COLOMBO I Iodine Test for Marine Water Instructions

October 30, 2023
COLOMBO

Colombo BV
www.colombo.nl
Nr: 259302-V3

I (Iodine)

General Guidelines

  • Ensure that the test tube is clean before use.
  •  Clean the tube directly after use.
  • Take the volume of the water sample as precisely as possible.
  • Keep the dripping bottle perfectly vertical during dropping.
  • Take care that no air bubbles are  included in the drops.

Test procedure:

  1. Take a water sample of 5 ml.
  2.  Add 5 drops of I-1 test fluid and shake the test tube.
  3.  Add 5 drops of I-2 test fluid and shake the test tube.
  4.   Wait 20 minutes.
  5.  Determine the Iodine content using the colour chart included.

Deutsch – I (Jod)
Allgemeine Richtlinien

  •  Sorgen Sie immer dafür, dass das Reagenzglas vor Verwendung sauber ist.

  • Reinigen Sie das Reagenzglas sofort nach der Verwendung.

  • Nehmen Sie die Menge der Wasserprobe so genau wie möglich

  • Halten Sie beim
    Tropfen das Fläschchen vollkommen vertikal.

  • Achten Sie darauf, dass keine Luftbläschen in die Tropfen gelangen.

Testverfahren:

  1. Nehmen Sie eine Wasserprobe von 5 ml.
  2.  Geben Sie 5 Tröpfchen I-1 Test-

 For judging the colour of the water sample after adding all the test fluids, proceed as follows: put the test tube on the included colour chart and look through the tube on to the chart from directly above it. Do not look in direct sun light, but at indirect light. Compare the colour of the water sample with the colours on the chart. The closest colour shows the corresponding value. Generally the colours of the sample and on the chart will not be exactly the same, as values in practice will always be between the standard values, and thus a mixture of both consecutive values. Therefore, one should estimate between which colours the sample really lies.
COLOMBO I Iodine Test for Marine Water - iconI2-2: Danger
H314:  Causes severe skin burns and eye damage
P501:  Dispose of contents
P305+351+338: BIJ CONTACT MET DE OGEN:  IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
IN CASO DI CONTATTO CON GLI OCCHI:  contains

Scan to watch our instruction movie or visit our website
www.colombo.nl http://www.colombo.nl/imarinetest

Made in
Holland
Colombo BV
Franse Akker 7
NL-4824 AL, Breda
The Netherlands
Tel: +31-(0)76-3038727