COLOMBO Fe Iron Test for Marine Water Instructions

October 30, 2023
COLOMBO

Fe Iron Test for Marine
Water Instructions

Fe Iron Test for Marine Water

Fe (Iron)
General Guidelines

  • Ensure that the test tube is clean before use.
  • Clean the tube directly after use.
  • Take the volume of the water sample as precisely as possible.
  • Keep the dripping bottle perfectly vertical during dropping.
  • Take care that no air bubbles are included in the drops.

Test procedure:

  1. Take a water sample of 10 ml.
  2. Add 1 spoon of powder (tube with red cap) and shake the test tube.
  3.  Add 5 drops of Fe-2 test fluid and shake the test tube.
  4. Wait 10 minutes.
  5. Determine the Iron content using the color chart included.

Fe-2: GuevaraCOLOMBO Fe Iron Test for Marine Water -
icon

H318: Causes serious eye damage
P102:  Keep out of reach of children
P501:  Dispose of contents/container to an approved waste disposal plant
P305+351+338:  IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing / EN CAS DE CONTACT AVEC LES YEUX:
CONTACT AVEC LES YEUX:
contains

COLOMBO Fe Iron Test for Marine Water - fig

For judging the colours of the water sample after adding all the test fluids, proceed as follows: put the test tube on the included colours chart and look through the tube on to the chart from directly above it. Do not look in direct sun light, but at indirect light. Compare the colours of the water sample with the colours on the chart. The closest colours shows the corresponding value. Generally the colours of the sample and on the chart will not be exactly the same, as values in practice will always be between the standard values, and thus a mixture of both consecutive values. Therefore, one should estimate between which colours the sample really lies.
Scan to watch our instruction movie or visit our website www.colombo.nl

COLOMBO Fe Iron Test for Marine Water - qr code

http://www.colombo.nl/femarinetest

Made in Holland
Colombo BV
France Akker 7
NL-4824 AL Breda
The Netherlands
Tel: +31-(0)76-3038727