Irevo Assa Abloy Korea NTT600TSACC Door Keypad Lock Installation Guide

June 6, 2024
Irevo Assa Abloy Korea

Install-Module (optional)

Network or Yale Accentra Key Module
Optional Network or Yale Accentra Key module must be installed BEFORE batteries.

The Yale Accentra Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled.

Install Batteries & Cover

Test Electronic Lock Function by Keypad

Install Exit Device Cover

Congratulations, you’ve installed the Yale nex**Touch**™ Exit Trim Lock! Continue to customize your product.

Programming Instructions

Creating Master PIN Code

Creating a Master PIN Code must be performed upon installation or after resetting the lock to factory default. Programming and use of lock is not possible until this step has been successfully completed.

|
---|---

Creating User PIN Codes

Master PIN code must be created first. *Max User Codes = 500
The Yale Accentra Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled.

|
---|---

Creating User PIN Codes can’t

Locking & Unlocking Door with Registered Master or User PIN Code

The Yale Accentra Key module enables access with physical (cards and fobs) and mobile credentials ONLY. Creation and use of User PIN codes are disabled. Master PIN code is only used for programming and configuring lock with Yale Accentra Multi-Family configuration app and will not unlock the door.

Locking Door with Privacy Button

Resetting Lock to Factory Default

  1. Remove battery cover with a supplied hex wrench.
  2. Remove three (3) screws from the inside lock to release the lock from the bracket plate.
  3. Remove network module if installed.
  4. The reset button is on the back of the inside lock. Cables may stay connected. (See illustration for the location of the reset button.)
  5. Press the reset button for 3 seconds.
  6. While continuing to press the reset button, temporarily remove one (1) AA battery.
  7. Reinstall the battery.
  8. Release the reset button and wait approximately 15 seconds. Speaker will announce “Welcome to Yale.”
  9. Reinstall inside the lock.
  10. If utilizing a network module, remove batteries. Insert network module. Reinstall batteries.

When the lock is reset to factory defaults all user codes (including the Master PIN code*) are deleted and all programming features are reset to original default settings (see Factory Settings). Master PIN Code creation is the only option available and must be performed prior to any other programming of the lock.

Definitions

All Code Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all users (except Master) PIN code access. When attempting to enter a code while the unit is in Lockout, there will be an audible lock response. The touchscreen keypad will display a RED-locked padlock. (Main Menu selection #6.)
Automatic Re-lock Time: After a successful unlock, the unit will re-lock automatically after 5 seconds or for a duration selected in Advanced Lock Settings. (Main Menu selection #3 then #1)
Eco Mode: When enabled, Eco Mode puts the unit in low power mode extending the life of the battery.
Inside Indicator Light: This light will blink red when the trim is locked.
Language Setting Mode: Choose English (1), Spanish (2), or French (3) for lock’s voice prompts. (Main Menu selection #5)
Low Battery: When battery power is low, the Low Battery Warning indicator is a flashing red battery icon on the touchscreen keypad and the Yale logo will flash red on the push-button keypad. If battery power is completely lost, use a 9Volt battery override. To use 9V battery override apply 9V battery, in either direction, to terminals on the touchscreen for backup power option. Activate the touchscreen and enter your pin code to unlock the door.
Master PIN Code: The Master PIN code is used for programming and for feature settings. It must be created prior to programming lock. The Master PIN code will also unlock/lock the lock except when Accentra Key The module is installed.
Network Module Setting: With an optional Network Module installed, this setting becomes available (Main Menu selection #7) and allows the lock to connect with a network controller.
One-Touch Locking: When the unit is unlocked, activating the lock will lock the unit (during Automatic Re-lock duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid PIN code will re-lock the lock. (Main Menu selection #3 then #3.)
Passage PIN Code: When used to unlock, the lock will remain unlocked/open. The lock cannot be locked/secured until the Passage code is entered again. Privacy Button to Lock Door: If Automatic Re-lock is disabled, a short 1-second press of this button will lock the door.
Privacy Mode: With optional Door Position Switch installed, Privacy Mode enabled thru Menu Mode and the door closed, all keypad functions can be disabled with a 3 second press of the Privacy Button. Privacy Mode is disabled by default. Enable Privacy Mode thru Main Menu selection #3 then #4. With the door closed, press and hold the privacy button until the voice prompt indicates Privacy Mode is enabled. Privacy Mode duration ends when the door is opened and a voice prompt indicates Privacy Mode is disabled.
Shut Down Time: The unit will shut down for sixty (60) seconds and not allow operation after the wrong code entry limit (5 attempts) has been met. When the unit is Shut down, the keypad will be flashing.
Tamper Alert: Audible alarm sounds if attempting to forcibly remove the outside lock from the door.
User PIN Code: The User code operates the lock. The maximum number of user codes is 500.
Volume Setting Mode : The volume setting for PIN code verification is set to HIGH (1) by default; otherwise it can be set to Low (2) or Silent (3) for quiet areas. (Main Menu selection #4)
Wrong Code Entry Limit: After five (5) unsuccessful attempts at entering a valid PIN code, the lock will not accept a PIN code for the duration of shut downtime. The touchscreen keypad will flash and a red lock symbol will be at bottom of the keypad. The push-button keypad will flash and the Yale icon will flash blue for the shutdown period. The keypad will be available after shut downtime is complete.

Feature Programming Through Menu Mode Using Master PIN code*

  1. Touch to wake lock on touchscreen models. Touch key to wake lock on push-button models.

  2. Enter 4-8 digit master PIN code* followed by the key. Lock Response: “Menu mode, enter the number
    (Enter digit corresponding to the function to be performed), Press the key to continue.”

  3. Follow the voice commands.

  4. Press the key to complete the process and conclude the programming session.
    *The Master PIN code must be registered prior to any other programming of the lock.

Programming Troubleshooting

Symptom Suggested Action

The lock does not respond.
There are no lights or chimes and there is no mechanical sound
indicating latch bolt movement.| Touchscreen models become active when the Yale logo is pressed. Push Button models become active when the √key is pressed.
•Check batteries are installed and oriented correctly (polarity).
•Replace batteries.
•Check that cables are fully connected on the inside lock and not crimped.
•Apply 9V battery to terminals on the keypad for emergency power jump option.
Lock wakes but does not respond. Lights dim.| •Batteries do not have enough power. Replace batteries.
Lock chimes to indicate code acceptance, but the door will not open.| •Check for another locking device on the door (i.e. deadbolt).
•Check the door gaps for any foreign objects between the door and frame.
•Check that the motor cable is firmly connected to the PC board marked “MOTOR” on the inside lock.
The lock operates to allow access, but will not automatically re-lock.| •Ensure Auto Re-lock Mode is enabled by Master user.
•Replace batteries.
•Ensure Passage Mode is disabled by Master user.
User/Passage PIN codes will not register.| •Master user creates/manages User and Passage PIN codes.
•PIN codes must consist of 4 to 8 digits to register.
•PIN code may already be registered.
•Check to see if a yellow Accentra Key module is installed.
User PIN codes are disabled when Accentra is installed.
•PIN codes must be entered within 20 seconds (while the keypad is active) or the process will have to be restarted.
•Check √or gear can not  be used as part of the PIN code.
Upon entering a
User/Passage PIN code and pressing the √key, the lock chimes an error or lock times out without responding.| •Ensure All Code Lockout Mode is disabled by Master user. The touchscreen will display a red padlock on the keypad.
•The digits entered were incorrect or incomplete. Re-enter 4-8 digits followed by the check √key.
•Master user may have deleted PIN code.
•PIN code may have expired.
•Check to see if a yellow Accentra Key module is installed. PIN codes are disabled when Accentra is installed.
•PIN codes must be entered within 20 seconds (while the keypad is active) or the process will have to be restarted.
TS lock displays “Low Battery” on the keypad.
PB lock Yale logo flashes red.| •This is the alert to replace the batteries. Replace all four (4) batteries with new AA Alkaline batteries.
The lock operates, but it does not chime.| •Ensure Volume is set to Low or High by Master user.
The lock will not enter Privacy Mode.| •Ensure Privacy Mode is enabled by Master user.
•Ensure the door gap is correct.
•Hold the Privacy Button longer.

NOTE: When batteries are replaced, Network Module locks have a real-time clock that will be set through the User Interface (UI); it is recommended to verify the correct date and time, particularly those locks operating under Daylight Saving Time (DST).

Hardware Troubleshooting

The door is binding.
a. Check that door and frame are properly aligned and the door is free- swinging.
b. Hinges should not be loose or have excessive wear.

Factory Settings

Settings Factory Setting
Master PIN Code Creation required*
All Code Lockout Mode Disabled
Automatic Relock 3 Seconds
Eco Mode Disabled
Inside Indicator Light Enabled
Language English
One-Touch Locking Enabled
Privacy Disabled
Shutdown Time 60 Seconds
Volume Setting High
Wrong Code Entry Limit 5 Times

*The Master PIN code must be created prior to any other programming of the lock.

FCC :
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications (including the antennas) to this device that is not expressly approved by the manufacturer may void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications, However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void your authority to operate the equipment under FCC rules.

Industry Canada:
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is
subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

FCC and IC RF Radiation Exposure Statement:
This equipment complies with FCC and IC RF Radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co- located or operating in conjunction with any other antenna or transmitter.

THE YALE BRAND, with its unparalleled global reach and range of products, reassures more people in more countries than any other consumer locking solution.
THE ASSA ABLOY GROUP is the world´s leading manufacturer and supplier of locking solutions, dedicated to satisfying end-user needs for security, safety, and convenience.
Yale Commercial is a business associated with ASSA ABLOY Access and Egress Hardware Group, Inc., an ASSA ABLOY Group company. Copyright © 2017 – 2021, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

Support Contacts:
Customer Service Phone: 1-800-438-1951
Customer Service Fax: 1-800-338-0965
24/7 Support Phone: 1-855-213-5841
24/7 Support Email: [email protected]
Website: US.YaleHome.com
Email for orders: [email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Irevo Assa Abloy Korea User Manuals

Related Manuals