Access Photo Beam
Common + 12 VDC – 12 VDC Output 1 C
Output 1 NO Output 1 NC

Fuse
Relay

Built-in Receiver Master Control
Open Close Stop

Program 2
Program 1
Antenna 1 Shield
Antenna 2

Output 2 Used with Relay 1-12
Limit Switch

Output Rated at 250mA

8

Gate & Door Controller with Eclipse® Operating System (EOS)

Electrical Wiring – Supply, Motors and Inputs
Always switch off power before doing any wiring. Make sure that all the wiring is completed and that the motor is connected to the control card. Recommended wire strip length should be 12mm for all connections to the plug in terminal blocks.
The diagram below shows the supply, motors, and inputs available and the factory default setting for each input.

Fuse
Relay

ELSEMA
+ –

Master Control
Open Close Stop

AACCSSuppplplyy AACCSSuppplplyy
AMCoStuoprply AMCoStuoprply ABCatStueprpyly+ ABCatStueprpyly-
Push Button
Open Common
Close Stop Common
PED Access Photo Beam
Common + 12 VDC – 12 VDC Output 1 C
Output 1 NO Output 1 NC

Output Rated at 250mA
Normally Open Normally Closed User can change User can change
Setup i-Learning Steps:
1. The i-Learning setup can always be interrupted with the stop button or by pressing the Master Control knob.
2. Enter Menu 11 to start i-Learning or new control cards will automatically prompt you to do the i-Learning. 3. Look at the LCD and follow the instructions displayed. 4. Buzzer will indicate learning was successful. If there was no buzzer check all electrical wiring including the
power supply then go back to step 1. 5. If you hear the buzzer after the i-Learn, the gate or door is ready for use.

www.elsema.com

9

Menu 1 ­ Auto Close

Auto Close is a feature that automatically closes the gate after a preset time has counted down to zero. The control card has a normal Auto Close and several special Auto Close features each one having its own countdown timers.
Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used.
If the Stop input is activated Auto Close is disabled for that cycle only.
Auto Close timer will not count down if the Push Button, Open or Photoelectric Beam input is held active.

Menu No.

Auto Close Features

Factory Default

Adjustable

1.1

Normal Auto Close

Off

1 – 600 seconds

1.2

Auto Close with Photoelectric Trigger

Off

1 – 60 seconds

1.3

Auto Close after an Open Obstruction

Off

1 – 60 seconds

1.4

Auto Close after Power Restored

1.5

Normal Auto Close on Sequential Obstructions

1.6

Auto Close Only when Fully Opened

Off

1 – 60 seconds

Min = Off, 2
Max = 5

Off

Off/On

1.7

Exit

1.1 Normal Auto Close The gate will close after this timer has counted down to zero.
1.2 Auto Close with Photoelectric Trigger This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger even if the gate is not fully open. If there is no Photoelectric Beam trigger the gate will not Auto Close.
1.3 Auto Close after an Open Obstruction If the gate opens and hits an obstruction normally the gate will stop and remain in this position. If this feature is enabled an obstruction will start the timer count down and at zero will close the gate.

10

Gate & Door Controller with Eclipse® Operating System (EOS)

1.4 Auto Close after Power Restored If the gate is open in any position and then there is a power failure, when power is reconnected the gate will close with this timer.
1.5 Normal Auto Close on Sequential Obstructions If the normal Auto Close is set and the gate closes onto an object the gate will stop and reopen. This setting sets the amount of times the gate will try to Auto Close. After trying for the set limit the gate will remain open.
1.6 Auto Close Only when Fully Opened The Auto Close timer will not time out unless the gate is fully open.

Menu 2 ­ Pedestrian Access

There are several types of Pedestrian Access modes. Pedestrian Access opens the gate for a short time to allow someone to walk through the gate but does not allow access to a vehicle.
Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used.

Menu No.

Pedestrian Access Features

Factory Default

Adjustable

2.1

Pedestrian Access Travel Time

3 seconds

3 – 20 seconds

2.2

Pedestrian Access Auto Close Time

Off

1 – 60 seconds

2.3

Pedestrian Access Auto Close Time with PE trigger

Off

2.4

Pedestrian Access Auto Close on Sequential Obstructions

2

2.5

Pedestrian Access with Hold Gate

Off

1 – 60 seconds
Min = Off, Max = 5
Off/On

2.6

Exit

www.elsema.com

11

2.1 Pedestrian Access Travel Time This sets the time the gate opens when a Pedestrian Access input is activated.
2.2 Pedestrian Access Auto Close Time This sets the countdown timer for automatically closing the gate when a Pedestrian Access input is activated.
2.3 Pedestrian Access Auto Close Time with PE Trigger This Auto Close starts counting down as soon as the Photoelectric Beam has been cleared after a trigger, when the gate is in the Pedestrian Access position. If there is no Photoelectric Beam trigger the gate will remain in Pedestrian Access position.
2.4 Pedestrian Access Auto Close on Sequential Obstructions If the Pedestrian Access Auto Close is set and the gate closes onto an object the gate will stop and reopen. This setting sets the amount of times the gate will try to Auto Close. After trying for the set limit the gate will remain open. When turned OFF, the gate will always try to Auto Close.
2.5 Pedestrian Access with Hold Gate If the Pedestrian Access hold gate is ON and the Pedestrian Access input is permanently activated the gate will remain open in the Pedestrian Access position. Open input, Close input, Push Button input and remote controls are disable. Used in Fire Exit applications.

Menu 3 ­ Input Functions

This allows you to change the polarity of Photoelectric Beam, Limit Switch and Stop inputs.

Menu No. 3.1

Input Functions Photoelectric Beam Polarity

Factory Default

Adjustable

Normally Closed

Normally Closed / Normally Open

3.2

Limit Switch Polarity

Normally Closed

Normally Closed / Normally Open

3.3

Stop Input Polarity

Normally Open

Normally Closed / Normally Open

3.4

Exit

12

Gate & Door Controller with Eclipse® Operating System (EOS)

Menu 4 ­ Photoelectric Beam

The Photoelectric Beam or sensor is a safety device which is placed across the gate and when the beam is obstructed it stops a moving gate. The operation after the gate stops can be selected in this menu.

Menu No.

Photoelectric Beam Feature

Factory Default

4.1

Photoelectric Beam

PE Beam stops and opens gate on close cycle

Adjustable
PE Beam stops and opens gate on close cycle
———————————–PE Beam stops gate on close cycle
———————————–PE Beam stops gate on open & close cycle
———————————–PE Beam stops and closes gate on open cycle

4.2

Exit

The factory default for the PE beam input is “normally closed” but this can be changed to normally open in Menu 3.1.
Elsema Pty Ltd recommends a Photoelectric Beam to be connected to the control card when any of the Auto Close options are used.
Elsema sells different types of Photoelectric Beams. We stock Retro-Reflective and Through Beam type Photoelectric Beams.

PE1500
(Polarised Retro-Reflective Type)
www.elsema.com

PE24
(Through-Beam type)
13

Menu 5 ­ Output Functions
The control card has two outputs, Output 1 and Output 2. The user can change the function of these outputs to lock / brake, courtesy light, service call, strobe (Warning) light or gate open (gate not fully closed) indicator.
Output 1 is a relay output with common and normally open contacts. Factory default is lock / brake release function.
Output 2 is an open collector output. Factory default is courtesy light function.

Menu No.

Output Function

Factory Default

5.1

Output 1

Lock / Brake

5.2

Output 2

Courtesy Light

5.3

Exit

Adjustable
Lock / Brake ————————————
Courtesy Light ————————————
Service Call ————————————
Strobe (Warning) Light ————————————
Gate Open
Lock / Brake ————————————
Courtesy Light ————————————
Service Call ————————————
Strobe (Warning) Light ————————————
Gate Open

14

Gate & Door Controller with Eclipse® Operating System (EOS)

Lock / Brake Output
The factory default for output 1 is lock/ brake release. Output 1 is a voltage-free relay contact with common and normally open contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC to the common. The normally open contact powers the device. See diagram below:

Open Close Stop

Relay

Output 1 C Output 1 NC

Power +
Supply –

12VDC output supply from the card is limited to 250mA. It cannot supply locks or other loads which draw more than 250mA.

Magnetic Lock

Courtesy Light
The factory default for the courtesy light is on output 2. Output 2 is an open collector output. This output is used to switch an external relay such as Elsema’s REL12-1 which can be purchased separately. See diagram on the next page.

www.elsema.com

15

Master Control

Output 2

Stop

Relay

REL12-1 available separately

REL12-1

Output NC Output C Output NO

Service Call Output
Either output 1 or output 2 can be changed to service call indicator. This will trigger the output when the software service counter is reached. Used to alert installers or owners when the gate is to be serviced. Using Elsema’s GSM receiver allows installers or owners to get a SMS message and a call when the service is due.
Strobe (Warning) Light when Opening or Closing
The relay output is activated whenever the gate is operating. The factory default is Off. Either output 1 or output 2 can be changed to strobe (Warning) light.
Gate Open
The relay output is activated whenever the gate is not fully closed. The factory default is Off. Either output 1 or output 2 can be changed to gate open.

16

Gate & Door Controller with Eclipse® Operating System (EOS)

Menu 6 ­ Relay Output Modes

Menu 6.1 ­ Lock / Brake Output Modes
The relay output in the lock / brake mode can be configured in different ways.

Menu No.

Lock / Brake Modes

6.1.1

Open Lock / Brake Activation

6.1.2

Close Lock / Brake Activation

6.1.3

Open Pre-Lock / Brake Activation

6.1.4

Close Pre-Lock / Brake Activation

Factory Default 2 seconds
Off Off Off

Adjustable
1 ­ 30 seconds or hold
1 ­ 30 seconds or hold
1 ­ 30 seconds
1 ­ 30 seconds

6.1.5

Exit

6.1.1 Open Lock / Brake Activation This sets the time the output is activated in the open direction. Factory default is 2 seconds. Setting it to Hold means the output is activated for the total travel time in the open direction.
6.1.2 Close Lock / Brake Activation This sets the time the output is activated in the close direction. Factory default is off. Setting it to Hold means the output is activated for the total travel time in the close direction.

6.1.3 Open Pre-Lock / Brake Activation This sets the time the output is activated before the motor starts in the open direction. Factory default is Off.
6.1.4 Close Pre-Lock / Brake Activation This sets the time the output is activated before the motor starts in the close direction. Factory default is Off.

Menu 6.2 ­ Courtesy Light Output Mode

The relay output in the courtesy mode can be adjusted from 30 to 300 seconds. This sets the time the courtesy light is activated. Factory default is 60 seconds.

Menu No. 6.2.1

Courtesy Light Mode Courtesy Light Activation

Factory Default
60 seconds

Adjustable 30-300 seconds

6.2.2

Exit

www.elsema.com

17

Menu 6.3 ­ Strobe (Warning) Light Output Mode

The relay output in the strobe (Warning) mode can be configured in different ways:

Menu No. Strobe (Warning) Light Mode

6.3.1

Pre-Open Strobe (Warning) Light Activation

6.3.2

Pre-Close Strobe (Warning) Light Activation

Factory Default
Off
Off

Adjustable 1 ­ 30 seconds 1 ­ 30 seconds

6.3.3

Exit

6.3.1 Pre-Open Strobe Light Activation This sets the time the strobe light is activated before the gate operates in the open direction. Factory default is Off.
6.3.2 Pre-Close Strobe Light Activation This sets the time the strobe light is activated before the gate operates in the close direction. Factory default is Off.

Menu 6.4 ­ Service Call Output Mode
This sets the number of complete cycles (Open and Close) required before the built-in buzzer is activated. Also the control card outputs can be configured to be activated if the number of cycles is completed. Connecting Elsema’s GSM receiver to the output allows owners to get a phone call & SMS message when the service is due.
When “Service Call Due” message shows up on the LCD a service call is required. After service has been done, follow the messages on the LCD.

Menu No. 6.4.1

Service Call Mode Service Counter

Factory Default
Off

Adjustable Min: 2000 to Max: 50,000

6.4.2

Exit

18

Gate & Door Controller with Eclipse® Operating System (EOS)

Menu 7 ­ Special Features
The control card has many special features that can all be customised to your specific application.

Menu No.
7.1 7.2 7.3 7.4 7.5 7.6 7.7 7.8 7.9 7.10 7.11 7.12 7.13

Special Features
Remote Control Open Only Holiday Mode
Energy Saving Mode Automatic Stop & Open on Closing
Receiver Channel 2 Options Press and Hold for Open Input Press and Hold for Close Input
Window / Louvre Reserved
Press & Hold Remote Channel 1 (Open) Press & Hold Remote Channel 2 (Close)
Stop Input Function Exit

Factory Default

Adjustable

Off Off Off On Off Off Off Off Reserved Off Off Stop

Off / On Off / On Off / On Off / On Off / Light / Pedestrian Access / Close Only Off / On Off / On Off / On Reserved Off / On Off / On Stop / Stop & Reverse for 1 sec

7.1 Remote Control Open Only By default the remote control allows the user to open and close the gate. In public access areas user should only be able to open the gate and not worry about closing it. Usually the Auto Close is used to close the gate. This mode disables closing for the remote controls.
7.2 Holiday Mode This feature disables all the remote controls.
7.3 Energy Saving Mode This puts the control card to very low standby current that reduces your electricity bill while still maintaining normal functions and operations.
7.4 Automatic Stop & Open on Closing By default when the gate is closing and a push button or remote control is activated it will automatically stop and open the gate. When this feature is disabled, the gate will only stop. Automatic opening will be disabled.
7.5 Receiver Channel 2 Options The receivers 2nd channel can be programmed to control a courtesy light, pedestrian access or can be used for close only.

www.elsema.com

19

7.6 & 7.7 Press and Hold for Open and Close Inputs If this feature is ON the user must continuously press the open or close input for it to be activated.
7.8 Window or Louvre Mode This mode optimises the control card for operating electronic windows or louvres.
7.10 & 7.11 Press and Hold for Remote Channel 1 (Open) and Channel 2 (Close) The remote channel 1 & 2 buttons will need to be programmed to receiver channel 1 & 2. The user must continuously press the remote button for the gate to open or close. The gates will stop as soon as the buttons are released.
7.12 Stop Input Function The stop input can be set to either Stop the gate or Stop & Reverse the gate for 1 second.

Menu 8 ­ Obstruction Detect Margins
This sets the current sensitivity margin above the normal run current to trip the gate if an obstruction is detected. Different obstruction margins and response time can be set for the open and close direction.
The minimum margin will allow least pressure applied to trip the gate if it hits an object.

Menu No. 8.1 8.2 8.3 8.4

Obstruction Detect Margins and Response Time
Open Obstruction Margin
Close Obstruction Margin
Open and Close Slow Speed Obstruction Margin
Obstruction Detect Response Time

Factory Default 1 Amp 1 Amp 1 Amp

Adjustable 0.2 – 6.0 Amps 0.2 – 6.0 Amps 0.2 – 6.0 Amps

Medium

Fast, Medium, Slow and Very Slow

8.5

Exit

Margin Example Motor is running at 2 Amps and the margin is set to 1.5 Amps, an obstruction detect will occur at 3.5 Amps (Normal Running Current + Margin).
For high margin settings, the supply transformer should be large enough to supply the high margin current.
If the gate hits an object on closing it will automatically stop and then re- open. If the gate hits an object on opening it will automatically stop.

20

Gate & Door Controller with Eclipse® Operating System (EOS)

Menu 9 ­ Motor Speed, Slow Speed Area and Reverse Time

Menu No.

Motor Speed, Slow Speed Area and Reverse Time

9.1

Open Speed

Factory Default
80%

9.2

Close Speed

70%

9.3

Open and Close Slow Speed

50%

9.4

Open Slow Speed Area

4

9.5

Close Slow Speed Area

5

9.6

Stop Reverse Delay

0.4 seconds

9.7

Exit

Adjustable 50% to 125% 50% to 125% 25% to 65%
1 to 12 1 to 12 0.2 to 2.5 seconds

After changing open speed, close speed or slow speed, i-Learn has to be done again.

9.1 & 9.2 Open and Close Speed This sets the speed at which the gate will travel. If the gate is travelling too fast reduce this value.
9.3 Slow Speed This sets the speed at which the gate will travel in the slow speed region. If the gate is travelling too slow increase this value.
9.4 & 9.5 Slow Speed Area This sets the slow speed travel area. If you want more travel time for the slow speed area increase this value.
9.6 Obstruction Stop Reverse Delay Time This sets the stop and reverse delay time when the gate hits an obstruction.

www.elsema.com

21

Menu 10 ­ Anti-Jam, Electronic Braking and Gate Movement after Obstruction

Menu No. 10.1

Anti-Jam or Electronic Braking
Open Anti-Jam

10.2

Close Anti-Jam

10.3

Electronic Braking

10.4

Gate Movement after Obstruction in Opening Direction

10.5

Gate Movement after Obstruction in Closing Direction

10.6

Exit

Factory Default
OFF

Adjustable 0.1 to 2.0 seconds

OFF

0.1 to 2.0 seconds

OFF

Off/On

Stop
Reverse for 2 seconds

Stop / Reverse for 2 sec / Reverse Fully
Stop / Reverse for 2 sec / Reverse Fully

10.1 and 10.2 Motor Open and Close Anti-Jam When the gate are in the fully open or fully closed position this feature applies a reverse voltage for a very short time. It will prevent the motor from jamming up the gate so it is easy to disengage the motors for manual operation.
10.3 Electronic Braking This will stop the motors with an electronic brake. Brake is applied when an obstruction is detected or when the Stop input is triggered.
10.4 Opening Direction : Gate Movement after Obstruction After an obstruction has occurred in the opening direction, the gate will either stop, reverse for 2 seconds or reverse fully.
10.5 Closing Direction : Gate Movement after Obstruction After an obstruction has occurred in the close direction, the gate will either stop, reverse for 2 seconds or reverse fully.

22

Gate & Door Controller with Eclipse® Operating System (EOS)

Menu 11 ­ i-Learning
This feature allows you to do the intelligent travel learning of the gate. Follow the messages on the LCD to complete the learning.
Menu 12 ­ Password
This will allow the user to enter a password to prevent unauthorised users from entering the control card settings. User must remember the password. The only way to reset a lost password is to send the control card back to Elsema. To delete a password select Menu 12.2 and press Master Control.

Menu 13 ­ Operational Records
This is for information only.

Menu No. 13.1 13.2 13.3 13.4

Operational Records Event History, up to 100 events are recorded in the memory
Displays Gate Operations and Currents Levels Reset Maximum Current Records Exit

13.1 Event History The event history will store 100 events. The following events are recorded into the memory: Power On, Low Battery, All input activations, Successful Opening, Successful Closing, Obstruction Detected, Unsuccessful i-Learning Attempt, Factory Reset, DC Output Overloaded, AC Supply Failed, AC Supply Restored, Auto Close, Security Close and Fuse Protect Obstruction.

13.2 Displays Gate Operations and Current Levels This displays the number of open cycles, close cycles, pedestrian cycles, open obstructions, close obstructions and motor current levels. All maximum current values can be reset by the user from Menu 13.3.

www.elsema.com

23

Menu 14 ­ Tools

Menu No. 14.1 14.2 14.3 14.4 14.5 14.6
14.7
14.8 14.9

Tools Battery Type : Lithium-ion Set the Supply Voltage : 12 or 24 Volts Resets Controller to Factory Settings
Test Inputs Travel Timer for Slip Clutch Motors Solar Gate Mode : Optimises the Control Card for Solar Applications
Fuse Type : 10 or 15 Amps Optimises the Control Card for the correct Blade Fuse used
Slow Speed Ramp Down Time Exit

14.1 Battery Type The iS900B motor kit is with Lithium-ion battery backup. Only use Lithium-ion batteries supplied by Elsema. Part number Li7800.
14.2 Set the Supply Voltage The control card automatically sets the supply voltage during setup. This option allows you to manually set the control card to 12 or 24 Volt supply. To use the control card in a solar application you must set the correct voltage in the Tools. This will disable the automatic voltage sensing which could causes problems in solar applications.
14.3 Resets Controller Reset all settings to factory default. Also removes password.
14.4 Test Inputs This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means input is activated and lowercase means input is activated.
14.5 Travel Timer for Slip Clutch Motors This allows you to use the controller with travel time. Used for Slip clutch or Hydraulic Motors
14.8 Slow Speed Ramp Down Time This allows you to change the time it takes the gate to change its speed from fast to slow.

24

Gate & Door Controller with Eclipse® Operating System (EOS)

Accessories
Solar Applications For solar use the iS900Solar24
Pre-made Inductive Loops & Loop Detectors Elsema has a range of Saw-Cut and Direct Burial loops. They are pre-formed with recommended loop sizes for commercial or domestic applications and makes installation quick and easy.
Wireless Bump Strip Safety edge bump strip is installed on the moving gate or barrier along with the transmitter. When the gate hits an obstacle, the transmitter transmits a wireless signal to the receiver to stop the gate from causing further damage.
Flashing Lights Elsema has several flashing lights to act as a warning when the gate or doors is in operation.
Electromagnetic Locks Waterproof magnetic lock for electronic sliding and swing gates. 12 or 24 Volts DC supply can be used. The lock is magnetised when voltage is applied.

Inductive Loop

Loop Detectors

Safety Bump Strip Flashing Lights

Magnetic Locks

www.elsema.com

25

Keyring Remotes The latest PentaFOB® keyring remotes ensure your gates or doors are secure. Visit www.elsema.com for more details.
PentaFOB® Remotes

PentaFOB® Programmer
Add, edit and delete PentaFOB® remotes from the receiver’s memory. The receiver can also be password protected from unauthorised access.

PentaFOB® Programmer

Booster for PentaFOB® remotes
Penta Repeater can increase the operating range of the keyring remotes to up to 500 metres.

Repeater/ booster for PentaFOB® remotes

26

Gate & Door Controller with Eclipse® Operating System (EOS)

PentaFOB® Programming Instructions
1. Press and hold the program button on the built-in receiver (Refer to the iS connection diagram) 2. Press the remote button for 2 seconds while holding the program button on the receiver 3. Receiver LED will flash and then turn Green 4. Release the button on the receiver 5. Press remote control button to test the receiver output
Deleting Receivers Memory Short the Code Reset pins on the receiver for 10 seconds. This will delete all the remotes from the receiver’s memory.
PentaFOB® Programmer This programmer allows you to add and delete certain remotes from the receiver memory. This is used when a remote control is lost or a tenant moves from the premises and the owner wants to prevent un- authorised access.
PentaFOB® Backup Chips This chip is used to backup or restore the contents of a receiver. When there are 100’s of remotes programmed to a receiver the installer normally backups the receiver memory in case the receiver is damaged.

www.elsema.com

27

LCD Display Explained
Gate Status

Input Status

Limit Switch Status

Gate Status Gate Opened Gate Closed Gate Stopped Obstruction Detected
Limit Switch Status M1OpnLmON M1ClsLmON
Input Status Opn ON Cls ON Stp ON PE ON PB ON PED ON

Description Gate is in the fully open position Gate is in the fully close position Gate has been stopped by either one of the inputs or remote control Control card has sensed an obstruction
Description Motor 1 Open limit switch is ON Motor 1 Close limit switch is ON
Description Open input is activated Close input is activated Stop input is activated Photo Beam input is activated Push Button input is activated Pedestrian Access input is activated

28

Gate & Door Controller with Eclipse® Operating System (EOS)

Troubleshooting Guide
During i-Learn, the gate will open and close 3 times. First cycle is in slow speed. The second cycle is in fast speed. The third cycle will be in fast speed but the gate will slow down before reaching the end.

Error during i-Learn
i-Learn is stuck at 14% i-Learn is stuck at 28%
Gate does not fully open or fully close in the 1st i-Learn cycle
Gate does not fully open or fully close in the 2nd i-Learn cycle

Remedy
Decrease M1 Slow Speed Obstruction Margin (Menu 8.3) Decrease M1 Open Obstruction Margin (Menu 8.1)
Increase M1 Slow Speed Obstruction Margin (Menu 8.3)
Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2)

Limit switch failed to register and the gate is not in the fully open or closed
position.

For 1st cycle. Increase M1 Slow Speed Obstruction Margin (Menu 8.3). For 2nd & 3rd cycle. Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2)

Limit switch failed to register and the gate is in the fully open or closed
position.

Limit switch position is not correct. The gate has reached the physical stopper before the limit switch is activated.

Error during Operation
Gate does not fully open or fully close but the LCD says “Gate Opened” or
“Gate Closed”.

Remedy
Increase M1 Slow Speed Obstruction Margin (Menu 8.3)

LCD says “Obstruction detected” when there is no obstruction.

Increase M1 Open or Close Obstruction Margin (Menu 8.1 & 8.2)

Gate does not respond to remotes or any local trigger.

Check the LCD for Input status (see previous page). If any input is activated and held active, the card will not respond to any other command.

www.elsema.com

29

Sliding gate motor kits

Keyring remote controls

Swinging gate motor kits

Sliding gate motor kits

Swinging gate motor kits

Motor control cards & Kits

ELSEMA PTY LTD
31 Tarlington Place Smithfield NSW 2164 Australia
P 02 9609 4668 W www.elsema.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELSEMA User Manuals

Related Manuals