LUXPRO P521U PROGRAMMABLE / Non-Programmable THERMOSTAT Installation Manual
- October 30, 2023
- LUXPRO
Table of Contents
- LUXPRO P521U PROGRAMMABLE / Non-Programmable THERMOSTAT
- SYSTEM COMPATIBILITY
- FEATURES
- MOUNTING LOCATION
- INSTALL THERMOSTAT BASE
- WIRING INFORMATION
- WIRING DIAGRAMS
- 1 through #8. The position of these switches will change how the thermostat
- OPERATING INSTRUCTIONS
- ADVANCED FEATURES
- TECHNICAL ASSISTANCE
- LIMITED WARRANTY **
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LUXPRO P521U PROGRAMMABLE / Non-Programmable THERMOSTAT
View all LUXPRO thermostat manual
IMPORTANT!
- Please read all of these instructions carefully before beginning installation.
- Label every wire terminal designation on your existing thermostat wiring before removing your old thermostat.
- Ignore the color of the wires since they may not comply with any standard. Please connect wires using the terminal letter designations.
Thank you for your confidence in our product. To obtain the best results from your investment, please read and follow the installation procedures carefully, and one step at a time. This will save you time and minimize the chance of damaging either the thermostat or possibly your heating and cooling system. These instructions may contain information beyond that which may be required for your particular installation.
WARNING: Use Energizer® or DURACELL® Alkaline Batteries Only.
Energizer® is a registered trademark of Eveready Battery Company, Inc.
DURACELL® is a registered trademark of The Gillette Company, Inc.
SYSTEM COMPATIBILITY
The electrical rating for this thermostat is 1.5 Amps per terminal, with a maximum total combined load of 3.0A for all terminals combined.
COMPATIBLE WITH
- Most 24-volt heating and cooling systems
- 1 or 2 stage Heat / 1 stage Cool: Gas, Oil or Electric systems
- 1 or 2 stage Heat / 1 stage Cool: Heat Pump systems
- 3-wire hydronic (hot water) zone valves
- Gas Millivolt heaters
NOT COMPATIBLE WITH
120/240 VAC line-voltage systems (without a transformer), ask your LUXPRO
dealer for thermostats to control these systems.
FEATURES
- 1 or 2-Heat / 1-Cool, 5/2-day programming
- Universal Compatibility for all system types
- Weekdays and Weekends can be programmed separately
- Exclusive LUX®Speed SlideTM for easy programming
- User-selectable periods per day (2 or 4)
- User-selectable programmable or non-programmable operation
- LuxLight®EL (Electro-Luminescent) lighted display
- Programmable air filter life timer
- Keypad lockout for unauthorized users
- Manual temperature hold
- Temporary temperature override
- Adjustable temperature differential / cycle-rate
- Adjustable 2nd heat stage Offset setting
- User temperature calibration
- Adjustable heat/cool set temperature limit stops
- Smart recovery
- Dual-powered (battery and/or 24-volt system powered)
- Battery-free memory storage
- F/C temperature display
- 12/24-hour clock display
- 5/2-minute selectable time delay for equipment protection
TOOLS YOU MAY NEED
- **** Screwdrivers
- Wire Stripper
- Wire Cutter
Drill with assorted drill bits (new installations only)
MOUNTING LOCATION
On replacement installations, mount the new thermostat in place of the old one unless the conditions listed below suggest otherwise. On new installations, please follow these general guidelines:
- Mount the thermostat on an inside wall, about 5 (1.5m) above the floor.
- Do not locate the thermostat where air circulation is poor such as in a corner, alcove, or behind a door that is normally left
- Do not locate the thermostat where unusual heating or cooling conditions may be present, such as: direct sunlight, above a lamp, television, or radiator, or on a wall next to an exterior door or
- Do not locate in a damp environment, as this can lead to corrosion that may shorten the thermostat
- If painting or construction work is still ongoing, cover the thermostat completely or wait until this work is complete before installation.
WARNING
All wiring must conform to the local codes and ordinances that are in your
particular location.
REMOVE OLD THERMOSTAT
- Turn OFF the electricity to all heating and cooling components. Do not turn the electricity back on until all work is completed.
- Remove the front portion of your old thermostat to expose the wiring connections.
- Write down the letters printed near each wire terminal that is used, and also the color of each wire that is connected to it. Self-adhesive wire labels are also enclosed.
- Carefully remove the wires one at a time, and bend them in a manner so that they do not fall back inside the wall. Do not allow bare wire ends to touch each other.
- Loosen the mounting screws for the old thermostat and carefully remove it from the wall.
INSTALL THERMOSTAT BASE
- Strip wire insulation leaving only 3/8 in. (9.5mm) bare wire ends, and clean off any corrosion present.
- Fill the wall opening with non-combustible insulation to prevent drafts from affecting the thermostat’s normal operation.
- Route the wires through the opening in the new thermostat base plate, and hold the base against the wall. Try to line up the screw holes from the prior thermostat, and install the mounting screws.
- If the previous holes cannot be used, hold the thermostat base against the wall so that it appears straight and level (position the base for best appearance) and mark for the new screw holes. Attach the base to the wall using the screws provided (use the supplied plastic anchors if needed when mounting to a soft material such as drywall).
WIRING INFORMATION
CONNECTING THE WIRES
When attaching the wires to the thermostat, please ensure that the bare wire
ends are held ALL the way into the terminal block while the screw is being
tightened.
WIRING BASE PLATE NOTICE
This thermostat model is part of a family of similar models that have the same
general visual appearance. Even though this base plate may look the same as
base plates from other models, the wiring connections may have different
terminal letters for different purposes. Please do not interchange the back
plates and/or thermostat front halves of other similar-looking models. Doing
so may cause undesired heating and/or cooling operations to occur.
CAUTIONS AND WARNINGS
- The thermostat requires batteries to operate and failure or sub-standard performance of the batteries may impair or prevent the correct operation of the thermostat. Use Duracell or Energizer alkaline batteries ONLY for all Lux thermostats requiring batteries. BE SURE TO CHANGE THE BATTERIES AT LEAST ONCE A YEAR. Failure to follow these battery instructions could result in property damage and/or personal
- The electrical rating for this thermostat is 5 Amps per terminal, with a maximum total load of 3.0A for all terminals combined.
- The thermostat contains parts that may wear out through use and are susceptible to failure if over-loaded or used in a manner other than as indicated in the
- Check unoccupied residences regularly to ensure that all systems are operating
- Check any heating/air-conditioning system including this product before operation and at regular
- Electrical interference, static electricity, failure or substandard performance of batteries, wiring defects in the installation and/or characteristics of the connected HVAC devices may prevent the system from regulating heating and cooling as
- The thermostat is a sensitive device and dropping the product can cause damage to critical components. If the product is dropped or shaken violently during transport or installation then it should be replaced
- Persons with physical or mental limitations may not be able to promptly respond to a malfunction of the heating/air-conditioning
- All residents should be made aware of the potential in any system for malfunctions that could cause continuous heating or cooling and should be familiar with the operation and location of the heating/cooling appliance on/off
- Read the instruction manual completely before installing the thermostat. Additional information is available at our website luxproducts.com. You should consult a qualified HVAC technician or an electrician if you do not fully understand the installation instructions
WIRING DIAGRAM NOTES
(Important, please read all notes before connecting wires)
-
If the information provided in the following wiring diagrams does not clearly represent or match your system, please refer to the “TECHNICAL ASSISTANCE” section of this manual, and contact us before removing any of your existing thermostats
-
All of the dashed wires shown in the wiring diagrams are either optional, or their usage depends upon your specific system type or brand. For example, Diagram #1 shows the fan wire as optional. If your system does not have a fan, then this terminal will not be
-
Terminal letters shown in black represent typical wiring applications. Depending upon the brand of your specific system or thermostat, your terminal letters may not match Terminal letters shown in gray represent other possible wiring designations that you might see on your existing thermostat terminals.
-
The optional “C” terminal is used for powering the thermostat by the 24-volt system, using the System Common This can be used alone, or in addition to installing batteries as a backup.
NOTE: Connecting the System Common wire to the thermostat is not necessary for heating and cooling to function properly. -
If your old thermostat has both a “Y” and “C” wire present, then “C” is most likely a System Common
-
For Heat Pump systems, you will use either the “O” terminal or the “B” terminal on this thermostat, but not If your old thermostat has both an “O” and a “B” wire present, then “B” is likely a System Common wire and may be connected to the “C” terminal. Connecting a System Common wire to this thermostat’s “B” terminal may damage the thermostat, and also your heating and cooling system.
-
Some Heat Pump systems have a wire for AUX electric heat (usually W2), and also a separate wire for Emergency electric heat (usually E). This thermostat uses the W2 terminal for both AUX and Emergency Tape off your “E” wire, and confirms that all components function without it.
-
If replacing an old thermostat that has a mechanical clock, there may be two wires labeled as “C” for the clock Tape off these wires and do not connect them to the “C” terminal of this thermostat.
WIRING DIAGRAMS
DIAGRAM SYSTEM TYPE / DESCRIPTION PAGE #
-
CONVENTIONAL: HEATING………………………………8
1-STAGE OR 2-STAGE 2, 3, 4, 5 WIRES -
CONVENTIONAL: HEATING………………………………9
3-WIRE ZONE VALVE 3, 4 WIRES -
CONVENTIONAL: COOLING…………………………….10
1-STAGE 3, 4 WIRES -
CONVENTIONAL: HEATING AND COOLING …………….11
1-STAGE HEAT 4, 5 WIRES -
CONVENTIONAL: HEATING AND COOLING …………….12
2-STAGE HEAT 5, 6 WIRES -
CONVENTIONAL: HEATING AND COOLING …………….13
TWO-TRANSFORMERS 5, 6 WIRES -
HEAT PUMP: HEATING AND COOLING …………….14
NAGLE-STAGE ONLY 4, 5 WIRES -
HEAT PUMP: HEATING AND COOLING …………….15
WITH AUX / EMERGENCY HEAT 5, 6 WIRES
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE : THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE : THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE : THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
NOTE: THE BLACK TERMINAL LETTERS ARE TYPICAL, GRAY TERMINAL LETTERS ARE BRAND SPECIFIC
HARDWARE SETUP OPTIONS
On the thermostat’s circuit board, there is a row of DIP switches, labeled
1 through #8. The position of these switches will change how the thermostat
operates, and also how information is conveyed to you on the LCD display screen. If you make any changes to these options, the changes are not recognized unless you either: change the position of the HEAT/OFF/COOL mode switch, or press the “HW RST” (Hardware Reset) button on the circuit board. The use of this button is further described in the “ADVANCED FEATURES” section of this manual. These option switches are very small and should be moved carefully using objects such as: an eyeglass screwdriver, fine-point pen, toothpick, or similar. The listing below describes the available choices for each option switch
SWITCH #1 (SYSTEM): [OFF/DOWN = FURN, default] This setting is used for the majority of all heating systems that are not heat pumps. Examples for this setting would be: natural gas furnace, hot water baseboard heat, and oil heat. [ON/UP = HP] Use this setting if you have a heat pump unit (which looks just like an outside air conditioning unit, but is used for both cooling and heating).
SWITCH #2 (TYPE): [OFF/DOWN = PROG, default] The thermostat controls the room temperature by following temperature program periods that you set up based upon your daily routine. [ON/UP = MAN] The thermostat operates manually just like a mechanical or non-programmable model. This method of operation is very basic and only shows the room temperature and set temperature; there are no temperature programs, days of the week, or clock times.
SWITCH #3 (PERIODS): [OFF/DOWN = 4, default] The thermostat uses four temperature program periods in both heating and cooling (MORN, DAY, EVE, and NITE). Each period has a separate start time and a set temperature. [ON/UP = 2] The thermostat operates in the same manner as above, however there are only two temperature program periods for heating and cooling (DAY and NITE). This may be more convenient if you are typically home during the day, and only need the set temperature to be different while you are sleeping.
SWITCH #4 (SCALE): [OFF/DOWN = F, default] All temperature values are displayed using the Fahrenheit scale. [ON/UP = C] This setting displays all temperature values using the Celsius scale.
SWITCH #5 (TIME): [OFF/DOWN = 12 HR, default] This setting displays the clock times and temperature program period start time values on the screen using US standard AM and PM values. [ON/UP = 24 HR] This setting displays the clock and temperature program period start time values on the screen using the 24 HR military-time format (17:30 hours, 22:00 hours, without using AM/PM).
SWITCH #6 (DELAY): [OFF/DOWN = 5 MIN, default] This sets the minimum length of time that Heat or Cool must remain either On or Off, before it will automatically switch to the alternate On or Off state. This internal delay prevents rapid cycling of your system and provides equipment protection, particularly for cooling units. The 5-minute setting is fine for most applications. [ON/UP = 2 MIN] If you feel that your system may need to cycle more frequently than the thermostat is allowing, then you may use the 2-minute setting.
SWITCH #7 (RECOVERY): [OFF/DOWN = DISABLE, default] The Early
Recovery feature affects how the thermostat transitions from an energy-saving setback (DAY and NITE) program period, to a comfort (MORN and EVE) program period temperature, when it is following the daily temperature programs. When this is disabled, the thermostat makes a set temperature change at the beginning of an upcoming period’s start time. [ON/UP = ENABLE] The Early Recovery feature will calculate the capability of your system and turn on the heating or cooling early so that the temperature in your home reaches the desired set point as close as possible to the start of the period. During the time that the thermostat is performing a recovery, the word “RECOV.” will be shown in the display screen.
SWITCH #8 (BATTERY MONITOR): [OFF/DOWN = ON, default] This setting regularly monitors the battery level, and shows “LOW BAT” on the screen if the batteries need to be replaced. Use this setting at all times when batteries are present in the thermostat. [ON/UP = OFF] This setting only applies if you are NOT physically using batteries in the thermostat, and are powering the thermostat entirely from the system (“C” wire terminal).
GAS / ELEC SLIDE SWITCH (FAN OPERATION)
****This switch is a physical component by itself on the circuit board and is much larger than the DIP switches listed above. [DOWN = GAS, default] This setting lets the heating system control the blower fan automatically by itself. Systems that would typically use the “GAS” setting would be: natural gas, propane, or oil furnaces. This setting has no effect upon Cool mode operation. [UP = ELEC/HP] This setting runs the system’s blower fan when heat is called for, and is required for heating systems that do not control their own fan while the thermostat is in HEAT mode. Heat pump systems, and units with an electric heating element typically require this setting.
COMPLETE THE INSTALL
Once the hardware options are set, install two new Energizer® or DURACELL®
“AA” size alkaline batteries. Ensure that the batteries are installed in the
proper direction as per the markings shown in the battery tray. If the
batteries were already installed before changing the hardware setup options,
change the position of the HEAT/OFF/COOL System Mode switch to accept the new
hardware option switch settings.
FRONT PANEL ITEMS
The items below are all located behind the door on the front of the
thermostat. To open the door, pull outwards using the small indentation in the
center of the top edge of the thermostat housing.
HEAT / OFF / COOL, SYSTEM MODE SWITCH: Set this switch to HEAT to control your heating system, and COOL to control your cooling system. The OFF position will disable both the heating and cooling units.
AUTO / ON, FAN MODE SWITCH: When this switch is in AUTO, the blower fan
(if present in your system) will automatically cycle on and off by itself
while heating or cooling is running. When in the ON position, the blower fan
will run constantly with or without a demand for heating or cooling, even when
the System Mode switch is in the OFF position.
NOTE: The Fan Mode switch only works if your system provides a wire for the
thermostat’s “G” wire terminal, to control a blower fan. The Fan Mode switch
has no effect in systems that do not have a blower fan (such as a hot water
radiator system).
MULTI-FUNCTION, SET SLIDE SWITCH: This switch provides an easy way to quickly access the most commonly used thermostat settings. This switch has 4 individual positions, and unless a specific setting is being adjusted, this switch should always remain in the RUN position for the thermostat to control the room temperature. The other Set Slide switch positions are described in greater detail in the ADVANCED FEATURES section. NOTE: This switch is only operable when the thermostat is in “Programmable” mode. When the thermostat is used in “Manual” control mode, all 4 of the switch positions will act like the RUN position, except the “AIR FILTER” position
UP / DOWN BUTTONS: The UP and DOWN buttons are used to adjust any item that can be changed by the user. Examples are the set temperatures, clock times, and days of the week. In many cases, an item may be flashing if it can currently be adjusted.
HOLD BUTTON: This button activates and deactivates the manual Temperature Hold feature.
EMER BUTTON: When in Normal Run mode, the usage of this button varies depending upon your specific system configuration. For heat pump systems, pressing this button enables your emergency heat function, which is described in greater detail in the OPERATING INSTRUCTIONS section. For conventional systems, there is no such thing as emergency heat, so this button will have no effect.
NEXT BUTTON: This button is mostly used while setting items such as software options, and temperature program periods. When there are several items on the screen that can be changed, usually one of them is flashing indicating that it can be adjusted. Pressing the NEXT button will cycle through which item is flashing.
OPERATING INSTRUCTIONS
**SET DAY AND TIME:** Place the Set Slide Switch into the DAY/TIME position. With the day flashing, press UP or DOWN to set the day of the week. Press NEXT and the clock time will start flashing. Use UP or DOWN to set the time, making sure the AM/PM indication is correct. Holding the UP or DOWN buttons will make the clock digits scroll rapidly. Return the Set Slide switch to the RUN position when finished
HEATING AND COOLING : Basic operation of your heating or cooling system can be obtained with the Set Slide Switch in the RUN position and choosing either HEAT or COOL on the System Mode switch. The temperature can be adjusted using the UP and DOWN buttons. When the thermostat is first powered up, it will follow a default temperature routine that is preset from the factory (shown below).
PERIOD | HEAT MODE | COOL MODE |
---|---|---|
MORN | 6:00 AM 70 ° F (21 ° C) | 6:00 |
AM 78 ° F (26 ° C)
DAY| 8:00 AM 62 ° F (17 ° C)| 8:00
AM 82 ° F (28 ° C)
EVE| 6:00 PM 70 ° F (21 ° C)| 6:00 PM 78
° F (26 ° C)
NITE| 10:00 PM 62 ° F (17 ° C)| 10:00 PM 75
° F (24 ° C)
EMERGENCY HEAT: (Heat Pump Configuration Only). While in normal Heat mode with the Set Slide switch in the RUN position, one single press of the EMER button will activate Emergency Heat mode. A single press again will end Emergency Heat mode, and return back to normal Heat mode. While in Emergency Heat mode, the word “EMER” will also be shown in the middle portion of the display screen. If a power loss occurs while in Emergency Heat mode, the thermostat will continue to remain in Emergency Heat mode even after the power comes back on. Emergency Heat mode will prevent the first stage of your heat pump system from turning on, and use only the “W2” heat terminal (Auxiliary Heat) as the primary heating source. This will not only prevent the heat pump from wasting energy if outdoor temperatures are too low to support efficient operation, but it could also prevent damage to the heat pump if outside temperatures are below the manufacturer’s recommendations. As every heat pump has different operating characteristics, you should refer to your heat pump literature to determine when to disable the heat pump and run in Emergency Heat mode.
LCD DISPLAY BACKLIGHT: The display screen is lighted to assist viewing at nighttime, or in locations with low light levels. A press of any button on the front panel will light the display for approximately 10 seconds. Any button presses that occur while the light is on will reset the 10-second timer, causing the screen to remain illuminated for an additional 10 seconds.
TEMPERATURE OVERRIDE: While in Program RUN mode, the set temperature can be temporarily changed by pressing UP or DOWN. The set temperature will return to the programmed value stored in memory when the start time of the next upcoming program period is reached (Morn, Day, Eve, Nite). While a Temporary Override is in effect, the word “OVERRIDE” will be shown in the display screen. An Override may be canceled by moving the mode switch to OFF, then back to HEAT or COOL.
MINIMUM RUN TIME: The thermostat has a default internal time delay of 5 minutes between load-on and load-off activations to prevent heating or cooling system damage, which can occur from very frequent cycling. If heating or cooling does not turn on right away with a manual change in set temperature, please wait at least 5 minutes and the system should resume normal operation.
TEMPERATURE HOLD: A Temperature Hold is used for maintaining a fixed set temperature. Once a Hold is initiated, the thermostat will maintain the set temperature indefinitely. A Hold may be used for days, weeks, or even months at a time, as long as the thermostat has adequate power. To enter Hold mode: press the HOLD button one time and the word “HOLD” will appear in the display. To cancel a Hold, press the HOLD button one more time. If a complete power failure occurs during a Temperature Hold, the thermostat will continue to remain in Hold mode even after the power comes back on. NOTE: If you plan to leave the thermostat in Hold mode for an extended duration (unattended), it is advisable to install new Energizer® or DURACELL® “AA” size alkaline batteries prior to leaving to ensure reliable operation of your heating and cooling system.
STATIC NOTICE : This thermostat is protected against normal static electric discharges, however, to minimize the risk of damaging the unit in extremely dry weather, please touch a grounded metal object before touching your thermostat
TEMPERATURE PROGRAMS
By default, this thermostat has 4 separate program periods for both Heat
and Cool modes, they are MORN, DAY, EVE, and NITE. Each period ends at the
start time of the following period. The heat programs are set in HEAT mode,
and the cool programs are set in COOL mode.
NOTE: If the thermostat is configured to use only 2 periods per day instead of
4 (HARDWARE SETUP OPTIONS), the thermostat will only use the DAY and NITE
periods. The MORN and EVE periods will not be visible on the screen.
SET TEMPERATURE PROGRAMS: Move the Set Slide switch to the TEMP PROG position. Programming will start with all 5 weekdays, Monday through Friday (all grouped together). Use the UP/DOWN buttons to adjust the start time for the MORN period, then press the NEXT button to advance. Use the UP/DOWN buttons to adjust the set temperature for the MORN period, then press the NEXT button to advance. Now adjust the start time and set the temperature for the DAY period, pressing the NEXT button after each to advance. Continue with these same steps to adjust the start times and set temperatures for the EVE and NITE program periods. When the NITE period is finished for the weekdays, the thermostat will advance forward to the weekend program, with the MORN period start time flashing. You will be setting the program periods for both Saturday and Sunday (grouped together). Perform the same steps that you used for setting the weekday periods, pressing the NEXT button to advance through each flashing value. Return the Set Slide switch to the RUN position when you are finished
ADVANCED FEATURES
TEMPERATURE SWING AND OFFSET SETTING
A thermostat works by turning your heating or cooling system on and off
whenever the room temperature varies from the desired set-point temperature.
The amount of this variation is called the swing. Generally, your system
should cycle on about 3 to 6 times per hour. A smaller swing number makes the
system cycle more frequently, so the room temperature is more precise and
constant. A larger swing number will make the system remain on for a longer
duration each time and decreases the number of cycles per hour. There is only
one Swing setting, and this determines the cut-in and cut-out points for both
the first and second stages (if present), in both Heat mode and Cool mode.
NOTE: The Swing and Offset settings need to be performed in a timely manner,
as the thermostat will timeout and automatically exit these adjustment screens
after approximately 10 seconds without a button press.
TO CHANGE THE SWING SETTING: Ensure that the System Mode switch is in the OFF position and the Set Slide switch is in the RUN position. Press and hold the HOLD button for at least 5 seconds. The words “SET” and “SWING” will appear on the screen, along with a single flashing digit. Use the UP/DOWN buttons to change the number value between 1 and 9 (0.25F to 2.25F, in 0.25F degree increments). Number 1 is the default setting. Press the NEXT button to accept the swing set and proceed to the OFFSET setting.
TO CHANGE THE OFFSET: After the Swing, value has been accepted, the words “SET” and “OFFSET” will be shown on the screen, along with a flashing digit. This setting is shown as a number of degrees and is similar in nature to the Swing however this only affects the operation of the second (auxiliary) heating stage if present. The setting range for Offset is from 0 to 9 degrees. When set to 0 degrees, the second heating stage is completely disabled while in regular Heat mode (Emergency Heat mode will still function for heat pump configurations). An Offset value from 1 to 9 degrees will determine the number of degrees from the set point that will be required for the second heating stage to turn on. This setting can be used to conserve energy in situations where the second heating stage is more costly to operate when compared to the first stage
TEMPERATURE CALIBRATION: The internal temperature sensor in this
thermostat is accurately calibrated at the factory, and in most cases,
alterations to this setting should not be needed. The Temperature Calibration
feature allows you to manually offset the measured temperature by as much as
plus or minus 5°F (3°C) degrees from its original value. This feature can be
useful to match or synchronize this thermostat to another one or more if
multiple thermostats are used in the same home.
The Temperature Calibration setting need to be performed in a timely manner,
as the thermostat will timeout and automatically exit the adjustment screen
after approximately 10 seconds without a button press.
TO CHANGE THE TEMPERATURE CALIBRATION: Ensure that the System Mode switch is in the OFF position and the Set Slide switch is in the RUN position. Press and hold both the UP and DOWN buttons together for at least 5 seconds. The words “SET” and “CAL” will appear on the screen, along with a single flashing temperature digit. Use the UP/DOWN buttons to change the number of degrees of adjustment. 0° degrees is the default value and means no correction is being applied. Press the NEXT button to accept the setting.
TEMPERATURE LIMIT STOPS: There are two independent set temperature limit
stops a maximum heat set temperature and a minimum cool set temperature. These
stops do not prevent a user from performing normal actions like Temperature
Override or Hold. The Heat Limit Stop prevents the set temperature from being
adjusted higher than the heat limit setting. The Cool Limit Stop prevents the
set temperature from being adjusted lower than the cool limit setting. Each of
these temperature stops is user adjustable in one-degree increments, and these
settings are protected by a selectable 2-digit code to prevent unauthorized
tampering. By default, this 2-digit code is “00”, and the temperature stops
can be used as-is with this code.
NOTE: The Temperature Limit Stop settings need to be performed in a timely
manner, as the thermostat will timeout and automatically exit the setting
screens after approximately 10 seconds without a button press.
TO SET THE HEAT LIMIT STOP: Place the System Mode switch in the OFF position, and the Set Slide switch in the RUN position. Press and hold the UP button while sliding the System Mode switch from OFF to HEAT. The words “STOP” and “LOCK CODE” will appear on the screen, along with two digits. Use the UP/DOWN buttons to select the proper code to access the heat limit setting. Press the NEXT button to accept the setting. If the code you tried was not correct, the thermostat will exit and return to the Normal Run screen with no changes made. If the entered code is correct, the screen will add the word “SET” and display the current heat set temperature limit. Use the UP/DOWN buttons to adjust the maximum heat set temperature value. Press the NEXT button to accept the setting and return to the Normal Run screen in heat mode.
TO SET THE COOL LIMIT STOP: Place the System Mode switch in the OFF position, and the Set Slide switch in the RUN position. Press and hold the DOWN button while sliding the System Mode switch from OFF to COOL. The words “STOP” and “LOCK CODE” will appear on the screen, along with two digits. Use the UP/DOWN buttons to select the proper code to access the cool limit setting. Press the NEXT button to accept the setting. If the code you tried was not correct, the thermostat will exit and return to the Normal Run screen with no changes made. If the entered code is correct, the screen will add the word “SET” and display the current cool set temperature limit. Use the UP/DOWN buttons to adjust the minimum cool set temperature value. Press the NEXT button to accept the setting and return to the Normal Run screen in cool mode.
B Place the System Mode switch in the OFF position, and the Set Slide switch in the RUN position. Press and hold the NEXT button for at least 5 seconds. The words “STOP” and “LOCK CODE” will appear on the screen, along with two digits. Use the UP/DOWN buttons to enter the current code (“00” by default) and press the NEXT button one time. The word “SET” will now be displayed. Use the UP/DOWN buttons to choose a new 2-digit code between “00” and “99”. Press the NEXT button to accept the setting. The screen will flash briefly to confirm the code change, and return to the Normal Run screen in Off mode.
IF YOU FORGET YOUR TEMPERATURE STOP CODE: The code can be reset to the factory default “00” by performing the following steps. Place the System Mode switch in the OFF position, and the Set Slide switch in the RUN position. Press and hold the NEXT and HOLD buttons together for at least 10 seconds. The screen will start flashing, and display words “SET”, “STOP” and “LOCK CODE”, along with the new code of “00”. After a couple of seconds, the screen will automatically return to the Normal Run screen in Off mode.
KEYPAD LOCKOUT: You can lock the front panel buttons to prevent
unauthorized tampering of your thermostat settings.
NOTE: These keypad lock instructions need to be performed in a timely manner.
The 4-button sequence which locks the thermostat must be entered within a
10-second timeframe, or the keypad lockout sequence will have to be entered
again from the beginning.
TO LOCK THE KEYPAD: Start with the System Mode switch in either the HEAT or COOL positions and the Set Slide switch in the RUN position. Perform a single press of each button, in the following sequence: NEXT, NEXT, NEXT, HOLD.
TO UNLOCK THE KEYPAD: Start with the System Mode switch in either the HEAT or COOL positions and the Set Slide switch in the RUN position. Perform a single press of each button, in the following sequence: NEXT, NEXT, NEXT, HOLD. The padlock should no longer be present, with the thermostat now unlocked. If the padlock is still on the screen, please try to enter the 4-button sequence again
AIR FILTER MONITOR: In most systems that use a blower fan and air ducts, there is an air filter that is either replaceable or requires cleaning. The filter is usually located in the air handler, where the blower fan is. This thermostat feature assists you with keeping track of proper maintenance and/or periodic replacement intervals for your system’s filter. The Air Filter Monitor counts the duration of filter usage that has occurred, since the last time the Filter Monitor has been reset. This feature is for information purposes only, and does notaffect the operation of your heating or cooling equipment, or the thermostat. When the filter usage duration has completely expired, the word “FILTER” will flash on the screen.
TO SET THE AIR FILTER DURATION: Move the Set Slide switch to the “AIR FILTER” position. The word “DAYS” will be shown on the screen, along with the word “FILTER” and 2-3 characters at the top right corner of the display. Press either of the UP/DOWN buttons to select the desired filter duration (in days) from the following choices: OFF, 30, 60, 90, 120, 180, or 365. If the filter duration value is set to “OFF”, then the Air Filter Monitor will be completely disabled. Return the Set Slide switch to the RUN position when you are finished.
TO RESET THE FILTER USAGE COUNTER: Move the Set Slide switch to the “AIR FILTER” position. The three small digits at the top of the screen tell you the quantity of filter days remaining. Press both the UP and DOWN buttons together, and the usage counter will return to the beginning of the value that it originally started counting from. Refer to the previous paragraph, should you wish to change the starting value for the filter monitor. Return the Set Slide switch to the RUN position when you are finished.
HARDWARE RESET: The Hardware Reset button (labeled “HW RST”) is a small round push button that is located towards the right side of the circuit board, just below the battery holder. Pressing this button will cause the LCD display screen to become fully populated, the heating and cooling load relays to cycle off, read the position of the Hardware Setup Option switches, and will perform an internal system check of the thermostat components. If your thermostat appears to be acting in an erratic manner, pressing the Hardware Reset button may remedy this behavior. The temperature programs are not erased when a hardware reset is performed, however, the clock will have to be changed to match the current day and time.
SOFTWARE RESET: The Software Reset button (labeled “SW RST”) is a small round push button that is located towards the left side of the circuit board, just below the battery holder. A Software Reset is used to erase all heating and cooling temperature programs, and any user-adjustable software values such as: Swing, Offset, and Calibration, to their original factory default values. To perform a Software Reset, press and hold the Software Reset button for at
SW RST
At least 5 seconds. The LCD display screen will become fully populated,
then return to normal. The thermostat will still retain the current day and
time even after a Software Reset has been performed.
COMPRESSOR PROTECTION BYPASS: This optional feature permits the installer or service technician to temporarily disable the built in compressor protection delays. This is most useful for diagnosing and testing the heating and cooling systems after installation is complete, and should not be used during normal operation. To activate this feature, press and hold both the NEXT and HOLD buttons, while also performing a single press of the Hardware Reset button (the LCD display screen will become fully populated). Continue to hold the NEXT and HOLD buttons until the LCD display screen returns to normal. All compressor protection delays (in all modes of operation) will be disabled for 5 minutes. After the 5-minute duration has expired, the thermostat will return to normal operation automatically.
BATTERY REPLACEMENT
This thermostat is powered by two “AA” Alkaline batteries. The batteries
should be replaced AT LEAST once per year to ensure reliable operation (or
sooner, if the “LOW BATT” icon appears at the top of the display screen). The
batteries are located on the back of the thermostat, at the top of the circuit
board. The front portion of the thermostat can be removed from the back half
by pulling straight outwards on the top and bottom of the thermostat housing,
at the large indentations that are present in the center of the top and bottom
edges. When installing new batteries, we recommend using only brand new
Energizer® or DURACELL®, “AA” size alkaline batteries. Please observe the
polarity markings shown in the battery compartment to ensure proper
installation. When finished, line up the front of the thermostat to the base,
and firmly press together to securely latch the front and back halves together
properly
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat, please carefully and thoroughly review the instruction manual. If you require assistance, please contact our Technical Assistance department at 856- 234-8803 during regular business hours between 8:00 AM and 4:30 PM Eastern Standard Time, Monday through Friday. You can also receive technical assistance online anytime day or night at http://www.luxproproducts.com. Our website offers you troubleshooting guides and answers to the most common technical questions, and also permits you to email your questions to our technical support staff at your convenience.
LIMITED WARRANTY **
**
If this unit fails because of defects in materials or workmanship within three years of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to three years from the date of the original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the location from which the purchase was made, along with proof of purchase. Please refer to “TECHNICAL ASSISTANCE” before returning the thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of incidental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state. Applicable in the U.S.A. and Canada only.
MERCURY WARNING AND RECYCLING NOTICE
Mercury is considered to be a hazardous material. If this product is
replacing a thermostat that contains mercury in a sealed tube, contact your
local waste management authority for instructions regarding recycling and
proper disposal. It may be unlawful in your state to place it in the trash.
Mt. Laurel, New Jersey 08054, USA
http://www.luxproproducts.com856-234-8803
LUXPRO P521U PROGRAMMABLE / Non-Programmable THERMOSTAT Installation Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>