NATIONAL INSTRUMENTS PXIe-6396 Multifunction Input or Output Module User Guide
- October 30, 2023
- NATIONAL INSTRUMENTS
Table of Contents
PXIe-6396 Multifunction Input or Output Module
User Guide
This guide describes how to confirm your NI data acquisition (DAQ) device is operating properly. Install your application and driver software, then your device, using the instructions packaged with your device.
Bridging the gap between the manufacturer and your legacy test system.
1-800-915-6216
www.apexwaves.com
sales@apexwaves.com
COMPREHENSIVE SERVICES
We offer competitive repair and calibration services, as well as easily
accessible documentation and free downloadable resources.
SELL YOUR SURPLUS
We buy new, used, decommissioned, and surplus parts from every NI series. We
work out the best solution to suit your individual needs.
Sell For Cash
Get Credit Receive
Trade-In Deal
OBSOLETE NI HARDWARE IN STOCK & READY TO SHIP
We stock New, New Surplus, Refurbished, and Reconditioned NI Hardware.
Confirm Device Recognition
Complete the following steps:
-
Launch MAX by double-clicking the NI MAX icon on the desktop, or (Windows 8) by clicking NI MAX from NI Launcher.
-
Expand Devices and Interfaces to confirm your device is detected. If you are using a remote RT target, expand Remote Systems, find and expand your target, and then expand Devices and Interfaces. If your device is not listed, press
to refresh the configuration tree. If the device is still not recognized, refer to ni.com/support/daqmx.
For a Network DAQ device, do the following:
If the Network DAQ device is listed under Devices and Interfaces» Network Devices, right-click it and select Add Device.
If your Network DAQ device is not listed, right-click Network Devices, and select Find Network NI-DAQmx Devices. In the Add Device Manually field, type the Network DAQ device’s host name or IP address, click the + button, and click Add Selected Devices. Your device will be added under Devices and Interfaces» Network Devices.
Note If your DHCP server is set up to automatically register host names, the device registers the default host name as cDAQ--<serial number>, WLS- , or ENET- . You can find the serial number on the device. If you cannot find the host name of that form, it may have been modified from the default to another value.
If you still cannot access your Network DAQ device, click the Click here for troubleshooting tips if your device does not appear link in the Find Network NI-DAQmx Devices window or go to ni.com/info and enter the Info Code netdaqhelp.
Tip You can test NI-DAQmx applications without installing hardware by using an NI-DAQmx simulated device. For instructions on creating NI-DAQmx simulated devices and importing
NI-DAQmx simulated device configurations to physical devices, in MAX, select Help»Help Topics» NI-DAQmx»MAX Help for NI-DAQmx. -
Right-click the device and select Self-Test. When the self-test finishes, a message indicates successful verification or if an error occurred. If an error occurs, refer to ni.com/support/daqmx.
-
For NI M and X Series PCI Express devices, right-click the device and select Self-Calibrate. A window reports the status of the calibration. Click Finish.
Configure the Device Settings
Some devices, such as the NI-9233 and some USB devices, do not need properties for configuring accessories, RTSI, topologies, or jumper settings. If you are installing only devices without configurable properties, skip to the next step. Configure each device with configurable settings that you install:
-
Right-click the device name and select Configure. Be sure to click the device name under the folder for the system (My System or Remote Systems) and NI-DAQ API in which you want to control the device.
For Network DAQ devices, click the device name and then the Network Settings tab to configure network settings. For additional information on configuring Network DAQ devices, refer to your device documentation. -
Configure the device properties.
• If you are using an accessory, add the accessory information.
• For IEEE 1451.4 transducer electronic data sheet (TEDS) sensors and accessories, configure the device and add the accessory as previously described. Click Scan for TEDS. To configure TEDS sensors cabled directly to a device, in MAX, right-click the device under Devices and Interfaces and select Configure TEDS. -
Click OK to accept the changes.
Install Signal Conditioning or Switch Devices
If your system includes SCXI signal conditioning modules, Signal Conditioning
Components (SCC) such as SC carriers and SCC modules, terminal blocks, or
switch modules, refer to the getting started guide for the product to install
and configure the signal conditioning or switch hardware.
Attach Sensors and Signal Lines
Attach sensors and signal lines to the terminal block or accessory terminals
for each installed device.
You can find device terminal/pinout locations in MAX, the NI-DAQmx Help, or
the device documentation. In MAX, right-click the device name under Devices
and Interfaces, and select
Device Pinouts.
For information about sensors, refer to ni.com/sensors. For information about
IEEE 1451.4 TEDS smart sensors, refer to ni.com/teds. If you are using
SignalExpress, refer to Use NI-DAQmx with Your Application Software.
Run Test Panels
Use the MAX test panel as follows.
- In MAX, expand Devices and Interfaces or Devices and Interfaces»Network Devices.
- Right-click the device to test, and select Test Panels to open a test panel for the selected device.
- Click the tabs at the top and Start to test the device functions, or Help for operating instructions.
- If the test panel displays an error message, refer to ni.com/support.
- Click Close to exit the test panel.
Take an NI-DAQmx Measurement
NI-DAQmx Channels and Tasks
A physical channel is a terminal or pin at which you can measure or generate
an analog or digital signal.
A virtual channel maps a name to a physical channel and its settings, such as
input terminal connections, the type of measurement or generation, and scaling
information. In NI-DAQmx, virtual channels are integral to every measurement.
A task is one or more virtual channels with timing, triggering, and other
properties. Conceptually, a task represents a measurement or generation to
perform. You can set up and save configuration information in a task and use
the task in an application. Refer to the NI-DAQmx Help for complete
information about channels and tasks.
Use the DAQ Assistant to configure virtual channels and tasks in MAX or in
your application software.
Configure a Task Using the DAQ Assistant from MAX
Complete the following steps to create a task using the DAQ Assistant in MAX:
- In MAX, right-click Data Neighborhood and select Create New to open the DAQ Assistant.
- In the Create New window, select NI-DAQmx Task and click Next.
- Select Acquire Signals or Generate Signals.
- Select the I/O type, such as analog input, and the measurement type, such as voltage.
- Select the physical channel(s) to use and click Next.
- Name the task and click Finish.
- Configure individual channel settings. Each physical channel you assign to a task receives a virtual channel name. To modify the input range or other settings, select the channel. Click Details for physical channel information. Configure the timing and triggering for your task. Click Run.
Use NI-DAQmx with Your Application Software
The DAQ Assistant is compatible with version 8.2 or later of LabVIEW, version
7.x or later of Lab Windows™/CVI™ or Measurement Studio, or with version 3 or
later of Signal Express.
Signal Express, an easy-to-use configuration-based tool for data logging
applications, is at Start» All Programs» National Instruments» NI Signal
Express or (Windows 8) NI Launcher.
To get started with data acquisition in your application software, refer to
the tutorials:
Application | Tutorial Location |
---|---|
LabVIEW | Go to Help “LabVIEW Help. Next, go to Getting Started with LabVIEW» |
Getting Started with DAQ»Taking an NI-DAQmx Measurement in LabVIEW.
Lab Windows/CVI| Go to Help “Contents. Next, go to Using Lab Windows/CVI*Data
Acquisition “Taking an NI-DAQmx Measurement in Lab Windows/CVI.
Measurement Studio| Go to NI Measurement Studio Help “Getting Started with the
Measurement Studio Class Libraries “Measurement Studio
Walkthroughs»Waikthrough: Creating a Measurement Studio NI-DAQmx Application.
Signal Express| Go to Help “Taking an NI-DAQmx Measurement in Signal Express.
Examples
NI-DAQmx includes example programs to help you get started developing an
application. Modify example code and save it in an application, or use
examples to develop a new application or add example code to an existing
application.
To locate LabVIEW, Lab Windows/CVI, Measurement Studio, Visual Basic, and ANSI
C examples, go to ni.com/info and enter the Info Code daqmxexp. For additional
examples, refer to zone.ni.com.
To run examples without hardware installed, use an NI-DAQmx simulated device.
In MAX, select Help “Help Topics» NI-DAQmx» MAX Help for NI-DAQmx and search
for simulated devices.
Troubleshooting
If you have problems installing your software, go to
ni.com/support/daqmx. For hardware
troubleshooting, go to ni.com/support and enter your device name, or go to
ni.com/kb.
If you need to return your National Instruments hardware for repair or device
calibration, refer to ni.com/info and enter the Info
Code rdsenn to start the Return Merchandise Authorization (RMA) process.
Go to ni.com/info and enter rddq8x for a complete
listing of the NI-DAQmx documents and their locations.
More Information
After you install NI-DAQmx, the NI-DAQmx software documents are accessible
from Start» All Programs “National Instruments “I-DAQ»NI-DAQmx document title
or (Windows 8) NI Launcher. Additional resources are online at
ni.com/gettingstarted.
You can access online device documentation by right-clicking your device in
MAX and selecting Help» Online Device Documentation. A browser window opens to
ni.com/manuals with the results of a search for relevant device documents. If
you do not have Web access, documents for supported devices are included on
the NI-DAQmx media.
Worldwide Technical Support
For support information, refer to ni.com/support for
access to everything from troubleshooting and application development self-
help resources to email and phone assistance from NI Application Engineers.
Visit ni.com/zone for product tutorials, example code, webcasts, and videos.
Visit ni.com/services for NI Factory Installation
Services, repairs, extended warranty, calibration, and other services.
To ensure measurement accuracy, NI factory calibrates all applicable hardware
and issues a Basic Calibration certificate, which you can get online at
ni.com/calibration.
Visit ni.com/training for self-paced training,
eLearning virtual classrooms, interactive CDs, Certification program
information, or to register for instructor-led, hands-on courses at locations
around the world.
For support available at the National Instruments worldwide offices, visit
ni.com, or contact your local office at ni.com/contact. National Instruments
corporate headquarters is located at 11500 North Mopac Expressway, Austin,
Texas, 78759-3504.
Refer to the NI Trademarks and Logo Guidelines at
ni.com/trademarks for more information on National
Instruments trademarks. Other product and company names mentioned herein are
trademarks or trade names of their respective companies. For patents covering
National Instruments products/technology, refer to the appropriate location:
Help” Patents in your software, the patents.txt file on your media, or the
National Instruments Patent Notice at
ni.com/patents.
You can find information about end-user license agreements (EULAs) and third-
party legal notices in the readme file for your NI product. Refer to the
Export Compliance Information at ni.com/legal/export-
compliance for the National
Instruments global trade compliance policy and how to obtain relevant HTS
codes, ECCNs, and other import/export data.
© 2003–2013 National Instruments. All rights reserved.
References
- Engineer Ambitiously - NI
- Engineer Ambitiously - NI
- Calibration Services - NI
- Contact Us - NI
- NI Learning Center - NI
- Using Info Codes - NI
- Search Results - NI
- Legal Information - NI
- Product Documentation - NI
- National Instruments Patents - NI
- Shop - NI
- NI Services - NI
- Support - NI
- Support - NI
- NI-DAQ™mx Download - NI
- Shop - NI
- NI Trademarks and Logo Guidelines - NI
- Education Services - NI
- Support - NI
- Support - NI
- PXIe-6396 National Instruments PXI Multifunction I/O Module | Apex Waves
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>