EMERSON White-Rodgers 1F87-361 Non-Programmable INSTALLATION AND OPERATION INSTRUCTIONS
- October 30, 2023
- Emerson
Table of Contents
- EMERSON White-Rodgers 1F87-361 Non-Programmable Thermostat
- DESCRIPTION
- Features
- PRECAUTIONS
- SPECIFICATIONS
- APPLICATIONS
- INSTALLATION
- BATTERY LOCATION
- Heating System
- OPERATION
- OPERATION
- PROGRAMMING YOUR THERMOSTAT
- Set Current Time and Day
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EMERSON White-Rodgers 1F87-361 Non-Programmable Thermostat
View all Emerson thermostat manual
DESCRIPTION
Your new White-Rodgers 7-Day Digital Thermostat uses the technology of a solid-state microcomputer to provide precise time/temperature control. This thermostat offers you the flexibility to design heating and cooling programs that fit your needs.
Features
- A separate program for each day of the week with four separate time/temperature periods per day
- Simultaneous heat and cool program storage
- preprogrammed temperature control
- Backlit display
- LCD continuously displays setpoint, and alternately displaysm time and room temperature
- Temperature override until next program period
- Manual program override (HOLD temperature)
- Temporary HOLD
- °F/°C convertibility
- Temperature range 45° to 90°F
- RC, RH, C, W, Y, G , O and B terminals
- Optional C terminal (Dual Power option)
- B and O terminals for single stage heat pumps (no auxiliary\ heat) or damper operation
- Program storage in case of power loss
- 2 “AA” Energizer® alkaline batteries included
PRECAUTIONS
This thermostat is intended for use with a low voltage system; do not use this thermostat with a line voltage system. If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor or electrician. Do not exceed the specification ratings. All wiring must conform to local and national electrical codes and ordinances. This control is a precision instrument, and should be handled carefully. Rough handling or distorting components could cause the control to malfunction.
CAUTION
To prevent electrical shock and/or equipment damage, disconnect electric power to system at main fuse or circuit breaker box until installation is complete.
WARNING
- Do not use on circuits exceeding specified voltage.
- Higher voltage will damage control and could cause shock or fire hazard.
- Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will damage thermostat and could cause personal injury and/or property damage.
- Thermostat installation and all components of the system shall conform to Class II circuits per the NEC code.
- For California Residents: This product contains a chemical known to the state of California to cause cancer and birth defects and other reproductive harm.
SPECIFICATIONS
ELECTRICAL DATA
- Electrical Rating: 8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.0 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
- Setpoint Temperature Range: 45°F to 90°F (7°C to 32°C)
- Operating Ambient Temperature Range: 32°F to 105°F
- Operating Humidity Range: 0 to 90% RH (non-condensing)
- Shipping Temperature Range: -4°F to 149°F
APPLICATIONS
- For use with
- Standard heat/cool or heat only systems
- Electric heat systems
- Gas or oil fired systems
- Gas systems with intermittent ignition devices (I.I.D.) and/or vent dampers
- Hydronic (hot water or steam) systems
- Single-stage heat pump systems (no auxiliary heat)
- Millivolt systems
- DO NOT USE IT WITH
- Multi-stage systems
- Systems exceeding 30 VAC and 1.5 amps
- 3-wire zoned hydronic heating systems
INSTALLATION
REMOVE OLD THERMOSTAT
- Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.
- Remove the front cover of the old thermostat. With wires still attached, remove wall plate from the wall. If the old thermostat has a wall mounting plate, remove the thermostat and the wall mounting plate as an assembly.
- Identify each wire attached to the old thermostat using the labels enclosed with the new thermostat.
- Disconnect the wires from old thermostat one at a time. DO NOT LET WIRES FALL BACK INTO THE WALL.
- Install new thermostat using the following procedures.
ATTENTION!
This product does not contain mercury. However, this product may replace a
unit that contains mercury. Do not open mercury cells. If a cell becomes
damaged, do not touch any spilled mercury. Wearing nonabsorbent gloves, take
up the spilled mercury with sand or other absorbent material and place into a
container which can be sealed. If a cell becomes damaged, the unit should be
discarded. Mercury must not be discarded in household trash. When the unit
this product is replacing is to be discarded, place in a suitable container.
Refer to www.thermostat-recycle.org for location to send product containing
mercury.
ELECTRIC HEAT OR SINGLE-STAGE HEAT PUMP SYSTEMS
This thermostat is configured from the factory to operate a heat/ cool, fossil
fuel (gas, oil, etc.), forced air system. It is configured correctly for any
system that DOES NOT require the thermostat to energize the fan on a call for
heat. If your system is an electric heat or heat-pump system that REQUIRES the
thermostat to turn on the fan on a call for heat, locate the ELECTRIC/GAS
switch on the back of the thermostat (see fig. 1) and switch it to the
ELECTRIC position. This will allow the thermostat to energize the fan
immediately on a call for heat. If you are unsure if the heating/cooling
system requires the thermostat to control the fan, contact a qualified heating
and air conditioning service person.
ATTACH THERMOSTAT BASE TO WALL
- Remove the packing material from the thermostat. Gently pull the cover straight off the base. Forcing or prying on the thermostat will cause damage to the unit. If necessary, move the electric heat switch (see ELECTRIC HEAT SYSTEMS, above).
- Connect wires beneath terminal screws on base using appropriate wiring schematic (see figs. 2 through 7).
- Place base over hole in wall and mark mounting hole locations on wall using base as a template.
- Move base out of the way. Drill mounting holes.
- Fasten base loosely to wall, as shown in fig. 1, using two mounting screws. Place a level against bottom of base, adjust until level, and then tighten screws. (Leveling is for appearance only and will not affect thermostat operation.) If you are using existing mounting holes, or if holes drilled are too large and do not allow you to tighten base snugly, use plastic screw anchors to secure subbase.
- Push excess wire into wall and plug hole with a fire-resistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.
BATTERY LOCATION
2 “AA” alkaline batteries are included in the thermostat at the factory with a
battery tag to prevent power drainage. You must remove the battery tag to
engage the batteries.
If “BATT” or “CHANGE ” is displayed, the batteries are low and should be
replaced with fresh “AA” Energizer® alkaline batteries. To replace batteries,
install the batteries along the top of the base (see Fig. 1). The batteries
must be installed with the positive (+) end to the left.
HYDRONIC (HOT WATER OR STEAM)
HEATING SYSTEMS
This thermostat is set to operate properly with a forced-air heating system.
If you have a hydronic heating system (a system that heats with hot water or
steam), you must set the thermostat to operate properly with your system.
Change the second option in the configuration menu to SL (see CONFIGURATION
MENU, page 4).
CHECK THERMOSTAT OPERATION
If at any time during testing your system does not operate properly, contact a
qualified service person. Turn on power to the system.
Fan Operation
If your system does not have a G terminal connection, skip to Heating System.
- Move FAN switch to ON position. The blower should begin to operate.
- Move FAN switch toAUTO position. The blower should stop immediately.
Heating System
-
Move SYSTEM switch to HEAT position. If the heating system has a standing pilot, be sure to light it.
-
Press to adjust thermostat setting above room temperature.
The heating system should begin to operate. -
Press to adjust thermostat setting below room temperature.
The heating system should stop operating.
Cooling System
To prevent compressor and/or property damage, if the outdoor temperature is
below 50°F, DO NOT operate the cooling system
- Move SYSTEM switch to COOL position.
- Press to adjust thermostat setting below room temperature.
- The blower should come on immediately on high speed, followed by cold air circulation
- Press to adjust thermostat setting above room temperature.
The cooling system should stop operating.
OPERATION
Before you begin programming your thermostat, you should be familiar with its features and with the display and the location and operation of the thermostat buttons. Your thermostat consists of two parts: the thermostat cover and the base. To remove the cover, pull it straight out from the base. To replace the cover, line up the cover with the base and press until the cover snaps onto the base.
The Thermostat Buttons and Switches
-
raise the temperature setting.
-
lowers temperature setting.
-
TIME button.
-
PRGM (program) button.
-
RUN (run program) button.
-
HOLD temperature button.
-
FAN switch (ON, AUTO).
-
SYSTEM switch (COOL, OFF, HEAT).
The Display -
Indicates day of the week.
-
Flame icon ( ) is displayed when the SYSTEM switch is in the HEAT position. Snowflake icon ( )is displayed (non-flashing) when the SYSTEM switch is in the COOL position. Snowflake is displayed (flashing) if the thermostat is in lockout mode to prevent the compressor from cycling too quickly.
-
Displays “BATT” or “CHANGE ” when the 2 “AA” batteries are low and should be replaced. Only “BATT” or “CHANGE ” and “LO” in the minutes field are displayed when batteries are low with no system power.
-
Alternately displays current time and temperature. Displays “LO” in the minutes field when batteries are low.
-
The word “HOLD” is displayed when the thermostat is in
the HOLD mode. “HOLD” is displayed flashing when the
thermostat is in a temporary HOLD Mode. -
Displays currently programmed set temperature (this is
blank when the SYSTEM switch is in the OFF position). -
Displays “FLTR” when the system has run for the programmed filter time period as a reminder to change or clean your air filter.
OPERATION
CONFIGURATION MENU
The configuration menu allows you to set certain thermostat operating
characteristics to your system or personal requirements. Press RUN to make
sure the thermostat is in the run program mode, then press PRGM and RUN at the
same time to enter the configuration menu. The display will show the first
item in the configuration menu. The configuration menu table summarizes the
configuration options. An explanation of each option follows.Press HOLD to
change to the next menu item or press TIME to go backwards to the previous
item in the menu. To exit the menu and return to the program operation, press
RUN. If no keys are pressed within fifteen minutes, the thermostat will revert
to normal operation.
Step| Press Button(s)| Displayed (Factory Default)|
Press or to select:| COMMENTS
---|---|---|---|---
1| PRGM and RUN| HOLD (0:00)| 0 to 8 hrs (in15 minute increments)|
Select temporary Hold time
2| HOLD *| ** (FA)| SL| Select FA or SL (Fast or Slow) heating cycle
rate
3| HOLD | d-L (ON)| OFF| Select display backlight OFF or ON
4| HOLD | E (ON)| OFF| Select Energy Management Recovery OFF or ON
5| HOLD | Filter (000)| 0 to 1950 hours(in 50 hour increments)| Select
filter replacement run time
6| HOLD | LOC (OFF)| ON| Select compressor lockout OFF or ON
7| HOLD | 0 HI(0)| 4 LO to4 HI| Select temperature display adjustment
higher or lower
8| HOLD | (F)| C| Select temperature display to F or C
9| RUN**| | | Returns to normal operation
-
Select Temporary Hold Time – The thermostat can hold any temperature you set it to for the amount of time you select on this option. Your choices are 0:00 to 8:00 hours in 15 minute increments. 0:00 disables the function
Example:- You have selected 3:00 hours for the Temporary Hold time period.
- With the thermostat set to Heat or Cool, press HOLD for approximately five seconds until HOLD time (3:00 indicating 3 hours) appears as a setting reminder.
- After releasing the button, “HOLD” on the display will blink.
- Use to set the temperature to your preference. The thermostat will maintain this temperature setting for 3 hours with “HOLD” blinking to remind you it is in Temporary Hold. After 3 hours the thermostat will go back to the programmed temperature and “HOLD” will no longer blink or display.
-
- Select FA or SL (Fast or Slow) Heating Cycle Rate – The FA setting is frequently used for gas, oil or electric heat. The SL setting produces a longer heating cycle which is normally for hot water or steam (hydronic) systems. Both settings produce very accurate temperature control and can be set to your personal preference. FA cycles the system just under 1°F and the SL setting cycles at approximately 1.5°F.
-
Select backlit display – The display backlight improves display contrast in low lighting conditions. Selecting backlight ON will keep the light on for a short period of time after any key is pressed. Selecting OFF will keep the light off.
-
- Select Energy Management Recovery OFF or ON –Energy Management Recovery (EMR) causes the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint. Cooling allows more time per degree because it takes longer to reach temperature. Example: You select EMR and have your heating programmed to 65° at night and 70° at 7 AM. If the building temperature is 65° the difference between 65° and 70° is 5°. Allowing 5 minutes per degree the thermostat setpoint will change to 70° at 6:35 AM.
-
Select filter replacement run time – The thermostat will display “FLTR” after a set time of operation. This is a reminder to change or clean your air filter. This time can be set from 0 to 1950 hours in 50 hour increments. A selection of 000 will cancel this feature. When “FLTR” is displayed, you can clear it by pressing HOLD and RUN at the same time. This resets the timer and starts counting the hours until the next filter change. Changing the time in the menu also resets the timer.
-
Select Compressor Lockout LOC OFF or ON – Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the feature is already present in their system. When the compressor time delay occurs it will flash the (snowflake icon) for about five minutes then turn on the compressor.
-
Select Temperature Display Adjustment 4 LO to 4 HI – Allows you to adjust the room temperature display 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat.
-
Select F° or C° Readout – Changes the display readout to Centigrade or Fahrenheit as required.
Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat.
- SIMULTANEOUS HEATING/COOLING PROGRAM STORAGE — When programming, you can enter both your heating and cooling programs at the same time. There is no need to reprogram the thermostat at the beginning of each season.
- TEMPERATURE OVERRIDE — Press until the display shows the temperature you want. The thermostat will override current programming and keep the room temperature at the selected temperature until the next program period begins. Then the thermostat will automatically revert to the program.
- HOLD TEMPERATURE — The thermostat can hold any temperature within its range for an indefinite period without reverting to the programmed temperature. Momentarily press the HOLD button. “HOLD” will be displayed. Then choose the desired temperature by pressing . The thermostat will hold the room temperature at the selected setting until you press the RUN button to start program operation again.
- CONFIGURATION MENU — Allows you to customize certain thermostat options.
PROGRAMMING YOUR THERMOSTAT
This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.
- When heating (cooling) your building, program the temperatures to be cooler (warmer) when the building is vacant or during periods of low activity.
- During early morning hours, the need for cooling is usually minimal.
Planning Your Program
Look at the factory preprogrammed times and temperatures shown in the sample
schedule. If this program will suit your needs, simply press the RUN button to
begin running the factory preset program.
If you want to change the preprogrammed times and temperatures, follow these
steps. Determine the time periods and temperatures for your daily programs.
You must program four periods for both the weekday and weekend program.
However, you may use the same heating and cooling temperatures for consecutive
time periods. You can choose start times, heating temperatures, and cooling
temperatures independently for each day programs (for example, you may select
5:00 AM and 70° as the Monday 1st period heating start time and temperature,
and also choose 7:00 AM and 76° as the Monday 1st period cooling start time
and temperature).
Use the following table to plan your program time periods and the temperatures
you want during each period. Fill in the complete table to have a record of
your programs.
Entering Your Program
Follow these steps to enter the heating and cooling programs you have
selected.
Set Current Time and Day
- Press TIME button once. The display will show the hour only.
- Press and hold either until you reach the correct hour and AM/PM designation (AM begins at midnight; PM begins at noon).
- Press TIME once. The display window will show the minutes only.
- Press and hold either until you reach the correct minutes.
- Press TIME once. The display will show the day of the week.
- Press until you reach the current day of the week.
- Press RUN once. The display will show the correct time and room temperature alternately.
Enter Heating Program
-
Move the SYSTEM switch to HEAT.
-
Press PRGM once. “MO” (indicating Monday program) will appear in the display. Also displayed are the currently programmed start time for the 1st heating period and the currently programmed temperature (flashing).
This display window shows that for Monday’s 1st heating period, the start time is 6:00 AM, and 70° is the programmed temperature (this example reflects factory preprogramming). -
Press to change the displayed temperature to your selected temperature for Monday’s 1st heating program period.
-
Press TIME once (the programmed time will flash). Press until your selected start time for Monday’s 1st heating program period appears. The time will change in 15 minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode.
-
Press PRGM once. The currently programmed start time and setpoint temperature for Monday’s 2nd heating program period will appear.
-
Repeat steps 3 and 4 to select the start time and heating temperature for Monday’s 2nd heating program period.
-
Repeat steps 3 through 5 for the 3rd and 4th heating program periods. Monday heating programs are now complete.
If you are programming your thermostat for the first time and you want programming for all days of the week to be the same as Monday’s program, press RUN or HOLD at this point, and proceed to Enter Cooling Program. (This simplified COPY DAY feature only works the first time you program your thermostat. If you want to copy one day’s programming to a specific day programming, refer to COPY DAY FUNCTION in OPERATING FEATURES. If you are changing your thermostat’s programming, you must program each day separately.) -
Press HOLD once. “TU” (indicating Tuesday program) will appear in the display, along with the start time for the 1st heating period and the currently programmed temperature.
-
Repeat steps 3 through 7 to complete Tuesday’s heating programming.
-
Continue entering each day’s programming until all heating periods time and temperatures have been entered.
-
When you have completed entering your heating program, press RUN.
SAMPLE
Heating/Cooling Schedule Plan (Factory Program)
Period
| ALL DAYS OF THE WEEK
---|---
Start Time| Temperature
HEAT| 1ST| 6:00 AM| 70 F
2ND| 8:00 AM| 62 F
3RD| 5:00 PM| 70 F
4TH| 10:00 PM| 62 F
COOL| 1ST| 6:00 AM| 78 F
2ND| 8:00 AM| 85 F
3RD| 5:00 PM| 78 F
4TH| 10:00 PM| 82 F
Heating/Cooling Schedule Plan
| PERIOD 1| PERIOD 2| PERIOD 3| PERIOD 4
---|---|---|---|---
HEAT| COOL| HEAT| COOL| HEAT| COOL| HEAT| COOL
Time| Temp| Time| Temp| Time| Temp| Time| Temp| Time| Temp| Time| Temp| Time|
Temp| Time| Temp
Mon| | | | | | | | | | | | | | | |
Tues| | | | | | | | | | | | | | | |
Wed| | | | | | | | | | | | | | | |
Thur| | | | | | | | | | | | | | | |
Fri| | | | | | | | | | | | | | | |
Sat| | | | | | | | | | | | | | | |
Sun| | | | | | | | | | | | | | | |
Enter Cooling Program
If the outside temperature is below 50°F, disconnect power to the cooling system before programming. Energizing the air conditioner compressor during cold weather may cause personal injury or property damage.
- Move SYSTEM switch to COOL position.
- Follow the procedure for entering your cooling program, using your selected cooling times and temperatures.
CHECK YOUR PROGRAMMING
- Follow these steps to check your thermostat programming one final time before beginning thermostat operation.
- Move SYSTEM switch to HEAT position.
- Press PRGM to view the 1st Monday heating period time and temperature. Each time you press PRGM, the next heating period time and temperature will be displayed in sequence for Monday. Press HOLD to display Tuesday’s 1st heating period, and press PRGM to view each of the remaining Tuesday’s heating period time and temperatures. To view each day’s heating program, press HOLD to change day and them press PRGM to look at each programming period for the day. (You may change any time or temperature during this procedure.)
- Press RUN.
- Move SYSTEM switch to COOL position.
- Repeat step 2 to check cooling program.
- Move SYSTEM switch to HEAT or COOL and press RUN to begin program operation.
YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED AND READY TO PROVIDE MAXIMUM COMFORT AND EFFICIENCY!
TROUBLESHOOTING
Reset Operation
If a voltage spike or static discharge blanks out the display or causes
erratic thermostat operation you can reset the thermostat by pressing , and
TIME at the same time. This
also resets the factory defaults to the configuration menu and program. If the
thermostat has power, has been reset and still does not function correctly
contact your heating/cooling service person or place of purchase.
Batteries
For optimum performance, we recommend replacing batteries once a year with
fresh “AA” Energizer® alkaline batteries.
Symptom | Possible Cause | Corrective Action |
---|---|---|
No Heat/No Cool/No Fan (common problems) | 1. Blown fuse or tripped |
circuit breaker.2. Furnace power switch to OFF.
3. Furnace blower compartment door or panel loose or not properly installed.
| Replace fuse or reset breaker. Turn switch to ON.Replace door panel in
proper position to engage safety interlock or door switch.
No Heat| 1. Pilot light not lit.2. SYSTEM Switch not set to
HEAT.
3. Loose connection to thermostat or system.
4. Furnace Lock-Out Condition. Heat may also be intermittent.
5. Heating System requires service or thermostat requires replacement.
| Re-light pilot.Set SYSTEM Switch to Heat and raise setpoint above room temperature.
Verify thermostat and system wires are securely at- tached.
Many furnaces have safety devices that shut the sys- tem down when a lock-out condition occurs. If the heat works intermittently contact the furnace manufacturer or local service person for assistance.
Diagnostic: Set SYSTEM Switch to HEAT and raise the setpoint above room temperature. Within a few seconds the thermostat should make a soft click sound. This sound usually indicates the thermostat is operating properly. If the thermostat does not click, try the reset operation listed above. If the thermostat does not click after being reset contact your heating and cooling service person or place of purchase for a replacement. If the thermostat clicks, contact the
furnace manufacturer or a service person to verify the heating system is operating correctly.
Symptom | Possible Cause | Corrective Action |
---|---|---|
No Cool | 1. SYSTEM Switch not set to COOL below2. Loose |
connection to thermostat or system.
3. Cooling System requires service or thermostat requires replacement.
| Set SYSTEM Switch to COOL and lower setpoint room temperature.Verify thermostat and system wires are securely attached.
Same procedure as diagnostic for No Heat condition except set the thermostat to COOL and lower the setpoint below the room temperature. There may be up to a five minute delay before the thermostat clicks in Cooling if the compressor lock-out option is selected in the configuration menu (Item 6).
Heat, Cool or Fan Runs Constantly.| 1. FAN Switch set to Fan ON.2. Possible short in wiring.
3. Possible short in thermostat.
4. Possible short in Heat/Cool/Fan system.
| Check each wire connection to verify they are not shorted or touching
together. No bare wire should stick out from under terminal screws. Try
resetting the thermostat. If the condition persists the manufacturer of your
system or service person can instruct you on how to test the Heat/ Cool system
for correct operation. If the system operates correctly, replace the
thermostat.
Furnace Cycles Too Fast or Too Slow (narrow or wide
temperature swing)| 1. The location of the thermostat and/or the size of
the Heating System may be influencing the cycle rate.| Item 2 in the
Configuration Menu is the adjustment that controls the cycle rate. If an
acceptable cycle rate is not achieved using the FA (Fast) or SL (Slow)
adjustment contact a local service person for additional suggestions.
Cooling Cycles Too Fast or Too Slow (narrow or wide
temperature swing)| 1. The location of the thermostat and/or the size of
the Cooling System may be influencing the cycle rate.| The cycle rate for
cooling is fixed and can not be adjusted. Contact a local service person for
suggestions.
Thermostat Setting and Thermometer Disagree| 1. Thermostat
thermometer setting requires adjustment.| The thermometer can be adjusted +/-
4 degrees as listed in item 7 of the Configuration Menu. No other adjustment
is possible.
Clock Loses or Gains Time| 1. Loss of power to thermostat and low
batteries.| The thermostat will maintain its program in memory even with no
power/no batteries but the clock time will be incorrect when power is
restored. See No Heat/No Cool/No Fan (common problems) above for items to
check in the system.
Heat or Cool Starts Early| 1. EMR activated| See Configuration Menu
(Item 4).
Thermostat Does Not Follow Program| 1. AM or PM set incorrectly in
program.2. AM or PM set incorrectly on the clock.
3. Voltage spike or static discharge.
| Check current clock and program settings including the AM or PM designations
for each time period. If a voltage spike or static discharge occurs use the
Reset Operation listed above.
Blank Display and/or Keypad Not Responding| 1. Loss of power and
dead batteries.2. Voltage Spike or Static Discharge.| Replace batteries and
check heat/cool system for proper operation. If a voltage spike or static
discharge occurs use the Reset Operation listed above.
HOMEOWNER HELPLINE: 1-888-725-9797 White-Rodgers is a business of Emerson