ASSA ABLOY IN120 10X Line Bored Lock User Manual

October 30, 2023
ASSA ABLOY

ASSA ABLOY-LOGO

ASSA ABLOY IN120 10X Line Bored Lock

ASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig- \(2\)

MicroShield

ASSA ABLOY Group companies offer MicroShield®, an anti-microbial coating for door hardware. MicroShield uses proven silver ion-based technology from Agion®, a leading provider of antimicrobial solutions, to stem the spread of bacteria and other microbes.
MicroShield® is a trademark of ASSA ABLOY Access and Egress Hardware Group, Inc.

MicroShield® Coating

  • Revolutionary finish coating available on all SARGENT product lines, utilizes a silver-based antimicrobial compound from Agion Technologies
  • As an integral part of the finish coating, MicroShield lasts for the life of the hardware
  • MicroShield coating permanently suppresses the growth of bacteria, algae, fungus, mold and mildew. It is effective against a broad spectrum of bacteria.
  • Non-toxic and completely safe. The Agion antimicrobial compound is EPA and NSF-approved and FDA listed for use in medical and food preparation equipment.
  • Applications: Anywhere there is need for a clean environment (hospitals, laboratories, schools, medical centers, daycare, food processing etc.)

The Agion antimicrobial is not intended as a substitute for good hygiene. Coated products must still be cleaned to ensure the surfaces will be free of destructive microbes. ASSA ABLOY makes no representations or warranties, express or implied, as to the efficacy of the Agion antimicrobial. A copy of the Agion warranty is available upon request. Agion is a registered trademark of Agion Technologies, Inc., Wakefield, MA, USA.
Copyright © 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited.

Overview

10X Line Cylindrical Lever Locks

The SARGENT 10X Line is engineered to secure and protect high-traffic, high- abuse spaces. It doesn’t simply meet ANSI/BHMA Grade 1 performance standards for durability, strength and performance, it exceeds them – by as much as 20 times. That means occupants enjoy consistent performance for the life of the product.ASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(3\)

Applications

  • Heavy duty commercial and institutional interior and exterior doors
  • Offices
  • Schools/Universities
  • Hospitals
  • Manufacturing facilities
  • Government

Certification/Compliance

ANSI/BHMA| Certified ANSI/BHMA A156.2 (2017) Series 4000 — Grade 1 Certified ANSI/BHMA A156.41
---|---
UL/cUL| UL/cUL listed to US and Canadian safety standards for 3 hour doors up to 4′ x 10′ (double doors require 41- option)
NFPA 80| Conforms for life safety and property protection, Standard for Fire Doors and Other Opening Protectives
Positive Pressure| Meets ANSI/UL 10C, Positive Pressure Fire Test of Door Assemblies
ADA| All levers conform to ADA clear opening width requirements of ANSI A117.1
California State Reference Code (Formerly Title

19, California State Fire Marshal Standard)

| All levers with returns comply; levers return to within 1/2″ (13mm) of the door face
Windstorm/Hurricane| All individual components of a total door opening are required to comply with each code.

Any retrofit or other field modification to a fire-rated opening can potentially impact the fire rating of the opening, and Sargent Manufacturing Company makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing
fire-rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

Windstorm Certifications: Florida Building Codes & UL Listings

SARGENT Manufacturing’s products meet building codes that require hurricane and windstorm certifications, including some of the most stringent building codes as specified in the Florida Building Code, Miami Dade Code, and the International Building Code. Listed below are certifications and standards met by the 10X Line lock.
Florida Building Code: FL2998

UL Certification Directory: ZHEM.R21744 – Latching Hardware

ANSI/SDI A250.13 (2014)| “Testing and Rating of Severe Windstorm Resistant Components for Swinging Door Assemblies”
---|---
ASTM E330 (2002)| “Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights, and Curtain Walls by Uniform Static Air Pressure Difference”
ASTM E1886 (2005)| “Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials”

ASTM E1996 (2009)| “Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes”
(TAS) 201 (1994)| “Impact Test Procedures”

(TAS) 202 (1994)| “Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference”
(TAS) 203 (1994)| “Criteria for Testing Products Subject to Cyclic Wind Pressure Loading”

Published in the 7th Edition (2020), “Florida Building Code” (FBC), State Product Approval Number FL2998

UL Certification Directory: ZHLL.R21744 – Products for Use in Windstorm- rated Assemblies

Certifications to meet assembly requirements are done in conjunction with doors from ASSA ABLOY Group companies CECO DOOR and CURRIES.

ASTM E330 (2002)| “Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Air Pressure Difference”
---|---
ASTM E1886 (2005)| “Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials”
ASTM E1996 (2009)| “Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes”

Technical Details

10X Line Cylindrical Lever Locks

Door Prep ANSI/BHMA A156.115
Door Thickness 1-3/4″ (44mm) thick door adjusts to 2″ (51mm) standard

1-3/8″ (35mm) thick door, specify 1- Option for Adapter plates Over 2″ (51mm) up to 2-1/4″ (57mm), specify 31- Option

Minimum Stile| 4-1/2″ (114mm)
Handing| Non-handed

Backset

| 2-3/4″ (70mm) backset w/ 1-1/8″ front (standard)

2-3/8″ (60mm) backset w/ 1″ wide front (specify 20- Option) 3-3/4″ (95mm) backset w/ 1-1/8″ front (specify 23- Option) 5″ (127mm) backset w/ 1-1/8″ front (specify 25- Option)

Latchbolt| Stainless steel, 1/2″ (13mm) throw

Optional: Brass 3/4″ (19mm) throw deadlocking fire latch for pair of doors (specify 41- Option)

Front

| Wrought brass and stainless steel

2-1/4″ (57mm) x 1-1/8″ (29mm) Fixed Bevel

2-1/4″ (57mm) x 1″ (25mm) (included with 20- Option)

Strike

| Wrought brass, bronze and stainless steel 808 curved lip ANSI strike – standard

800 curved lip strike (specify 29- Option)

Wrought box strike available (specify WBS- Option)

Cylinder| Brass, 6-pin LA keyway, 1-bitted standard, specify KD for keyed different/random
Keys| Two nickel silver change keys per lock standard
Masterkeying| Can be master keyed or grand master keyed Construction key systems available
Lead Lining| Lead provided between lockbody and spring cartridge (specify 74- Option)
Tactile Levers| Knurling (etching) or abrasive coating (applied finish) applied to backside of levers (see Options page 16)
Finishes| See page 17
Warranty| Ten-year limited

Strength & Durability

  • Exceeds 3,100 in-lb abusive locked lever torque with no entry while maintaining egress (2.6 times ANSI/BHMA A156.2 requirements)
  • Exceeds 1,600 lbs offset lever pull with no entry for protection against attacks (8 times ANSI/BHMA A156.2 requirements)
  • Latch retraction with 100lb preload (2 times ANSI/BHMA A156.2) while maintaining ANSI/BHMA requirements for operation in warped doors
  • No access with minimum 100 vertical impacts for protection against vandalism attempts (20 times ANSI/BHMA A156.2 requirements)
  • Independent return springs allow lock to exceed ANSI/BHMA A156.2 Grade 1 cycle requirements without lever sag
  • Innovative push/turn button design to withstand excessive abuse against door stops or walls.

Flexibility

  • Lock chassis design supports all cylinder formats allowing flexibility for from fixed core to interchangeable core cylinders.
  • High Security and security key systems available (Degree®, Signature, Keso, XC)
  • Patent pending adjustable push/turn button for easy door thickness adjustment.
  • Rigid lever standard; freewheeling levers available for vandal resistance.

Broad Offering

  • Available with 26 mechanical functions
  • 14 finishes and Microshield options
  • Multilple lever options including decorative designs

Lever & Rose Designs

10X Line Cylindrical Lever Locks

Levers – Solid Cast ZincASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(4\)

Roses – Wrought Brass or Bronze

Decorative LeversASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(6\)

  • Any rose or lever on this page can be combined to suit individual tastes.
  • All lever height measurements represent the total distance from the door face. Dimensions are shown using L rose. *Lever with return to within 1/2″ of door face.

Functions

Single Cylinder FunctionsASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(7\) ASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(8\)ASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(9\)

Double Cylinder FunctionsASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(10\)

Non-Cylinder FunctionsASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(11\) ASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(12\)

Electromechanical Functions & Accessories

70 Electromechanical (Fail Safe)
71 Electromechanical (Fail Secure)

  • 10G70: Power off, unlocks outside lever
  • 10G71: Power off, locks outside lever
  • Deadlocking latch
  • Key retracts latch
  • Inside lever always allows egress
  • Voltage requirements: 12VDC or 24VDC Regulated; always specify voltage
  • 250mA at 24VDC or 500mA at 12VDC
  • Provided with ElectroLynx® 8-Pin Connector

RX- Monitoring of Inside Lever

  • Non-Contact Switch
  • Bidirectional lever rotation
  • Non-handed design
  • Internal switch offers N/O & N/C
  • Modular wire harness with ElectroLynx® 8-pin connector
  • Available functions: 04, 05, 15, 37, 70 & 71

Requirements for Electrical and Data Transfer

To answer the demand for “smart” electronic access control and locking solutions that require fast, easy, and cost-effective installation, ASSA ABLOY Group brands use the ElectroLynx® standardized plug-in connectors and color- coded wiring system.
With ElectroLynx, doorway components come pre-wired for easy hookup to the power source. Key to the system is the transfer device hinge that carries power from the frame to the locking hardware

Features of ElectroLynx®:

  • Makes it easy to bring power to the locking hardware
  • Wires have connectors that snap together, like plugging a telephone into a jack

To connect 10 Line Electrified Lock to the electronic access controlsystem, the following items are required:

  • 10 Line Electrified Lock
  • ASSA ABLOY Door Group pre-wired door, or ElectroLynx® retrofit cable (order from McKinney)
  • Electronic transfer device (ElectroLynx® electronic transfer hinge or Electrical Power Transfer with standard hinge, from McKinney)
  • ElectroLynx® cable from the hinge to above the ceiling (order from McKinney)

Information regarding cable selection, hinge requirements and order strings can be found in the McKinney Transfer Device Solutions catalog. Consult 800-810-WIRE (9473) with questions on application specifications and requirements.
McKinney QC8 ElectroLynx® hinges are recommended for Electrified 10 Line ApplicationsASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(14\)

12VDC & 24VDC Power SuppliesASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(15\)

  • UL Class 2 Listed
  • Four 12V models and four 24V models available
  • Integral battery charging capability keeps sealed lead acid gel/ cell at full charge in case of line voltage failure (737-battery sold separately)
  • Fused line voltage input with one, four, or eight DC outputs (depending on model)
  • Each circuit can be individually turned on and off via a slide switch; the power status of each is shown by an LED.
  • In the event of a DC short the problem is confined to the zone of difficulty
  • Fire alarm interface standard
SARGENT Model No. Description
3521 12V – 1 AMP Power Supply
3541 12V – 3 AMP Power Supply
3551 12V – 4.5 AMP Power Supply
3571 12V – 6 AMP Power Supply
737 12V – 5 AMP Hour Battery Backup
SARGENT Model No. Description
--- ---
3520 24V – 1 AMP Power Supply
3540 24V – 2 AMP Power Supply
3550 24V – 4 AMP Power Supply
3570 24V – 6 AMP Power Supply
738 24V – 5 AMP Hour Battery Backup

Cylinders

  • Finishes: 04, 15ASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig- \(16\)

| Interchangeable Core^
---|---
Type| Pins| Standard Cylinder| Hotel Cylinder| Large Format| Small Format

Conventional

| 6| C10X-1| C10X-2| 6300| 7300B
7| N/A| N/A| N/A| 7P-7300B
Signature| 6| 10-C10X-1| N/A| 10-6300| N/A

XC

| 6| 11-C10X-1| N/A| 11-6300| N/A
7| N/A| N/A| N/A| 11-7P-7300B
Keso| 12| F1-82-C10X-1| N/A| N/A| N/A
Degree® DG1| 6| DG1-C10X-1| DG1-C10X-2| DG1-6300| N/A
Degree® DG2| 6| DG2-C10X-1| N/A| DG2-6300| N/A
Degree® DG3| 6| DG3-C10X-1| N/A| DG3-6300| N/A

All cylinders are supplied with 2 nickel silver change keys. When cylinders are ordered keyed to 5 pin systems, the (6th) last chamber will be empty. Cylinders are supplied 1-bitted unless specified keyed random or master keyed. For master keyed orders provide keying details as requested on SARGENT Keyed Order Lead Sheets, located in the price book or contact customer service.
To order cylinders separately, specify part number x keyway x finish (i.e. C10X-1 x LA x 15)
Locks will be provided with the applicable tailpiece per the type interchangeable and/or removable core being used.
For example standard cores and XC cores require different tailpieces. When ordering complete locks, the appropriate option code must be specified in accordance to the permanent core being used. See pages 14-15 for cylinder options.

Cylinders with Competitive Keyways

Competitive Keyway Part Number
Schlage® C SC-C10X-1
Schlage® E SE-C10X-1

All cylinders are 6-pin, 0-bitted and supplied with two brass key blanks. Cylinders include tail piece.
Refer to Cylinders and Components catalog for more information

Interchangeable Core Tailpiece Packs (replacement parts)

Used with: Type Std. Doors Thick Doors (31-)

6300

10-6300

DGX-6300

| LFIC Conventional LFIC Signature LFIC Degree®| 10-3631| 10-3632
11-6300| LFIC XC| 10-3635| 10-3636
7300B| SFIC 6 Pin| 10-3633| 10-3634
7P-7300B

11-7P-7300B

| SFIC 7 Pin SFIC XC| 10-3641| 10-3642

Note : Tailpieces included with lock.

Levers That Accept Cylinders/Cores from Other Manufacturers

Cylinder Type| Option Code Ordered with Lock| Available Levers| Tailpiece Packs (provided with lock)| Competitor Cylinder Compatibility
---|---|---|---|---
Fixed Core
Schlage® 6-pin| 30-| All| 10-3625 (std)

10-3626 (31-)

| Schlage® Conventional or Primus®
Yale® 6-pin| YC-| All| 10-3639 (std)

10-3640 (31-)

| 1803-46L
Yale® 7-pin| YC-7P-| All| 1803A-46L
Interchangeable Core
SFIC 6- or 7-pin| 70-, 72-, 73-| All| 10-3633 (std)

10-3634 (31-)

| All 6- or 7-pin small format interchangeable cores
Schlage® LFIC 6-pin| SF-| B, L, P| 10-3627 (std)

10-3628 (31-)

| All Schlage® 6-pin large format interchangeable cores
Yale® 6-pin LFIC| YRC-| L, P| 10-1191 (std)

10-1192 (31-)

| All Yale® 6-pin large format interchangeable cores

SFIC cores are available through SARGENT, all other cylinders/cores not included and are provided by others.

Latches

Finishes : 03, 04, 09, 10, 10B, 10BE, 10BL, 20D, 32D, BSP, WSP

Plain/Unguarded Latch – 10U15, 10U65, 10U68:

Part No. Front Front Width Backset Throw
10-3187 Square Corner 1″ (25mm) 2-3/8″ (60mm) 1/2″ (13mm)
10-2022 Square Corner 1-1/8″ (29mm) 2-3/4″ (70mm) 1/2″ (13mm)
10-2054 Square Corner 1-1/8″ (29mm) 3-3/4″ (95mm) 1/2″ (13mm)
10-2057 Square Corner 1-1/8″ (29mm) 5″ (127mm) 1/2″ (13mm)

Deadlocking/Guarded Latch – All Other Functions:

Part No. Front Front Width Backset Throw
10-3186 Square Corner 1″ (25mm) 2-3/8″ (60mm) 1/2″ (13mm)
10-2000 Square Corner 1-1/8″ (29mm) 2-3/4″ (70mm) 1/2″ (13mm)
10-2053 Square Corner 1-1/8″ (29mm) 3-3/4″ (95mm) 1/2″ (13mm)
10-2058 Square Corner 1-1/8″ (29mm) 5″ (127mm) 1/2″ (13mm)
10-2634* Square Corner 1-1/8″ (29mm) 2-3/4″ (70mm) 3/4″ (19mm)

04/26D finish only

Miscellaneous:

Part No. Description
10-2059 3-3/4″ (95mm) Latch extension only
10-2060 5″ (127mm) Latch extension only

When ordering latches separately, specify Part No. x Finish (e.g., 10-3186 x 32D)

Strikes
Finishes: 03, 04, 09, 10, 10B, 10BE, 10BL, 20D, 32, 32D, BSP, WSP

4-7/8″ Curved Lip Strike (Standard)ASSA-ABLOY-IN120-10X-Line-Bored-Lock-
fig- \(19\)

  • Brass, bronze or stainless steel
  • Conforms to ANSI standard
  • Furnished standard with curved lip 1-1/4″ (32mm) from center of strike screw holes to end of lip
  • Lip lengths 1-1/8″ (29mm), 1-1/4″ (32mm), 1-3/8″ (35mm), 1-5/8″ (42mm), 1-7/8″ (48mm), 2-1/8″ (54mm), 2-3/8″ (60mm), 2-5/8″ (66mm), 2-7/8″ (73mm) and 3″ (76mm)
  • 77-1141 Wrought strike box available separately
  • To order strike separately, specify 808 strike x finish x lip length

2-3/4″ Curved Lip Strike (29- Option)ASSA-ABLOY-IN120-10X-Line-Bored-
Lock-fig- \(20\)

  • Brass, bronze or stainless steel
  • Furnished standard with 1-1/4″ (32mm) curved lip from center of strike screw holes to end of lip
  • Lip lengths 1″ (25mm), 1-1/4″ (32mm) standard, 1-1/2″ (38mm), 1-3/4″ (44mm), 2″ (51mm) and 3″ (76mm)
  • Plastic strike box AM-0044 included when 29- ordered with lockset
  • To order strike separately, specify 800 strike x finish x lip length

ANSI Wrought Strike Box

  • Used with ANSI 4-7/8″ (124mm) strike (#808)
  • To order with lock, specify option WBS
  • To order separately, specify 77-1141

Miscellaneous Parts

Part No. Description
10-3188 1-3/8″ Adapter plate pack (set of 2)
C10X-3 Emergency release cylinder (65 function)
10-0043 Push pin tool
10-1224 Screw pack (standard)
10-1250 Screw pack (29- option)
82-3855 6 lobe bit pack

6 bits (Sizes – T8, T9, T10, T15, T20, T25, T27)

Requires 9/32″ driver

82-3856| Spanner bit pack

5 bits (Sizes – 6, 8, 10, 12, 14) Requires 1/4″ driver

Cylinder Options

Conventional Cylinder| —| SARGENT® conventional cylinders supplied standard (nomenclature not required)
---|---|---

Degree Key System

| DG1-| SARGENT Degree key system level 1 (bump resistant with patented keys)
DG1-21- | Degree level 1 construction master keying
DG1-60-| Degree level 1 removable disposable construction core
DG1-63-| Degree level 1 removable core
DG1-64-| Degree level 1 removable construction keyed LFIC
DG1-65-
| Degree level 1 unassembled/uncombinated fixed core component cylinder (packed loose for field keying)
DG1-63-65-| Degree level 1 unassembled/uncombinated removable core LFIC (packed loose for field keying)
DG2- | SARGENT Degree key system level 2 (geographically exclusive; bump and pick resistant)
DG2-21-
| Degree level 2 construction master keying
DG2-60-| Degree level 2 removable disposable construction core
DG2-63-
| Degree level 2 removable core
DG2-64-| Degree level 2 removable construction keyed LFIC
DG2-65-
| Degree level 2 unassembled/uncombinated fixed core component cylinder (packed loose for field keying)
DG2-63-65-| Degree level 2 unassembled/uncombinated removable core LFIC (packed loose for field keying)
DG3-
| SARGENT Degree key system level 3 (geographically exclusive; UL437 certified; bump and pick resistant)
DG3-21- | Degree level 3 construction master keying
DG3-60-
| Degree level 3 removable disposable construction core
DG3-63-| Degree level 3 removable core
DG3-64-
| Degree level 3 removable construction keyed LFIC

Signature Key System

| 10-| SARGENT Signature key system
10-21-
| SARGENT Signature construction key system (lost ball)
Signature:

Large Format Interchangeable Core (Removable Core)

|

10-63-*

|

SARGENT Signature LFIC (removable core) cylinder

XC- Key System

| 11-| XC Key System
11-21-
| XC- Construction Key System (Lost Ball)

XC- Large Format Interchangeable Core (Removable Core)

| 11-60-| Lock to accept XC-LFIC (removable core) and provided with disposable plastic core; XC-LFIC permanent core ordered separately
11-63-
| Lock provided with XC-LFIC (removable core); Includes master keying, grand master keying
11-64-*| Lock to accept XC-LFIC (removable core) and provided with keyed construction core; XC-LFIC permanent core ordered separately.

XC- Small Format Interchangeable Cores

| 11-70-7P-| Lock to accept XC-SFIC (7-pin, removable core) and provided with disposable plastic core; XC-SFIC permanent core ordered separately
11-72-7P-
| Lock to accept XC-SFIC (7-pin, removable core) and provided with keyed construction core; XC-SFIC permanent core ordered separately
11-73-7P-| Lock provided with XC-SFIC (7-pin, removable core); Includes master keying, grand master keying
11-65-73-7P-
| Lock provided with uncombinated SFIC (7-pin, removable core); Packed loose

Construction Key Systems

| 21-| SARGENT Lost Ball Construction Keying for Conventional, XC and Signature Series (N/A with 63- or 73-)
22-
| SARGENT Construction Split Key System for Conventional Cylinders (existing systems only) (N/A with 10-, 11-, 63- or 73-)

Note : Cylinder Options continued on the following page
Options not available with 10XG50

Large Format Interchangeable Core

(Removable Core)

| 60-| Lock to accept LFIC (removable core) and provided with disposable plastic core; LFIC permanent core ordered separately
---|---|---
63-
| Lock provided with LFIC (Removable Core) Cylinder — (Includes masterkeying, grand masterkeying)
64-*| Lock to accept LFIC (removable core) and provided with keyed construction core; LFIC permanent core ordered separately

Small Format Interchangeable Cores

| 70-| Lock to accept SFIC (6 or 7-pin, removable core) and provided with disposable plastic core; SFIC permanent core ordered separately
72-
| Lock to accept SFIC (6 or 7-pin, removable core) and provided with keyed construction core; SFIC permanent core ordered separately
73-| Lock provided with SFIC (6-pin, removable core); Includes master keying, grand master keying
73-7P-
| Lock provided with SFIC (7-pin, removable core); Includes master keying, grand master keying
65-73-| Lock provided with uncombinated SFIC (6-pin, removable core); Packed loose
65-73-7P-
| Lock provided with uncombinated SFIC (7-pin, removable core); Packed loose

Keso & Keso F1

| 80-| Lock to accept Keso and Keso F1 cylinders — no cylinders provided (L,B,P levers only)
82-
| Lock provided with SARGENT Keso Security Cylinder (L,B,P levers only)
F1-82-| Lock provided with SARGENT Keso F1 Security Cylinder (Patented) (L,B,P levers only)
Bump Resistant| BR-| Bump Resistant Cylinder (available with Conventional & Conventional XC Cylinders only)
Keyed Different| KD-| Cylinders provided keyed differently/random
Less Cylinder| LC-| Lock supplied less Cylinder
Schlage® Keyways| SC-
| Schlage® C keyway cylinder, 0 bitted
SE-| Schlage® E keyway cylinder, 0 bitted
Accepts Schlage® Cylinders| 30-
| Lever to accept Schlage® fixed core cylinder – cylinder is not provided (all designs)
SF-*| L, B, or P lever to accept Schlage® large format interchangeable core (supplied less core, tailpiece included)

Accepts Yale® Cylinders/Cores

| YC-| Lever to accept Yale® 6-pin fixed core cylinder – less cylinder, tailpiece provided (all designs)
YC-7P-| Lever to accept Yale® 7-pin fixed core cylinder – less cylinder, tailpiece provided (all designs)
YRC-| L or P Lever to accept Yale® 6-pin large format interchangeable core (supplied less core, but with tailpiece needed)

Options not available with 10XG50

Notes:

  • To order the 10X Line Lock for use with ASSA V-10 (VA & VS) cylinders, specify the Less Cylinder (LC-) option. V-10 cylinders are available from ASSA, Inc. @ 800-235-7482.
  • 10X Line locks will be provided with the applicable tailpiece per the type interchangeable and/or removable core being used. For example standard cores and XC cores require different tailpieces. Appropriate option codes must be specified in accordance to the permanent core being used.

Mechanical Options

Thin Doors| 1-| Adapter plates for 1-3/8″ thick doors (2-3/4″ backset latch with 1-1/8″ front provided unless 20- option for 2-3/8″ backset also specified)
---|---|---

Backset Options

| 20-| 2-3/8″ backset latch with 1″ front
23-| 3-3/4″ backset x 2-1/4″ x 1-1/8″ front
25-| 5″ backset x 2-1/4″ x 1-1/8″ front
Strike| 29-| Strike #800. Lip length 1-1/4″. Lip lengths 1″ to 2″ in 1/4″ increments only.
Thick Doors| 31-| For 2″ to 2-1/4″ thick doors, centered in door prep, no paneling. Consult factory for other door thicknesses available by special application.
Security Fasteners| 36-| Six lobe security head screws
37-| Spanner head screws
3/4″ Throw| 41-| 3/4″ throw latchbolt x 2-3/4″ backset
Lead Lining| 74-| Lead provided between lockbody and spring cartridge

Tactile Warning Options

| 75-| Tactile warning – handicap warning milled on backside of inside lever (L, B, P levers only)
76-| Tactile warning – handicap warning milled on backside of outside lever (L, B, P levers only)
77-| Tactile warning – handicap warning milled on backside of both levers (L, B, P levers only)
85-| Tactile warning – abrasive coating finish on inside lever
86-| Tactile warning – abrasive coating finish on outside lever
87-| Tactile warning – abrasive coating finish on both levers
Freewheeling Trim| FW-| Freewheeling locking levers
Finish Protection| SG-| MicroShield® antimicrobial clear powder coat (only available with 15 and 26D finishes)
CPC-| Clear Powder Coat over 26D – 10XG05 x LL x 26D x CPC
Request to Exit| RX-| Request to exit – monitors inside lever rotation (available with functions: 04, 05, 15, 37, 70 & 71)
Box Strike| WBS-| Wrought box strike

Finishes, Packaging

Finish when cylinder provided with lock

SARGENT # Descriptions ANSI/BHMA
03 Polished brass, clear coated 605
04 Satin brass, clear coated 606
09 Polished bronze, clear coated 611
10 Satin bronze, clear coated 612
10B Oxidized bronze, oil rubbed 613
10BE Dark Oxidized Satin Bronze – equivalent 613E
10BL Oxidized satin, bronze, clear coated 613L
14 Polished nickel, clear coated 618
15 Satin nickel, clear coated 619
20D Statuary dark bronze, clear coated 624
26 Polished chrome 625
26D Satin chrome 626
BSP Black suede powder coat BSP
WSP White suede powder coat WSP
SG- Option MicroShield® antimicrobial clear powder coat

(only available with 15 and 26D finishes)

|
Zinc levers are plated to match ANSI/BHMA finish. Custom colors available, consult factory.

Split finishes:

–   Specify outside finish first i.e. 10XG05 x LL x 26D x 03 x RH

–   Handing must be specified

–   Strike and latch front will match the following: RH & LH = inside finish

RHR & LHR = outside finish

Lock Finish Cylinder/Core*
03, 04, 09, 10, 10B, 10BE, 10BL, 20D 04
14, 15, 26, 26D, WSP 15
BSP 15

Packaging

10XG05 x LL

4.8 lbs/box (2.2 kg/box)
8 boxes/case

How to Order

5 DG1- 10XG05 G L RH 15 Door 3

Quantity

|

Options*

| Lock & Function|

Rose

|

Lever

|

Hand

|

Finish

| Additional Information
| Available Options Pg 14-16| Available Functions Pg 7-9| Available Roses G & L| Available Levers Pg 6| RH,

LH, RHR, LHR

| Available Finishes Pg 17| Such as Item, Heading Number,

Door Number, Cylinder Keying Details (i.e KD, Keyset)

  • Multiple options may be selected

How to Specify HandingASSA-ABLOY-IN120-10X-Line-Bored-Lock-fig-
\(22\)

Architectural Specifications

Suggested Architectural Specifications – 2.0 Cylindrical Locks

  • A. Locks shall be 10X Line as manufactured by Sargent Manufacturing Company, New Haven, CT.
  • B. Locks shall be ANSI/BHMA Certified Products Directory (CPD) listed.
    • A156.2, Series 4000, Grade 1
    • A156.41
  • C. Locks shall exceed the requirements of ANSI/BHMA A156.2 Series 4000, Grade 1 with all standard trims, as follows:
    • Cycle Test: Exceeds ANSI/BHMA A156.2 Grade 1 requirements with no lever sag
    • Abusive Locked Lever Torque: Exceeds 3,100 in-lb with no entry while maintaining egress (2.6 times ANSI/BHMA A156.2 requirements)
    • Offset Lever Pull: Exceeds 1,600 lbs with no entry (8 times ANSI/BHMA A156.2 requirements)
    • Latch Retraction with Preload: Exceeds 100lb preload while maintaining ANSI/BHMA requirements for operation in warped doors (2 times ANSI/BHMA A156.2 requirements)
    • Vertical Impact: Exceeds 100 vertical impacts (20 times ANSI/BHMA A156.2 requirements)
  • D. Locks shall comply with UL 10C positive pressure requirements.
  • E. Locks required for fire doors shall be listed by Underwriters Laboratories for ratings of 3 hours (A label) and less, for doors up to 4’0″ (1.2m) x 10’0″ (3.0m) and pairs of doors 8’0″ (2.4m) x 10’0″ (3.0m)
  • F. Locks shall have a push/turn button adjustable for door thickness without disassembly.
  • G. Locks shall have a chassis design that supports all cylinder formats (except Keso) allowing flexibility for changing from fixed core to interchangeable core cylinders.
  • H. Locks shall be non-handed with bi-directional lever operation.
  • I. Lock levers shall be made of solid material.
  • J. Lock shall be available in a minimum of seven different lever designs.
  • K. Locks shall have a 2-3/4″ (70mm) standard backset.
  • L. Strikes shall be non-handed with a curved lip. Provide wrought boxes with strikes.
  • M. Locks shall have brass 6-pin cylinder standard.
    • Provide two nickel silver keys with each lock.
  • N. Locks shall have approximately 45 degrees of lever rotation in order to fully retract latch.
  • O. Locks shall have a ten-year limited warranty.

SARGENT Manufacturing Company 100 Sargent Drive New Haven, CT 06511 USA 800-727-5477
www.sargentlock.com
Founded in the early 1800s, SARGENT® is a market leader in locksets, cylinders, door closers, exit devices, electro-mechanical products and access control systems for new construction, renovation, and replacement applications. The company’s customer base includes commercial construction, institutional, and industrial markets.
Copyright © 2021, Sargent Manufacturing Company, an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited. Patent pending and/or patent www.assaabloydss.com/patents.

The ASSA ABLOY Group is the global leader in access solutions. Every day, we help billions of people experience a more open world.
ASSA ABLOY Opening Solutions leads the development within door openings and products for access solutions in homes, businesses and institutions. Our offering includes doors, frames, door and window hardware, locks, perimeter fencing, access control and service.
1-800-727-5477
www.sargentlock.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ASSA ABLOY User Manuals

Related Manuals