NATIONAL INSTRUMENTS NI 66xx Pinout Labels for the SCB-68 Instruction Manual
- October 30, 2023
- NATIONAL INSTRUMENTS
Table of Contents
NOTE TO USERS
NI 66xx Pinout Labels for the
SCB-68
Instruction Manual
NI 66xx Pinout Labels for the SCB-68
Counter/Timer Modules/Devices Using the 68-Pin Shielded Connector Block
If you are using an NI 66xx (formerly referred to as TIO) counter/timer device
or module with the SCB-68, you can print and attach a connector-specific
pinout label to the cover of the connector block for easy connection
reference. This document provides labels for the following models:
- NI 6601
- NI 6602
- NI 6608
- NI 6612
- NI 6614
Use the following label if you are connecting the SCB-68 to NI 6601, NI 6602, and NI 6608 models.
SCB-68 Quick Reference Label
NI 660x Counter/Timer (TIO) Models
DIO/CTR | DIO/CTR | DIO/CTR |
---|
68 D GND
34 PFI 31/P0.31/CTR 2 SOURCE
67 PFI 30/P0.30/CTR 2 GATE
33 D GND
66 PFI 29/P0.29/CTR 2 AUX
32 PFI 28/P0.28/CTR 2 OUT
65 D GND
31 PFI 27/P0.27/CTR 3 SOURCE
64 PFI 26/P0.26/CTR 3 GATE
30 D GND
63 PFI 25/P0.25/CTR 3 AUX
29 PFI 24/P0.24/CTR 3 OUT
62 D GND
28 PFI 23/P0.23/CTR 4 SOURCE
61 PFI 22/P0.22/CTR 4 GATE
27 D GND
60 PFI 21/P0.21/CTR 4 AUX
26 PFI 20/P0.20/CTR 4 OUT
59 D GND
25 PFI 19/P0.19/CTR 5 SOURCE
58 PFI 18/P0.18/CTR 5 GATE
24 D GND
57 PFI 17/P0.17/CTR 5 AUX
23 PFI 16/P0.16/CTR 5 OUT| 12 PFI 3/P0.3
46 D GND
13 PFI 4/P0.4
47 PFI 5/P0.5
14 D GND
48 PFI 6/P0.6
15 PFI 7/P0.7
49 D GND
16 PFI 8/P0.8/CTR 7 OUT
50 D GND
17 PFI 9/P0.9/CTR 7 AUX
51 PFI 10/PO.10/CTR 7 GATE
18 D GND
52 PFI 11/P0.11/CTR 7 SOURCE
19 R GND
53 PFI 12/PO.12/CTR 6 OUT
20 D GND
54 PFI 13/P0.13/CTR 6 AUX
21 PFI 14/P0.14/CTR 6 GATE
55 D GND
22 PFI 15/P0.15/CTR 6 SOURCE
56 R GND| 1 +5 V
35 R GND
2 PFI 39/CTR 0 SOURCE
36 D GND
3 PFI 38/CTR 0 GATE
37 RESERVED
4 RESERVED
38 RESERVED
5 PFI 36/CTR 0 OUT
39 D GND
6 PFI 33/CTR 1 AUX
40 PFI 37/CTR 0 AUX
7 PFI 35/CTR 1 SOURCE
41 D GND
8 PFI 34/CTR 1 GATE
42 D GND
9 PFI 32/CTR 1 OUT
43 R GND
10 PFI 0/P0.0
44 PFI 1/P0.1
11 D GND
45 PFI 2/P0.2
R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable.
Use the following label if you are connecting the SCB-68 to NI 6612 and NI
6614 models.
Figure 2. NI 661x
SCB-68 Quick Reference Label
NI 661x Counter/Timer (TIO) Models
DIO/CTR | DIO/CTR | DIO/CTR |
---|
68 D GND
34 PFI 31/P0.31/CTR 2 SOURCE
67 PFI 30/P0.30/CTR 2 GATE
33 D GND
66 PFI 29/P0.29/CTR 2 AUX
32 PFI 28/P0.28/CTR 2 OUT
65 D GND
31 PFI 27/P0.27/CTR 3 SOURCE
64 PFI 26/P0.26/CTR 3 GATE
30 D GND
63 PFI 25/P0.25/CTR 3 AUX
29 PFI 24/P0.24/CTR 3 OUT
62 D GND
28 PFI 23/P0.23/CTR 4 SOURCE
61 PFI 22/P0.22/CTR 4 GATE
27 D GND
60 PFI 21/P0.21/CTR 4 AUX
26 PFI 20/P0.20/CTR 4 OUT
59 D GND
25 PFI 19/P0.19/CTR 5 SOURCE
58 PFI 18/P0.18/CTR 5 GATE
24 D GND
57 PFI 17/P0.17/CTR 5 AUX
23 PFI 16/P0.16/CTR 5 OUT| 12 PFI 3/P0.3
46 D GND
13 PFI 4/P0.4
47 PFI 5/P0.5
14 D GND
48 PFI 6/P0.6
15 PFI 7/P0.7
49 D GND
16 PFI 8/P0.8/CTR 7 OUT
50 D GND
17 PFI 9/P0.9/CTR 7 AUX
51 PFI 10/PO.10/CTR 7 GATE
18 D GND
52 PFI 11/P0.11/CTR 7 SOURCE
19 R GND
53 PFI 12/PO.12/CTR 6 OUT
20 D GND
54 PFI 13/P0.13/CTR 6 AUX
21 PFI 14/P0.14/CTR 6 GATE
55 D GND
22 PFI 15/P0.15/CTR 6 SOURCE
56 R GND| 1 +5 V
35 R GND
2 PFI 39/P1.7/CTR 0 SOURCE
36 D GND
3 PFI 38/P1.6/CTR 0 GATE
37 RESERVED
4 RESERVED
38 RESERVED
5 PFI 36/P1.4/CTR 0 OUT
39 D GND
6 PFI 33/P1.1/CTR 1 AUX
40 PFI 37/P1.6/CTR 0 AUX
7 PFI 35/P1.3/CTR 1 SOURCE
41 D GND
8 PFI 34/P1.2/CTR 1 GATE
42 D GND
9 PFI 32/P1.0/CTR 1 OUT
43 R GND
10 PFI 0/P0.0
44 PFI 1/P0.1
11 D GND
45 PFI 2/P0.2
R GND: These terminals are routed to RESERVED when using the product with a SH68-68-D1 shielded cable or routed to D GND when using the product with a R68-68 ribbon cable.
Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for more information on NI trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering NI products/technology, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your media, or the National Instruments Patents Notice at ni.com/patents. You can find information about end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the NI global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.
COMPREHENSIVE SERVICES
We offer cdmpetitive repair and calibration services, as well as easily
accessible documentation and free downloadable resources.
SELL YOU SUPLUS
We buy new, used, decommissioned, and surplus parts from every NI series.
We work out the best solution to suit your individual needs.
Sell For Cash
Get Credit
Receive a Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
Bridging the gap between the manufacturer and your legacy test system.
**** 1-800-915-6216
www.apexwaves.com
sales@apexwaves.com
Alltrademarks,brands, and brand names are theproperty of their espective
owners:
Request a Quote CLICK HERE
PCle-6612
© 2018 National Instruments. All rights reserved.
References
- Engineer Ambitiously - NI
- Trade Compliance - NI
- National Instruments Patents - NI
- NI Trademarks and Logo Guidelines - NI
- PCIe-6612 National Instruments Counter/Timer Device | Apex Waves
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>