IOTA IIS Single Phase Central Inverter Instruction Manual

October 30, 2023
IOTA

IOTA IIS Single Phase Central Inverter

Product Information: IOTA IIS Inverter Factory Startup Program

The IOTA IIS Inverter Factory Startup program is designed to ensure expert installation of the IIS Inverter. A qualified IIS Technician will oversee the startup and initial testing of the IIS Inverter to ensure it performs according to factory specifications. The program includes a system integrity check, installation check, pre-load system check, site load check, site system check, training, demonstration, and extended warranty coverage.

Factory Startup Includes

  • System Integrity Check: The IIS Technician will inspect the IIS Inverter to ensure it arrived at the job-site unharmed.
  • Installation Check: The IIS Technician will verify that the installation meets all applicable performance and safety codes including NEC, NFPA, IEEE, and UL.
  • Pre-Load System Check: A pre-load test will be conducted to verify performance of all systems parameters under no-load or dummy load conditions. Note: dummy load tests must be pre-arranged with the factory.
  • Site Load Check: Critical load equipment is energized through the maintenance bypass (if available), and the full operating current is checked and verified to not exceed ratings of the IIS Inverter.
  • Site System Check: Critical load will be connected to the inverter and checked to ensure operation as specified under all operating and power failure conditions. Final calibrations to the system are made.
  • Training and Demonstration: The IIS Technician will demonstrate the operation and maintenance instructions to site personnel and answer any questions related to effective use and care of the IIS Inverter.
  • Extended Warranty: Participating in IOTA’s IIS Factory Startup Program provides an additional year of Warranty coverage on all electronic components, provided Factory Startup occurs within 180 days of ship date.

A start-up service request can be initiated for inverters that have been purchased with Factory Start Up by scanning the QR code. The IIS Factory Startup is only available on select IIS Inverter models: IIS (1.5kVA to 16.7kVA), 1100, IIS3P, and IISC.

Product Usage Instructions

To participate in the IOTA IIS Inverter Factory Startup program, a start-up service request can be initiated for inverters that have been purchased with Factory Start Up by scanning the QR code. The program is only available on select IIS Inverter models: IIS (1.5kVA to 16.7kVA), 1100, IIS3P, and IISC. The program includes a system integrity check, installation check, pre-load system check, site load check, site system check, training, demonstration, and extended warranty coverage. The IIS Technician will inspect the IIS Inverter to ensure it arrived at the job-site unharmed and verify that the installation meets all applicable performance and safety codes. A pre-load test will be conducted to verify performance of all systems parameters under no-load or dummy load conditions. The critical load equipment will be energized through the maintenance bypass (if available), and the full operating current is checked and verified to not exceed ratings of the IIS Inverter. The critical load will be connected to the inverter and checked to ensure operation as specified under all operating and power failure conditions. Final calibrations to the system are made. The IIS Technician will demonstrate the operation and maintenance instructions to site personnel and answer any questions related to effective use and care of the IIS Inverter. Participating in IOTA’s IIS Factory Startup Program provides an additional year of Warranty coverage on all electronic components, provided Factory Startup occurs within 180 days of ship date. For additional information, contact the IOTA Customer Support Team at IOTAcentralinverters@acuitybrands.com.

IOTA® IIS Central Inverter Factory Startup Program
IOTA’s IIS Inverter Factory Startup program provides the confidence and reliability of expert installation. A qualified IIS Technician will visit the job site to oversee the startup and initial testing of your IIS Inverter to ensure it performs to factory specifications*. Should any problems be detected, the IIS Technician will take corrective action to repair the affected components.

Factory Startup includes

System Integrity Check
The IIS Technician will inspect the IIS Inverter to ensure it arrived at the job-site unharmed.

Site Load Check
Critical load equipment is energized through the maintenance bypass (if available), and the full operating current is checked and verified to not exceed ratings of the IIS Inverter

Installation Check
The IIS Technician will verify that the installation meets all applicable performance and safety codes including NEC, NFPA, IEEE and UL.

Site System Check
Critical load will be connected to the inverter and checked to ensure operation as specified under all operating and power failure conditions. Final calibrations to the system are made.

Pre-Load System Check
A pre-load test will be conducted to verify performance of all systems parameters under no-load or dummy load conditions. Note: dummy load tests must be pre-arranged with the factory.

Training and Demonstration
The IIS Technician will demonstrate the operation and maintenance instructions to site personnel and answer any questions related to effective use and care of the IIS Inverter.

Extended Warranty

Participating in IOTA’s IIS Factory Startup Program provides an additional year of Warranty coverage on all electronic components, provided Factory Startup occurs within 180 days of ship date.

A start-up service request can be initiated for inverters that have been purchased with Factory Start Up by scanning the QR code. For additional information, contact the IOTA Customer Support Team at IOTAcentralinverters@acuitybrands.com

Extended On Site Training

Empower your facility staff to confidently maintain your IIS Central Inverter with Extended On Site Training*. An addition to our Factory Startup program, Extended On Site Training is conducted by a qualified IIS Inverter technician at the job site for the benefit of any on-site personnel. The training features a deep dive into the system operation, safety procedures, and maintenance of your IIS Central Inverter.

Standard Agenda: Extended On-Site Training
(Agenda may be customized at the time of service by the IIS technician to accommodate the needs of attendees)

  1. System Review
    • An overview of the system and the theory of its operation.

  2. Safety Procedures
    • Discussion of lethal system voltages and how to properly handle and wire the batteries.

  3. System Operation
    • Explanation of front meter panel functions and operation
    • Putting system in and out of bypass mode (when applicable)
    • Start-up and shut-down procedures

  4. Maintenance
    • Overview of proper system maintenance and maintenance schedule

  5. Troubleshooting
    • How to troubleshoot potential faults (note: system repairs should always be performed by a
    certified factory technician to maintain warranty.

  6. Warranty/Technical Support
    • An overview of the IIS Central Inverter warranty
    • How to contact the factory for support

  7. Q & A

For additional information, contact the IOTA Customer Support Team at IOTAcentralinverters@acuitybrands.com

Preventative Maintenance Plans

Ensure your IIS Central Inverter operates at peak performance through its operating lifespan with regular preventative maintenance performed by a qualified IIS Inverter technician*. Our national network of factory service technicians and factory trained and authorized service centers will travel to the job site to perform critical maintenance tasks on your IIS Central Inverter on an annual or bi-annual basis

Available Plans

5-Year Annual Plan
Includes one visit per year over five years (five visits total)

5-Year Bi-Annual Plan
Includes two visits per year over five years (ten visits total)

Preventative Maintenance Performed
At each visit, the following preventative maintenance functions are performed, but not limited to:

  1. Cleaning and tightening of battery terminal connections.

  2. Making a reasonable effort to remove dirt, dust, and debris from inside the electronics and battery cabinets.

  3. Checking and tightening wiring connections inside the electronics cabinet.

  4. Confirming functional operation of the unit. Performing load tests on the inverter using current connected loads.

  5. Testing emergency operation. Performing a load test on the inverter and batteries.
    (Note: the load must be available at the time the service is performed. The test is done with the inverter in emergency mode, i.e. utility power is not present and the inverter is operating with the full emergency load on-line.)

  6. Reviewing results with building personnel.

FACTORY STARTUP REGIONS

Factory startup pricing is dependent on job site location. See the map and chart below to determine which region number applies to your site, and communicate this information to your IOTA Sales Representative or Quotations Manager.IOTA-IIS-Single-Phase-Central-Inverter-fig-3IOTA-IIS-Single-Phase-Central-Inverter-fig-4www.iotaengineering.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals