HEARTH HOME SA36R Woodburning Fireplace Owner’s Manual
- October 30, 2023
- HEARTH HOME
Table of Contents
Owner’s Manual
Operation and Care
SA36R Wood burning Fireplace
INSTALLER: Leave this manual with party responsible for use and
operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions on installation, operation, or service.
NOTICE: DO NOT discard this manual!
Model(s):
SA36R SA42R
WOODBURNING FIREPLACE
Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.
- DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- DO NOT overfire. Overfiring will void your warranty.
- Comply with all minimum clearances to combustibles as specified. Failure to comply may cause house fire.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during operation AND cool down.
Hot glass will cause burns
-
DO NOT touch glass until it is cooled
-
NEVER allow children to touch glass
-
Keep children away
-
CAREFULLY SUPERVISE children in same room as fireplace.
-
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable materials. -
Keep clothing, furniture, draperies and other flammable materials away.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate poisonous
gases (i.e. carbon monoxide).
Safety Alert Key:
- DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.
- WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury.
- CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
- NOTICE: Indicates practices which may cause damage to the fireplace or to property.
Welcome
Read this manual before installing or operating this fireplace.
Please retain this owner’s manual for future references.
A. Congratulations
Congratulations on selecting a HHT wood burning fireplace. The HHT fireplace
you have selected is designed to provide the utmost in safety and reliability.
As the owner of a new fireplace, you’ll want to read and carefully follow all
of the instructions contained in this Owner’s Manual. Pay special attention to
all Cautions and Warnings.
This Owner’s Manual should be retained for future reference.
We suggest that you keep it with your other important documents and product
manuals.
Your new HHT wood burning fireplace will give you years of durable use and
trouble-free enjoyment. Welcome to the HHT family of fireplace products!
DEALER: Fill in your name, address, phone and e-mail information here and fireplace information below.
Local Dealer Information
Dealer Name: ____
Address: ____
Phone:
E-mail:
Fireplace Information:
Brand: ____ Model Name:
Serial Number: __ Date Installed:
Listing Label Information/Location
The model information regarding your specific fireplace can be found on the
rating plate usually located in the control area of the fireplace.
► B. LIMITED LIFETIME WARRANTY
Hearth & Home Technologies LLC
LIMITED LIFETIME WARRANTY
Hearth & Home Technologies LLC (“HHT”) extends the following warranty for HHT
gas, wood, pellet and electric hearth appliances (each a “Product” and
collectively, the “Product(s)”) and certain component parts set forth in the
table below (“Component Part(s)”) that are purchased from a HHT authorized
dealer or distributor.
WARRANTY COVERAGE:
HHT warrants that the Products and their Component Parts will be free from
defects in materials and workmanship for the applicable period of Warranty
coverage set forth in the table below (“Warranty Period”). If a Product or
Component Parts are found to be
defective in materials or workmanship during the applicable Warranty Period,
HHT will, at its option, repair the applicable Component Part(s), replace the
applicable Component Part(s), or refund the purchase price of the applicable
Product(s). The maximum mount recoverable under this Warranty is limited to
the purchase price of the Product. This Warranty is transferable from the
original purchaser to subsequent owners, but the Warranty Period will not be
extended in duration or expanded in coverage for any such transfer. This
Warranty is subject to conditions, exclusions, and limitations as described
below.
WARRANTY PERIOD:
Warranty coverage begins at the date of installation. In the case of new home
constructions, Warranty coverage begins on the date of first occupancy of the
dwelling or six months after the sale of the Product(s) by an independent,
authorized HHT dealer or distributor, whichever occurs earlier. However, the
Warranty coverage shall commence no later than 24 months following the date of
Product shipment from HHT, regardless of the installation or occupancy date.
The term “Lifetime” in the table below is defined as: 20 years from the
beginning date of warranty coverage for gas appliances, 10 years from the
beginning date of warranty coverage for wood and pellet appliances, and 5
years from the beginning of warranty coverage for standalone gas log sets.
These time periods reflect the minimum expected useful lives of the designated
Component Parts under normal operating conditions.
Warranty Period | HHT Manufactured Appliances and Venting |
---|
Component
Parts| Labor| Gas| Pellet| Wood| Electric| Venting| Component Parts Covered by
this Warranty
1 Year| X| X| X| | X| All parts including handles. external enameled
components and other material except as covered by Warranty Conditions,
Warranty Exclusions. and Warranty Limitations listed
2 Years| | | | X| | All parts except as covered by Warranty Conditions,
Warranty Exclusions, and Warranty Limitations listed
2 years| | X| X| | | Igniters. Auger Motors, Electronic Components. and Glass
X| | | | | Electrical components limited to modules. remotes/wall switches.
valves. pilots, blowers. junction boxes, wire harnesses, transformers and
lights (excluding light bulbs)
X| | X| | | Molded Refractory Panels. Glass Liners
3 years| | X| | | | Firepots. bumpots, mechanical feeders/auger assemblies
5 years| X| | | | | Burners and logs for standalone gas log sets (Vented and
Vent Free gas log sets not sold as components of the fireplace or stove)
5 years| 1 year| X| | | | | Vent Free Burners and Vent Free Log components of
HHT manufactured fireplaces or stoves
| X| x| | | Castings. Medallions and Baffles
6 years| 3 years| | | X| | | Catalysts
7 years| 3 years| | X| X| | | Manifold tubes. HHT Chimney and Terminations
10 years| 1 year| X| | | | | Burners, logs and refractory components of HHT
manufactured fireplaces or stoves
Limited Lifetime| 3 years| X| X| X| | | Firebox and heat exchanger. FlexBurn•
System
(engine. inner cover, access cover and fireback)
|
1 Year| None| X| X| X| X| X| All purchased replacement parts
WARRANTY CONDITIONS:
- Because HHT cannot control the quality of any Products sold by unauthorized sellers, this Warranty only covers Products that are purchased through an HHT authorized dealer or distributor unless otherwise prohibited by law; a list of HHT authorized dealers is available on the HHT branded websites.
- This Warranty is only valid while the applicable Product remains at the site of original installation.
- This Warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the applicable Product is authorized to sell applicable Product.
- Contact your installing distributor or dealer for Warranty service. If the installing dealer or distributor is unable to provide necessary parts, contact the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking Warranty service from a dealer other than the dealer from whom you originally purchased the applicable Product.
- No HHT consumer should bear cost of warranty service or costs incurred while servicing warranty claims (i.e., travel, gas, or mileage) when the service is performed within the terms of this Warranty. Check with your dealer or distributor in advance for any costs to you when arranging a warranty call. Travel and shipping charges for parts are not covered by this Warranty.
WARRANTY EXCLUSIONS:
This Warranty does not cover the following:
- Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and exterior surface finishes may occur. This is not a flaw and is not covered under the Warranty.
- Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.
- Repair or replacement of parts that are subject to normal wear and tear during the Warranty Period are not covered. These parts include: paint, wood and pellet gaskets, firebricks, grates, flame guides, batteries and the discoloration of glass.
- Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and complaints related to this noise are not covered by this Warranty.
- Damages resulting from: (1) failure to install, operate, or maintain the applicable Product in accordance with the installation instructions, operating instructions, and listing agent identification label furnished with the applicable Product; (2) failure to install the applicable Product in accordance with local building codes; (3) shipping or improper handling; (4) improper operation, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or forced air furnaces or other such causes; (6) use of fuels other than those specified in the operation instructions; (7) installation or use of components not supplied with the applicable Product or any other components not expressly authorized and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing; and/or (9) interruptions or fluctuations of electrical power supply to the applicable Product.
- Non-HHT venting components, hearth connections or other accessories used in conjunction with the applicable Product.
- Any part of a pre-existing fireplace system in which an insert or a decorative gas applicable Product is installed.
- HHT’s obligation under this Warranty does not extend to the Product’s capability to heat the desired space. Information is provided to assist the consumer and the dealer in selecting the proper Product for the application. Consideration must be given to the Product location and configuration, environmental conditions, insulation and air tightness of the structure.
LIMITATIONS OF REMEDIES AND LIABILITY:
- EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED
HEREIN. The owner’s exclusive remedy and HHT’s sole obligation under this Warranty or in contract, tort or otherwise, shall be limited to replacement of the Component Part(s), repair of the Component Part(s), or refund of the original purchase price of the applicable Product(s), as specified above; provided, however, that (i) if HHT is unable to provide replacement of the Component Part(s) and repair of the Component Part(s) is not commercially practicable or cannot be timely made, or (ii) the customer is willing to accept a refund of the purchase price of the applicable Product(s), HHT may discharge all such obligations by refunding the purchase price of the applicable Product. In no event will HHT be liable for any incidental or consequential damages caused by defects in the applicable Product. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights and you may also have other rights which vary from State to State. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE FOR THE APPLICABLE PRODUCT. Some States do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
Product Specific and General Information
A. Appliance Certification
This fireplace system has been tested and listed in accordance with UL 127 and
CAN/ULC-S610 standards by Underwriters Laboratories Inc. for installation and
operation in the United States and Canada.
This fireplace may be installed in sleeping rooms. This fireplace is not
approved for installation in manufactured homes. If installed with a gas log
set, provisions for the National Fuel Gas Code must be met.
This fireplace has been tested and listed for use with the optional components
specified in this manual. These optional components may be purchased
separately and installed at a later date. An outside air kit, gas log set, gas
insert or gas log-lighter should be
installed at the time of fireplace installation.
Warning! Risk of Fire!
For use with solid wood fuel only.
Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide).
WARNING: This product and the fuels used to operate this product (wood and wood pellets), and the products of combustion of such fuels, can expose you to chemicals including carbon black, which is known to the State of California to cause cancer and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to: www.P65Warnings.ca.gov.
B. Vented Gas Log Sets, Unvented Gas Log Sets, Gas or Wood Inserts and Gas Log Lighters
- Optional
- Gas log sets, gas or wood inserts, or gas log-lighters can be installed in this fireplace. Follow the instructions provided with the accessory for operation.
Unvented Gas Logs
CAUTION!
If an unvented gas appliance is installed in the fireplace, the gas appliance
must only be operated with the fireplace glass door fully open (if included).
Only unvented gas log sets which have been found to comply with the standard
for unvented room heaters,
ANSI Z211.11.2, are to be installed in this fireplace. If an unvented gas
appliance is installed it must incorporate an automatic shutoff device, and
must be installed in accordance with the National Fuel Gas Code Z223.1, Latest
edition.
WARNING! Do Not operate an unvented gas log set in this fireplace with the chimney removed.
Important Safety and Operating Information
A. Fireplace Safety
Most problems are caused by improper installation and operation of the
fireplace.
To provide reasonable fire safety, the following should be given serious
consideration:
- The fire should be supervised whenever the fireplace is in use.
- An annual inspection should be performed on the fireplace system.
- Install at least one smoke detector on each floor of your home to ensure your safety.
- Install a conveniently located Class A fire extinguisher near the fireplace.
- Devise a practiced evacuation plan, consisting of at least two escape routes.
- Devise a plan to deal with a chimney fire:
– Evacuate.
– Notify the fire department.
WARNING! Risk of Fire! Hearth & Home Technologies disclaims any
responsibility for, and the warranty and agency listing will be voided by the
following actions.
DO NOT:
- operate damaged fireplace
- modify fireplace
- overfire
- install any component not approved by Hearth & Home Technologies
- install parts or components not listed or approved
- operate the fireplace without fully assembling all components
Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
1. Clear Space
Combustible materials must not be stored on the hearth extension. Room
furnishings such as drapes, curtains, chairs or other combustibles must be at
least 4 ft (1219 mm) from the front of the fireplace.
Combustible materials are materials made of or surfaced with any of the
following materials:
– Wood
– Plant fibers
– Plywood/OSB
– Compressed paper
– Plastic
– Drywall
– Any material that can ignite and burn, flame proofed or not, plastered or
un-plastered.
Non-combustible materials are materials which will not ignite and burn, composed of any combination of the following:
– Steel
– Brick
– Concrete
– Glass| – Iron
– Tile
– Slate
– Plasters
---|---
WARNING! Risk of Fire! Keep combustible materials, gasoline and other flammable vapors and liquids clear of the fireplace.
DO NOT:
- store flammable materials close to the fireplace
- use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this fireplace.
2. Grate
This fireplace is designed to be used with the supplied grate or one approved
by HHT.
WARNING! Risk of Fire! Use only the factory-supplied integral grate.
- Keeps logs in place.
- Allows proper air circulation around the fire.
3. Refractory
The refractory is supplied to contain heat and provide an attractive interior.
It will break down over time and will need occasional replacement. Small
hairline cracks and discoloration are normal and do not affect its safety.
WARNING! Risk of Fire! DO NOT burn fireplace without refractory. Use only
refractory supplied by Hearth & Home Technologies.
4. Firescreen
The firescreen is provided to control sparks. Keep it closed when the
fireplace in use.
WARNING! Risk of Fire or Burns!
- Screen will not prevent burning materials from falling out.
- Screen pulls or handles may be hot.
5. Flue Damper
The flue damper must be in the fully opened position during operation of the
fireplace.
WARNING! Risk of Fire and Asphyxiation! Open damper prior to operating
fireplace. A closed damper overfires the fireplace and spills smoke and flames
into the room.
6. Glass Doors
Glass doors are optional.
WARNING! Risk of Fire! Install ONLY doors approved by Hearth & Home
Technologies.
WARNING! Risk of Fire and Smoke! Fireplace equipped with doors should be
operated only with doors fully open or doors fully closed. If doors are left
partly open, gas and flame may be drawn out of the fireplace opening.
7. Over-Firing Your Fireplace
WARNING! Risk of Fire! Do not over-fire.
Over-firing may ignite creosote or will damage the fireplace and chimney.
To prevent over-firing your fireplace. DO NOT:
- use flammable liquids
- overload with wood
- burn trash or large amounts of scrap lumber
- permit too much air to the fire
Symptoms of over-firing may include one or more of the following:
- chimney connector or fireplace glowing
- roaring, rumbling noises
- loud cracking or banging sounds
- metal warping
- chimney fire
8. Chimney Fire
In the event of a chimney fire
- Have the chimney and adjacent structure inspected by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certified professionals, conduct a minimum of an NFPA 211 Level 2 inspection of the chimney.
- Replace components of the chimney and fireplace as specified by the professionals.
- Ensure all joints are properly engaged and the chimney is properly secured.
WARNING! Risk of Fire! A chimney fire can permanently damage your chimney system. Failure to replace damaged components and make proper repairs can cause a structure fire.
WARNING
HOT SURFACES!
Hot glass will cause burns.
-
DO NOT touch glass until it is cooled
-
NEVER allow children to touch glass
-
Keep children away
-
CAREFULLY SUPERVISE children in same room as fireplace.
-
Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable materials. -
Keep clothing, furniture, draperies and other flammable materials away.
Glass and other surfaces are hot during operation AND cool down.
CAUTION! If you expect that children may come into contact with this
fireplace, we recommend a barrier such as a decorative screen. See your dealer
for suggestions.
B. General Operating Parts
WARNING! DO NOT operate fireplace before reading and understanding
operating instructions. Failure to operate fireplace according to operating
instructions could cause fire or injury.
-
Flue Damper
The flue damper must be in the fully opened position (handle all the way to the right) during operation of the fireplace.
Before lighting the fireplace, verify fully open position by looking up from the inside of the fireplace. -
Outside Air (Optional)
Refer to Figure 3.2 for location and operation of control.
The outside air kit supplies some combustion air for your fireplace. Move handle to left to open. It may help reduce the effects of negative air pressure.
Close the inlet to prevent cold drafts when the fireplace is not being used. Move handle to right to close.
CAUTION! Outside air control handle may be warm.
Adjust before lighting fire. -
Glass Doors
• Glass doors are optional.
• Refer to Figure 3.3 for how to properly use them.
C. Fuel
WARNING! For use with solid wood fuel only.
Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide).
- Hardwood vs. Softwood
Your fireplace’s performance depends on the quality of the firewood you use. One species of wood varies very little to the other in terms of energy content. All seasoned wood contains about 8,000 BTU’s per pound. Hardwoods have a greater density than softwoods; a piece of hardwood will contain about 60% more BTU’s than an equal size piece of softwood. A cord of seasoned oak (hardwood) would contain about 60% more potential energy than a cord of seasoned pine (softwood). Most softwoods are coniferous. These are trees with needle-like leaves that stay green all year and carry their seeds exposed in a cone. Examples of coniferous trees are Douglas fir, pine, spruce and cedar. Softwoods, being more porous, require less time to dry, burn faster and are easier to ignite than hardwoods. Hardwoods are deciduous trees, broadleaf trees that lose their leaves in the fall. Their seeds are usually found within a protective pod or enclosure. Some examples of deciduous trees are oak, maple, apple, and birch. However, it should be noted that there are some deciduous trees that are definitely not considered hardwoods such as poplar, aspen and alder. Hardwoods require more time to season, burn slower and are usually harder to ignite than softwoods. Obviously, you will use the type of wood that is most readily available in your area. However, if at all possible the best arrangement is to have a mix of softwood and hardwood. This way you can use the softwood for starting the fire, giving off quick heat to bring the fireplace up to operating temperature. Add the hardwood for slow, even heat and longer burn time.
Soft woods | Hard woods |
---|
• Douglas Fir
• Pine
• Spruce
• Cedar
• Poplar
• Aspen
• Alder| • Oak
• Maple
• Apple
• Birch
WARNING! Risk of Fire!
• DO NOT burn wet or green wood.
• Wet, unseasoned wood can cause accumulation of creosote.
-
Moisture content
The majority of the problems fireplace owners experience are caused by trying to burn wet, unseasoned wood. Freshly cut wood can be as much water as it is wood, having a moisture content of around 50%. Imagine a wooden bucket that weighs about 8 pounds. Fill it with a gallon of water, put it in the firebox and try to burn it. This sounds ridiculous but that is exactly what you are doing if you burn unseasoned wood. Dead wood lying on the forest floor should be considered wet, and requires full seasoning time. Standing dead wood can be considered to be about two-thirds seasoned, if cut at the dry time of the year.
Burning wet, unseasoned wood will produce less heat output because it requires energy in the form of heat to evaporate the water trapped inside. This is wasted energy that should be used for heating your home. This moisture evaporates in the form of steam which has a cooling effect in your firebox and chimney system. When combined with tar and other organic vapors from burning wood it will form creosote which condenses in the relatively cool firebox and chimney.
Even dry wood contains at least 15% moisture by weight, and should be burned hot enough to keep the chimney hot for as long as it takes to dry the wood out – about one hour. To tell if wood is dry enough to burn, check the ends of the logs. If there are cracks radiating in all directions from the center, it is dry. If your wood sizzles in the fire, even though the surface is dry, it may not be fully cured. -
Seasoning
Seasoned firewood is nothing more than wood that is cut to size, split and air dried to a moisture content of around 20%. The time it takes to season wood varies from around nine months for soft woods to as long as eighteen months for hardwoods. The key to seasoning wood is to be sure it has been split, exposing the wet interior and increasing the surface area of each piece. A tree that was cut down a year ago and not split is likely to have almost as high a moisture content now as it did when it was cut.
To season wood:
• Cut logs to size
• Split to 6 in. (152 mm) or less
• Air dry to a moisture content of around 20%
– Soft wood – about nine months
– Hard wood – about eighteen months
NOTICE: Seasoning time may vary depending on drying conditions. -
Storing Wood
Splitting wood before it is stored reduces drying time.
The following guideline will ensure properly seasoned wood:
• Stack the wood to allow air to circulate freely around and through the woodpile.
• Elevate the woodpile off the ground to allow air circulation underneath.
• The smaller the pieces, the faster the drying process.
Any piece over 6 in. (152 mm) in diameter should be split.
• Wood should be stacked so that both ends of each piece are exposed to air, since more drying occurs through the cut ends than the sides. This is true even with wood that has been split.
• Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of scrap plywood, etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process. Avoid covering the sides and ends completely. Doing so may trap moisture from the ground and impede air circulation. -
Burning Process
Fire requires fuel, air and heat. If heat is robbed from the fireplace during the drying stage, the new load of wood has reduced the chances for a good clean burn. Always burn dry, seasoned firewood. -
Creosote Formation and Need For Removal
When wood is burned slowly, it produces tar and other organic vapors which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a newly-started or a slow-burning fire. As a result, creosote residue accumulates on the flue lining.
When ignited, creosote creates an extremely hot fire which may damage the chimney or even destroy the house.
The chimney shall be inspected at least annually before lighting, or once every two months during heating season.
When creosote has accumulated it shall be removed to reduce the risk of a chimney fire. -
Processed Solid Fuel Firelogs
Manufactured firelogs may be used with this fireplace. Hearth & Home Technologies recommends the use of ANSI/CAN/UL/ULC 2115 processed solid fuel firelogs and firestarters. Follow the manufacturer’s lighting and safety instructions.
Using firelogs may require more frequent chimney inspections and cleaning.
Do not poke or stir the logs while they are burning. Use only firelogs that have been evaluated for the application in manufactured fireplaces and refer to firelog warnings and caution markings on packaging prior to use.
D. First Fire
Before lighting your first fire in the fireplace, make certain that:
- refractory is in place
- all labels have been removed.
Note: Homeowners are encouraged to provide smoke and carbon monoxide alarms in accordance with the authority having jurisdiction.
E. Lighting Instructions
NOTICE : You must establish a good draft to prevent smoke spillage into
the room.
The first three or four fires should be of moderate size to allow the oils and
binders to be burned from the fireplace and the refractory and paint to cure.
You may notice an industrial odor the first few fires. This is considered
normal.
Use well-seasoned wood.
- Open the flue damper to a fully open position.
- Place crumpled or twisted paper under the fireplace grate.
- Loosely arrange kindling or small pieces of wood to form a ‘tent’ on the fireplace grate.
- Pre-warm the flue to establish a draft to help reduce smoke spillage during start-up. Hold a rolled up piece of burning newspaper under the flue damper for a few moments.
- Light the crumpled paper to ignite the kindling.
- Add small pieces of wood until a hot bed of embers has been established.
- Add a minimum of three average size pieces of split firewood, placed to allow combustion air and flames between them.
WARNING! Risk of Fire! Keep combustible materials, gasoline and other
flammable vapors and liquids clear of the fireplace.
DO NOT:
- store flammable materials close to the fireplace
- use gasoline, lantern fuel, kerosene, charcoal lighter fluid or similar liquids to start or “freshen up” a fire in this fireplace.
WARNING! Hot Surfaces!
Glass and other surfaces are hot during operation AND cool down. DO NOT clean
fireplace until it is cooled.
Installation and repair should be done by a qualified service technician only.
The fireplace should be inspected before use and at least annually by a
professional service person.
The following tasks may be performed annually by the homeowner. If you are
uncomfortable performing any of the listed tasks, please contact your dealer
for a service appointment.
WARNING! Risk of Asphyxiation and Fire! Annual inspection by qualified
technician recommended.
Check:
- condition of doors, surrounds and fronts
- condition of glass and glass assembly
- obstructions of combustion and ventilation air
- obstructions of termination cap
Clean:
- glass
- air passageways, grilles
A. Chimney Inspection
Frequency: As necessary; at least annually before lighting fireplace, or once
every two months during heating season.
By: Homeowner/Chimney Sweep
- Confirm that termination cap remains clear and unobstructed.
- Inspect for blockages such as bird nests, leaves, etc.
- Inspect for corrosion or separation.
- Inspect for creosote and remove as needed, at least every two months during the heating season.
- Inspect the system at the fireplace connection and at the chimney top.
In the event of a chimney fire, Hearth & Home Technologies recommends replacement of the chimney and inspection of the adjacent structure to the provisions of NFPA Level III inspection criteria.
B. Creosote (Chimney) Cleaning
Frequency: As needed; at least annually before lighting, or once every two
months during heating season.
When creosote has accumulated it shall be removed to reduce the risk of a
chimney fire.
By: Chimney Sweep
Tools Needed: Brush, Allen wrench, Phillips screwdriver
- When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire.
- Remove all ash from the firebox and extinguish all hot embers before disposal. Allow the fireplace to cool completely.
- Close the door tightly.
- Remove the top of the termination cap as shown in Figure 4.1 to clean the cap and chimney.
- The creosote or soot should be removed from the chimney with a brush specifically designed for the size of chimney in use.
- Reinstall termination cap.
- Clean out fallen debris from the firebox.
WARNING! Risk of Fire! Ignited creosote is extremely HOT. Prevent creosote buildup.
C. Grate
Frequency: After each ash removal
By: Homeowner
Inspect grate for:
- Warping or sagging 1-1/2 in. (38 mm) or more
- Broken welds
- Burn-through of grate bars
For safe operation, replace only with the approved grate from Hearth & Home Technologies.
D. Glass Cleaning
Frequency: As necessary
By: Homeowner
Tools Needed: Vinegar or glass cleaner, soft towel
- Clean glass with a non-abrasive glass cleaner. Use a damp cloth dipped in wood ashes or a commercially available oven cleaner. Remove any oven cleaner residue with a glass cleaner or soap and water.
E. Ash Removal
Frequency: As necessary
By: Homeowner
Tools Needed: Covered metal container, metal shovel, fireplace broom
WARNING! Risk of Fire! DO NOT remove ashes until the fire is out and the
fireplace is cold.
- Ashes should be placed in metal container with tight fitting lid.
- The closed container of ashes should be placed on a noncombustible floor or on the ground, well away from all combustible materials, pending final disposal.
- If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
F. Refractory
Frequency: After each ash removal
By: Homeowner
- Inspect condition of refractory. Replace if crumbly or otherwise deteriorated, or if cracks exceed 1/4 in. (6 mm).
Troubleshooting
Start Fire Problems | Possible Cause | Solution |
---|
Can’t get fire started Excessive smoke or spillage Burns too slowly Smolders,
sizzles| Not enough kindling/paper or no kindling/paper| Use dry kindling,
more paper. Arrange kindling & wood for air movement.
Damper closed/not fully open| Open damper.
Not enough air for fire to ignite| Check for restricted cap/shroud.
Open air kit (if installed).
Check for flue blockage.
Pre-warm flue before starting fire (refer to starting fire section).
Check for adequate vent height (refer to chimney assembly section).
Open window below the fireplace towards the wind.
Wood condition is too wet, too large| Use dry, seasoned wood (refer to wood
fuel section).
Bed of coals not established before adding wood| Start with paper & kindling
to establish bed of coals (refer to starting fire section).
Flue blockage such as birds’ nests or leaves in termination cap| Have chimney
inspected for creosote and cleaned by a certified chimney sweep.
Down draft or negative pressure Competition with exhaust devices| Do not use
exhaust fans during start-up (refer to negative pressure section).
Open window below the fireplace towards the wind.
Fire burns too fast| Extremely dry or soft wood| Mix in hardwood.
Mix in less seasoned wood after fire is established (refer to wood fuel
section).
Overdrafting| Check for correct vent height; too much vertical height creates
overdrafting.
Check location of vent termination (refer to chimney assembly section).
A. FAQs
Hearth & Home Technologies assumes no responsibility for the improper
performance of the fireplace system caused by inadequate draft due to
environmental conditions, down drafts, tight sealing construction of the
structure, or mechanical exhausting devices which will create a negative air
pressure within the structure where the fireplace is located.
If smoke spillage occurs from a fireplace opening when the door is open, there
is either a leakage in the flue, a blockage in the flue, or some condition is
affecting draft Understanding and differentiating the conditions which can
cause each of these kinds of spillage problems is essential to their
solution.
-
Flue Leakage
Check for improperly connected flue joints or a damaged flue joint in the chimney system. Such leakage would reduce draft (air would be drawn in through the leaks rather than through the fireplace).
The result might be difficult start-up and smoky fires that might spill if other adverse draft conditions accompany this problem. -
Flue Blockage
The damper should be open.
Check for objects that may have fallen down the chimney.
Flue draft is measured as negative pressure in the chimney. The amount of negative pressure determines how strong the draft is. The draft is important because it draws the combustion air into the fireplace and pulls the smoke out of the chimney.
There are three basic criteria essential in establishing and maintaining flue draft:
- availability of combustion air
- heat generated from the fire
- diameter and height of the flue system
These three factors work together as a system to create the flue draft.
Increasing or decreasing any one of them will affect the other two and thus
change the amount of draft in the entire system.
If the fire is hard to start and smoke spills out of the fireplace, or you
find it difficult to establish and maintain a moderately high burn rate, then
the flue draft is too low and corrective measures must be taken.
Be sure you have air available for combustion and that your firewood is dry
and well seasoned. Build your fires properly and according to the instructions
given in operating instructions, “Starting a Fire”. Be sure your flue system
is installed correctly and that it
is the proper diameter and height. Check for the following:
- All chimney sections are properly installed.
- The chimney is clean and free of creosote or soot buildup.
- Make sure overhanging trees and branches are cut back within ten feet of the top of the chimney and the chimney is free of debris from animals.
- Ensure the chimney cap is clean and free of any buildup of soot or creosote if cap is equipped with a spark arrestor screen.
- The wood being used in dry and well seasoned.
If you still suspect you have a low draft problem it may be necessary to increase the volume of air in your flue system. Since the diameter of your flue system is matched with the size of the flue collar and should not be changed, then the height of the system must be increased. Add chimney sections one at a time until the draft improves.
In some cases, regardless of what you do, it can still be difficult to
establish the proper flue draft. This is especially evident when using an
exterior factory-built chimney or exterior masonry chimney. Try holding a
burning rolled up newspaper as close to the flue
outlet as possible for a few minutes, then light the paper under the kindling.
The heat generated from the burning rolled up newspaper should help get the
draft established.
Still other factors can affect how well your flue system performs. Neighboring
structures, high winds, tall trees, even hillsides can affect air currents
around the chimney. Well designed chimney caps are available that can help.
Your fireplace dealer is the local expert in your area. He can usually make
suggestions or discover problems that can be easily corrected allowing your
fireplace to operate correctly as it has been designed, providing safe and
economical heat for your home.
Contact your dealer for additional information regarding operation and troubleshooting. Visit www.majesticproducts.com to find a dealer.
Reference Materials
► A. Service Parts
Service Parts
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM | DESCRIPTION | COMMENTS | PART NUMBER |
---|---|---|---|
1 | Starter Section | SRV22069 | |
2 | Top Standoff | Qty 4 req. | SRV4044-111 |
3 | Drywall Flange | 29238 | |
4 | Front Face (Top) | SRV30567BK | |
5 | Column (Right or Left) | SRV29899BK | |
6 | Hearth Filler | SRV30331BK | |
7 | Front Face (Botttom) | SRV29231BK | |
8 | Grate | GR18 | |
Grate Clip | Qty 2 req. | SRV28062 |
Additonal Service parts on following page.
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer
or distributor. Hearth and Home Technologies does not sell directly to
consumers. Provide model number and serial number when requesting service
parts from your dealer or distributor.
ITEM | DESCRIPTION | COMMENTS | PART NUMBER |
---|---|---|---|
Hang Down Damper Kit | Order for rod replacement | 30528 | |
Damper Weight | Order when rod is not being replaced | SRV19785 | |
Damper Blade | 30558 | ||
Door Pivot Clip | Qty 2 req. | SRV31527 | |
Firescreen Assembly | Qty 2 req. | 26053 | |
Firescreen Handle | Qty 2 req. | SRV10002 | |
Firescreen Rod | Qty 2 req. | SRV12052 | |
9 | Nailing Flange | Qty 4 req. | 31190 |
Outside Air Kit | AK22 | ||
Refractory Retainer | Qty 3 req | SRV11847 | |
Smoke Diverter | 30559 | ||
Strip Protector | Qty 2 req. | SRV18320 | |
Smoke Shield | SRV31191BK | ||
Upper Door Track | SRV15425BK | ||
Touch-Up Paint | 71479 | ||
Installation Manual | 4010-259 | ||
Owner’s Manual | 4010-260 |
#10 Refractory Assembly
10.1 | Hearth Refractory | SRV29993 |
---|---|---|
10.2 | Back Refractory | SRV29992 |
10.3 | Side Refractory (Left/right) | SRV28393 |
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM | DESCRIPTION | COMMENTS | PART NUMBER |
---|---|---|---|
1 | Starter Section | SRV22069 | |
2 | Top Standoff | Qty 4 req. | SRV4044-111 |
3 | Drywall Flange | 29238 | |
4 | Front Face (Top) | SRV30567BK | |
5 | Column (Right or Left) | SRV29899BK | |
6 | Hearth Filler | SRV30331BK | |
7 | Front Face (Botttom) | SRV29231BK | |
8 | Grate | GR18 | |
Grate Clip | Qty 2 req. | SRV28062 |
IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does not sell directly to consumers. Provide model number and serial number when requesting service parts from your dealer or distributor.
ITEM | DESCRIPTION | COMMENTS | PART NUMBER |
---|---|---|---|
Hang Down Damper Kit | Order for rod replacement | 30528 | |
Damper Weight | Order when rod is not being replaced | SRV19785 | |
Damper Blade | 30558 | ||
Door Pivot Clip | Qty 2 req. | SRV31527 | |
Firescreen Assembly | Qty 2 req. | 26053 | |
Firescreen Handle | Qty 2 req. | SRV10002 | |
Firescreen Rod | Qty 2 req. | SRV12052 | |
9 | Nailing Flange | Qty 4 req. | 31190 |
Outside Air Kit | AK22 | ||
Refractory Retainer | Qty 3 req | SRV11847 | |
Smoke Diverter | 30559 | ||
Strip Protector | Qty 2 req. | SRV18320 | |
Smoke Shield | SRV31191BK | ||
Upper Door Track | SRV15425BK | ||
Touch-Up Paint | 71479 | ||
Installation Manual | 4010-259 | ||
Owner’s Manual | 4010-260 |
#10 Refractory Assembly
10.1 | Hearth Refractory | SRV28391 |
---|---|---|
10.2 | Back Refractory | SRV28394 |
10.3 | Side Refractory (Left/right) | SRV28393 |
Accessories
Gas Inserts
Gas Log Sets
Gas Log Lighters
Wood-burning Inserts
Contact Information
Majestic, a brand of Hearth & Home Technologies 7571 215th Street West,
Lakeville, MN 55044
www.majesticproducts.com
Please contact your HHT dealer with any questions or concerns.
CAUTION
DO NOT DISCARD THIS MANUAL
- Important operating and maintenance instructions included.
- Read, understand and follow these instructions for safe installation and operation.
- Leave this manual with arty responsible for use and operation.
This product may be covered by one or more of the following patents: (United States) 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5413089, 5429495, 5452708, 5542407, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884,7047962, 7216645, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.
Printed in U.S.A. – Copyright 2012
Majestic Sovereign Series • SA36R/SA42R Owners Manual • 4010-260 • Rev K •