River OF GOODS 20575 Yvette 42 Inch 2-Light Indoor Antique Bronze Ceiling Fan with Remote Installation Guide

October 30, 2023
River OF GOODS

river-logo

River OF GOODS 20575 Yvette 42 Inch 2-Light Indoor Antique Bronze Ceiling

Fan with Remote

River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-
Fan-with-Remote-product

Product Information

Model No. 20575 is a ceiling fan that can be installed as a flush mount or with the provided down rod(s). The installation height options are indicated in the diagram provided in the manual. The product comes with safety tips, unpacking instructions, tools and material required, outlet box instructions, hanging bracket installation instructions, wiring instructions, canopy assembly instructions, blade assembly instructions, light kit and shade assembly instructions, and troubleshooting and maintenance instructions. The product weighs 6.5 kg/14.33lb and is made in China.

Safety Tips

  • Turn off the electricity to the fan at the main fuse box or circuit panel before installing or servicing the fan.
  • Read all instructions and safety information carefully before installing the fan and save these instructions.
  • Use gloves while handling fan parts with sharp edges to avoid personal injury.
  • Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 701999.
  • If you are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the instruction please use a qualified electrician.
  • Make sure you have a location selected for your fan that allows clear space for the blades to rotate and at least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.
  • The fan should be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other upright structures.
  • The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 50 Pounds (23 kilograms).
  • The outlet box must be supported directly by the building structure.
  • Make sure the electrical box that will hold the ceiling fan is fan-rated. There should be an inscription on the box indicating it.
  • Mount to the outlet box marked Acceptable for Fan Support, and use the mounting screws provided with the outlet box.
  • Wire connectors provided with this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan. Consult an electrician for the proper size wire connectors to use if your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires.
  • After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet box.

Product Usage Instructions

  1. Determine whether you want to install the ceiling fan as a flush mount or with the provided down rod(s).
  2. Measure your room height before installing the fan and consider the different installation height options indicated in the diagram provided in the manual.
  3. Read all instructions and safety information carefully before installing the fan. Save these instructions for future reference.
  4. Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 701999.
  5. If you are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the instruction please use a qualified electrician.
  6. Select a location for your fan that allows clear space for the blades to rotate and at least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips.
  7. Mount the fan so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other upright structures.
  8. Make sure the outlet box and ceiling support joist used are securely mounted, and capable of supporting at least 50 Pounds (23 kilograms).
  9. Make sure the electrical box that will hold the ceiling fan is fan-rated. There should be an inscription on the box indicating it.
  10. Mount the fan to the outlet box marked Acceptable for Fan Support, and use the mounting screws provided with the outlet box.
  11. Wire the fan using the wire connectors provided with the product. The wire connectors are designed to accept only one 12 gauge house wire and two lead wires from the fan. Consult an electrician for the proper size wire connectors to use if your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires.
  12. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet box.
  13. Assemble the fan blades, canopy, and light kit and shade according to the instructions provided in the manual.
  14. Turn on the electricity to the fan at the main fuse box or circuit panel after completing installation.

You may install your ceiling fan as a flush mount, or you may use the provided down rod(s). Measure your room height before installing the fan and consider the different installation height options indicated in the above diagram.

Weight of Appliance : 6.5 kg/14.33lb
Model No. 20575

Professional Installation Recommended
Note : Approximate Time of Assembly: 30 Minutes to 1 Hour

DIMENSION

River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-
Bronze-Ceiling-Fan-with-Remote-fig- \(1\)

SAFETY TIPS

WARNING : To reduce the risk of electrical shock, turn off the electricity to the fan at the main fuse box or circuit panel
before you begin the fan installation or before servicing the fan or installing accessories.
READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE INSTRUCTIONS.
CAUTION: To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.

  1. Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-
    1999. If you are unfamiliar with electrical wiring or if the house/building wires are different colors than those referred to in the instruction please use a qualified electrician.

  2. Make sure you have a location selected for your fan that allows clear space for the blades to rotate and at least seven (7) feet (2.13 meters) of clearance between the floor and the fan blade tips. The fan should be mounted so that the tips of the blades are at least thirty (30) inches (76 centimeters) from walls or other upright structures.

  3. The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 50 Pounds (23 kilograms). The outlet box must be supported directly by the building structure. Make sure the electrical box that will hold the ceiling fan is fan-rated. There should be an inscription on the box indicating it.
    WARNING : To reduce the risk of fire, electrical shock, or personal injury, mount to the outlet box marked “Acceptable for Fan Support,” and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
    WARNING : To reduce the risk of fire, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one 12 gauge house wire and two lead wires from the fan. If your house wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires, consult an electrician for the proper size wire connectors to use.

  4. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet box.
    WARNING : To reduce the risk of electrical shock, fire and to prevent humming noise do not use this fan with any solid state speed control device or control fan speed with a full range dimmer switch. Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.

  5. Do not operate the reverse switch until fan has come to a complete stop.

  6. Do not insert anything between the fan blades while they are rotating.
    WARNING : To reduce the risk of personal Injury, do not bend the blade brackets when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
    WARNING : To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.

  7. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for most cleaning.

  8. Suitable for use with solid-state speed controls
    WARNING : To reduce the risk of personal injury, use only parts provided with this fan. The use of parts OTHER than those provided with this fan will void the warranty.
    NOTE : The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense and caution are necessary factors in the installation and operation of this fan.

  9. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.

  10. Children should be supervised to ensure that they do not play with the appliance.

  11. CAUTION : MOUNT WITH THE LOWEST MOVING PARTS AT LEAST 2.1 METRES ABOVE FLOOR OR GRADE LEVEL.

  12. WARNING : All set screws must be checked, and retightened where necessary, before installation.

  13. WARNING : If unusual oscillating movement is observed, immediately stop using the ceiling fan and contact the manufacturer, its service agent or suitably qualified persons.

  14. The replacement of parts of the safety suspension system device and the mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.

  15. The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.

Unpacking Your Fan

Carefully open the packaging. Remove items from styrofoam inserts. Remove the motor housing and place on a soft, dry surface to avoid damage to the finish. Do not discard fan carton or styrofoam inserts should this fan need to be returned. Check against parts inventory
(listed below) that all parts have been included.

Parts Inventory

River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-
Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(3\)

Tools RequiredRiver-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-
Bronze-Ceiling-Fan-with-Remote-fig- \(4\)

  • Step ladder
  • Pliers
  • Screwdriver (flat head and Phillips)
  • Electrical tape
  • Circuit tester

Installation Preparation

River-OF-GOODS-20575-Yvette-42-Inch 2-Light-
Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(5\)

  • To prevent personal injury and damage, ensure that the hanging location allows the blade clearance of 7ft (2.13m) from the floor and 30 in (76cm) from any wall or obstruction.
  • The fan is suitable for room sizes up to 400 square feet (37.2 square meters).
  • This fan can be mounted with a down rod on a normal or vaulted ceiling. Down rod is included (5” length)
  • This fan can also be mounted using flush mount installation as seen in the diagram.
    WARNING : All set screws must be checked, and retightened where necessary, before installation.River-OF-GOODS-20575-Yvette-42-Inch 2-Light-
Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(6\)

Hanging Bracket Installation
Turn off circuit breakers to the current fixture from the breaker panel and be sure the operating light switch is turned to the OFF position.
WARNING : Failure to disconnect the power supply prior to installation may result in serious injury and fire hazards.

Remove existing fixture

  • WARNING : When using an existing outlet box, be sure the outlet box is securely attached to the building structure and can support the full weight of the fan. Ensure the outlet box is clearly marked “Suitable for Fan Support”. If not, it must be replaced with an approved outlet box. Failure to do so can result in serious injury.

  • CAUTION : Be sure outlet box is grounded properly and that a ground wire (green or bare) is present. Partially loosen screws in slotted holes of canopy. Remove the other 2 screws (along with the star washers) -save for later use. Twist canopy to
    remove the hanging bracket.River-OF-GOODS-20575-Yvette-42-Inch 2-Light-
Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(8\)

  • Install hanging bracket to outlet box using original screws, spring washers and flat washers provided with new or original outlet box. If installing on a vaulted ceiling, face opening of Hanging Bracket towards high point of ceiling. Arrange electrical wiring around the back of the hanging bracket and away from the hanging bracket opening

  • CAUTION : It is very important that you use the proper hardware when installing the hanging bracket as this will support the weight of the fan

ELECTRICAL OUTLET BOX

WARNING : Contact a qualified electrician to replace the outlet box if it is not suitable for ceiling fans
WARNING : To Reduce The Risk Of Fire, Electric Shock, Or Personal Injury, Mount To Outlet Box Acceptable for Fan Support of 15.9 kg (35 lbs) or less And Use Mounting Screws Provided With The Outlet Box. Most Outlet Boxes Commonly Used For The Support of Luminaires Are Not Acceptable For Fan Support And May Need To Be Replaced. Consult A Qualified Electrician If In Doubt. MOUNT ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT。

  1. If there is an existing outlet box, ensure it is clearly marked “Suitable For Fan Support”.
    If not, it must be replaced with an approved one.

  2. Secure the outlet box (or make sure the existing box is secured) directly to the building structure. Use appropriate fasteners and building materials. Wood joist and outlet box must be able to support a minimum of 50 pounds.

  3. Figure 1, 2 and 3 are examples of different ways to mount the outlet box in different situations.

  4. To hang the fan in locations where no ceiling joists is available. A hanger support bar may be required (Fig. 4)River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(9\)

Required for Canadian Installation ONLY

To ensure consumer safety and satisfy Canadian regulatory requirements, a safety support cable is provided to help prevent the ceiling fan from falling. To install, please follow the instructions below.

Parts

  1. Using the provided screw, attach the safety cable hook to the ceiling joist near the mounting bracket. Ensure the cable hook is covered by the canopy.River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(11\)
  2. Adjust the length of the safety cable to reach the safety cable hook by sliding the cable through the nut until the desired length is reached. Then, form the loop by threading the cable back through the cable and firmly securing. Place the loop onto the safety cable hook.
    Note : Although the safety support cable is only required for Canadian installation, it is recommended that it is utilized with any installation

Flush Mount Assembly

NOTE : If assembling with down rod, proceed to Step 7River-OF-
GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-
Remote-fig- \(12\)

  1. Remove ground wire along with the screw and washer from the mounting plate

  2. Remove four (4) screws and spring washers from upper motor housing

  3. Attach canopy to upper motor housing with same screws and washers removed in Step 2
    WARNING – Ensure screws are firmly secured

  4. Hang fan on mounting plate hook through canopy mount hole for easy hands-free electrical wiring3

Assembly with Down RodRiver-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-
Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(13\)

  1. Remove pin and clip from down rod. Slide the down rod through the canopy and the down rod cover as shown in figure

  2. Thread the electrical wires through the down rod and pull the extra wire slack through the down rod
    Tip : Apply a small piece of electrical tape to the ends of the electrical wires to keep them together when threading them through the down rod

  3. Loosen the yoke set screw. Place the down rod into the motor housing yoke and re-insert the previously removed pin and clip. Tighten yoke screw securely

  4. With the hanging bracket fully secured to the outlet box, you are now ready to hang your fan. Grab the fan securely with two (2) hands. Place the down rod ball into the hanging bracket and rotate until the ball sits securely in the hanging bracket tabRiver-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(14\) River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(15\)

Ceiling Fan Wiring and Remote Control Instructions

WARNING : Failure to disconnect power supply prior to the installation may result in serious injury and fire hazard

Important : Incorrect wire connection would damage the receiver.
Be sure outlet box is properly grounded or that a ground wire (GREEN or bare) is present. Make sure all electrical connections comply with Local Codes or Ordinances and the National Electrical Code. If you are unfamiliar with electrical wiring, or if the house/building wires are different colors than those referred to in the instructions, please use a qualified electrician.
When down rod is secured in place on the hanging bracket, electrical wiring can be made.

Wiring Instructions

River-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-
Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(16\)

  • Using the diagram above, proceed carefully while making the appropriate wire connections.
  • The wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.
  • The splices, after being carefully made, should be turned upward and pushed carefully up into the outlet box
    Note : Wrap each wire nut separately with electrical tape as an extra safety measure.

Remote Control Instructions

Note : Your fan is supplied with a radio frequency remote control unit. Kindly note that the fan does not contain a pull chain/switch for the lighting or fan speed control, as is dependent upon the radio frequency remote for use
The remote is pre-programmed from the factory and should work right out of the box once the battery is installed (AAA batteries included).
CAUTION : The battery will weaken with age and should be replaced before leaking takes as this will damage the transmitter. Dispose of used batteries properly, keep the batteries out of reach of children. To reduce the risk of fire or injury, do not use this product in conjunction with any variable (rheostat)wall control.
If the remote control doesn’t work properly, please follow the operation as belowRiver-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-
Ceiling-Fan-with-Remote-fig- \(17\)

Canopy Assembly

  1. Loosen the four (4) screws/washers on the side of the hanging bracket
  2. Lift canopy to the hanging bracket, and secure the canopy with the four (4) screws/washers. Securely tighten screws

Blade Assembly
Insert blade through slide slot of motor and align with

  1. three (3) holes
  2. Secure the blades with three (3) blade screws. Be careful not to overtighten.
  3. Repeat Step 3 for the remaining blades

Light Kit Assembly

  1. Remove the four (3) screws from the light kit and set aside
  2. Plug the connector from the light kit into the connectors from the switch housing
  3. Correct wiring
  4. White to White
  5. Blue to Blue
  6. Gently push the connectors into the switch housing and align the holes in the light kit with the holes in the switch housing. Secure the light kit with the four (3) removed screws
  7. Install the 2 included LED bulbs (E26,7W), align the four holes on the shade with the four holes on the light kit, install the rubber stopper , and finally secure with four (4) screwsRiver-OF-GOODS-20575-Yvette-42-Inch 2-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig- \(20\)

Ceiling Fan Troubleshooting

Welcome to the River of Goods family! We’re honored you’ve decided to include one of our ceiling fans in your home.River-OF-GOODS-20575-Yvette-42-Inch 2
-Light-Indoor-Antique-Bronze-Ceiling-Fan-with-Remote-fig-
\(21\)

MAINTENANCE

  1. The fan natural movements may cause some connections to work loose. A clicking or rattling noise is a certain sign of loosening screws. Check the support connections, brackets and blade attachment twice a year, and tighten all screws as necessary.
  2. Clean your fan periodically. Use only a damp cloth (never use solvents), and dust with a soft cloth or brush.
  3. You will never need to oil your fan, its permanently sealed bearing will prevent noise.
  4. Make sure the power is turned off at the main fuse or circuit panel before you attempt any repair